{"product_id":"serpentin-devaporateur-zephyr-dc37d3j-a-3-tonnes","title":"ZEPHYR DC37D3J Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eFrom the first call to commissioning: the DC37D3J, a 3-ton Zephyr evaporator coil\u003c\/h2\u003e\n\u003cp\u003eMany homeowners write to us with the same message: \"I have a furnace in the basement, an old air conditioner that is running out of breath, and I would like to understand what is ahead.\" This page therefore follows the course of a real project with the \u003cstrong\u003eZephyr DC37D3J evaporator coil\u003c\/strong\u003e, a cased model of 3 tons (36,000 BTU\/h) on R-454B refrigerant, A-shaped, from the DC line.\u003c\/p\u003e\n\u003cp\u003eIt connects to the Zephyr ZE-636HPA outdoor unit. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eStep one: the conversation about the house\u003c\/h3\u003e\n\u003cp\u003eThe 3-ton size sits in the middle of the line, and that is often where suburban bungalows and cottages end up: furnace in the basement, ducts to every room, and window units that come back every July. Before we suggest this coil, we ask simple questions. What is the heated floor area? Where is the kitchen? Is there a finished floor under the roof?\u003c\/p\u003e\n\u003cp\u003eOnly then do we confirm the size. The DC37D3J is not our automatic answer; it is one of the four options in the line.\u003c\/p\u003e\n\n\u003ch3\u003eStep two: choosing among the four coils\u003c\/h3\u003e\n\u003cp\u003eAll cased DC models share R-454B refrigerant and the TXV R-454B (J) metering device. What varies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDC31D2J:\u003c\/strong\u003e 2 tons, ZE-624HPA unit, for small volumes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC37D3J:\u003c\/strong\u003e 3 tons, ZE-636HPA unit, the model on this page;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC49B3J:\u003c\/strong\u003e 4 tons, 21 in wide, ZE-648HPA unit;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC61C4J:\u003c\/strong\u003e 5 tons, 24-1\/2 in wide, ZE-660HPA unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer's publication gives no width for the two smallest, so we take the furnace measurements ourselves. If your home leans toward the top of the range, look at the two models above; if it is more compact, the 2-ton may be enough.\u003c\/p\u003e\n\n\u003ch3\u003eStep three: the certified match\u003c\/h3\u003e\n\u003cp\u003eThe DC37D3J coil is published with the ZE-636HPA outdoor unit, under AHRI number 218160014. As published by Zephyr, this system delivers 34,000 BTU\/h of cooling and 34,000 BTU\/h of heating at 47 °F, with 16.5 SEER2 and 8.2 HSPF2.\u003c\/p\u003e\n\u003cp\u003eBear in mind that the coil has no efficiency rating on its own. The ratings belong to the certified pair. When comparing two offers, ask for each one's AHRI number.\u003c\/p\u003e\n\u003cp\u003eZephyr states that its matched outdoor units use a continuously variable speed compressor and R-454B, whose global warming potential is 470.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the 3-ton comes up so often\u003c\/h3\u003e\n\u003cp\u003eIn the bungalow neighbourhoods of Laval, Longueuil or the North Shore, the setup repeats: an upflow furnace, ductwork already in place, a single thermostat. For these homes, adding a coil on the furnace is a measured job that requires no wall openings and no new duct runs.\u003c\/p\u003e\n\u003cp\u003eComfort also comes from consistency. One blower distributes cool or warm air to every room, including those where a wall unit would never be installed: the bedroom at the end of the hall, the basement office, the playroom. You avoid the gaps between the upper floor and the basement that irritate occupants so much.\u003c\/p\u003e\n\n\u003ch3\u003eStep four: the dimensions and connections to know\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: evaporator coil with insulated cabinet;\u003c\/li\u003e\n\u003cli\u003enet weight of 51 lb, which is easy to handle on a basement staircase;\u003c\/li\u003e\n\u003cli\u003eliquid line 3\/8 in ODS, suction line 3\/4 in ODS;\u003c\/li\u003e\n\u003cli\u003econdensate drain 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003eupflow installation by default, downflow with the DWNFLWP-175 kit purchased separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer does not publish a width for this model here. That is one more reason to measure at your home rather than assume.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we ask you to prepare\u003c\/h3\u003e\n\u003cp\u003eTo make the visit efficient, clear access to the furnace, locate your electrical panel and keep an old electricity bill handy if you have one. Also note the rooms that are too hot or too cold in summer; those clues guide the airflow setting. No other preparation is required from you.\u003c\/p\u003e\n\n\u003ch3\u003eStep five: A2L refrigerant safety\u003c\/h3\u003e\n\u003cp\u003eWith an A2L class refrigerant, a detection device is mandatory. Aspen offers the A2LZS and A2LZR kits; the second includes a relay. They can be mounted at the factory or on site, and the RBL list includes the A2LZR. We choose with you the kit that suits your installation.\u003c\/p\u003e\n\n\u003ch3\u003eStep six: what happens on installation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal. On installation day, we:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003echeck the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003eset the coil in the plenum, with a custom-built transition if needed, and seal the air duct connections;\u003c\/li\u003e\n\u003cli\u003esecure the outdoor unit, braze the piping, run the nitrogen leak test and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart the system, set the airflow and give you a demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the coil does, in practice\u003c\/h3\u003e\n\u003cp\u003ePlaced in the plenum, it intercepts the air leaving the blower. In summer, the refrigerant evaporates inside it, absorbs heat and the air heads to the rooms cooler; the condensation runs into the pan, then into the drain. In winter, with a heat pump, the direction is reversed and the coil gives up heat to the air.\u003c\/p\u003e\n\u003cp\u003eThe furnace keeps its blower, its filters and its backup role for very cold nights. The switchover threshold is programmed with you.\u003c\/p\u003e\n\n\u003ch3\u003eAnd on the electricity bill?\u003c\/h3\u003e\n\u003cp\u003eConventional electric heating produces as much heat as the electricity it uses. A heat pump moves heat instead of making it: in mild weather, it delivers two to three times more heat than the energy it takes in. That efficiency drops with the cold, which justifies the furnace as backup. In summer, a single system replaces window units, dries the air and is controlled from one place.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe coil is matched with an outdoor unit using the same refrigerant; the two are installed together;\u003c\/li\u003e\n\u003cli\u003ethe current air conditioner is generally not kept;\u003c\/li\u003e\n\u003cli\u003ewe measure the furnace before ordering, and build an insulated transition if the widths differ;\u003c\/li\u003e\n\u003cli\u003ethe blower must be able to supply the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThe matched system must appear on the official Hydro-Québec list; eligibility applies to the complete system and not to the coil alone. The amount depends on the installation date and on your file. We check the list at the time of the quote and prepare the application with you. The coil itself benefits from a 10-year limited warranty offered by Aspen, with registration.\u003c\/p\u003e\n\n\u003ch3\u003eAfter commissioning\u003c\/h3\u003e\n\u003cp\u003eA well-installed system needs little attention: a clean filter, a clear pan and drain, and an outdoor unit kept free of snow and leaves. We give you these instructions in writing, and we remain available to adjust the setting if a room behaves differently than expected in the first heat wave or the first deep freeze.\u003c\/p\u003e\n\n\u003ch3\u003eTaking action\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and write up a quote for the complete Zephyr system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e helps you spread the expense.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":68400985800996,"sku":"DC37D3J","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ZEPHYR_DC_DC37D3J_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722140","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-zephyr-dc37d3j-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}