{"product_id":"serpentin-devaporateur-zephyr-dc31d2j-a-2-tonnes","title":"ZEPHYR DC31D2J Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eDC31D2J: the 2-ton Zephyr evaporator coil for a small home's furnace\u003c\/h2\u003e\n\u003cp\u003eIn a Verdun townhouse or a plex unit in Longueuil, the furnace takes up one corner of the basement, and the ductwork is often short. That is exactly the setting for the \u003cstrong\u003eDC31D2J\u003c\/strong\u003e, a Zephyr cased evaporator coil with a nominal size of 2 tons, or 24,000 BTU\/h, that runs on R-454B refrigerant. It sits on top of your furnace, receives refrigerant from the ZE-624HPA outdoor unit and turns hot summer air into cool air delivered through your existing registers.\u003c\/p\u003e\n\u003cp\u003eWe install it in Montreal, Laval, Longueuil, the North Shore and the South Shore. Here is what you need to know to decide without rushing.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the smallest size in the group is not a bargain choice\u003c\/h3\u003e\n\u003cp\u003ePeople often assume a bigger machine means more comfort. For a small home, that is wrong. An oversized system reaches the requested temperature in a few minutes, shuts off, then starts again. During those short cycles, the air does not stay on the coil long enough to leave its moisture behind. The result is a room that is cool but clammy, where you feel like opening a window.\u003c\/p\u003e\n\u003cp\u003eA well-chosen 2-ton size runs longer each time. The air circulates, the coil condenses the water, the pan collects it and the drain carries it away. That is why we always start from the house, not from the catalogue.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check to confirm it is enough\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe actual floor area of the rooms served and their orientation;\u003c\/li\u003e\n\u003cli\u003ethe quality of the wall and attic insulation;\u003c\/li\u003e\n\u003cli\u003ethe number and size of the windows, especially facing south and west;\u003c\/li\u003e\n\u003cli\u003ethe condition of the existing ducts and how well sealed they are.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf that calculation points to a larger size, we will tell you frankly. A coil that is too small disappoints as much as one that is too big.\u003c\/p\u003e\n\n\u003ch3\u003eThe DC31D2J at a glance\u003c\/h3\u003e\n\u003cp\u003eThe coil is A-shaped: two sloped faces meet at the top. Air rises from the furnace, passes through both surfaces and comes out cooled. The insulated cabinet ships with the unit, which saves building an enclosure on site and limits air leaks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eManufacturer and line:\u003c\/strong\u003e Zephyr, DC line;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal capacity:\u003c\/strong\u003e 2 tons (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMetering device:\u003c\/strong\u003e TXV R-454B (J), which meters the refrigerant sent into the tubes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e 3\/8 in ODS for the liquid line, 3\/4 in ODS for the suction line;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater drainage:\u003c\/strong\u003e 3\/4 in NPT condensate drain;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNet weight:\u003c\/strong\u003e 41 lb;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePositions:\u003c\/strong\u003e upflow as standard; downflow with the DWNFLWP-175 kit, sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMatching with the ZE-624HPA outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe coil never works alone. Its published partner is the Zephyr ZE-624HPA outdoor unit, registered under AHRI number 218160013. Together they deliver 24,000 BTU\/h of cooling and, on the heat pump side, 24,000 BTU\/h of heating at 47 °F. The system ratings are 16.0 SEER2 and 8.2 HSPF2.\u003c\/p\u003e\n\u003cp\u003eKeep this in mind: these ratings describe the certified pair, never the coil on its own. When two contractors give you quotes, compare the AHRI numbers before you compare prices. That number is also the one checked for the rebate.\u003c\/p\u003e\n\u003cp\u003eZephyr also states that its R-454B matches use a continuously variable speed compressor, with a global warming potential of 470, and that they are ENERGY STAR cold climate certified for Canada.\u003c\/p\u003e\n\n\u003ch3\u003eBetween the 2-ton and its neighbours in the line\u003c\/h3\u003e\n\u003cp\u003eThe DC line has four cased coils, all on R-454B and all with a TXV R-454B (J) metering device. Only the size, the outdoor unit and, for the two largest, the published width change.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDC31D2J, 2 tons:\u003c\/strong\u003e this one, matched with the ZE-624HPA, for the smallest volumes to cool;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC37D3J, 3 tons:\u003c\/strong\u003e matched with the ZE-636HPA, for a larger home with the same furnace;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC49B3J, 4 tons:\u003c\/strong\u003e 21 in wide, matched with the ZE-648HPA;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC61C4J, 5 tons:\u003c\/strong\u003e 24-1\/2 in wide, matched with the ZE-660HPA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your home is smaller than you thought, or if the furnace has just been replaced with a more compact model, this size deserves a look first. When in doubt, we measure before deciding.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in the plenum, season by season\u003c\/h3\u003e\n\u003cp\u003eThe coil fits into the plenum, in the path of the air. In summer, the refrigerant evaporates inside its tubes and absorbs heat from the air passing through. The moisture condenses on the fins, then runs down to the drain. In winter, with a heat pump, the cycle is reversed: the outdoor unit sends hot refrigerant and the house air receives that heat.\u003c\/p\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its role as backup heating. It takes over below an outdoor temperature that we set together.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a heat pump changes for a compact home\u003c\/h3\u003e\n\u003cp\u003eElectric baseboard or electric furnace heating converts each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside; in mild weather, it returns two to three times the energy it uses. The colder it gets, the less favourable that ratio becomes, which is why keeping the furnace as backup makes sense.\u003c\/p\u003e\n\u003cp\u003eFor a small home, it is often the solution that lets you do without window air conditioners, free up the window sills and set just one thermostat.\u003c\/p\u003e\n\n\u003ch3\u003eA word on noise and daily life\u003c\/h3\u003e\n\u003cp\u003eIn a small home, the furnace is often close to the bedrooms. Because the blower and ducts are kept, you keep the habits of the house: same registers, same filters to change, same thermostat. We give you the maintenance instructions at commissioning, and we stay reachable if an airflow setting needs to be revisited after the first few weeks.\u003c\/p\u003e\n\n\u003ch3\u003eLeak detection and warranty\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant. With this family, a refrigerant detection system is required. Aspen offers the A2LZS or A2LZR kit, the latter with a relay; they can be installed at the factory or on site, and the RBL list includes the A2LZR. We explain the choice during the visit.\u003c\/p\u003e\n\u003cp\u003eThe coil is covered by a 10-year limited warranty, with registration, offered by Aspen.\u003c\/p\u003e\n\n\u003ch3\u003eOur work at your home, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a heating and cooling company based in Montreal. For the DC31D2J and the ZE-624HPA, our team:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasures the furnace, tests the blower and looks at the electrical panel;\u003c\/li\u003e\n\u003cli\u003esets the coil in the plenum, adds an insulated transition if needed and seals the joints;\u003c\/li\u003e\n\u003cli\u003einstalls the outdoor unit on a stand, brazes the piping, pressure-tests it with nitrogen, then pulls a vacuum;\u003c\/li\u003e\n\u003cli\u003econnects the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003esets the airflow and shows you how to use the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat to check before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe coil and the outdoor unit must share the same refrigerant, and we install them together;\u003c\/li\u003e\n\u003cli\u003ean old air conditioner generally cannot be reused with this coil;\u003c\/li\u003e\n\u003cli\u003ethe furnace width must be suitable; if not, we build an insulated transition on site;\u003c\/li\u003e\n\u003cli\u003ethe blower must be able to supply the expected airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eEligibility is judged on the complete system, not on the coil alone. We check the official Hydro-Québec list on the date of your quote, then put the file together with you. The amount depends on your situation and the installation date; we do not promise it in advance.\u003c\/p\u003e\n\n\u003ch3\u003eNext step: a free visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate. We measure the furnace, look at the electrical service and give you a written quote for the complete Zephyr system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":68400985768228,"sku":"DC31D2J","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ZEPHYR_DC_DC31D2J_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722139","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-zephyr-dc31d2j-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}