{"product_id":"thermopompe-2-zones-arcoaire-d5cmha-55000-btu-r454b","title":"2-Zone Heat Pump ARCOAIRE D5CMHA | 55,000 BTU - R454B","description":"\u003ch2\u003eTwo very large volumes, a single outdoor heat pump\u003c\/h2\u003e\u003cp\u003eA family room under a cathedral ceiling, an open area running the full length of the house, a basement finished end to end: some spaces exceed what a standard-size head can cover. The \u003cstrong\u003e2-Zone Heat Pump ARCOAIRE D5CMHA | 55,000 BTU - R454B\u003c\/strong\u003e is aimed precisely at these volumes. Its \u003cstrong\u003e4.5-ton\u003c\/strong\u003e \u003cstrong\u003eD5CMHAH55FAK\u003c\/strong\u003e condenser serves \u003cstrong\u003e2 zones\u003c\/strong\u003e and accepts up to 5 at most. It is built with the \u003cstrong\u003eD5FSHAH09XAK\u003c\/strong\u003e, \u003cstrong\u003eD5FSHAH12XAK\u003c\/strong\u003e, \u003cstrong\u003eD5FSHAH18XAK\u003c\/strong\u003e, \u003cstrong\u003eD5FSHAH24XAK\u003c\/strong\u003e and \u003cstrong\u003eD5FSHAH30XAK\u003c\/strong\u003e \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e heads.\u003c\/p\u003e\u003cp\u003eIts ratings are \u003cstrong\u003e22.3 SEER2\u003c\/strong\u003e, \u003cstrong\u003e12.0 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.5 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 3556883\u003c\/strong\u003e. The certificate still lists its capacity at \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $5,640\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eA size justified by the load, not by floor area alone\u003c\/h3\u003e\u003cp\u003eA large condenser is not a better condenser. It is justified when the \u003cstrong\u003eon-site assessment\u003c\/strong\u003e shows it: large volumes under high ceilings, large glass areas, an older house whose envelope lets heat escape. In a recent, well-insulated home, two large rooms will often be better served by a smaller condenser that runs longer at low speed. We do the assessment room by room before recommending this size, and we say so clearly when a smaller model is a better fit.\u003c\/p\u003e\u003ch3\u003eThe D5FSHAH30XAK head and large volumes\u003c\/h3\u003e\u003cp\u003eEach head's code indicates its size, and the D5FSHAH30XAK is the largest on the list. It is meant for rooms where the air must travel a long distance or fill a large volume: a family room with a cathedral ceiling, an open area with a mezzanine, a living room extended by a sunroom. We mount it on a wall from which its airflow runs along the room, high enough to cover the volume, avoiding beams and soffits that would cut off the flow. Its adjustable louvers push warm air down toward the floor in winter; a ceiling fan at low speed helps bring back down the heat that collects under a very high ceiling.\u003c\/p\u003e\u003ch3\u003eThe second zone: a large basement or a second open area\u003c\/h3\u003e\u003cp\u003eThe second head often serves a basement finished over the full footprint of the house, or the upper floor of a home whose rooms open widely onto one another. The D5FSHAH24XAK or D5FSHAH18XAK suits it depending on size. In the basement, the head is mounted high on the wall to push warm air toward the floor, and the \u003cstrong\u003edehumidification\u003c\/strong\u003e mode works there in summer without needlessly cooling a room that is already cool. The total of the heads must stay within the combinations the manufacturer allows for this condenser.\u003c\/p\u003e\u003ch3\u003eThe same published capacity at -8 °C and -15 °C\u003c\/h3\u003e\u003cp\u003eThe certificate lists \u003cstrong\u003e47,000 BTU\/h at -8 °C\u003c\/strong\u003e and \u003cstrong\u003e47,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published. Between 17 °F and 5 °F, the published capacity does not move: for large volumes, that is a reassuring figure.\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCOP of 2.60 at the -8 °C point\u003c\/li\u003e\u003cli\u003eCOP of 2.00 at the -15 °C point\u003c\/li\u003e\u003cli\u003eMaximum capacity at -30 °C: 26,400 BTU\/h, COP of 1.39\u003c\/li\u003e\u003cli\u003eHeating certified down to -30 °C\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThese values sit below the nominal 55,000 BTU size, which is normal in deep cold; the on-site assessment accounts for it. Near -30 °C, the published capacity drops, and backup heat remains a prudent choice in a large glazed volume. These figures come from certificate \u003cstrong\u003eAHRI 215357158\u003c\/strong\u003e, published by NEEP.\u003c\/p\u003e\u003ch3\u003eThree free ports\u003c\/h3\u003e\u003cp\u003eThe D5CMHAH55FAK accepts up to five heads. With two zones, three ports remain available for bedrooms, an office or an added room, provided the whole set stays within the allowed combinations. If these additions are planned, we choose the first two heads and the line route accordingly.\u003c\/p\u003e\u003ch3\u003e4.5 tons: panel, circuit and location\u003c\/h3\u003e\u003cp\u003eA 4.5-ton condenser needs space and a properly sized \u003cstrong\u003ededicated circuit\u003c\/strong\u003e. Before the quote, we check the space and capacity of the electrical panel, taking into account the home's other loads. Outside, we choose a location that is clear for airflow, accessible for service, as far as possible from bedroom windows and neighbouring lots, on a solid stand or a bracket designed for its weight, above the snow line.\u003c\/p\u003e\u003ch3\u003eSEER2, EER2, HSPF2 and COP, straight up\u003c\/h3\u003e\u003cp\u003eThe 22.3 \u003cstrong\u003eSEER2\u003c\/strong\u003e measures \u003cstrong\u003ecooling\u003c\/strong\u003e efficiency over a full season; the 12.0 \u003cstrong\u003eEER2\u003c\/strong\u003e measures it on the hottest days, when a large glass area works hardest. The 10.5 \u003cstrong\u003eHSPF2\u003c\/strong\u003e sums up the \u003cstrong\u003eheating\u003c\/strong\u003e season. \u003cstrong\u003eCOP\u003c\/strong\u003e is read at a given temperature: 2.60 at -8 °C means the heat pump delivers as heat more than two and a half times the electricity it consumes, whereas an electric baseboard delivers exactly what it consumes.\u003c\/p\u003e\u003ch3\u003eCooling a large volume\u003c\/h3\u003e\u003cp\u003eIn summer, a large glazed volume builds up heat quickly. The \u003cstrong\u003einverter compressor\u003c\/strong\u003e speeds up to meet the load, then slows down and holds the set point at low speed, removing humidity at the same time. Both heads work in the same mode at any given time, heating or cooling, each at its own temperature. The new-generation \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant has a global warming potential markedly lower than the fluids it replaces; mildly flammable, it is handled according to precise rules.\u003c\/p\u003e\u003ch3\u003eIndicative LogisVert amount: $5,640\u003c\/h3\u003e\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$5,640\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\u003ch2\u003eInstallation and maintenance\u003c\/h2\u003e\u003ch3\u003eThe installation\u003c\/h3\u003e\u003cp\u003eAfter the \u003cstrong\u003ein-home assessment\u003c\/strong\u003e, the condenser is installed at the chosen location, above the snow line and out of the path of snow falling from the roof. Each head gets its refrigerant line set, communication cable and drain, grouped under a finishing cover outside. For a basement head, the lines pass through the rim joist and a condensate pump often replaces the gravity drain. The condenser is connected to its dedicated circuit with a disconnect. Commissioning includes the leak test, the vacuum, a check of both zones and programming the remotes with you.\u003c\/p\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eRinse the filters of both heads every two weeks in season; a large head mounted up high sometimes calls for a step ladder, and we show you how to open it at commissioning. Keep the condenser clear of snow, ice and leaves, without covering it in winter. An annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e visit cleans the coils and blower wheels, checks the drains and the condensate pump, and tightens the electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 2-Zone Heat Pump ARCOAIRE D5CMHA | 55,000 BTU - R454B. We measure your two large volumes, confirm that this size is justified and check your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797665415460,"sku":"D5CMHAH55FAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_D5CMHA_R454B_2_ZONES_55000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-arcoaire-d5cmha-55000-btu-r454b","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}