{"product_id":"thermopompe-2-zones-arcoaire-dlcmhb-24000-btu-r410a","title":"2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A","description":"\u003ch2\u003eThe living room and the bedroom, each at its own temperature, with a single condenser outside\u003c\/h2\u003e\n\u003cp\u003eIn many homes, the living room and the main bedroom never ask for the same thing at the same time. The living room gets the afternoon sun and fills up in the evening; the bedroom wants cool air at night and a little warmth when you wake up. The \u003cstrong\u003e2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A\u003c\/strong\u003e handles that difference with two independent \u003cstrong\u003ewall heads\u003c\/strong\u003e connected to a single \u003cstrong\u003eDLCMHBH24CAK condenser\u003c\/strong\u003e. Each room keeps its own set point, remote and schedule, and the outdoor unit adjusts its speed to the heads that are calling.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e2-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e2 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e3\u003c\/strong\u003e at most. The wall heads intended for it are the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e and the \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e. Its certified ratings are \u003cstrong\u003e22.3 SEER2\u003c\/strong\u003e, \u003cstrong\u003e12.5 EER2\u003c\/strong\u003e and \u003cstrong\u003e9.6 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2545805\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $2,160\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe homes this size is designed for\u003c\/h3\u003e\n\u003cp\u003eWe recommend this configuration when two rooms carry most of the home's comfort: a living room open to the kitchen and the main bedroom, a ground floor and a bedroom floor, or a home office used all day while the rest of the home stays at a low temperature. In a well-insulated \u003cstrong\u003e4 ½\u003c\/strong\u003e or \u003cstrong\u003e5 ½\u003c\/strong\u003e, two well-placed heads cover most of the year. In an older house, with tired windows or poorly insulated walls, the same configuration still makes sense, but we size it with the existing \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e kept as backup for the coldest nights.\u003c\/p\u003e\n\u003cp\u003eThe size is not chosen by eye. Floor area matters, but window orientation, ceiling height, envelope airtightness and the number of occupants weigh just as much. That is why our quote comes after a visit, never before.\u003c\/p\u003e\n\u003ch3\u003eWhy two heads rather than one large one\u003c\/h3\u003e\n\u003cp\u003eA single \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e, even a generous one, heats the room it is installed in well and the rooms behind a door much less. The bedroom, closed at night, stays cold in January and warm in July, while the living room is overheated. With one head per room, air is delivered where you live, and each space is set without compromise: the living room a little warmer in the evening, the bedroom cooler for sleeping.\u003c\/p\u003e\n\u003cp\u003eThe choice of heads follows the same logic. The \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e, the smaller of the two, suits a bedroom or an office. The \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e takes a larger or more exposed room, such as a medium-sized living room. We confirm which head goes where during the visit, after the needs assessment.\u003c\/p\u003e\n\u003ch3\u003eWhat happens inside the inverter condenser\u003c\/h3\u003e\n\u003cp\u003eThe condenser's \u003cstrong\u003einverter compressor\u003c\/strong\u003e does not run on an on-off cycle. It speeds up when both heads call at the same time, then slows down when only one room needs heat or the set point is reached. The condenser meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each head according to its demand, which keeps temperatures steady and avoids the repeated starts that wear out equipment.\u003c\/p\u003e\n\u003cp\u003eTwo operating rules are worth knowing. First, the heads on the same condenser work in the same mode: all heating or all cooling. In practice this almost never gets in the way, since both rooms are living through the same season. Second, when every head calls at full demand, they share the condenser's capacity. That is why we size room by room rather than dividing the capacity into equal shares.\u003c\/p\u003e\n\u003ch3\u003eWinter in Montreal: what the certified figures say\u003c\/h3\u003e\n\u003cp\u003eThe certificate lists \u003cstrong\u003e18,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) and \u003cstrong\u003e17,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 1.83\u003c\/strong\u003e at the -15 °C point. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -8 °C, the condenser still delivers 75% of its 24,000 BTU nominal size, which covers the vast majority of winter days in Greater \u003cstrong\u003eMontreal\u003c\/strong\u003e. A COP of 1.83 means that at -15 °C, each kilowatt-hour consumed returns 1.83 kilowatt-hours of heat, where a baseboard returns one. During deep cold snaps, the two heads share the available capacity; that is when the existing backup takes over in a less well-insulated house.\u003c\/p\u003e\n\u003cp\u003eYou should also expect \u003cstrong\u003edefrost cycles\u003c\/strong\u003e. In cold, humid weather, the outdoor coil frosts over and the condenser clears it for a few minutes. The heads then stop blowing warm air and a cloud of white vapour may rise from the outdoor unit. This is normal.\u003c\/p\u003e\n\u003ch3\u003eSummer cooling and dehumidification\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the system is designed around a nominal size of \u003cstrong\u003e24,000 BTU\/h\u003c\/strong\u003e shared between the two rooms. The variable-speed compressor runs for long periods at low speed rather than cooling hard and shutting off; the air therefore passes more slowly over the cold coil, which removes more moisture. You notice it most in a bedroom: less clammy air and more comfortable sleep, without the dry chill of an oversized window air conditioner.\u003c\/p\u003e\n\u003cp\u003eEach head also offers a dehumidification mode for muggy days when the outdoor temperature does not justify full cooling.\u003c\/p\u003e\n\u003ch3\u003eSEER2, EER2, HSPF2: what these ratings mean for you\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e22.3 SEER2\u003c\/strong\u003e: seasonal cooling efficiency, measured over a typical summer. The higher the number, the less summer costs in electricity.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12.5 EER2\u003c\/strong\u003e: cooling efficiency in hot weather, at full load. It matters during heat waves.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e9.6 HSPF2\u003c\/strong\u003e: seasonal heating efficiency. This is the rating that weighs most on a Quebec household's bill.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e: the ratio between heat delivered and electricity consumed at a given temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 207642990\u003c\/strong\u003e, as published by ENERGY STAR.\u003c\/p\u003e\n\u003ch3\u003eIndicative LogisVert amount: $2,160\u003c\/h3\u003e\n\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$2,160\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing, check that the installed combination matches the one on the list, then prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eFrom the visit to commissioning\u003c\/h2\u003e\n\u003ch3\u003eOur installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eVisit and needs assessment\u003c\/strong\u003e: we measure each room, note the windows and insulation, then confirm which head goes where.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCondenser location\u003c\/strong\u003e: above the snow line, on a wall bracket or a stand, sheltered from snow sliding off the roof and away from bedroom windows.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant lines\u003c\/strong\u003e: each head gets its own line set back to the condenser, insulated and protected by a line cover outdoors.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e: each head has its own condensate drain, sloped so the water flows out without backing up.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e: a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e for the condenser, checked at the panel during the visit.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e: vacuum, leak test, check of each zone's operation, then setup of the remotes with you.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eA third connection available for later\u003c\/h3\u003e\n\u003cp\u003eThe DLCMHBH24CAK condenser accepts up to 3 zones. If a basement gets finished or an office is added in a few years, a third head can sometimes be connected to it. Before any addition, we check that the condenser's capacity is enough for all three rooms and that the combination follows the manufacturer's rules. If it does not, we tell you plainly and propose another solution.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the head filters every two weeks in season; they come out by hand, without tools. Keep the outdoor unit clear of snow, ice and leaves, and do not cover it in winter: it heats in January too. Plan one \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year to clean the coils, drain and fans and to check the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\n\u003cp\u003eThe serial numbers of the condenser and the heads appear on your invoice, which simplifies any warranty claim.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 2-Zone Heat Pump ARCOAIRE DLCMHB | 24,000 BTU - R410A. We assess both rooms and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable while supplies last.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797683110180,"sku":"DLCMHBH24CAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_DLCMHB_R410A_2_ZONES_2_TONNES_24000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-arcoaire-dlcmhb-24000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}