{"product_id":"thermopompe-2-zones-direct-air-heat-xtreme-pro-35-c-ext-36000-btu","title":"2-Zone HEAT XTREME PRO Heat Pump (-35°C) | Outdoor: 36000 BTU","description":"\u003ch2 data-section-id=\"1uvcy5e\" data-start=\"93\" data-end=\"166\"\u003eA Multi-Zone HVAC Solution Designed for Quebec's Harsh Winters\u003c\/h2\u003e\n\u003cp data-start=\"168\" data-end=\"674\"\u003eAt AirGreen, we regularly install \u003cstrong data-start=\"226\" data-240=\"240\"\u003emulti-zone\u003c\/strong\u003e systems in residential properties and small apartment buildings in \u003cstrong data-start=\"314\" data-end=\"377\"\u003eMontreal, Laval, Longueuil, on the North Shore, and the South Shore\u003c\/strong\u003e. The \u003cstrong data-start=\"382\" data-end=\"440\"\u003e2-zone DIRECT AIR HEAT XTREME PRO (-35°C) heat pump\u003c\/strong\u003e with a \u003cstrong data-start=\"466\" data-end=\"480\"\u003e36,000 BTU\u003c\/strong\u003e outdoor unit is one of the models we recommend when our clients are looking for an optimal balance between \u003cstrong data-start=\"586\" data-end=\"673\"\u003eextreme winter performance, installation flexibility, and energy efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"676\" data-end=\"895\"\u003eThis system is specifically designed to operate in harsh climatic conditions, with heating capacity maintained down to \u003cstrong data-start=\"822\" data-end=\"831\"\u003e-35°C\u003c\/strong\u003e, an essential feature in our Quebec reality.\u003c\/p\u003e\n\u003chr data-start=\"897\" data-end=\"900\"\u003e\n\u003ch2 data-section-id=\"jrx50j\" data-start=\"902\" data-end=\"976\"\u003eReal Heating and Cooling Performance: Beyond the Numbers\u003c\/h2\u003e\n\u003ch3 data-section-id=\"65a3ng\" data-start=\"978\" data-end=\"1040\"\u003eCapacity tailored to the real needs of Quebec homes\u003c\/h3\u003e\n\u003cp data-start=\"1042\" data-end=\"1123\"\u003eWith a nominal capacity of \u003cstrong data-start=\"1072\" data-end=\"1086\"\u003e36,000 BTU\u003c\/strong\u003e, this heat pump is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"1125\" data-end=\"1268\"\u003e\n\u003cli data-section-id=\"1hjsw1s\" data-start=\"1125\" data-end=\"1168\"\u003eMedium-sized single-family homes\u003c\/li\u003e\n\u003cli data-section-id=\"mr1cnw\" data-start=\"1169\" data-end=\"1212\"\u003eDuplexes or triplexes with distinct zones\u003c\/li\u003e\n\u003cli data-section-id=\"13up9ed\" data-start=\"1213\" data-end=\"1268\"\u003eCondos with differentiated needs (living room + bedrooms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1270\" data-end=\"1393\"\u003eIn practice, we recently installed this model in a duplex in \u003cstrong data-start=\"1340\" data-end=\"1356\"\u003eBoucherville\u003c\/strong\u003e, where the owners wanted to:\u003c\/p\u003e\n\u003cul data-start=\"1395\" data-end=\"1562\"\u003e\n\u003cli data-section-id=\"rfj85i\" data-start=\"1395\" data-end=\"1445\"\u003eEfficiently heat two independent floors\u003c\/li\u003e\n\u003cli data-section-id=\"kudpca\" data-start=\"1446\" data-end=\"1498\"\u003eReduce their reliance on electric baseboard heaters\u003c\/li\u003e\n\u003cli data-section-id=\"pu2buc\" data-start=\"1499\" data-end=\"1562\"\u003eMaintain constant comfort even during cold spells\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1564\" data-end=\"1690\"\u003eResult: a significant reduction in energy consumption and stable temperature even during a period of \u003cstrong data-start=\"1680\" data-end=\"1689\"\u003e-27°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jzp8l8\" data-start=\"1692\" data-end=\"1724\"\u003eAdvanced energy efficiency\u003c\/h3\u003e\n\u003cp data-start=\"1726\" data-end=\"1768\"\u003eThis model offers high performance:\u003c\/p\u003e\n\u003cul data-start=\"1770\" data-end=\"1883\"\u003e\n\u003cli data-section-id=\"uwl3xc\" data-start=\"1770\" data-end=\"1811\"\u003e\u003cstrong data-start=\"1772\" data-end=\"1809\"\u003eSEER2: 22+ (depending on configuration)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"w6mh48\" data-start=\"1812\" data-end=\"1831\"\u003e\u003cstrong data-start=\"1814\" data-end=\"1829\"\u003eHigh HSPF2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1uzmrtj\" data-start=\"1832\" data-end=\"1883\"\u003e\u003cstrong data-start=\"1834\" data-end=\"1881\"\u003eCOP of 1.93 at -8°C (according to provided data)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1885\" data-end=\"1933\"\u003eThese indicators translate concretely into:\u003c\/p\u003e\n\u003cul data-start=\"1935\" data-end=\"2076\"\u003e\n\u003cli data-section-id=\"13rflm\" data-start=\"1935\" data-end=\"1974\"\u003eSignificant energy savings\u003c\/li\u003e\n\u003cli data-section-id=\"35r18a\" data-start=\"1975\" data-end=\"2024\"\u003eImproved efficiency in continuous heating\u003c\/li\u003e\n\u003cli data-section-id=\"1k9cxp5\" data-start=\"2025\" data-end=\"2076\"\u003eEligibility for subsidy programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2078\" data-end=\"2081\"\u003e\n\u003ch2 data-section-id=\"119i9y3\" data-start=\"2083\" data-end=\"2146\"\u003eHeat Xtreme PRO Technology: Designed for the Canadian Climate\u003c\/h2\u003e\n\u003ch3 data-section-id=\"n05xgu\" data-start=\"2148\" data-end=\"2180\"\u003eOperation down to -35°C\u003c\/h3\u003e\n\u003cp data-start=\"2182\" data-end=\"2329\"\u003eUnlike many standard systems, this heat pump continues to provide efficient heating at very low temperatures. This means:\u003c\/p\u003e\n\u003cul data-start=\"2331\" data-end=\"2444\"\u003e\n\u003cli data-section-id=\"gi3tya\" data-start=\"2331\" data-end=\"2374\"\u003eLess reliance on backup systems\u003c\/li\u003e\n\u003cli data-section-id=\"c99t11\" data-start=\"2375\" data-end=\"2405\"\u003eConstant thermal comfort\u003c\/li\u003e\n\u003cli data-section-id=\"19hc64w\" data-start=\"2406\" data-end=\"2444\"\u003eBetter long-term profitability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2446\" data-end=\"2506\"\u003eAccording to the brochure, the system operates within a range of:\u003c\/p\u003e\n\u003cul data-start=\"2508\" data-end=\"2577\"\u003e\n\u003cli data-section-id=\"gyq2u8\" data-start=\"2508\" data-end=\"2544\"\u003e\u003cstrong data-start=\"2510\" data-end=\"2542\"\u003eAir conditioning: -30°C to 50°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1qfmh2\" data-start=\"2545\" data-end=\"2577\"\u003e\u003cstrong data-start=\"2547\" data-end=\"2575\"\u003eHeating: -35°C to 30°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ojhm42\" data-start=\"2579\" data-end=\"2620\"\u003eIntelligent defrosting and restart\u003c\/h3\u003e\n\u003cp data-start=\"2622\" data-end=\"2697\"\u003eIn our installations in \u003cstrong data-start=\"2647\" data-end=\"2656\"\u003eLaval\u003c\/strong\u003e and \u003cstrong data-start=\"2660\" data-end=\"2674\"\u003eRepentigny\u003c\/strong\u003e, we observe that:\u003c\/p\u003e\n\u003cul data-start=\"2699\" data-end=\"2837\"\u003e\n\u003cli data-section-id=\"1je6uq3\" data-start=\"2699\" data-end=\"2760\"\u003eAutomatic defrosting reduces performance losses\u003c\/li\u003e\n\u003cli data-section-id=\"134z6jq\" data-start=\"2761\" data-end=\"2837\"\u003eAutomatic restart protects the system during power outages\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2839\" data-end=\"2902\"\u003eThese technical details make a significant difference in winter.\u003c\/p\u003e\n\u003chr data-start=\"2904\" data-end=\"2907\"\u003e\n\u003ch2 data-section-id=\"1l2wrgt\" data-start=\"2909\" data-end=\"2958\"\u003eMulti-zone Configuration: Maximum Flexibility\u003c\/h2\u003e\n\u003ch3 data-section-id=\"zgpksh\" data-start=\"2960\" data-end=\"2985\"\u003e2 independent zones\u003c\/h3\u003e\n\u003cp data-start=\"2987\" data-end=\"3069\"\u003eThis system allows connecting two indoor units, with individual control:\u003c\/p\u003e\n\u003cul data-start=\"3071\" data-end=\"3182\"\u003e\n\u003cli data-section-id=\"1kl8r2v\" data-start=\"3071\" data-end=\"3109\"\u003eIndependent temperature per room\u003c\/li\u003e\n\u003cli data-section-id=\"7izne5\" data-start=\"3110\" data-end=\"3157\"\u003eOptimization of energy consumption\u003c\/li\u003e\n\u003cli data-section-id=\"7xlxog\" data-start=\"3158\" data-end=\"3182\"\u003ePersonalized comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"fnhg2r\" data-start=\"3184\" data-end=\"3227\"\u003ePossibility of expansion up to 4 zones\u003c\/h3\u003e\n\u003cp data-start=\"3229\" data-end=\"3299\"\u003eThe \u003cstrong data-start=\"3248\" data-end=\"3269\"\u003eDIRM-36HXPRO28-4Z\u003c\/strong\u003e outdoor unit allows for future expansion:\u003c\/p\u003e\n\u003cul data-start=\"3301\" data-end=\"3365\"\u003e\n\u003cli data-section-id=\"1krlfwo\" data-start=\"3301\" data-end=\"3332\"\u003eUp to \u003cstrong data-start=\"3311\" data-end=\"3330\"\u003e4 zones maximum\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w5qu65\" data-start=\"3333\" data-end=\"3365\"\u003eIdeal for scalable projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3367\" data-end=\"3586\"\u003eIn a project in \u003cstrong data-start=\"3384\" data-end=\"3407\"\u003eMontreal (Rosemont)\u003c\/strong\u003e, we initially installed this system with 2 zones, with preparation for a 3rd zone in the future. This strategy reduces short-term costs while maintaining flexibility.\u003c\/p\u003e\n\u003chr data-start=\"3588\" data-end=\"3591\"\u003e\n\u003ch2 data-section-id=\"1g7yesb\" data-start=\"3593\" data-end=\"3640\"\u003eAir Quality and Advanced Indoor Comfort\u003c\/h2\u003e\n\u003ch3 data-section-id=\"fw8s5j\" data-start=\"3642\" data-end=\"3675\"\u003eIntelligent air management\u003c\/h3\u003e\n\u003cp data-start=\"3677\" data-end=\"3717\"\u003eCompatible wall units offer:\u003c\/p\u003e\n\u003cul data-start=\"3719\" data-end=\"3834\"\u003e\n\u003cli data-section-id=\"60quwe\" data-start=\"3719\" data-end=\"3771\"\u003e\u003cstrong data-start=\"3721\" data-end=\"3769\"\u003eVertical and horizontal automatic louvers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1acyoi5\" data-start=\"3772\" data-end=\"3800\"\u003eUniform air distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1t3lybw\" data-start=\"3801\" data-end=\"3834\"\u003eElimination of cold zones\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3836\" data-end=\"3927\"\u003eThe louvers also have a position memory, improving daily comfort.\u003c\/p\u003e\n\u003ch3 data-section-id=\"10wl3w9\" data-start=\"3929\" data-end=\"3961\"\u003eIntegrated advanced functions\u003c\/h3\u003e\n\u003cp data-start=\"3963\" data-end=\"4002\"\u003eAmong the important features:\u003c\/p\u003e\n\u003cul data-start=\"4004\" data-end=\"4176\"\u003e\n\u003cli data-section-id=\"p85pat\" data-start=\"4004\" data-end=\"4028\"\u003eHumidity sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1f0u82e\" data-start=\"4029\" data-end=\"4055\"\u003eMotion sensor\u003c\/li\u003e\n\u003cli data-section-id=\"1i8xua0\" data-start=\"4056\" data-end=\"4083\"\u003eEnergy-saving mode\u003c\/li\u003e\n\u003cli data-section-id=\"30rw5x\" data-start=\"4084\" data-end=\"4098\"\u003eTurbo mode\u003c\/li\u003e\n\u003cli data-section-id=\"7623d6\" data-start=\"4099\" data-end=\"4176\"\u003e\"Follow me\" function (optimization based on remote control position)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4178\" data-end=\"4264\"\u003eThese options are particularly useful in modern open-plan homes.\u003c\/p\u003e\n\u003chr data-start=\"4266\" data-end=\"4269\"\u003e\n\u003ch2 data-section-id=\"h9hv5x\" data-start=\"4271\" data-end=\"4323\"\u003eAirGreen Installation: What Makes the Difference\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1xqpxnw\" data-start=\"4325\" data-end=\"4371\"\u003eAn installation adapted to each building\u003c\/h3\u003e\n\u003cp data-start=\"4373\" data-end=\"4497\"\u003eAt AirGreen, we never perform standardized installations without analysis. For this type of heat pump, we evaluate:\u003c\/p\u003e\n\u003cul data-start=\"4499\" data-end=\"4648\"\u003e\n\u003cli data-section-id=\"1bcvlpg\" data-start=\"4499\" data-end=\"4526\"\u003eRoom distribution\u003c\/li\u003e\n\u003cli data-section-id=\"jyax9j\" data-start=\"4527\" data-end=\"4554\"\u003eActual thermal load\u003c\/li\u003e\n\u003cli data-section-id=\"be5xtw\" data-start=\"4555\" data-end=\"4592\"\u003eOptimal unit positioning\u003c\/li\u003e\n\u003cli data-section-id=\"12tgfjk\" data-start=\"4593\" data-end=\"4648\"\u003ePiping length (important for performance)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"8yy3da\" data-start=\"4650\" data-end=\"4686\"\u003eConcrete example on the North Shore\u003c\/h3\u003e\n\u003cp data-start=\"4688\" data-end=\"4734\"\u003eIn a house in \u003cstrong data-start=\"4706\" data-end=\"4720\"\u003eBlainville\u003c\/strong\u003e, we:\u003c\/p\u003e\n\u003cul data-start=\"4736\" data-end=\"4881\"\u003e\n\u003cli data-section-id=\"1dknn9n\" data-start=\"4736\" data-end=\"4781\"\u003eInstalled a 12,000 BTU unit in the living room\u003c\/li\u003e\n\u003cli data-section-id=\"15a9kwx\" data-start=\"4782\" data-end=\"4828\"\u003eInstalled an 18,000 BTU unit upstairs\u003c\/li\u003e\n\u003cli data-section-id=\"1nlb07y\" data-start=\"4829\" data-end=\"4881\"\u003eOptimized piping to minimize losses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4883\" data-end=\"4895\"\u003eResult:\u003c\/p\u003e\n\u003cul data-start=\"4896\" data-end=\"4991\"\u003e\n\u003cli data-section-id=\"l3ae4x\" data-start=\"4896\" data-end=\"4933\"\u003eBetter heat distribution\u003c\/li\u003e\n\u003cli data-section-id=\"15r3bck\" data-start=\"4934\" data-end=\"4956\"\u003eNoise reduction\u003c\/li\u003e\n\u003cli data-section-id=\"hzz2t1\" data-start=\"4957\" data-end=\"4991\"\u003eMaximum system efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4993\" data-end=\"4996\"\u003e\n\u003ch2 data-section-id=\"azr2k0\" data-start=\"4998\" data-end=\"5041\"\u003eSubsidies and Return on Investment\u003c\/h2\u003e\n\u003ch3 data-section-id=\"9t82tk\" data-start=\"5043\" data-end=\"5067\"\u003eLogisVert subsidy\u003c\/h3\u003e\n\u003cp data-start=\"5069\" data-end=\"5115\"\u003eThis model is eligible for a subsidy of:\u003c\/p\u003e\n\u003cul data-start=\"5117\" data-end=\"5163\"\u003e\n\u003cli data-section-id=\"1kx23h6\" data-start=\"5117\" data-end=\"5163\"\u003e\u003cstrong data-start=\"5119\" data-end=\"5161\"\u003e$3,960 (updated November 26, 2025)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5165\" data-end=\"5217\"\u003eThis significantly reduces the acquisition cost.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13z2lu3\" data-start=\"5219\" data-end=\"5247\"\u003eObserved real savings\u003c\/h3\u003e\n\u003cp data-start=\"5249\" data-end=\"5273\"\u003eFor several clients:\u003c\/p\u003e\n\u003cul data-start=\"5275\" data-end=\"5399\"\u003e\n\u003cli data-section-id=\"1oulusl\" data-start=\"5275\" data-end=\"5326\"\u003e30% to 50% reduction in heating costs\u003c\/li\u003e\n\u003cli data-section-id=\"1sk7zax\" data-start=\"5327\" data-end=\"5363\"\u003ePayback in a few years\u003c\/li\u003e\n\u003cli data-section-id=\"k08vgz\" data-start=\"5364\" data-end=\"5399\"\u003eIncrease in property value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5401\" data-end=\"5404\"\u003e\n\u003ch2 data-section-id=\"i3hd0i\" data-start=\"5406\" data-end=\"5461\"\u003eImportant Technical Characteristics to Consider\u003c\/h2\u003e\n\u003ch3 data-section-id=\"17idm3r\" data-start=\"5463\" data-end=\"5479\"\u003eKey Data\u003c\/h3\u003e\n\u003cul data-start=\"5481\" data-end=\"5671\"\u003e\n\u003cli data-section-id=\"1rjcs9s\" data-start=\"5481\" data-end=\"5510\"\u003e\u003cstrong data-start=\"5483\" data-end=\"5508\"\u003eCapacity: 36,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"um6n5k\" data-start=\"5511\" data-end=\"5539\"\u003e\u003cstrong data-start=\"5513\" data-end=\"5537\"\u003eRefrigerant: R-410A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"73qkpc\" data-start=\"5540\" data-end=\"5562\"\u003e\u003cstrong data-start=\"5542\" data-end=\"5560\"\u003eVoltage: 220V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"q8uc6a\" data-start=\"5563\" data-end=\"5605\"\u003e\u003cstrong data-start=\"5565\" data-end=\"5603\"\u003eOutdoor sound level: 63 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"15jre0q\" data-start=\"5606\" data-end=\"5630\"\u003e\u003cstrong data-start=\"5608\" data-end=\"5628\"\u003eAHRI: 207743791\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1sj0nq6\" data-start=\"5631\" data-end=\"5671\"\u003e\n\u003cstrong data-start=\"5633\" data-end=\"5663\"\u003eENERGY STAR (cold climate)\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"trpo4o\" data-start=\"5673\" data-end=\"5703\"\u003eDimensions and Installation\u003c\/h3\u003e\n\u003cul data-start=\"5705\" data-end=\"5853\"\u003e\n\u003cli data-section-id=\"drcqj0\" data-start=\"5705\" data-end=\"5758\"\u003eExterior dimensions: 37.48 x 16.34 x 52.48 in\u003c\/li\u003e\n\u003cli data-section-id=\"1euvpg3\" data-start=\"5759\" data-end=\"5804\"\u003eWall-mounted or floor stand installation\u003c\/li\u003e\n\u003cli data-section-id=\"xwi37d\" data-start=\"5805\" data-end=\"5853\"\u003eCompatible with multiple indoor models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5855\" data-end=\"5858\"\u003e\n\u003ch2 data-section-id=\"lfwagk\" data-start=\"5860\" data-end=\"5890\"\u003eCommon Mistakes to Avoid\u003c\/h2\u003e\n\u003ch3 data-section-id=\"16g9u1o\" data-start=\"5892\" data-end=\"5942\"\u003e1. Undersizing indoor units\u003c\/h3\u003e\n\u003cp data-start=\"5944\" data-end=\"5978\"\u003eAn incorrect calculation can lead to:\u003c\/p\u003e\n\u003cul data-start=\"5980\" data-end=\"6045\"\u003e\n\u003cli data-section-id=\"lbuswx\" data-start=\"5980\" data-end=\"6004\"\u003ePoor performance\u003c\/li\u003e\n\u003cli data-section-id=\"1ml5a8v\" data-start=\"6005\" data-end=\"6024\"\u003eOverconsumption\u003c\/li\u003e\n\u003cli data-section-id=\"1buna44\" data-start=\"6025\" data-end=\"6045\"\u003ePremature wear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1geef2k\" data-start=\"6047\" data-end=\"6086\"\u003e2. Incorrect multi-zone configuration\u003c\/h3\u003e\n\u003cp data-start=\"6088\" data-end=\"6124\"\u003eThe brochure clearly states that:\u003c\/p\u003e\n\u003cul data-start=\"6126\" data-end=\"6206\"\u003e\n\u003cli data-section-id=\"19te7am\" data-start=\"6126\" data-end=\"6206\"\u003eThe total capacity of indoor units must adhere to a specific ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6208\" data-end=\"6265\"\u003eIncorrect sizing reduces overall performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8qy7kh\" data-start=\"6267\" data-end=\"6300\"\u003e3. Non-optimized installation\u003c\/h3\u003e\n\u003cp data-start=\"6302\" data-end=\"6351\"\u003eWe have often corrected installations where:\u003c\/p\u003e\n\u003cul data-start=\"6353\" data-end=\"6460\"\u003e\n\u003cli data-section-id=\"1usr43w\" data-start=\"6353\" data-end=\"6392\"\u003eUnits were poorly positioned\u003c\/li\u003e\n\u003cli data-section-id=\"1qijaff\" data-start=\"6393\" data-end=\"6434\"\u003eRefrigerant lines were too long\u003c\/li\u003e\n\u003cli data-section-id=\"el2e5e\" data-start=\"6435\" data-end=\"6460\"\u003eDrainage was poorly designed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6462\" data-end=\"6516\"\u003eResult: loss of efficiency and recurring problems.\u003c\/p\u003e\n\u003chr data-start=\"6518\" data-end=\"6521\"\u003e\n\u003ch2 data-section-id=\"xb02qa\" data-start=\"6523\" data-end=\"6579\"\u003eWhy Choose AirGreen for this Type of Heat Pump\u003c\/h2\u003e\n\u003ch3 data-section-id=\"yztpuj\" data-start=\"6581\" data-end=\"6609\"\u003eReal field expertise\u003c\/h3\u003e\n\u003cp data-start=\"6611\" data-end=\"6678\"\u003eWe have installed hundreds of \u003cstrong data-start=\"6657\" data-end=\"6671\"\u003emulti-zone\u003c\/strong\u003e systems in:\u003c\/p\u003e\n\u003cul data-start=\"6680\" data-end=\"6743\"\u003e\n\u003cli data-section-id=\"16o4n0m\" data-start=\"6680\" data-end=\"6692\"\u003eMontreal\u003c\/li\u003e\n\u003cli data-section-id=\"xgss5a\" data-start=\"6693\" data-end=\"6702\"\u003eLaval\u003c\/li\u003e\n\u003cli data-section-id=\"14h1602\" data-start=\"6703\" data-end=\"6716\"\u003eLongueuil\u003c\/li\u003e\n\u003cli data-section-id=\"1dj10ua\" data-start=\"6717\" data-end=\"6729\"\u003eSouth Shore\u003c\/li\u003e\n\u003cli data-section-id=\"1xsjct3\" data-start=\"6730\" data-end=\"6743\"\u003eNorth Shore\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"vruznv\" data-start=\"6745\" data-end=\"6767\"\u003eConcrete advantages\u003c\/h3\u003e\n\u003cul data-start=\"6769\" data-end=\"6911\"\u003e\n\u003cli data-section-id=\"106psik\" data-start=\"6769\" data-end=\"6798\"\u003ePrecise thermal analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1bvavsm\" data-start=\"6799\" data-end=\"6841\"\u003eCertified professional installation\u003c\/li\u003e\n\u003cli data-section-id=\"15522dx\" data-start=\"6842\" data-end=\"6884\"\u003eWarranty and prompt after-sales service\u003c\/li\u003e\n\u003cli data-section-id=\"em796k\" data-start=\"6885\" data-end=\"6911\"\u003ePersonalized advice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1lc846u\" data-start=\"6913\" data-end=\"6938\"\u003eComplete transparency\u003c\/h3\u003e\n\u003cul data-start=\"6940\" data-end=\"7030\"\u003e\n\u003cli data-section-id=\"1q5fzz5\" data-start=\"6940\" data-end=\"6972\"\u003eDetailed prices before work\u003c\/li\u003e\n\u003cli data-section-id=\"1a29c2z\" data-start=\"6973\" data-end=\"6994\"\u003eNo hidden fees\u003c\/li\u003e\n\u003cli data-section-id=\"1sw0w8a\" data-start=\"6995\" data-end=\"7030\"\u003eAssistance with subsidies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"7032\" data-end=\"7035\"\u003e\n\u003ch2 data-section-id=\"rpu9me\" data-start=\"7037\" data-end=\"7100\"\u003eConclusion: A Reliable Heat Pump for the Quebec Climate\u003c\/h2\u003e\n\u003cp data-start=\"7102\" data-end=\"7205\"\u003eThe \u003cstrong data-start=\"7105\" data-end=\"7166\"\u003e2-zone DIRECT AIR HEAT XTREME PRO 36,000 BTU heat pump\u003c\/strong\u003e represents a robust solution for:\u003c\/p\u003e\n\u003cul data-start=\"7207\" data-end=\"7322\"\u003e\n\u003cli data-section-id=\"164canf\" data-start=\"7207\" data-end=\"7230\"\u003eExtreme winters\u003c\/li\u003e\n\u003cli data-section-id=\"93zijy\" data-start=\"7231\" data-end=\"7261\"\u003eMulti-zone homes\u003c\/li\u003e\n\u003cli data-section-id=\"1axlhdm\" data-start=\"7262\" data-end=\"7322\"\u003eOwners seeking performance and flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7324\" data-end=\"7521\"\u003eIts operation down to \u003cstrong data-start=\"7351\" data-end=\"7360\"\u003e-35°C\u003c\/strong\u003e, combined with its advanced features and multi-zone compatibility, makes it a strategic choice for improving comfort and reducing energy costs.\u003c\/p\u003e\n\u003chr data-start=\"7523\" data-end=\"7526\"\u003e\n\u003ch2 data-section-id=\"186ytx4\" data-start=\"7528\" data-end=\"7583\"\u003eContact AirGreen for a Personalized Quote\u003c\/h2\u003e\n\u003cp data-start=\"7585\" data-end=\"7702\"\u003eDo you want to install a \u003cstrong data-start=\"7614\" data-end=\"7701\"\u003emulti-zone heat pump in Montreal, Laval, Longueuil, on the North Shore, or the South Shore\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp data-start=\"7704\" data-end=\"7741\"\u003eContact us today for:\u003c\/p\u003e\n\u003cul data-start=\"7743\" data-end=\"7842\"\u003e\n\u003cli data-section-id=\"1n0y4w1\" data-start=\"7743\" data-end=\"7770\"\u003eA free evaluation\u003c\/li\u003e\n\u003cli data-section-id=\"1o2arri\" data-start=\"7771\" data-end=\"7799\"\u003eA detailed quote\u003c\/li\u003e\n\u003cli data-section-id=\"ec1ccq\" data-start=\"7800\" data-end=\"7842\"\u003eAdvice tailored to your property\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7844\" data-end=\"7949\"\u003eAirGreen supports you every step of the way, from selection to full installation of your HVAC system.\u003c\/p\u003e","brand":"Direct Air","offers":[{"title":"Default Title","offer_id":53305748914468,"sku":"DIRM-36HXPRO28-4Z-2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE2-TETEDIRECTAIRHEATXTREMEPRO_47065a70-3766-4a9b-8857-7273077341a2.png?v=1777635604","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-direct-air-heat-xtreme-pro-35-c-ext-36000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}