{"product_id":"serpentin-devaporateur-york-ctm48c5cfs1-a-4-tonnes","title":"YORK CTM48C5CFS1 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eYork CTM48C5CFS1: a 4-ton coil whose certified HH836E2S11 match is already published\u003c\/h2\u003e\n\u003cp\u003eSome coils arrive with no numbers to back them up; this one has its own. The \u003cstrong\u003eYork CTM48C5CFS1\u003c\/strong\u003e is a 4-ton cased coil, 21 in wide, with a named outdoor partner: the \u003cstrong\u003eHH836E2S11\u003c\/strong\u003e heat pump. This pair has a published AHRI number, capacities and ratings. This page helps you read those figures and check that the part suits your furnace, whether you live in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eReading the system sheet: the numbers that matter\u003c\/h3\u003e\n\u003cp\u003eTaken together, the CTM48C5CFS1 and the HH836E2S11 outdoor unit form a system certified under AHRI number 214606575. The published values are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecooling: 31,600 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eheating: 30,800 BTU\/h at 47 °F;\u003c\/li\u003e\n\u003cli\u003esystem ratings: SEER2 \/ HSPF2 of 15.2 \/ 8.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese ratings describe the whole assembly, not the coil on its own. When a quote promises you a SEER2 or an HSPF2, ask for the AHRI number: it is what proves the two parts were tested together. Yours is this one.\u003c\/p\u003e\n\n\u003ch3\u003eWhy talk about 4 tons when the published capacity is lower?\u003c\/h3\u003e\n\u003cp\u003eThe coil's nominal size is 4 tons, or 48,000 BTU\/h. The capacities of the matched system, for their part, come from the chosen outdoor unit and the test conditions. This is a normal distinction in the industry: the coil is sized to allow a comfortable airflow, while the system's capacity comes from the complete match. If this point puzzles you, ask about it during the visit; we will show you in the AHRI directory.\u003c\/p\u003e\n\n\u003ch3\u003e21 in wide, a cabinet 33 in high\u003c\/h3\u003e\n\u003cp\u003eThe dimensions (W × H) are 21 × 33 in, with a net weight of 73 lb. The assembly installs on an upflow furnace, but also in downflow or horizontal, left or right, since York publishes it as multi-position. The shape is that of an A: two sloped faces that meet, with air passing through them as it rises from the furnace.\u003c\/p\u003e\n\u003cp\u003eThe cabinet is insulated and delivered ready to install, which saves us from improvising an enclosure on site. The 21 in width has to match the furnace cabinet; if not, we build an insulated transition.\u003c\/p\u003e\n\n\u003ch3\u003eCompared with its two neighbours in the series\u003c\/h3\u003e\n\u003cp\u003eTo know whether you are in the right place, compare three spec sheets:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTM42C5CES1\u003c\/strong\u003e: 3.5 tons, 21 in, TXV, R-454B; the smallest size in the series, with no named outdoor unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48C5CFS1\u003c\/strong\u003e (this page): 4 tons, 21 in, TXV, R-454B, with the HH836E2S11 unit already matched;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48D5CFS1\u003c\/strong\u003e: 4 tons, 24-1\/2 in, TXV, R-454B, for a wider furnace cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CTM48C5CFS1 is therefore the right choice if your furnace is 21 in wide and the home needs more than the 3.5-ton offers. Its one distinguishing feature on paper is the certified match that can be cited by number. If your furnace is wider, the D saves the transition.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil actually does\u003c\/h3\u003e\n\u003cp\u003eThink of a radiator placed in the home's airstream. In summer, the refrigerant evaporates in its tubes, absorbs heat from the passing air and carries it outside; the condensed water drops into a pan connected to the drain, which also dries the indoor air. In winter, with a heat pump, the cycle reverses and the coil gives up to the air the heat captured by the outdoor unit.\u003c\/p\u003e\n\u003cp\u003eThe furnace, with its blower, filters and ductwork, stays where it is. It takes over when the cold goes beyond what the heat pump can reasonably supply, at the threshold we set with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe TXV and the A2L sensor\u003c\/h3\u003e\n\u003cp\u003eA thermostatic expansion valve (TXV) modulates the refrigerant supply according to the load. R-454B, for its part, is an A2L refrigerant: York therefore factory-installs a sensor mounted on the coil plate and connected to the RDS control board. Above 15% of the LFL, the call to the compressor is interrupted and the indoor fan switches on. Both devices are standard; all you have to do is entrust their setup to a competent installer.\u003c\/p\u003e\n\n\u003ch3\u003eFull technical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CTM48C5CFS1, York CTM range;\u003c\/li\u003e\n\u003cli\u003etype: cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003enominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003e3\/8 in liquid connection and 7\/8 in suction connection;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 1,600 CFM;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty, per YORK brochure PUBL-8373-B-0324;\u003c\/li\u003e\n\u003cli\u003ereference manual for leak detection: 6356510-UIM-C-0824.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eBlower, plenum, returns: the checks that come before the order\u003c\/h3\u003e\n\u003cp\u003eAn airflow of 1,600 CFM requires a blower able to deliver it without struggling. A clogged filter or a restricted return can freeze the coil or leave rooms lukewarm. At the visit, we inspect the blower, measure the plenum and examine the returns before confirming that this model is the right one.\u003c\/p\u003e\n\u003cp\u003eOne basic rule to add: the coil is matched with an outdoor unit that runs on the same refrigerant, installed at the same time. Keeping an old air conditioner is therefore generally not an option.\u003c\/p\u003e\n\n\u003ch3\u003eComparing two quotes without getting lost\u003c\/h3\u003e\n\u003cp\u003eA serious quote names the coil, the outdoor unit and the AHRI number. If any of the three is missing, you cannot verify what you are being offered. With the CTM48C5CFS1 and the HH836E2S11, the check takes a few minutes: you enter the number in the directory and read the same figures as the ones in this text.\u003c\/p\u003e\n\u003cp\u003eAlso ask who handles the vacuum, the leak test and the airflow adjustment. These steps cannot be seen once the walls are closed up, but they decide the system's lifespan. With us, they are included in the work and recorded in the file.\u003c\/p\u003e\n\u003cp\u003eFinally, look at the warranty: the manufacturer's is limited to 10 years on parts, per the brochure cited above. It covers parts, not labour, which is why choosing an established installer in Montreal or its surrounding area matters as much as choosing the equipment.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe York system matched this way appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation; we do not state it in advance. We validate it on the official list at the time of the quote and put together the LogisVert application with you.\u003c\/p\u003e\n\n\u003ch3\u003eHow we install\u003c\/h3\u003e\n\u003cp\u003eAirGreen, a family-run heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01. For this complete system, the usual sequence is:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace and checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the cabinet in the plenum, custom transition if necessary, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003esetting the outdoor unit, brazed piping, nitrogen test, vacuum;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations given on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this coil heat?\u003c\/strong\u003e Yes, if it is paired with a heat pump; with a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is not 21 in wide. So what?\u003c\/strong\u003e We measure and build an insulated transition if needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes my furnace become useless?\u003c\/strong\u003e No, it keeps its backup role in extreme cold.\u003c\/p\u003e\n\n\u003ch3\u003eGetting your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402475925796,"sku":"CTM48C5CFS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM48C5CFS1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765676","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm48c5cfs1-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}