{"product_id":"thermopompe-3-tetes-direct-air-da25-25-c-ext-27000-btu","title":"3-Head Heat Pump DIRECT AIR DA25 (-25°C) | Ext: 27000 BTU","description":"\u003ch2 data-section-id=\"m4ha0i\" data-start=\"82\" data-end=\"162\"\u003eA Reliable and High-Performance Multi-Zone HVAC Solution for Quebec's Realities\u003c\/h2\u003e\n\u003cp data-start=\"164\" data-end=\"565\"\u003eAt AirGreen, we regularly install \u003cstrong data-start=\"222\" data-end=\"236\"\u003emulti-zone\u003c\/strong\u003e systems in homes in \u003cstrong data-start=\"259\" data-end=\"322\"\u003eMontreal, Laval, Longueuil, on the North Shore and the South Shore\u003c\/strong\u003e, where heating and cooling needs vary greatly from room to room. The \u003cstrong data-start=\"413\" data-end=\"464\"\u003eDIRECT AIR DA25 (27000 BTU) 3-head heat pump\u003c\/strong\u003e stands out as a structured, efficient solution perfectly adapted to this type of configuration.\u003c\/p\u003e\n\u003cp data-start=\"567\" data-end=\"852\"\u003eThis model allows connecting \u003cstrong data-start=\"597\" data-end=\"629\"\u003eup to 3 indoor units\u003c\/strong\u003e to a single outdoor unit, thus offering independent temperature control in each zone. In an urban context where condos, plexes, and multi-story houses are common, this flexibility becomes essential.\u003c\/p\u003e\n\u003chr data-start=\"854\" data-end=\"857\"\u003e\n\u003ch2 data-section-id=\"oao0mi\" data-start=\"859\" data-end=\"924\"\u003eA Heat Pump Designed for Montreal's Climate (Actual -25°C)\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1d7cjtd\" data-start=\"926\" data-end=\"978\"\u003eHeating Performance Even in Harsh Winters\u003c\/h3\u003e\n\u003cp data-start=\"980\" data-end=\"1250\"\u003eThe DIRECT AIR DA25 is designed to operate efficiently down to \u003cstrong data-start=\"1048\" data-end=\"1057\"\u003e-25°C\u003c\/strong\u003e, which corresponds to the winter realities of Greater Montreal. Unlike many standard systems, it maintains significant heating capacity even in extreme conditions:\u003c\/p\u003e\n\u003cul data-start=\"1252\" data-end=\"1366\"\u003e\n\u003cli data-section-id=\"1r6m5fm\" data-start=\"1252\" data-end=\"1291\"\u003e\n\u003cstrong data-start=\"1254\" data-end=\"1276\"\u003eNominal Power\u003c\/strong\u003e: 27,000 BTU\u003c\/li\u003e\n\u003cli data-section-id=\"pr8xy8\" data-start=\"1292\" data-end=\"1328\"\u003e\n\u003cstrong data-start=\"1294\" data-end=\"1313\"\u003eCapacity at -8°C\u003c\/strong\u003e: 21,000 BTU\u003c\/li\u003e\n\u003cli data-section-id=\"4l50tz\" data-start=\"1329\" data-end=\"1366\"\u003e\n\u003cstrong data-start=\"1331\" data-end=\"1351\"\u003eCapacity at -15°C\u003c\/strong\u003e: 19,000 BTU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1368\" data-end=\"1578\"\u003eIn our installations in Laval and on the South Shore, we observe that this performance stability avoids excessive reliance on electric backup systems, which directly reduces energy costs.\u003c\/p\u003e\n\u003ch3 data-section-id=\"avngug\" data-start=\"1580\" data-end=\"1623\"\u003eMeasured and Concrete Energy Efficiency\u003c\/h3\u003e\n\u003cp data-start=\"1625\" data-end=\"1668\"\u003eThis system offers solid performance:\u003c\/p\u003e\n\u003cul data-start=\"1670\" data-end=\"1756\"\u003e\n\u003cli data-section-id=\"ty5x5o\" data-start=\"1670\" data-end=\"1690\"\u003e\u003cstrong data-start=\"1672\" data-end=\"1690\"\u003eSEER2: 24.630\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"15ojjju\" data-start=\"1691\" data-end=\"1711\"\u003e\u003cstrong data-start=\"1693\" data-end=\"1711\"\u003eHSPF2: 19.515\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1lz7cdm\" data-start=\"1712\" data-end=\"1731\"\u003e\u003cstrong data-start=\"1714\" data-end=\"1731\"\u003eEER2: 12.720\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"6r1hnq\" data-start=\"1732\" data-end=\"1756\"\u003e\u003cstrong data-start=\"1734\" data-end=\"1756\"\u003eCOP at -8°C: 12.03\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1758\" data-end=\"1874\"\u003eThese values demonstrate interesting efficiency, particularly for prolonged heating during the Quebec winter.\u003c\/p\u003e\n\u003chr data-start=\"1876\" data-end=\"1879\"\u003e\n\u003ch2 data-section-id=\"13my7x3\" data-start=\"1881\" data-end=\"1944\"\u003eMulti-zone Configuration: Flexibility and Real Optimization\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1edd77w\" data-start=\"1946\" data-end=\"1988\"\u003eIntelligent Operation of the 3 Zones\u003c\/h3\u003e\n\u003cp data-start=\"1990\" data-end=\"2071\"\u003eThe \u003cstrong data-start=\"2007\" data-end=\"2018\"\u003e3-zone\u003c\/strong\u003e configuration allows connecting different indoor units:\u003c\/p\u003e\n\u003cul data-start=\"2073\" data-end=\"2160\"\u003e\n\u003cli data-section-id=\"3mx47l\" data-start=\"2073\" data-end=\"2094\"\u003e9,000 BTU (bedroom)\u003c\/li\u003e\n\u003cli data-section-id=\"h2h13a\" data-start=\"2095\" data-end=\"2115\"\u003e12,000 BTU (living room)\u003c\/li\u003e\n\u003cli data-section-id=\"gadzny\" data-start=\"2116\" data-end=\"2160\"\u003e18,000 BTU (open concept area or entire floor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2162\" data-end=\"2432\"\u003eAccording to the combination rule indicated in the technical documentation, the total capacity of the indoor units must remain within a precise range to ensure optimal operation. This logic is essential to avoid heating performance losses.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iqfzeg\" data-start=\"2434\" data-end=\"2474\"\u003eReal-world AirGreen Installation Example\u003c\/h3\u003e\n\u003cp data-start=\"2476\" data-end=\"2546\"\u003eIn Longueuil, we recently installed this system in a duplex:\u003c\/p\u003e\n\u003cul data-start=\"2548\" data-end=\"2649\"\u003e\n\u003cli data-section-id=\"x8hr3j\" data-start=\"2548\" data-end=\"2580\"\u003eMain living room: 12,000 BTU\u003c\/li\u003e\n\u003cli data-section-id=\"o1ul7h\" data-start=\"2581\" data-end=\"2615\"\u003eMaster bedroom: 9,000 BTU\u003c\/li\u003e\n\u003cli data-section-id=\"shxcn5\" data-start=\"2616\" data-end=\"2649\"\u003eFinished basement: 12,000 BTU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2651\" data-end=\"2661\"\u003eResult:\u003c\/p\u003e\n\u003cul data-start=\"2662\" data-end=\"2797\"\u003e\n\u003cli data-section-id=\"15zsru0\" data-start=\"2662\" data-end=\"2699\"\u003eStable temperature in each zone\u003c\/li\u003e\n\u003cli data-section-id=\"1tkn0w7\" data-start=\"2700\" data-end=\"2753\"\u003eApproximate 28% reduction in electricity consumption\u003c\/li\u003e\n\u003cli data-section-id=\"c3x3aw\" data-start=\"2754\" data-end=\"2797\"\u003eNo perceptible noise in bedrooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2799\" data-end=\"2802\"\u003e\n\u003ch2 data-section-id=\"15zoegv\" data-start=\"2804\" data-end=\"2852\"\u003eAdvanced Indoor Comfort and Air Control\u003c\/h2\u003e\n\u003ch3 data-section-id=\"150zoc9\" data-start=\"2854\" data-end=\"2889\"\u003eIntelligent Air Distribution\u003c\/h3\u003e\n\u003cp data-start=\"2891\" data-end=\"2927\"\u003eEach indoor unit features:\u003c\/p\u003e\n\u003cul data-start=\"2929\" data-end=\"3054\"\u003e\n\u003cli data-section-id=\"1o9vbzi\" data-start=\"2929\" data-end=\"2979\"\u003e\u003cstrong data-start=\"2931\" data-end=\"2979\"\u003eAutomatic vertical and horizontal louvers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"96qpu8\" data-start=\"2980\" data-end=\"3014\"\u003e\u003cstrong data-start=\"2982\" data-end=\"3014\"\u003ePosition memory function\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"e25wco\" data-start=\"3015\" data-end=\"3054\"\u003eUniform diffusion without cold spots\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3056\" data-end=\"3176\"\u003eThis eliminates a common problem observed in low-end installations: overheated or poorly ventilated areas.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1c8mxli\" data-start=\"3178\" data-end=\"3211\"\u003eSilence and Acoustic Comfort\u003c\/h3\u003e\n\u003cul data-start=\"3213\" data-end=\"3294\"\u003e\n\u003cli data-section-id=\"16ep19f\" data-start=\"3213\" data-end=\"3260\"\u003eIndoor sound level: \u003cstrong data-start=\"3241\" data-end=\"3260\"\u003e22.5 to 36 dB(A)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"z1rkve\" data-start=\"3261\" data-end=\"3294\"\u003eOutdoor sound level: \u003cstrong data-start=\"3282\" data-end=\"3294\"\u003e61 dB(A)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3296\" data-end=\"3477\"\u003eIn Montreal condos, this factor is often decisive. We have already replaced noisier systems with this model, with immediate customer feedback on sound comfort.\u003c\/p\u003e\n\u003chr data-start=\"3479\" data-end=\"3482\"\u003e\n\u003ch2 data-section-id=\"1d9mbxt\" data-start=\"3484\" data-end=\"3537\"\u003eIntegrated Technologies and Modern Features\u003c\/h2\u003e\n\u003cp data-start=\"3539\" data-end=\"3649\"\u003eAccording to the technical information for the DA25 series, this system includes several essential features:\u003c\/p\u003e\n\u003cul data-start=\"3651\" data-end=\"3920\"\u003e\n\u003cli data-section-id=\"enagqb\" data-start=\"3651\" data-end=\"3678\"\u003e\u003cstrong data-start=\"3653\" data-end=\"3678\"\u003eAutomatic defrosting\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"8v8p36\" data-start=\"3679\" data-end=\"3708\"\u003e\u003cstrong data-start=\"3681\" data-end=\"3708\"\u003eAutomatic restart\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"r408ja\" data-start=\"3709\" data-end=\"3728\"\u003e\u003cstrong data-start=\"3711\" data-end=\"3728\"\u003e24h timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"16si2ht\" data-start=\"3729\" data-end=\"3752\"\u003e\u003cstrong data-start=\"3731\" data-end=\"3752\"\u003eEco and turbo modes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1n1ti3d\" data-start=\"3753\" data-end=\"3772\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3772\"\u003eSelf-cleaning\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"uk6hcj\" data-start=\"3773\" data-end=\"3815\"\u003e\u003cstrong data-start=\"3775\" data-end=\"3815\"\u003eMotion and humidity sensor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"3y144g\" data-start=\"3816\" data-end=\"3866\"\u003e\u003cstrong data-start=\"3818\" data-end=\"3866\"\u003eBiofilter to improve air quality\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"19dc6yr\" data-start=\"3867\" data-end=\"3920\"\u003e\u003cstrong data-start=\"3869\" data-end=\"3920\"\u003eOptional WiFi (smart home compatible)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3922\" data-end=\"4141\"\u003eIn several installations in Boucherville, our clients opted for the WiFi module to manage the temperature remotely, which is particularly useful for secondary residences or rental properties.\u003c\/p\u003e\n\u003chr data-start=\"4143\" data-end=\"4146\"\u003e\n\u003ch2 data-section-id=\"v7988k\" data-start=\"4148\" data-end=\"4208\"\u003eHVAC Installation: What You Need to Know Before Choosing\u003c\/h2\u003e\n\u003ch3 data-section-id=\"a3346u\" data-start=\"4210\" data-end=\"4247\"\u003eCritical Points Often Overlooked\u003c\/h3\u003e\n\u003cp data-start=\"4249\" data-end=\"4313\"\u003eAt AirGreen, we have observed several common mistakes:\u003c\/p\u003e\n\u003cul data-start=\"4315\" data-end=\"4456\"\u003e\n\u003cli data-section-id=\"1o2z55w\" data-start=\"4315\" data-end=\"4359\"\u003eIncorrect capacity selection per room\u003c\/li\u003e\n\u003cli data-section-id=\"ssouga\" data-start=\"4360\" data-end=\"4406\"\u003ePoor management of piping lengths\u003c\/li\u003e\n\u003cli data-section-id=\"1rda7k9\" data-start=\"4407\" data-end=\"4456\"\u003eInadequate positioning of indoor units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4458\" data-end=\"4485\"\u003eThe DIRECT AIR DA25 allows for:\u003c\/p\u003e\n\u003cul data-start=\"4487\" data-end=\"4613\"\u003e\n\u003cli data-section-id=\"uiwm0f\" data-start=\"4487\" data-end=\"4531\"\u003eUp to \u003cstrong data-start=\"4497\" data-end=\"4531\"\u003e60 meters of total piping\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q7xye2\" data-start=\"4532\" data-end=\"4568\"\u003eMulti-level installation\u003c\/li\u003e\n\u003cli data-section-id=\"18l5ufn\" data-start=\"4569\" data-end=\"4613\"\u003eFlexibility for complex renovations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4615\" data-end=\"4696\"\u003eBut without professional installation, these benefits can be compromised.\u003c\/p\u003e\n\u003chr data-start=\"4698\" data-end=\"4701\"\u003e\n\u003ch2 data-section-id=\"1fupy1q\" data-start=\"4703\" data-end=\"4737\"\u003eEssential Technical Data\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1id0ql1\" data-start=\"4739\" data-end=\"4759\"\u003eOutdoor Unit\u003c\/h3\u003e\n\u003cul data-start=\"4761\" data-end=\"4901\"\u003e\n\u003cli data-section-id=\"daqvu1\" data-start=\"4761\" data-end=\"4790\"\u003eModel: \u003cstrong data-start=\"4772\" data-end=\"4790\"\u003eDIRM-27DA25-3Z\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"b7kwcw\" data-start=\"4791\" data-end=\"4807\"\u003eVoltage: 220V\u003c\/li\u003e\n\u003cli data-section-id=\"11hqoc9\" data-start=\"4808\" data-end=\"4834\"\u003eSound level: 61 dB(A)\u003c\/li\u003e\n\u003cli data-section-id=\"1l44w5f\" data-start=\"4835\" data-end=\"4874\"\u003eDimensions: 37.24 × 16.14 × 31.89 in\u003c\/li\u003e\n\u003cli data-section-id=\"1l0o8u0\" data-start=\"4875\" data-end=\"4901\"\u003eRefrigerant: \u003cstrong data-start=\"4891\" data-end=\"4901\"\u003eR-410A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tiiore\" data-start=\"4903\" data-end=\"4937\"\u003eCompatible Indoor Units\u003c\/h3\u003e\n\u003cul data-start=\"4939\" data-end=\"4989\"\u003e\n\u003cli data-section-id=\"1nplu2z\" data-start=\"4939\" data-end=\"4955\"\u003eDIRM-09DA25-WM\u003c\/li\u003e\n\u003cli data-section-id=\"1bwvrmp\" data-start=\"4956\" data-end=\"4972\"\u003eDIRM-12DA25-WM\u003c\/li\u003e\n\u003cli data-section-id=\"rrrk6j\" data-start=\"4973\" data-end=\"4989\"\u003eDIRM-18DA25-WM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bmuquy\" data-start=\"4991\" data-end=\"5030\"\u003eOther Important Features\u003c\/h3\u003e\n\u003cul data-start=\"5032\" data-end=\"5141\"\u003e\n\u003cli data-section-id=\"y9sq55\" data-start=\"5032\" data-end=\"5056\"\u003e\u003cstrong data-start=\"5034\" data-end=\"5056\"\u003eEnergy Star®: Yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"26x1q4\" data-start=\"5057\" data-end=\"5091\"\u003eLogisVert Subsidy: \u003cstrong data-start=\"5082\" data-end=\"5091\"\u003e$1050\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lupwbi\" data-start=\"5092\" data-end=\"5141\"\u003eWarranty: \u003cstrong data-start=\"5105\" data-end=\"5141\"\u003e5 years compressor \/ 5 years parts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5143\" data-end=\"5146\"\u003e\n\u003ch2 data-section-id=\"dl9q6r\" data-start=\"5148\" data-end=\"5215\"\u003eAirGreen Feedback: Real-world Performance\u003c\/h2\u003e\n\u003cp data-start=\"5217\" data-end=\"5325\"\u003eIn a recent project in Laval (intergenerational home), we installed this system to replace:\u003c\/p\u003e\n\u003cul data-start=\"5327\" data-end=\"5395\"\u003e\n\u003cli data-section-id=\"jr6vjp\" data-start=\"5327\" data-end=\"5358\"\u003e3 old wall-mounted air conditioners\u003c\/li\u003e\n\u003cli data-section-id=\"aidaz1\" data-start=\"5359\" data-end=\"5395\"\u003eInefficient electric heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5397\" data-end=\"5431\"\u003eResults after a full winter:\u003c\/p\u003e\n\u003cul data-start=\"5433\" data-end=\"5542\"\u003e\n\u003cli data-section-id=\"grkaln\" data-start=\"5433\" data-end=\"5475\"\u003eReduction in energy costs: 32%\u003c\/li\u003e\n\u003cli data-section-id=\"1c4i6pa\" data-start=\"5476\" data-end=\"5517\"\u003eConsistent comfort in all rooms\u003c\/li\u003e\n\u003cli data-section-id=\"7yrgs0\" data-start=\"5518\" data-end=\"5542\"\u003eNo service calls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5544\" data-end=\"5627\"\u003eThis type of result confirms that this system is well adapted to local conditions.\u003c\/p\u003e\n\u003chr data-start=\"5629\" data-end=\"5632\"\u003e\n\u003ch2 data-section-id=\"1vpk502\" data-start=\"5634\" data-end=\"5691\"\u003eWhy Choose AirGreen for Your HVAC Installation\u003c\/h2\u003e\n\u003cp data-start=\"5693\" data-end=\"5767\"\u003eWe don't just install heat pumps. We analyze:\u003c\/p\u003e\n\u003cul data-start=\"5769\" data-end=\"5858\"\u003e\n\u003cli data-section-id=\"s58zhr\" data-start=\"5769\" data-end=\"5808\"\u003eThe complete building configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1mf5ibu\" data-start=\"5809\" data-end=\"5832\"\u003eThermal losses\u003c\/li\u003e\n\u003cli data-section-id=\"10kt24\" data-start=\"5833\" data-end=\"5858\"\u003eThe actual use of the rooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5860\" data-end=\"5952\"\u003eThis allows us to optimize every project in Montreal, Laval, Longueuil, North Shore, and South Shore.\u003c\/p\u003e\n\u003cp data-start=\"5954\" data-end=\"5969\"\u003eOur advantages:\u003c\/p\u003e\n\u003cul data-start=\"5971\" data-end=\"6164\"\u003e\n\u003cli data-section-id=\"1vk625\" data-start=\"5971\" data-end=\"6014\"\u003e\u003cstrong data-start=\"5973\" data-end=\"6014\"\u003eCertified and experienced refrigerating technicians\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"t900s2\" data-start=\"6015\" data-end=\"6054\"\u003e\u003cstrong data-start=\"6017\" data-end=\"6054\"\u003eFast and structured installation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1cc468q\" data-start=\"6055\" data-end=\"6089\"\u003e\u003cstrong data-start=\"6057\" data-end=\"6089\"\u003eTotal price transparency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"z3bn9y\" data-start=\"6090\" data-end=\"6124\"\u003e\u003cstrong data-start=\"6092\" data-end=\"6124\"\u003eEfficient after-sales support\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"qp6zvp\" data-start=\"6125\" data-end=\"6164\"\u003e\u003cstrong data-start=\"6127\" data-end=\"6164\"\u003eInsurance coverage of $5,000,000\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6166\" data-end=\"6169\"\u003e\n\u003ch2 data-section-id=\"12v0uq1\" data-start=\"6171\" data-end=\"6242\"\u003eConclusion: A Reliable Multi-Zone Solution Well Suited for Quebec\u003c\/h2\u003e\n\u003cp data-start=\"6244\" data-end=\"6404\"\u003eThe \u003cstrong data-start=\"6247\" data-end=\"6298\"\u003eDIRECT AIR DA25 (27000 BTU) 3-head heat pump\u003c\/strong\u003e represents a solid option for homes requiring precise zone control. It combines:\u003c\/p\u003e\n\u003cul data-start=\"6406\" data-end=\"6526\"\u003e\n\u003cli data-section-id=\"5bbbgz\" data-start=\"6406\" data-end=\"6435\"\u003eCold climate performance\u003c\/li\u003e\n\u003cli data-section-id=\"ptg7t0\" data-start=\"6436\" data-end=\"6464\"\u003eInstallation flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"1dbxspv\" data-start=\"6465\" data-end=\"6492\"\u003eGood energy efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"1pl9i99\" data-start=\"6493\" data-end=\"6526\"\u003eAcoustic and thermal comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6528\" data-end=\"6630\"\u003eIt is a consistent choice for homeowners wishing to modernize their HVAC system without compromise.\u003c\/p\u003e\n\u003chr data-start=\"6632\" data-end=\"6635\"\u003e\n\u003ch2 data-section-id=\"186ytx4\" data-start=\"6637\" data-end=\"6692\"\u003eContact AirGreen for a Personalized Quote\u003c\/h2\u003e\n\u003cp data-start=\"6694\" data-end=\"6921\"\u003eTo obtain a precise evaluation of your project in \u003cstrong data-start=\"6748\" data-end=\"6811\"\u003eMontreal, Laval, Longueuil, on the North Shore, or the South Shore\u003c\/strong\u003e, contact our team today. We will offer you a tailored, clear, and no-surprise solution.\u003c\/p\u003e","brand":"Direct Air","offers":[{"title":"Default Title","offer_id":53305724010788,"sku":"DIRM-27DA25-3Z-3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE3-TETEDIRECTAIRDA25.png?v=1777635776","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-3-tetes-direct-air-da25-25-c-ext-27000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}