{"product_id":"serpentin-devaporateur-zephyr-dc61c4j-a-5-tonnes","title":"ZEPHYR DC61C4J Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eDC61C4J: a 5-ton Zephyr coil, 24-1\/2 in wide, for a large home\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDC61C4J\u003c\/strong\u003e is the coil in the line that demands the most space and the most preparation. It is a Zephyr cased evaporator coil of 5 tons (60,000 BTU\/h) on R-454B. Its published dimensions are 24-1\/2 in wide, 32 in high and 21-1\/2 in deep, with a net weight of 72 lb. It connects to the Zephyr ZE-660HPA outdoor unit.\u003c\/p\u003e\n\u003cp\u003eWe install it in Montreal, Laval, Longueuil, the North Shore and the South Shore, mostly in homes where the air system serves many rooms.\u003c\/p\u003e\n\n\u003ch3\u003eA house that has grown over the years\u003c\/h3\u003e\n\u003cp\u003eThis size is for large properties, finished basements and homes expanded over time, where a single furnace has to serve a substantial volume. Each addition (sunroom, extra floor, converted garage) adds to the summer load, and that is the kind of situation where people turn to 5 tons.\u003c\/p\u003e\n\u003cp\u003eBefore going that high, we confirm that the real needs justify it. An oversized coil runs in short cycles and leaves the moisture in place; a size that fits is better than a size that impresses.\u003c\/p\u003e\n\n\u003ch3\u003eCapacity, electrical service and air distribution\u003c\/h3\u003e\n\u003cp\u003eThree elements must agree:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ethe capacity\u003c\/strong\u003e of the system, here 60,000 BTU\/h nominal for the coil;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ethe electrical supply\u003c\/strong\u003e of the outdoor unit, which we check at the panel;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ethe air distribution\u003c\/strong\u003e, that is, a blower and ducts able to circulate the required volume.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf one of the three falls short, the result suffers. That is why the on-site estimate is free: it exists to answer these three questions before you commit.\u003c\/p\u003e\n\n\u003ch3\u003eWeight, height and access: the logistics of the DC61C4J\u003c\/h3\u003e\n\u003cp\u003eAt 72 lb, this coil is the heaviest in the line; it takes two people to handle. Its 32 in height requires clearance above the furnace, which we measure at the visit. The insulated cabinet arrives ready to install, which limits the sheet metal work, but the staircase, the utility room door and a low ceiling can complicate handling.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eliquid connection 3\/8 in ODS, suction 7\/8 in ODS;\u003c\/li\u003e\n\u003cli\u003econdensate drain 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003eTXV R-454B (J) metering device;\u003c\/li\u003e\n\u003cli\u003eupflow position as standard; downflow with the DWNFLWP-175 kit, sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eChoosing between the 5-ton and its neighbours\u003c\/h3\u003e\n\u003cp\u003eIn the DC line, all cased coils use R-454B with the same metering device. The reference points for choosing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDC31D2J\u003c\/strong\u003e (2 tons, ZE-624HPA) and \u003cstrong\u003eDC37D3J\u003c\/strong\u003e (3 tons, ZE-636HPA): for small to medium-sized homes;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC49B3J\u003c\/strong\u003e (4 tons, 21 in wide, ZE-648HPA): the step just below, with a narrower cabinet;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDC61C4J\u003c\/strong\u003e (5 tons, 24-1\/2 in wide, ZE-660HPA): this one, for the largest volume to cool.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace is narrow or the room is tight, the 4-ton will often be simpler to install. If the house truly needs more capacity, the 5-ton is the answer, provided the furnace and blower keep up.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified system with the ZE-660HPA\u003c\/h3\u003e\n\u003cp\u003eThe AHRI number of the match is 218160016. Zephyr publishes 54,000 BTU\/h of cooling and 54,000 BTU\/h of heating at 47 °F, and SEER2 \/ HSPF2 ratings of 16.4 \/ 8.2 for the system. These ratings describe the system, not the coil alone. The AHRI number is the best reference for comparing two quotes, and it is the one checked for the rebate.\u003c\/p\u003e\n\u003cp\u003eThe outdoor units in this group use a continuously variable speed compressor and a refrigerant with a global warming potential of 470.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does in the plenum\u003c\/h3\u003e\n\u003cp\u003eAir passes from the fan through the surfaces of the coil. In summer, the refrigerant evaporates in it and absorbs heat; the water that condenses is collected, then carried away by the drain. In winter, with a heat pump, the cycle is reversed and heat is transferred to the air of the rooms. The furnace keeps its filters and its blower, and it takes over according to the outdoor temperature threshold that we set together.\u003c\/p\u003e\n\n\u003ch3\u003eIf the house is large, how do you spread the air?\u003c\/h3\u003e\n\u003cp\u003eThe larger the volume, the more distribution matters. A large home often has rooms far from the furnace, at the end of a long duct, and those are the rooms that complain first about stifling heat. We examine the system, spot the branches that are too long or too narrow and suggest adjusting the registers or correcting the most limiting sections.\u003c\/p\u003e\n\u003cp\u003eThe airflow setting at commissioning is there for exactly this: to reach a balanced result between the upper floor, the main floor and the basement, without the blower being strained.\u003c\/p\u003e\n\n\u003ch3\u003eA2L refrigerant safety\u003c\/h3\u003e\n\u003cp\u003eA refrigerant detection system is required with A2L refrigerants such as R-454B. Aspen offers the A2LZS kit and the A2LZR kit, the latter with a relay; they can be mounted at the factory or on site, and the RBL list includes the A2LZR. We help you choose according to your installation.\u003c\/p\u003e\n\n\u003ch3\u003eCosting heating differently\u003c\/h3\u003e\n\u003cp\u003eIn a large home, the heating bill is significant. Electric heating turns electricity into heat one for one; a heat pump, by contrast, moves heat and delivers two to three times more in mild weather. The efficiency decreases with the cold, which explains the furnace as backup. In summer, a single outdoor unit replaces a series of window units, and the drier air makes humid heat more bearable.\u003c\/p\u003e\n\n\u003ch3\u003eOur work, from survey to demonstration\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a heating and cooling company based in Montreal. For the DC61C4J, we:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasure the furnace and the clearance, check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstall the cabinet in the plenum, with an insulated transition if needed, and seal the joints;\u003c\/li\u003e\n\u003cli\u003eset the outdoor unit, braze the piping, test with nitrogen and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommission the system, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA word on maintenance\u003c\/h3\u003e\n\u003cp\u003eFor a coil of this size, the regularity of checks matters more than their complexity.\u003c\/p\u003e\n\u003cp\u003eA large coil collects dust like any other. A clean filter, a clear condensate pan and an outdoor unit free of snow and leaves protect the performance and the lifespan of the system. We give you simple instructions at the end of commissioning and we stay reachable for any question.\u003c\/p\u003e\n\n\u003ch3\u003eTo confirm before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ethe coil and the outdoor unit share the same refrigerant and are installed together;\u003c\/li\u003e\n\u003cli\u003ethe existing air conditioner generally cannot be reused;\u003c\/li\u003e\n\u003cli\u003ethe 24-1\/2 in width must suit the furnace, otherwise a transition is built;\u003c\/li\u003e\n\u003cli\u003ethe blower must supply the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eLogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eEligibility applies to the complete system. We check the official Hydro-Québec list on the date of the quote, and we put the file together with you; the amount depends on your situation. The coil benefits from a 10-year limited warranty offered by Aspen, with registration.\u003c\/p\u003e\n\n\u003ch3\u003eRequesting an estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and submit a written quote for the complete Zephyr system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":68400988782884,"sku":"DC61C4J","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ZEPHYR_DC_DC61C4J_00_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795722140","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-zephyr-dc61c4j-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}