{"product_id":"serpentin-devaporateur-york-ctm60d5cjs1-a-5-tonnes","title":"YORK CTM60D5CJS1 Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eCTM60D5CJS1: how to read the quote for a York 5-ton coil\u003c\/h2\u003e\n\u003cp\u003eTwo quotes on the table, two lists of numbers that look alike. The \u003cstrong\u003eYork CTM60D5CJS1 coil\u003c\/strong\u003e, a 5-ton R-454B cabinet 24-1\/2 in wide, deserves to have you learn how to read what you are being offered. This guide is for homeowners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e who want to compare methodically.\u003c\/p\u003e\n\n\u003ch3\u003eFirst point: the exact model\u003c\/h3\u003e\n\u003cp\u003eCTM60D5CJS1: the CTM series, the 5-ton size (60,000 BTU\/h), a specific cabinet version. A neighbouring coil with a different letter at the end is not necessarily identical: weight, height or pairing can vary. Here, the published dimensions are 24-1\/2 × 37-1\/4 in and the net weight is 83 lb.\u003c\/p\u003e\n\n\u003ch3\u003eSecond point: the AHRI number\u003c\/h3\u003e\n\u003cp\u003eThis is the most important one. For this coil paired with the York HH860E2S11 unit, the number is 214606519, and the system ratings are SEER2 15.2, HSPF2 8.5. A different number designates a different set. The ratings belong to the system and not to the coil: if a quote shows no number, ask for it.\u003c\/p\u003e\n\n\u003ch3\u003eThird point: the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe CTM60D5CJS1 is published with a single unit, the HH860E2S11, a York R-454B heat pump with a variable-speed compressor, certified ENERGY STAR for Canada and the United States. A coil cannot be paired with just any air conditioner: the refrigerant must be the same, and the whole set is installed in one go.\u003c\/p\u003e\n\n\u003ch3\u003eFourth point: the metering device\u003c\/h3\u003e\n\u003cp\u003eThis model uses a TXV. This small component doses the refrigerant at the coil inlet according to the load. In a serious quote, it is mentioned; if it is missing, ask the question.\u003c\/p\u003e\n\n\u003ch3\u003eFifth point: the width of the furnace\u003c\/h3\u003e\n\u003cp\u003eThe coil is 24-1\/2 in wide. We check the furnace before ordering, and if the width differs, we build an insulated transition on site. A quote that mentions neither a measurement nor a transition deserves a second look.\u003c\/p\u003e\n\n\u003ch3\u003eShould you prefer it over its four neighbours?\u003c\/h3\u003e\n\u003cp\u003eIt belongs to a series of five York 5-ton coils using R-454B, with a TXV, all associated with the HH860E2S11.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSame 24-1\/2 in width: CTM60D5CGS1 and CTM60D5CHS1.\u003c\/li\u003e\n\u003cli\u003eNarrower, at 21 in: CTM60C5CGS1 and CTM60C5CHS1.\u003c\/li\u003e\n\u003cli\u003eA single published outdoor unit for this model, as for the CTM60D5CHS1; the CTM60C5CGS1 and CTM60D5CGS1 have two.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace matches 24-1\/2 in and you are aiming for the HH860E2S11, you are squarely in this model's territory. For the rest, the comparison is made by AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eSixth point: what stays in your home\u003c\/h3\u003e\n\u003cp\u003eThe blower, the filters and the existing ducts are kept. The furnace becomes backup heat below the temperature threshold we set with you. The coil does not reuse an old air conditioner: R-454B requires the manufacturer's outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eSeventh point: the warranty and the documentation\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer's warranty is a 10-year limited parts warranty, per YORK brochure PUBL-8373-B-0324. The reference installation manual is 6356510-UIM-C-0824. Keep these numbers: they help when a technician needs to find the right documentation.\u003c\/p\u003e\n\n\u003ch3\u003eThree common mistakes when comparing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComparing ratings without an AHRI number.\u003c\/strong\u003e A SEER2 or HSPF2 shown without a certification number proves nothing. It may come from another pairing, or even another coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eForgetting that the furnace works too.\u003c\/strong\u003e The coil adds resistance to the passage of air. The blower must be able to overcome it while delivering the airflow of the system. We check this point during the visit and we adjust the airflow at commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThinking that bigger is always better.\u003c\/strong\u003e A 5-ton size is meant for large homes. In an average home, it would be too much; we prefer to say so and propose a smaller size or two systems.\u003c\/p\u003e\n\n\u003ch3\u003eTwo home profiles where it makes sense\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe large electric furnace.\u003c\/strong\u003e A homeowner in Laval or on the North Shore whose electric furnace is still sound can keep it as backup and benefit from a heat pump for most of the season. The coil is the link that makes this combination possible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe central air conditioner to replace.\u003c\/strong\u003e In a home in Longueuil or Montreal whose old air conditioner is giving up, this new system replaces the whole set at once and avoids repairing equipment whose parts are getting scarce.\u003c\/p\u003e\n\u003cp\u003eIn both cases, we measure before proposing, and we give you a written quote that states the model, the AHRI number and the outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does, in concrete terms\u003c\/h3\u003e\n\u003cp\u003eIn an add-on system, it fits into the plenum, in the path of the air. In summer, the refrigerant evaporates in the tubes and captures heat; the condensation water is collected in the pan. In winter, with a heat pump, the cycle reverses and the heat is delivered to the air of the house. It accepts several positions: upflow, downflow, horizontal left or right.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in leak detection\u003c\/h3\u003e\n\u003cp\u003eBecause R-454B is an A2L refrigerant, York installs a sensor at the factory (code S) on the coil plate, wired to the RDS board. Above 15% of the LFL, the call to the compressor is cut and the indoor fan is started. Connections: 3\/8 in liquid, 7\/8 in suction. Nominal airflow: 1,800 CFM.\u003c\/p\u003e\n\n\u003ch3\u003eA word on the comfort you will get from it\u003c\/h3\u003e\n\u003cp\u003eWith a central system, a single outdoor unit serves the whole house. Cool air circulates in every room through the existing ducts, humidity drops and July heat becomes more bearable. In the cold season, the heat pump provides most of the heating and the furnace stays ready for deep cold. A single thermostat controls both seasons, which simplifies daily life.\u003c\/p\u003e\n\n\u003ch3\u003eOur work in your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01. The project follows five steps:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasurements of the furnace, the blower and the panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum and sealing the connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit, brazed line set, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and explanations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYork is a Johnson Controls brand, distributed in Quebec by Groupe Master.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe AHRI number 214606519 written on the quote.\u003c\/li\u003e\n\u003cli\u003eR-454B on both sides of the system.\u003c\/li\u003e\n\u003cli\u003eThe width of the furnace and the capacity of the blower.\u003c\/li\u003e\n\u003cli\u003eThe electrical entrance for the outdoor unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp\u003eThe paired York system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your file: we check it against the official list at the time of the quote and prepare the application with you. Eligibility is tied to the complete system.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete York system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":68402474647844,"sku":"CTM60D5CJS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_YORK_CTM_CTM60D5CJS1_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765677","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-york-ctm60d5cjs1-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}