{"product_id":"serpentin-devaporateur-york-ctm42c5ces1-a-3-5-tonnes","title":"YORK CTM42C5CES1 Evaporator A-Coil | 3.5 Tons","description":"\u003ch2\u003eYork CTM42C5CES1: the 3.5-ton cased coil, a slim 21 in wide, for the furnace in a mid-size home\u003c\/h2\u003e\n\u003cp\u003eYou are looking at the page for the \u003cstrong\u003eYork CTM42C5CES1 coil\u003c\/strong\u003e because a quote, a technician or your own research brought you to this model number. Here is what you need to know before saying yes: what this part does, what it asks of your furnace, what it cannot do on its own, and how we install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eIn two sentences\u003c\/h3\u003e\n\u003cp\u003eIt is a finned heat exchanger, mounted in an insulated cabinet, that sits on top of the furnace. It receives R-454B refrigerant from the outdoor unit and draws the cooling (or, with a heat pump, the heating) that the blower then sends through your ductwork.\u003c\/p\u003e\n\n\u003ch3\u003e3.5 tons: what size of home is it for?\u003c\/h3\u003e\n\u003cp\u003eThe nominal size is 3.5 tons, or 42,000 BTU\/h. In the CTM range we are looking at here, it is the smallest of the three models, and it is also the one that asks the least of the blower. It suits a well-insulated bungalow, a semi-detached home or a two-storey house with rooms of ordinary size. For a very large two-storey home, or a house with many windows poorly shielded from the afternoon sun, the question of moving up to the next size comes up.\u003c\/p\u003e\n\u003cp\u003eWe never settle this choice at a glance. During the visit, we assess the home's heat loss and heat gain, then compare the result with the coil size. A unit that is too big keeps shutting off and restarting, which leaves the air humid; a unit that is too small never catches up with a July heat wave.\u003c\/p\u003e\n\n\u003ch3\u003eThe 21 in width, your first check\u003c\/h3\u003e\n\u003cp\u003eThis model measures 21 in wide and 28-3\/4 in high. That width is the same as the CTM48C5CFS1, but narrower than the CTM48D5CFS1. Why does it matter? Because the cabinet sits directly on the furnace, and the two must line up so that air passes through without leaks.\u003c\/p\u003e\n\u003cp\u003eWhen the furnace is wider or narrower, that is no reason to give up on the project. We measure the plenum and, where needed, build an insulated transition cut on site. It is routine sheet-metal work in our installations.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the three models in the series\u003c\/h3\u003e\n\u003cp\u003eHere is how we present the series to a customer who is undecided, sticking to the published data:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTM42C5CES1\u003c\/strong\u003e (this page): 3.5 tons, 21 in wide, TXV, R-454B;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48C5CFS1\u003c\/strong\u003e: 4 tons, also 21 in wide, TXV, R-454B, with a published match to the HH836E2S11 outdoor unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48D5CFS1\u003c\/strong\u003e: 4 tons, but 24-1\/2 in wide, TXV, R-454B.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe reading is simple. If your furnace is 21 in wide and the home is mid-size, the CTM42C5CES1 is the natural candidate. If your cooling needs go up a notch, the CTM48C5CFS1 keeps the same footprint. If your furnace cabinet is wider, the CTM48D5CFS1 saves us from building a transition. All three are cased, use the same refrigerant and have the same metering device: the difference comes down to size and width.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the TXV does inside the cabinet\u003c\/h3\u003e\n\u003cp\u003eThe metering device on this coil is a TXV, a thermostatic expansion valve. It doses the liquid refrigerant entering the tubes according to the heat actually absorbed at the outlet. The result: the coil works with the right amount of refrigerant, whether the day is mild or sweltering. It is a component you will never see, but its precise adjustment is part of commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it goes: upflow, downflow, horizontal\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer publishes this coil as multi-position: upflow, downflow, horizontal left or right. In other words, it follows the furnace, whether the furnace blows upward in a basement, downward in an attic or sideways in a crawl space. An A shape, with two sloped faces that meet at the top, adapts to these positions thanks to its condensate pan.\u003c\/p\u003e\n\u003cp\u003eThe pan collects the water the coil pulls from the humid summer air and directs it to the drain. We connect this drain with care, because poor drainage is the classic cause of water damage near a furnace.\u003c\/p\u003e\n\n\u003ch3\u003eA heat pump on a furnace: how it works in your home\u003c\/h3\u003e\n\u003cp\u003eThe CTM42C5CES1 does not heat on its own. Paired with a York heat pump of the same capacity, it becomes the indoor half of a system that cools in summer and heats in winter. With a simple central air conditioner, you only get cooling.\u003c\/p\u003e\n\u003cp\u003eThe furnace does not go away. It keeps its blower, its filters and its ductwork. When the outdoor air gets too cold for the heat pump to be enough, the furnace takes over, at a threshold we program with you. If your current heating is electric, adding a heat pump reduces the share of heat produced by pure resistance: in mild temperatures, the heat pump delivers two to three times more heat than the electricity it consumes.\u003c\/p\u003e\n\n\u003ch3\u003eR-454B and the built-in safety\u003c\/h3\u003e\n\u003cp\u003eThe coil runs on R-454B refrigerant, rated A2L. For that reason, York factory-mounts a leak sensor (code S) on the coil plate, connected to the RDS control board. If the detected level exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan starts to circulate the air. This protection is a requirement of the refrigerant, and there is nothing for you to adjust.\u003c\/p\u003e\n\u003cp\u003ePractical consequence: the coil is matched with an outdoor unit that uses the same refrigerant, and the two are installed together. Keeping your old air conditioner is therefore generally not possible.\u003c\/p\u003e\n\n\u003ch3\u003eSpec sheet, in plain language\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer and range: York, CTM series, model CTM42C5CES1;\u003c\/li\u003e\n\u003cli\u003eType: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal size: 3.5 tons, or 42,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eDimensions (W × H): 21 × 28-3\/4 in;\u003c\/li\u003e\n\u003cli\u003eNet weight: 62 lb, which is easy to handle on a plenum;\u003c\/li\u003e\n\u003cli\u003eConnections: liquid 3\/8 in, suction 7\/8 in;\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,400 CFM;\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAirflow: the blower's job\u003c\/h3\u003e\n\u003cp\u003eA coil, even a perfectly chosen one, gives poor results if the blower does not push enough air through it. Before ordering, we check the blower's capacity, the plenum space and the condition of the return air. A clogged filter or a return that is too narrow costs you in comfort and noise.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency ratings: read the AHRI number\u003c\/h3\u003e\n\u003cp\u003eThis coil has no efficiency rating of its own. The published ratings belong to the matched, certified system. Before placing an order, we confirm the AHRI number of the match, so that the figures in your quote are the ones you will actually get. If you are comparing two offers, ask each contractor for this number.\u003c\/p\u003e\n\n\u003ch3\u003eRebates and LogisVert\u003c\/h3\u003e\n\u003cp\u003eEligibility for rebates, including those under LogisVert and Hydro-Québec, depends on the complete system and not on the coil alone. We check the official list at the time of the quote, based on the installation date, and we tell you clearly what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our work is done under RBQ licence 5645-9605-01. For this coil and its outdoor unit, the visit and the installation follow this order:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet on the plenum, custom transition if needed, sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walkthrough at the house.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuestions we are often asked\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally no: the coil is designed for R-454B and for the outdoor unit specified by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs my furnace still useful?\u003c\/strong\u003e Yes, it serves as backup heating for the coldest days.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the coil alone eligible?\u003c\/strong\u003e No, eligibility is judged on the matched system.\u003c\/p\u003e\n\n\u003ch3\u003eNext step: an on-site estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate: we come to your home, measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402474549540,"sku":"CTM42C5CES1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM42C5CES1_00_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765673","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm42c5ces1-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}