{"product_id":"serpentin-devaporateur-york-ctm36b5cds1-a-3-tonnes","title":"YORK CTM36B5CDS1 Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003e3-ton York coil CTM36B5CDS1: the narrow size matched to the HH836E2S11 unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eCTM36B5CDS1\u003c\/strong\u003e is a cased A-coil, 17-1\/2 in wide, that York designs for small furnaces. In our catalogue, it is the narrow option that connects to the \u003cstrong\u003eHH836E2S11\u003c\/strong\u003e outdoor unit. Like all its siblings, it uses R-454B refrigerant. We install it for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore, in homes where the space around the furnace is unforgiving.\u003c\/p\u003e\n\n\u003ch3\u003eUpfront honesty about the ratings\u003c\/h3\u003e\n\u003cp\u003eIt is better to say it right away: this match is not the one with the highest ratings in the series. The certified system carries AHRI number 214606513 and publishes a SEER2 and HSPF2 of 15.2 \/ 8.1, with 32,800 BTU\/h of cooling and 31,000 BTU\/h of heating at 47 °F. York also states that most matches of its HH8 units are cold-climate certified, but this one is not (HSPF2 8.1).\u003c\/p\u003e\n\u003cp\u003eIs that a flaw? Not necessarily. It means this system suits someone looking first for air conditioning, or who keeps their furnace running actively during the coldest weather, better than someone counting on the heat pump to carry the winter alone. We would rather you know before the quote than in January.\u003c\/p\u003e\n\n\u003ch3\u003eThe plenum decides everything\u003c\/h3\u003e\n\u003cp\u003eBefore the price, before the brand, even before the capacity, there is one measurement: the width of your plenum. The CTM36B5CDS1 is 17-1\/2 in wide and 25-5\/8 in high, and its net weight is 50 lb. If your furnace is this width, the coil goes in without a detour. If it is wider, we build an insulated transition on site. If it is wider by a good margin, a 21 in model may make sense, and we discuss that below.\u003c\/p\u003e\n\u003cp\u003eThe coil comes in multiple positions: upflow, downflow, horizontal left or right. A low-ceiling basement, where the furnace lies on its side, is therefore not ruled out.\u003c\/p\u003e\n\n\u003ch3\u003eOur place in the series: four models, two widths\u003c\/h3\u003e\n\u003cp\u003eAll models in the series are 3 tons (36,000 BTU\/h), cased, on R-454B and with a TXV metering device. So you choose between them on the basis of two criteria.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e17-1\/2 in width: CTM36B5ADS1, matched to the HH824E2S11 unit, and the CTM36B5CDS1 on this page, matched to the HH836E2S11 unit;\u003c\/li\u003e\n\u003cli\u003e21 in width: CTM36C5ADS1, with no unit specified in our file, and CTM36C5CDS1, also matched to the HH836E2S11 unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CTM36B5CDS1 and the CTM36C5CDS1 therefore share the same outdoor unit; only the width of the cabinet changes. If your furnace is narrow, you are on the B5 side. If it is wide, look at the C5 side. Finally, the CTM36B5ADS1 shares our narrow width, but it pairs with the other outdoor unit, the HH824E2S11.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does, without the jargon\u003c\/h3\u003e\n\u003cp\u003eThink of a radiator in reverse. Cold refrigerant flows through aluminum and copper tubes; warm air from the house passes between the fins, gives up its heat and comes out cooler. Moisture in the air condenses on the fins, drops into the pan and drains away through the condensate drain. That is why an air-conditioned house feels not only cooler but also drier.\u003c\/p\u003e\n\u003cp\u003eWith a heat pump, the cycle can reverse in winter and heat from outside is carried indoors. The furnace stays ready to take over below the threshold we set with you.\u003c\/p\u003e\n\n\u003ch3\u003eR-454B refrigerant safety\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L class refrigerant. For this reason, this coil ships with a factory-installed A2L sensor (code S), attached to the coil plate and wired to the RDS control board. If the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts. You have nothing to adjust.\u003c\/p\u003e\n\n\u003ch3\u003eCTM36B5CDS1 specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand and range: York, CTM;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal capacity: 3 tons, or 36,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003emetering device: TXV;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 1,200 CFM;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in for liquid, 3\/4 in for suction;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 17-1\/2 × 25-5\/8 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 50 lb;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited parts warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuestions we often hear\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil provide heat?\u003c\/strong\u003e Yes, when it is matched to a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not. The coil runs on R-454B and must be matched to the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the threshold we set with you. It also keeps its filters and ductwork.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my airflow sufficient?\u003c\/strong\u003e York indicates about 350 to 450 CFM per ton of the outdoor unit, with an external static pressure of 0.2 to 0.6 in. W.C. We measure it at the visit.\u003c\/p\u003e\n\n\u003ch3\u003eA typical installation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this system, we proceed as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, custom transition if needed, and sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walk-through at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe liquid line is 3\/8 in; over a long distance, larger lines may be needed, which we include in the quote.\u003c\/p\u003e\n\n\u003ch3\u003eWhat kind of home is it for?\u003c\/h3\u003e\n\u003cp\u003eThink of the small suburban bungalow, the ground floor of a duplex or the cottage whose furnace is wedged into a narrow cabinet: these are the homes where a 17-1\/2 in coil naturally fits. An electric furnace you want to turn into a central heat pump, an old central air conditioner to replace, or window units you are tired of: the starting point changes, but the logic stays the same. We measure, we match, we install the complete system, and we tune the whole thing so the house behaves well in both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use the same refrigerant, R-454B, and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe ratings apply to the certified match, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace must offer the right width and blower.\u003c\/li\u003e\n\u003cli\u003eIf heating is your priority, talk to us and compare the matches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe matched York system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we confirm it against the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402474516772,"sku":"CTM36B5CDS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM36B5CDS1_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765674","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm36b5cds1-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}