{"product_id":"thermopompe-2-zones-kinghome-ultra-heat-r32-60-000-btu-montreal-laval-rive-sud-rive-nord","title":"KINGHOME Ultra Heat R32 2-Zone Heat Pump | 60,000 BTU | Montréal, Laval, South Shore, North Shore","description":"\u003ch2\u003eTwo very large spaces, the biggest heads in the lineup\u003c\/h2\u003e\n\u003cp\u003eThis 60,000 BTU, two-zone \u003cstrong\u003emulti-zone heat pump\u003c\/strong\u003e is aimed at spaces the other models in the series can't serve: a cathedral-ceiling family room open to the kitchen, a fully finished basement in one open space, a showroom, a small shop with a back room, a professional office on the ground floor of a building. What sets it apart is access to the 30,000 and 36,000 BTU wall-mounted heads, which are reserved for the \u003cstrong\u003eKM60X6O\u003c\/strong\u003e outdoor unit in the Ultra Heat lineup.\u003c\/p\u003e\n\u003cp\u003eWe recommend it in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e when two large spaces need to be handled with a single outdoor unit, and cooling weighs heavily in the choice.\u003c\/p\u003e\n\u003ch3\u003eWhat you need to know first: no cold climate designation\u003c\/h3\u003e\n\u003cp\u003eWe want to be upfront about this. This unit is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified, but it \u003cstrong\u003edoes not carry the ENERGY STAR cold climate designation\u003c\/strong\u003e, unlike the lower-capacity models in the same series. Some sales materials give this designation to the entire lineup; the official certificates say otherwise for this model. That's also why its \u003cstrong\u003eLogisVert assistance\u003c\/strong\u003e is much more modest than that of the cold-climate certified models.\u003c\/p\u003e\n\u003cp\u003eThat doesn't mean the unit shuts down in winter. Its heating operating range goes down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e. But the capacity it delivers in extreme cold is proportionally lower, and that has to be factored into the design. The values listed on NEEP (AHRI No. 218389037) show it:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: \u003cstrong\u003e41,000 BTU\/h\u003c\/strong\u003e, with a COP of 2.58, or about 68% of the nominal capacity.\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e36,400 BTU\/h\u003c\/strong\u003e, with a COP of 1.9, or about 61%.\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: \u003cstrong\u003e20,000 BTU\/h\u003c\/strong\u003e, with a COP of 1.25, or about 33%.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor two large spaces, the takeaway is simple: this system handles fall, spring and ordinary winter days very well, and it cools with plenty of reserve in summer. In extreme cold, backup heat has to be in place. We deal with that from the design stage rather than leaving it to chance.\u003c\/p\u003e\n\u003ch3\u003eThe right partner: existing backup heat\u003c\/h3\u003e\n\u003cp\u003eThe most logical setup is dual energy: the heat pump does the heating for most of the winter, and the existing system, whether baseboards, a furnace or a boiler, takes over when the outdoor temperature drops. The lineup offers a dual-energy control that links the heat pump to a thermostat and switches automatically to the backup source when the heat pump can no longer keep up. Even at -30 °C, with a COP of 1.25, the heat pump still produces more heat per unit of electricity than a baseboard.\u003c\/p\u003e\n\u003ch3\u003eTwo heads: 24,000 and 36,000 BTU\u003c\/h3\u003e\n\u003cp\u003eThis unit accepts the CHARMO wall-mounted heads \u003cstrong\u003eKW09XQ19CDI\u003c\/strong\u003e, \u003cstrong\u003eKW12XQ19CDI\u003c\/strong\u003e, \u003cstrong\u003eKW18XQ19CDI\u003c\/strong\u003e, \u003cstrong\u003eKW24XQ19CDI\u003c\/strong\u003e, \u003cstrong\u003eKW30XQ21CDI\u003c\/strong\u003e and \u003cstrong\u003eKW36XQ21CDI\u003c\/strong\u003e, from 9,000 to 36,000 BTU. For two zones, the typical combination is a 36,000 BTU head for the larger space and a 24,000 BTU head for the second one, which adds up to the outdoor unit's 60,000 BTU. Two 30,000 BTU heads work well when both spaces are about the same.\u003c\/p\u003e\n\u003cp\u003eA big head in a large space needs room in front of it to throw the air all the way to the back of the room. We put it on the longest wall, up high, facing the occupied area, never at the back of a recess. The automatic vertical and horizontal louvres spread the airflow. \u003cstrong\u003eWi-Fi is included\u003c\/strong\u003e: both zones can be controlled from the KINGHOME PLUS app or by voice control with Google Assistant and Amazon Alexa. Both heads always run in the same mode, heating or cooling.\u003c\/p\u003e\n\u003ch3\u003eIn a commercial space\u003c\/h3\u003e\n\u003cp\u003eIn a shop, an office or a showroom, the cooling load almost always dominates: lighting, equipment, customers and display windows add heat all year round. A 36,000 BTU head in the main space and a 24,000 BTU head in the back room or the office give you two independent set points, with a single unit outside, often in a back lane or a yard where space is tight. For commercial use, the manufacturer's warranty terms are shorter than for residential use; we give them to you in writing with the quote.\u003c\/p\u003e\n\u003ch3\u003eEfficiency ratings\u003c\/h3\u003e\n\u003cp\u003eThe system is rated at \u003cstrong\u003e21 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.65 EER2\u003c\/strong\u003e and \u003cstrong\u003e10 HSPF2\u003c\/strong\u003e, uses \u003cstrong\u003eR-32\u003c\/strong\u003e refrigerant, and has a twin rotary compressor and an electronic expansion valve.\u003c\/p\u003e\n\u003ch2\u003eWhat we check before the installation\u003c\/h2\u003e\n\u003ch3\u003eThe electrical supply\u003c\/h3\u003e\n\u003cp\u003eThe unit requires a \u003cstrong\u003e220 V\u003c\/strong\u003e supply, an \u003cstrong\u003eMCA of 38 A\u003c\/strong\u003e and an \u003cstrong\u003eMOP of 40 A\u003c\/strong\u003e. That's the highest electrical demand in the series: we check the capacity of the service, the space in the panel and, in a commercial space, compatibility with the existing supply. Both heads are powered from the outdoor unit through the interconnecting cable.\u003c\/p\u003e\n\u003ch3\u003eWhere the outdoor unit goes\u003c\/h3\u003e\n\u003cp\u003eThe unit has a vertical format: \u003cstrong\u003e35.43 x 13.39 x 49.61 inches\u003c\/strong\u003e, taller than it is wide, with a sound level of \u003cstrong\u003e60 dB(A)\u003c\/strong\u003e. That format fits well along a narrow side wall or in a building's backyard. We set it on a raised stand or a support designed for its weight, above snow level, with enough clearance for the defrost water to drain.\u003c\/p\u003e\n\u003ch3\u003eThe piping\u003c\/h3\u003e\n\u003cp\u003eThe connections are \u003cstrong\u003e1\/4 and 1\/2 inch\u003c\/strong\u003e, depending on the port. The high-capacity heads are connected to the outdoor unit's large-diameter ports, and each circuit is vacuumed separately.\u003c\/p\u003e\n\u003ch3\u003eThe drains\u003c\/h3\u003e\n\u003cp\u003eA 36,000 BTU head produces a lot of condensate in cooling mode. Its drain needs a steady slope to the outside or to a floor drain; in a commercial space, we check access to the plumbing. A condensate pump is planned when a proper slope isn't possible.\u003c\/p\u003e\n\u003ch3\u003eLogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eindicative LogisVert amount\u003c\/strong\u003e for this system is \u003cstrong\u003e$2,050\u003c\/strong\u003e, calculated using the LogisVert rule ($50 per 1,000 BTU\/h of certified heating capacity at -8.3 °C, the rate for a unit without a cold climate designation); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are \u003cstrong\u003eAHRI 218389037\u003c\/strong\u003e and \u003cstrong\u003eENERGY STAR ID 4610343\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians, residential and light commercial.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration done for you.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service that knows your installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we assess your two spaces, your backup heat and your electrical supply, then tell you frankly whether this model is the right choice.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on models registered for residential use.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959624499492,"sku":"KM60X6O-99","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_2_ZONES_KINGHOME_ULTRA_HEAT_R32_60_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291368","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-2-zones-kinghome-ultra-heat-r32-60-000-btu-montreal-laval-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}