{"product_id":"thermopompe-2-zones-conforto-mhmz-36000-btu-r410a","title":"2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A","description":"\u003ch2\u003eThe ground floor and the attic floor, each with its own head, even during heat waves\u003c\/h2\u003e\n\u003cp\u003eA floor finished under the roof is often the most pleasant room in the house in spring and the most uncomfortable in July. The sun heats the roof all day, and heat builds up under the sloped ceilings long after sunset. The \u003cstrong\u003e2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A\u003c\/strong\u003e gives that floor its own \u003cstrong\u003ewall head\u003c\/strong\u003e, another on the ground floor, and connects them to a single \u003cstrong\u003eMHMZ436DACFC condenser\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e3-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e2 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e4\u003c\/strong\u003e at most. Its AHRI certificate was established with the \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e, \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e and \u003cstrong\u003eMHWAL18DACFC\u003c\/strong\u003e wall heads; your heads are chosen with you during the visit. Its certified ratings are \u003cstrong\u003e22.2 SEER2\u003c\/strong\u003e, \u003cstrong\u003e13.6 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.3 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2495072\u003c\/strong\u003e, and its indicative LogisVert amount is $3,960 (only Hydro-Québec confirms the amount granted).\u003c\/p\u003e\n\u003ch3\u003eA floor under the roof, the hardest to cool\u003c\/h3\u003e\n\u003cp\u003eAn attic converted into a main bedroom, a mezzanine turned into an office, the upper floor of a Cape Cod-style house: these spaces share low walls, sloped ceilings and a roof directly overhead. In summer, they take the roof's heat before every other room. In winter, they lose their own through the same roof if the insulation is thin.\u003c\/p\u003e\n\u003cp\u003eA head on the ground floor cannot cool an upper floor: cold air sinks, it does not rise. That is why this system places a head on each level. The ground-floor one serves the living space; the upper one, the bedrooms or the office under the roof. The on-site assessment takes the roof insulation into account, and we tell you plainly if it limits the result.\u003c\/p\u003e\n\u003cp\u003eHumidity adds to the heat. Under the roof, warm, damp air makes sleep difficult even when the thermometer seems reasonable. By running for long periods at low speed, the upstairs head removes that moisture; the dehumidification mode listed in the brochure helps on muggy days when full cooling is not needed.\u003c\/p\u003e\n\u003ch3\u003eWhat 13.6 EER2, 22.2 SEER2 and 10.3 HSPF2 measure\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e measures cooling efficiency at full load, in hot weather. That is exactly the situation of a floor under the roof in July, when the head runs flat out during the hottest hours. At 13.6, this rating is the system's strong point for heat waves.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2\u003c\/strong\u003e of 22.2 measures cooling efficiency over a whole summer, mild days included. The \u003cstrong\u003eHSPF2\u003c\/strong\u003e of 10.3 does the same for heating over the whole cold season; it is calculated for a reference climate (region IV) and is useful to compare models. Finally, the \u003cstrong\u003eCOP\u003c\/strong\u003e expresses efficiency at a specific temperature: it is the ratio between heat delivered and electricity consumed.\u003c\/p\u003e\n\u003ch3\u003eTwo zones, two heads to choose\u003c\/h3\u003e\n\u003cp\u003eThe largest head usually goes in the ground-floor living space. Upstairs, the choice depends on floor area and exposure: the \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e for a main bedroom under the roof, the MHWAL18DACFC if the floor is open and very exposed, the \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e for a small office. The on-site assessment decides.\u003c\/p\u003e\n\u003cp\u003eThe two heads share the condenser's capacity. On a summer afternoon, the upper floor asks for the largest share; on a winter evening, it is often the ground floor. With 2 zones out of a maximum of 4, two connections remain free for rooms added later, after checking the remaining capacity.\u003c\/p\u003e\n\u003ch3\u003ePlacing a head under a sloped ceiling\u003c\/h3\u003e\n\u003cp\u003eUnder the roof, there is often little space at the top of the walls. We install the head on the gable wall or the tallest wall, so it blows along the length of the floor rather than against a slope. It needs enough space above it for the air intake. When the floor is divided into two bedrooms, the head goes in the larger or more exposed one, and we tell you whether the second bedroom will be well served with the door open or deserves its own zone.\u003c\/p\u003e\n\u003ch3\u003eWinter: the full nominal size at -15 °C\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives \u003cstrong\u003e33,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F), with a \u003cstrong\u003eCOP of 2.40\u003c\/strong\u003e, and \u003cstrong\u003e36,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 1.90\u003c\/strong\u003e. The maximum published capacity is \u003cstrong\u003e36,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, the NEEP list therefore gives 36,000 BTU\/h for this system. A COP of 1.90 means that at that temperature, each kilowatt-hour consumed returns 1.90 kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e confirms that the combination meets the low-temperature performance criteria.\u003c\/p\u003e\n\u003cp\u003eThese figures come from NEEP's cold-climate heat pump list, for certificate \u003cstrong\u003eAHRI 210605816\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eBackup heat and defrost\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives no point colder than -15 °C. We therefore recommend keeping the existing \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e, set slightly below the heads' set point. They stay off for most of the winter and only take over during extreme cold. In cold, humid weather, the condenser also runs \u003cstrong\u003edefrost cycles\u003c\/strong\u003e of a few minutes: the heads stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.\u003c\/p\u003e\n\u003ch3\u003eThe inverter compressor and R-410A refrigerant\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003einverter compressor\u003c\/strong\u003e varies its speed according to the demand of the two heads and meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each one. It runs for long periods at moderate speed, which removes moisture from the air in cooling and keeps temperatures steady in heating. For cooling, the system is built around a nominal size of \u003cstrong\u003e36,000 BTU\/h\u003c\/strong\u003e. The two heads always work in the same mode, heating or cooling, as on any multi-zone system of this type.\u003c\/p\u003e\n\u003ch3\u003eThe indicative LogisVert amount: $3,960\u003c\/h3\u003e\n\u003cp\u003eThe system is listed in Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program, with an indicative amount of \u003cstrong\u003e$3,960\u003c\/strong\u003e for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eInstallation on two levels\u003c\/h2\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eThe refrigerant line for the ground-floor head is short. The one for the upper floor runs up the facade in a painted line cover; we show you the route before drilling. Each head gets its own \u003cstrong\u003erefrigerant line set\u003c\/strong\u003e and its own condensate \u003cstrong\u003edrain\u003c\/strong\u003e, sloped toward the outside.\u003c\/p\u003e\n\u003cp\u003eThe condenser is installed above the snow line, on a wall bracket or a stand, away from snow sliding off the roof. It is connected to a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, checked at the panel during the visit. Commissioning includes the vacuum, the leak test, a check of both zones and setup of the remotes with you.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of both heads every two weeks in season; the upstairs one works hard in summer and deserves particular attention. Keep the condenser clear of snow and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, the company behind the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 36,000 BTU - R410A. We assess both levels and confirm the right size and check your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Conforto","offers":[{"title":"Default Title","offer_id":67797761229092,"sku":"MHMZ436DACFC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_CONFORTO_MAXIMUM_MHMZ_R410A_2_ZONES_3_TONNES_36000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-conforto-mhmz-36000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}