{"product_id":"thermopompe-2-zones-arcoaire-dlcmhb-48000-btu-r410a","title":"2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A","description":"\u003ch2\u003eTwo very large living areas, a single 4-ton condenser to heat them\u003c\/h2\u003e\n\u003cp\u003eSome houses come down to two large volumes: a ground floor open from end to end and a finished basement almost as big. For these spaces, a small wall head is not enough, and several separate units clutter the walls. The \u003cstrong\u003e2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A\u003c\/strong\u003e answers with two large \u003cstrong\u003ewall heads\u003c\/strong\u003e connected to a single \u003cstrong\u003eDLCMHBH48EAK condenser\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e4-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e2 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e5\u003c\/strong\u003e at most. The wall heads intended for it are the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e, the \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e and the \u003cstrong\u003eDLFSHCH24XAK\u003c\/strong\u003e. Its certified ratings are \u003cstrong\u003e21.2 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.0 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2410134\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $4,680\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhen two zones are enough for a large house\u003c\/h3\u003e\n\u003cp\u003eThis size targets homes where life is concentrated in two large open rooms: a single-storey house whose living room, kitchen and dining room form one space, and a basement used as a family room, playroom or workshop. It also suits a large extended house, whose new wing and original part are heated separately.\u003c\/p\u003e\n\u003cp\u003eIt also has its limits, and we prefer to say so right away. A wall head heats the room it is in; it does not push air behind closed doors. If your house has several closed bedrooms, a configuration with three, four or five zones on the same condenser will serve them better. The on-site assessment and the site visit settle the question.\u003c\/p\u003e\n\u003ch3\u003eThe DLFSHCH24XAK, the head for large volumes\u003c\/h3\u003e\n\u003cp\u003eFor a large open space, the \u003cstrong\u003eDLFSHCH24XAK\u003c\/strong\u003e, the largest of the intended heads, is the usual choice. It is mounted high on the longest wall, so it blows across the full depth of the room. Under a cathedral ceiling, we account for the heat that rises and the air that has to come back down to the occupied zone. The second zone gets the head that matches its actual load: another DLFSHCH24XAK if it is just as large, the \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e or the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e if it is more modest.\u003c\/p\u003e\n\u003cp\u003eThe two heads share the condenser's capacity. When both call at full demand, it is split between them; when only one zone is occupied, it gets all the available capacity.\u003c\/p\u003e\n\u003ch3\u003eElectrical capacity, to be checked first\u003c\/h3\u003e\n\u003cp\u003eA 4-ton condenser requires a larger \u003cstrong\u003ededicated circuit\u003c\/strong\u003e than a small wall-mounted heat pump. Before proposing this system, we open the electrical panel during the visit: available space, capacity of the electrical service, loads already connected such as a range, a dryer or a water heater. In a house whose panel is already heavily loaded, an upgrade may be needed; we point it out during the visit, along with the rest of our findings. The electrical work is part of the written quote, just like the condenser and the heads.\u003c\/p\u003e\n\u003ch3\u003eWinter according to the certificate\u003c\/h3\u003e\n\u003cp\u003eThe certificate lists \u003cstrong\u003e39,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F), with a \u003cstrong\u003eCOP of 2.50\u003c\/strong\u003e, and \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 2.00\u003c\/strong\u003e. The maximum published capacity is \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e, at the same COP. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, the condenser therefore delivers 94% of its 48,000 BTU nominal size. A COP of 2.00 means that at that temperature, each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e confirms that the combination meets the low-temperature performance criteria.\u003c\/p\u003e\n\u003cp\u003eThe certificate does not publish a colder point. We therefore recommend keeping the \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e or other existing heating as backup, set slightly below the heads' set point. They stay off for most of the winter and only serve during extreme cold and \u003cstrong\u003edefrost cycles\u003c\/strong\u003e, those few minutes when the condenser melts the frost off its coil and lets out a cloud of vapour.\u003c\/p\u003e\n\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 207642999\u003c\/strong\u003e, published by NEEP.\u003c\/p\u003e\n\u003ch3\u003eInverter and cooling for large volumes\u003c\/h3\u003e\n\u003cp\u003eThe condenser's \u003cstrong\u003einverter compressor\u003c\/strong\u003e varies its speed according to demand and meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each head. In a large room, it runs for long periods at moderate speed, which keeps the air moving continuously and prevents heat from getting trapped under the ceiling. The two heads always work in the same mode, heating or cooling.\u003c\/p\u003e\n\u003cp\u003eIn cooling, the system is built around a nominal size of \u003cstrong\u003e48,000 BTU\/h\u003c\/strong\u003e for the two zones. The large windows of an open area and the kitchen make it the most heavily loaded zone in summer; in the basement, humidity dominates. Extended low-speed operation and each head's dehumidification mode remove that moisture without needlessly cooling the room.\u003c\/p\u003e\n\u003ch3\u003eThe 21.2 SEER2, 11.0 EER2 and 10.0 HSPF2 ratings\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e measures heating efficiency over the whole cold season. At 10.0, it is the rating to remember for a house heated largely by heat pump, since heating accounts for most of the bill in Quebec. The \u003cstrong\u003eSEER2\u003c\/strong\u003e of 21.2 measures cooling efficiency over a whole summer, and the \u003cstrong\u003eEER2\u003c\/strong\u003e of 11.0 measures cooling at full load, in hot weather. Finally, the \u003cstrong\u003eCOP\u003c\/strong\u003e expresses efficiency at a specific temperature: 2.50 at -8 °C and 2.00 at -15 °C for this system.\u003c\/p\u003e\n\u003ch3\u003eIndicative LogisVert amount: $4,680\u003c\/h3\u003e\n\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$4,680\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eInstallation and maintenance\u003c\/h2\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eThe visit starts with the two spaces: dimensions, windows, insulation, ceiling height. The on-site assessment then confirms the size and the choice of heads. A condenser of this size usually sits on a stand or a sturdy bracket, above the snow line and away from snow sliding off the roof. Each head gets its own \u003cstrong\u003erefrigerant line set\u003c\/strong\u003e, protected by a line cover outdoors, and its own sloped condensate \u003cstrong\u003edrain\u003c\/strong\u003e. In the basement, a condensate pump becomes necessary when gravity is not enough.\u003c\/p\u003e\n\u003cp\u003eCommissioning includes the vacuum, the leak test, a check of each zone and setup of the remotes with you. With 2 zones out of a maximum of 5, the condenser keeps free connections for rooms added later, after checking the remaining capacity.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of both heads every two weeks in season. Keep the condenser clear of snow, ice and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 2-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A. We assess your two large spaces and your electrical panel and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable while supplies last.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797736882468,"sku":"DLCMHBH48EAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_DLCMHB_R410A_2_ZONES_4_TONNES_48000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-arcoaire-dlcmhb-48000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}