{"product_id":"thermopompe-murale-tcl-ultimate-25-9000-btu","title":"TCL Ultimate 25 Wall-Mounted Heat Pump | 9000 BTU","description":"\u003ch2\u003eA 9,000 BTU Unit That Finally Solves the Room Nothing Else Can Keep Comfortable\u003c\/h2\u003e\n\u003cp\u003eThere is almost always one room in a house or condo that resists. The bedroom above the garage. The converted office that overheats in summer and turns cold in winter. The finished basement that the furnace never reaches properly. At \u003cstrong\u003eAirGreen\u003c\/strong\u003e, this is the call we receive most often, and it is exactly what the \u003cstrong\u003eTCL Ultimate 25 9,000 BTU wall-mounted heat pump\u003c\/strong\u003e is designed to handle.\u003c\/p\u003e\n\u003cp\u003eThis model is not a cheap little machine. It is the most efficient in the entire series: \u003cstrong\u003e25 SEER2\u003c\/strong\u003e, \u003cstrong\u003e14.5 EER2\u003c\/strong\u003e, \u003cstrong\u003e10.5 HSPF2\u003c\/strong\u003e, with heating operation guaranteed down to \u003cstrong\u003e-30°C\u003c\/strong\u003e. In other words, its capacity is modest because the room is; its efficiency, however, is at the top of the range.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 9,000 BTU unit actually does when it is cold\u003c\/h3\u003e\n\u003cp\u003eThe figures that matter in Quebec are not the air-conditioning figures, but the heating figures in cold weather. Here are the AHRI-certified data, as published in the NEEP cold-climate heat pump directory:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9,500 BTU\/h at 8.3°C\u003c\/strong\u003e, with a COP of 3.98\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 BTU\/h at -8°C\u003c\/strong\u003e, COP of 2.09\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9,500 BTU\/h at -15°C\u003c\/strong\u003e, COP of 1.80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6,100 BTU\/h at -30°C\u003c\/strong\u003e at maximum capacity, COP of 1.47\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFocus on the second line. At \u003cstrong\u003e-8°C\u003c\/strong\u003e—the average temperature of a January night in \u003cstrong\u003eMontreal\u003c\/strong\u003e—the unit does not lose power: it delivers more than at its rated capacity. That is the signature of an inverter compressor properly designed for a northern climate, and it is what separates a cold-climate heat pump from a catalogue appliance.\u003c\/p\u003e\n\u003cp\u003eA COP of 2.09 at -8°C means, in practical terms, that for every kilowatt of electricity consumed, you get slightly more than two kilowatts of heat. Compared with an electric baseboard heater, whose efficiency is capped at 1.0 by definition, the heating bill for this room is cut in half during the coldest part of winter, and by much more during the shoulder seasons.\u003c\/p\u003e\n\n\u003ch3\u003eThe oversizing trap, and why 9,000 BTU is enough more often than you think\u003c\/h3\u003e\n\u003cp\u003eThe mistake we correct most often on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e is not choosing a unit that is too small—it is choosing one that is too large. A homeowner is sold a 12,000 or 18,000 BTU unit “just to be safe,” and the result is always the same.\u003c\/p\u003e\n\u003cp\u003eAn oversized heat pump reaches the setpoint too quickly and then shuts off. In cooling mode, it does not have time to remove moisture from the air: the room is cold but damp, and the occupant lowers the setpoint even further. In heating mode, it operates in bursts instead of modulating smoothly, which wears out the compressor and creates noticeable temperature swings. Comfort decreases while consumption increases.\u003c\/p\u003e\n\u003cp\u003eFor a 10-by-12- to 14-foot bedroom, an office, a condo living room, a modest open-concept area, or a properly insulated basement, \u003cstrong\u003e9,000 BTU is generally the right answer\u003c\/strong\u003e. We always validate this with a load calculation that takes into account the floor area, actual insulation, orientation, window area, and number of occupants—never by rule of thumb.\u003c\/p\u003e\n\n\u003ch3\u003eThe technical data to know before installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor model\u003c\/strong\u003e: H09SUH25XGE — \u003cstrong\u003eOutdoor model\u003c\/strong\u003e: H09SUH25XGC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e: 216506200\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: \u003cstrong\u003eR-454B\u003c\/strong\u003e, the new low-global-warming-potential standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply\u003c\/strong\u003e: 220 V — \u003cstrong\u003eMCA 9 A\u003c\/strong\u003e, \u003cstrong\u003eMOP 15 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping\u003c\/strong\u003e: 1\/4 in. liquid, 3\/8 in. gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow\u003c\/strong\u003e: up to 283 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor sound level\u003c\/strong\u003e: 29 to 42 dB(A) — \u003cstrong\u003eoutdoor\u003c\/strong\u003e: 55 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor dimensions\u003c\/strong\u003e: 32.25 x 7.69 x 12.06 in. — \u003cstrong\u003eoutdoor\u003c\/strong\u003e: 31.88 x 12.00 x 21.63 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR cold-climate certification\u003c\/strong\u003e: yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e9 A MCA\u003c\/strong\u003e deserves particular attention. It is one of the lowest electrical requirements in its category, which creates possibilities in older \u003cstrong\u003eMontreal\u003c\/strong\u003e buildings where the electrical panel is already heavily loaded. In a Plateau or Rosemont triplex with a 100 A panel, adding a 15 A circuit for this unit often requires no electrical-panel upgrade—a saving of several hundred dollars that does not appear anywhere in the technical specifications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e29 dB(A)\u003c\/strong\u003e at minimum speed is what makes the unit suitable for a bedroom. It is below the threshold at which most occupants stop noticing the appliance. The wireless control includes \u003cstrong\u003eWi-Fi and voice control as standard\u003c\/strong\u003e, with no optional module to add, and the app controls both the vertical and horizontal swing of the louvers.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you need to know about rebate eligibility\u003c\/h3\u003e\n\u003cp\u003eWe prefer to be direct about this because it is a frequent source of disappointment. \u003cstrong\u003eThe 9,000 BTU version of the Ultimate 25 is not currently listed among the appliances eligible for Hydro-Québec’s LogisVert program\u003c\/strong\u003e, while the 12,000, 18,000, and 24,000 BTU versions are listed and qualify for financial assistance.\u003c\/p\u003e\n\u003cp\u003eThe unit is nevertheless listed in the NEEP directory as a cold-climate model. The discrepancy concerns program registration, not the machine’s performance. We are following the matter with the distributor, and the information will be updated as soon as it changes. In the meantime, if financial assistance is a deciding factor in your decision, we will direct you to the eligible \u003cstrong\u003e12,000 BTU\u003c\/strong\u003e model and tell you frankly whether the difference in capacity is justified for your room.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation: what makes the difference between a good and a poor installation\u003c\/h2\u003e\n\u003cp\u003eA wall-mounted heat pump that is well chosen but poorly installed delivers mediocre results. These are the points we do not compromise on:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor unit positioning.\u003c\/strong\u003e If it is installed too high beneath a cathedral ceiling, warm air will not come back down. Above a door, airflow is obstructed. We look for the wall that allows air to move along the length of the room without a direct obstruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor unit clearance.\u003c\/strong\u003e It must be raised above the typical snow height for the area, with enough clearance for air intake and the drainage of defrost condensate. An outdoor unit installed too low against a foundation wall will eventually be surrounded by ice in February.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum evacuation and leak tightness.\u003c\/strong\u003e With \u003cstrong\u003eR-454B\u003c\/strong\u003e, rigorous evacuation and leak detection are non-negotiable. A careless installation in this regard leads to gradually declining efficiency and eventually to failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping route.\u003c\/strong\u003e We favour short, protected routes and discuss the layout with the client before drilling—because a visible line on a front façade cannot be corrected afterward.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eMaintenance: not much, but it must be done regularly\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eindoor filters\u003c\/strong\u003e should be cleaned every four to six weeks during periods of heavy use. A clogged filter reduces airflow, lowers efficiency, and strains the compressor. By far, this is the most common avoidable cause of service calls we receive.\u003c\/p\u003e\n\u003cp\u003eBeyond the filter, a thorough cleaning of the indoor coil and condensate pan every two to three years maintains air quality and prevents odours. The outdoor unit mainly needs to be kept clear: no accumulated snow against the air intake and no leaves in the grille in the fall.\u003c\/p\u003e\n\n\u003ch3\u003eWhy choose AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe install \u003cstrong\u003eHVAC\u003c\/strong\u003e systems in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, in buildings that were rarely designed to accommodate a heat pump. Our value does not lie in the brand we sell, but in what we do before selling it: a serious load calculation, an electrical-capacity check, a discussed piping route, and honest advice when the requested unit is not the right one.\u003c\/p\u003e\n\u003cp\u003eWe also verify eligibility for financial-assistance programs \u003cstrong\u003ebefore\u003c\/strong\u003e the work, not afterward, and prepare the required documents. That is what prevents unpleasant surprises when it is time to submit the application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for a complete quote, a load calculation for your room, and clear technical advice on the 9,000 BTU TCL Ultimate 25.\u003c\/strong\u003e We will tell you whether it is the right capacity for you—and if it is not, we will tell you which one is.\u003c\/p\u003e","brand":"TCL","offers":[{"title":"Default Title","offer_id":56286075846948,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_TCL_ULTIMATE_25_R454B_9000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_614d9410-30d5-4bad-b175-25a29e2732b5.png?v=1789419391","url":"https:\/\/airgreen.ca\/en\/products\/tcl-ultimate-wall-mounted-heat-pump-25-9000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}