{"product_id":"serpentin-devaporateur-york-ctm60c5chs1-a-5-tonnes","title":"YORK CTM60C5CHS1 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCTM60C5CHS1: a York 5-ton coil, 21 in wide by 39 in tall\u003c\/h2\u003e\n\u003cp\u003eWhen a furnace is narrow but the plenum offers some height, the \u003cstrong\u003eYork CTM60C5CHS1 coil\u003c\/strong\u003e comes into play. It shares the 21 in width of the CTM60C5CGS1, but its cabinet is 39 in tall and its net weight reaches 78 lb. It is a small air-handling detail that changes the job-site visit, and we explain it here without jargon.\u003c\/p\u003e\n\u003cp\u003eOur team installs this type of coil in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, mostly in homes where electric heating or an old central air conditioner is giving way to a heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eVertical clearance, the first question of the visit\u003c\/h3\u003e\n\u003cp\u003eWith published dimensions of 21 × 39 in (width × height), this cabinet needs room above the furnace. We therefore measure the space between the top of the unit and the ceiling of the mechanical room, as well as the path of the supply plenum. If a few inches are missing, we adapt the transition rather than sacrifice access to the filter or the drain.\u003c\/p\u003e\n\u003cp\u003eIf your furnace has a different width, we build an insulated transition on site; this is a common job and does not force you to change your furnace.\u003c\/p\u003e\n\n\u003ch3\u003eOne coil, one cabinet, a promise of simplicity\u003c\/h3\u003e\n\u003cp\u003eThe CTM60C5CHS1 is a cased coil. Everything is factory-mounted: the coil, its insulated enclosure, and its 3\/8 in (liquid) and 7\/8 in (suction) connections. On site, the installation comes down to connecting, sealing and checking. The metering device is a TXV, and the coil accepts several positions: upflow, downflow, horizontal left or right.\u003c\/p\u003e\n\n\u003ch3\u003eA single published pairing: the HH860E2S11\u003c\/h3\u003e\n\u003cp\u003eUnlike some of its siblings, this coil is published with a single York outdoor unit, the \u003cstrong\u003eHH860E2S11\u003c\/strong\u003e. The AHRI number of the system is 214606530. Its ratings are SEER2 15.2, HSPF2 8.1.\u003c\/p\u003e\n\u003cp\u003eThis heating rating belongs to the complete system, not to the coil itself. It serves as an honest benchmark when you compare: an HSPF2 figure only means something when it comes with the right AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eHow does it compare with the other coils in the series?\u003c\/h3\u003e\n\u003cp\u003eAll the models in the group are York 5-ton coils using R-454B, with a TXV, paired with the HH860E2S11. Here is how to tell the CTM60C5CHS1 apart.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTM60C5CGS1:\u003c\/strong\u003e same 21 in width. The latter is published with two outdoor units, whereas the CHS1 has only one. Look at the cabinet height your room allows before deciding.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAgainst the CTM60D5CGS1, CTM60D5CHS1 and CTM60D5CJS1:\u003c\/strong\u003e these three are 24-1\/2 in wide. If your furnace is narrower, they call for a more generous transition.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOn ratings:\u003c\/strong\u003e each model has its own AHRI number. Ours is 214606530; always confirm it in the quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the coil changes day to day\u003c\/h3\u003e\n\u003cp\u003eIn summer, the heat and humidity of the indoor air are captured by the coil and the water runs off to the drain. The cool air comes out of the same vents that used to carry the heating. You no longer buy a window air conditioner for each bedroom.\u003c\/p\u003e\n\u003cp\u003eIn winter, with the heat pump, the cycle reverses. The furnace stays there, with its blower, its filters and its heating elements. It takes over when the outdoor temperature falls below the threshold we set with you, which protects you against deep cold without making the heat pump struggle.\u003c\/p\u003e\n\n\u003ch3\u003eThe A2L sensor, in two sentences\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant. York installs a sensor (code S) at the factory on the coil plate, wired to the RDS control board. Above 15% of the LFL, the compressor stops receiving its call and the indoor fan starts. The manufacturer's installation manual, reference 6356510-UIM-C-0824, details how this works.\u003c\/p\u003e\n\n\u003ch3\u003eThree scenarios where the CTM60C5CHS1 makes sense\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe electric furnace you want to keep.\u003c\/strong\u003e Many homeowners on the South Shore or in Laval have an electric furnace that still works. Adding the heat pump and this coil avoids replacing everything: the cost is concentrated on the outdoor unit and the coil, and the furnace moves into a backup role.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe old central air conditioner at the end of its life.\u003c\/strong\u003e If the original compressor is near the end, replacing the whole set with an R-454B system makes more sense than repairing old equipment whose refrigerant is getting harder to find.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe addition that made the house too big for its system.\u003c\/strong\u003e After an extension or a finished basement, the original capacity no longer keeps up. The 5-ton size answers that need, provided the ductwork can deliver the airflow.\u003c\/p\u003e\n\n\u003ch3\u003eSummary spec sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: CTM60C5CHS1, CTM series;\u003c\/li\u003e\n\u003cli\u003enominal size: 5 tons, 60,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21 × 39 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 78 lb;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 1,800 CFM;\u003c\/li\u003e\n\u003cli\u003ewarranty: 10-year limited parts warranty (YORK brochure PUBL-8373-B-0324).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy put a 5-ton system in your home\u003c\/h3\u003e\n\u003cp\u003eThe 5-ton size suits large homes, finished basements and extensions. At this size, the electrical entrance and the airflow become the two points to validate. We sometimes recommend two smaller systems rather than one big one; we would rather tell you at the visit than after the installation.\u003c\/p\u003e\n\u003cp\u003eYork, a Johnson Controls brand distributed in Quebec by Groupe Master, builds into its CTF, CTM and CTU coils using R-454B the leak-detection sensor and control that this refrigerant requires. The HH8 heat pumps are variable-speed and ENERGY STAR certified for Canada and the United States.\u003c\/p\u003e\n\n\u003ch3\u003eThe AirGreen installation, step by step\u003c\/h3\u003e\n\u003cp\u003eA family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. Here is how the job unfolds:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the joints;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed line set, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations in your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eYear-round comfort, seen from the inside\u003c\/h3\u003e\n\u003cp\u003eA well-tuned central system makes itself forgotten, and that is a good sign. Rooms even out, the thermostat controls a single installation, and the treated air circulates through the vents you already know. In the warm season, the air sheds its moisture; in the cold season, the heat arrives through the same grilles, without the surges of an electric baseboard heater switching on and off.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe height available for a 39 in cabinet.\u003c\/li\u003e\n\u003cli\u003eThe width of the furnace compared with the 21 in of the coil.\u003c\/li\u003e\n\u003cli\u003eA pairing with an R-454B outdoor unit, installed at the same time as the coil.\u003c\/li\u003e\n\u003cli\u003eThe ability of the blower to deliver the airflow of the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your file: we check it against the official list at the time of the quote and prepare the application with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402474582308,"sku":"CTM60C5CHS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM60C5CHS1_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765677","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm60c5chs1-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}