{"product_id":"serpentin-devaporateur-york-ctm48d5cfs1-a-4-tonnes","title":"YORK CTM48D5CFS1 Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eYork CTM48D5CFS1: a 4-ton coil in a 24-1\/2 in wide cabinet for larger furnaces\u003c\/h2\u003e\n\u003cp\u003eIn York's CTM series, the \u003cstrong\u003eCTM48D5CFS1\u003c\/strong\u003e is the one you choose when the furnace is wide. At 24-1\/2 in, this 4-ton cased coil takes up more space than its two neighbours, but it fits large cabinets better with no tinkering. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, most often in two-storey homes or large bungalows.\u003c\/p\u003e\n\n\u003ch3\u003eVisit day: what we measure first\u003c\/h3\u003e\n\u003cp\u003eWhen we arrive at a customer's home who is considering this model, the first thing we take out is a tape measure. We record the width of the furnace cabinet, the height available above the plenum and the room around it to work. The coil measures 24-1\/2 × 32-3\/4 in; it therefore has to fit on the furnace without touching the ceiling or blocking access to the filter.\u003c\/p\u003e\n\u003cp\u003eNext come the blower and the return air. The nominal airflow is 1,600 CFM, and the blower must sustain it without straining. A return that is too narrow shows up as noise, uneven rooms and, in the worst case, a coil covered in frost.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 24-1\/2 in rather than 21 in?\u003c\/h3\u003e\n\u003cp\u003eThe series comes in two widths. Here are the three spec sheets side by side:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCTM42C5CES1\u003c\/strong\u003e: 3.5 tons, 21 in, TXV, R-454B;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48C5CFS1\u003c\/strong\u003e: 4 tons, 21 in, TXV, R-454B, published match with the HH836E2S11 unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCTM48D5CFS1\u003c\/strong\u003e (this one): 4 tons, 24-1\/2 in, TXV, R-454B.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace cabinet measures 24-1\/2 in or close to it, this model saves us from connecting a transition piece. If your furnace is narrower, the CTM48C5CFS1 gives the same nominal capacity in a slimmer size. And if the home is modest, the CTM42C5CES1 may be enough. Note that, for the D, no specific outdoor unit is named in our data: we confirm the match and its AHRI number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eAn 80 lb unit: plan for handling\u003c\/h3\u003e\n\u003cp\u003eThe net weight is 80 lb. That is not excessive, but it is enough that we plan for two people when the plenum is up high, above a basement furnace with a narrow staircase. The cabinet is insulated and ready to install, which cuts time on site and improves the seal between the furnace and the coil.\u003c\/p\u003e\n\n\u003ch3\u003eThe A shape and the possible positions\u003c\/h3\u003e\n\u003cp\u003eTwo sloped faces, joined at the top, form the letter A. Air from the furnace passes through both faces before heading to the ductwork. York publishes this model as multi-position: upflow, downflow, horizontal left or right. Whether your furnace blows up, down or flat, there is a configuration.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a coil does in a real home\u003c\/h3\u003e\n\u003cp\u003ePicture a suburban two-storey home, with an upstairs bedroom that overheats in August while the living room stays cool. A properly sized coil, combined with an adequate blower and ductwork in good condition, distributes the air better. It does not fix everything: if the upstairs ducts are poorly insulated or unbalanced, we say so and propose corrections.\u003c\/p\u003e\n\u003cp\u003eIn summer, the coil cools and dries the air. In winter, with a heat pump, it releases the heat captured outside. The furnace then keeps a backup role for the coldest days, at a threshold we program with you.\u003c\/p\u003e\n\n\u003ch3\u003eA large cabinet: does that also mean an older furnace?\u003c\/h3\u003e\n\u003cp\u003eNot necessarily, but it happens. Many large electric furnaces in North Shore and South Shore homes have a generous cabinet, built to house big heating elements and a sturdy blower. That space is an asset: it easily accepts a 24-1\/2 in cabinet and leaves room for the piping connections, which we braze with care.\u003c\/p\u003e\n\u003cp\u003eIf the furnace is old, we take the opportunity to examine the condition of the blower, the filter and the neighbouring ducts. It is better to know before installing than to find out about an insufficient return air on the first day of a heat wave. And if a part of the system deserves replacing, we tell you frankly, with the options.\u003c\/p\u003e\n\u003cp\u003eOne last job-site detail: the condensate drain. On a model of this size, the amount of water collected in summer can be significant on humid days. We plan a drain run that slopes down clearly and can be inspected, rather than hiding it behind a wall.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel CTM48D5CFS1, CTM series, York;\u003c\/li\u003e\n\u003cli\u003ecased evaporator coil, TXV metering device;\u003c\/li\u003e\n\u003cli\u003e4 tons, or 48,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eW × H dimensions of 24-1\/2 × 32-3\/4 in;\u003c\/li\u003e\n\u003cli\u003enet weight of 80 lb;\u003c\/li\u003e\n\u003cli\u003e3\/8 in (liquid) and 7\/8 in (suction) connections;\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant;\u003c\/li\u003e\n\u003cli\u003e10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eR-454B refrigerant and its leak sensor\u003c\/h3\u003e\n\u003cp\u003eR-454B is rated A2L. York therefore factory-mounts a sensor (code S) on the coil plate, connected to the RDS control board. When the concentration exceeds 15% of the LFL, the call to the compressor is cut and the indoor fan is started (manual 6356510-UIM-C-0824). It is a built-in protection, with no adjustment on your part.\u003c\/p\u003e\n\u003cp\u003eSince the coil requires the same refrigerant as the outdoor unit, both must be replaced together. Your old air conditioner generally cannot be kept.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency ratings: what to know\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own; the published ratings belong to the matched system. We confirm the AHRI number before purchase, then write it into the quote, so that you can compare equivalent offers.\u003c\/p\u003e\n\n\u003ch3\u003eRebates\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs, including LogisVert, judge eligibility on the complete system, never on the coil alone. We check the official list on the date of the quote and tell you what applies to your file.\u003c\/p\u003e\n\n\u003ch3\u003eOur work, start to finish\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. A typical installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet on the plenum, with sealed duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walkthrough.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuick answers\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this model heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace is narrower?\u003c\/strong\u003e We build an insulated transition on site.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still used?\u003c\/strong\u003e Yes, as backup when it gets very cold outside.\u003c\/p\u003e\n\n\u003ch3\u003eLet's work out the numbers for your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402449580324,"sku":"CTM48D5CFS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM48D5CFS1_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765676","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm48d5cfs1-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}