{"product_id":"thermopompe-2-zones-conforto-mhmz-48000-btu-r410a","title":"2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A","description":"\u003ch2\u003eAn intergenerational home, two households, two settings and a single condenser\u003c\/h2\u003e\n\u003cp\u003eWhen parents move into a suite finished in the basement or in an addition, the house shelters two households with neither the same schedules nor the same idea of a comfortable temperature. The \u003cstrong\u003e2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A\u003c\/strong\u003e gives each one its own \u003cstrong\u003ewall head\u003c\/strong\u003e and its own remote, fed by a single \u003cstrong\u003eMHMZ548DACFC condenser\u003c\/strong\u003e installed outside.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e4-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e2 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e5\u003c\/strong\u003e at most. Its AHRI certificate was established with the \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e, \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e and \u003cstrong\u003eMHWAL24DACFC\u003c\/strong\u003e wall heads; your heads are chosen with you during the visit. Its certified ratings are \u003cstrong\u003e21.8 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.7 EER2\u003c\/strong\u003e and \u003cstrong\u003e9.8 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2495078\u003c\/strong\u003e, and its indicative LogisVert amount is $4,320 (only Hydro-Québec confirms the amount granted).\u003c\/p\u003e\n\u003ch3\u003eTwo households under one roof\u003c\/h3\u003e\n\u003cp\u003eIn an intergenerational home, needs differ from one floor to the next. Grandparents often prefer a warmer house and spend their days at home; the family on the ground floor leaves in the morning and comes back in the evening. A single set point for the whole house is bound to leave someone unhappy. With two zones, each household sets its own unit as it sees fit, without negotiating over a thermostat.\u003c\/p\u003e\n\u003cp\u003eThis size also suits any house that divides into two large, well-separated spaces: an open ground floor and a finished basement, a house and its addition, or a large single-storey house whose bedroom wing is closed off. The assessment of each space confirms that the size is right.\u003c\/p\u003e\n\u003ch3\u003eTwo large heads\u003c\/h3\u003e\n\u003cp\u003eFor the main living space, often open to the kitchen, we usually plan the largest head. The second unit gets the head that matches its load: another MHWAL24DACFC if it is just as large, the \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e if it is a more compact studio. The \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e is better suited to small closed rooms.\u003c\/p\u003e\n\u003cp\u003eThe two heads share the condenser's capacity. When both units call at full demand, it is split between them; when only one is occupied, it gets all the available capacity. With 2 zones out of a maximum of 5, three connections remain free to equip closed bedrooms later, after checking the remaining capacity.\u003c\/p\u003e\n\u003ch3\u003eA single mode for both units\u003c\/h3\u003e\n\u003cp\u003eThere is one thing to know before choosing this system: the heads on the same condenser always work in the same mode, all heating or all cooling. Each household sets its own temperature, but not the mode. In practice, both units live through the same season and the question rarely comes up; it can, however, arise on a few spring or fall days. We discuss it during the visit to agree with you on how to handle those days.\u003c\/p\u003e\n\u003cp\u003eThe solution is usually simple. On a mild day when one unit needs a little heat and the other does not, the second unit's head can be turned off or switched to fan mode while the first keeps heating. Each unit keeps its own remote, which prevents one household from unintentionally changing the other's setting.\u003c\/p\u003e\n\u003ch3\u003eWhat the NEEP list shows for winter\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives \u003cstrong\u003e36,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F), with a \u003cstrong\u003eCOP of 2.30\u003c\/strong\u003e, and \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 2.00\u003c\/strong\u003e. The maximum published capacity is \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, a COP of 2.00 means that each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e confirms that the combination meets the low-temperature performance criteria.\u003c\/p\u003e\n\u003cp\u003eThese figures come from NEEP's cold-climate heat pump list, for certificate \u003cstrong\u003eAHRI 210605819\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eBackup heat during deep cold\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives no point colder than -15 °C. In a unit occupied by older people, we are particularly keen on keeping the backup in place: the existing \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e, set slightly below the heads' set point, stay off most of the time and take over during extreme cold. They also fill in the \u003cstrong\u003edefrost cycles\u003c\/strong\u003e, those few minutes when the condenser melts the frost off its coil and the heads stop blowing warm air. A cloud of vapour above the outdoor unit is normal at those times.\u003c\/p\u003e\n\u003ch3\u003eThe inverter compressor between two units\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003einverter compressor\u003c\/strong\u003e varies its speed according to the demand of the two heads and meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each one. During the day, it runs slowly for the only occupied unit; in the evening, it speeds up when both households are home. This continuous operation keeps temperatures steady and avoids the repeated starts that wear out equipment.\u003c\/p\u003e\n\u003ch3\u003eSummer in both units\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the system is built around a nominal size of \u003cstrong\u003e48,000 BTU\/h\u003c\/strong\u003e for the two zones. On the ground floor, the windows and the kitchen load the room; in the basement, it is mostly humidity. Extended low-speed operation removes that moisture, and the dehumidification mode listed in the brochure helps on muggy days.\u003c\/p\u003e\n\u003ch3\u003eThe 21.8 SEER2, 11.7 EER2 and 9.8 HSPF2 ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e: cooling efficiency over a whole summer.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e: cooling at full load, in hot weather.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e: heating efficiency over the whole cold season, calculated for a reference climate (region IV); it is used to compare models.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.30 at -8 °C and 2.00 at -15 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe indicative LogisVert amount: $4,320\u003c\/h3\u003e\n\u003cp\u003eThe system is listed in Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program, with an indicative amount of \u003cstrong\u003e$4,320\u003c\/strong\u003e for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eInstallation and maintenance\u003c\/h2\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eAfter the visit and the on-site assessment, the condenser is installed above the snow line, on a stand or a sturdy bracket, away from snow sliding off the roof and from bedroom windows. A 4-ton condenser requires a larger \u003cstrong\u003ededicated circuit\u003c\/strong\u003e than a small wall-mounted heat pump: we check the panel's space and capacity during the visit.\u003c\/p\u003e\n\u003cp\u003eEach head gets its own \u003cstrong\u003erefrigerant line set\u003c\/strong\u003e back to the condenser, protected by a line cover outdoors. For a basement unit, the line goes through the foundation wall and the condensate \u003cstrong\u003edrain\u003c\/strong\u003e often needs a small pump, for lack of a natural slope; we determine that during the visit. Commissioning includes the vacuum, the leak test, a check of both zones and setup of the remotes with each household.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of both heads every two weeks in season; in an intergenerational home, agree on who takes care of each head. Keep the condenser clear of snow and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, the company behind the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 2-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A. We assess both units and confirm the right size and check your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Conforto","offers":[{"title":"Default Title","offer_id":67797773713700,"sku":"MHMZ548DACFC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_CONFORTO_MAXIMUM_MHMZ_R410A_2_ZONES_4_TONNES_48000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-conforto-mhmz-48000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}