{"product_id":"thermopompe-3-zones-arcoaire-d5cmha-24000-btu-r454b","title":"3-Zone Heat Pump ARCOAIRE D5CMHA | 24,000 BTU - R454B","description":"\u003ch2\u003eA comfortable bedroom floor, summer and winter\u003c\/h2\u003e\u003cp\u003eOn the upper floor of a two-storey house, heat rises, the roof bakes all afternoon and the bedrooms become the hardest rooms to keep comfortable. The \u003cstrong\u003e3-Zone Heat Pump ARCOAIRE D5CMHA | 24,000 BTU - R454B\u003c\/strong\u003e answers this with one head per bedroom. Its \u003cstrong\u003e2-ton\u003c\/strong\u003e \u003cstrong\u003eD5CMHAH24DAK\u003c\/strong\u003e condenser serves \u003cstrong\u003e3 zones\u003c\/strong\u003e (up to 3 at most), and each of the three rooms keeps its own set point. The heads are chosen from the \u003cstrong\u003eD5FSHAH06XAK\u003c\/strong\u003e, \u003cstrong\u003eD5FSHAH09XAK\u003c\/strong\u003e and \u003cstrong\u003eD5FSHAH12XAK\u003c\/strong\u003e \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e models, according to the size of each bedroom.\u003c\/p\u003e\u003cp\u003eThe system is rated \u003cstrong\u003e24.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e13.0 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e. It is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 3722876\u003c\/strong\u003e, the certificate still lists its capacity at \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $3,480\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eConfigurations with three small rooms\u003c\/h3\u003e\u003cp\u003eThe typical case: three bedrooms under the roof of a two-storey house, a primary bedroom and two children's rooms. Other combinations work just as well: a bedroom, a home office and a playroom, or three closed rooms in a bungalow whose living room is already equipped. What these cases share are modestly sized rooms, separated by doors, that the heat of a single head cannot reach.\u003c\/p\u003e\u003cp\u003eThis size is not meant for a large open area. If one of the three zones is a spacious living room or an entire basement, a larger condenser will give a better margin. A poorly insulated attic, bedrooms with sloped walls or dormers facing due south also increase the load; the room-by-room assessment decides.\u003c\/p\u003e\u003ch3\u003eHow three heads share 24,000 BTU\u003c\/h3\u003e\u003cp\u003eThe condenser does not divide its capacity into three equal parts. It meters the refrigerant sent to each head according to its demand, and its \u003cstrong\u003einverter compressor\u003c\/strong\u003e adjusts its speed to the total. This sharing works well upstairs because the three rooms rarely call at full demand at the same time: the office works by day, the bedrooms mostly in the evening and at night, and a guest room can stay at a reduced set point most of the time. All heads do, however, work in the same mode at any given time, heating or cooling.\u003c\/p\u003e\u003cp\u003eThe most demanding moment is a cold January night when all three bedrooms call for heat together. That is the scenario we check in the \u003cstrong\u003eon-site assessment\u003c\/strong\u003e, adding up the needs of the three rooms rather than looking at each one in isolation.\u003c\/p\u003e\u003ch3\u003eA condenser fully used from day one\u003c\/h3\u003e\u003cp\u003eWith three heads, the D5CMHAH24DAK uses all its ports. There is therefore no possible fourth zone on this condenser; if a finished basement is added later, it will need a separate solution. The advantage is that the system is fully planned from the start: the total of the three heads must stay within the combinations the manufacturer allows, and we choose the sizes accordingly. A small child's bedroom often gets the D5FSHAH06XAK head, the most compact on the list, while the primary bedroom takes a larger size.\u003c\/p\u003e\u003ch3\u003eWhere to place a head in a bedroom\u003c\/h3\u003e\u003cp\u003eA bedroom wall head does not go just anywhere. We avoid having it blow directly on the bed, we place it so the air runs along the ceiling and comes down at the other end of the room, and we keep clearance above it for access to the filter. On an exterior wall, the line route is short and discreet; on an interior wall, the route has to be planned through the attic or a closet. Each head has its own remote: the primary bedroom's night set point does not have to be the same as the baby's room.\u003c\/p\u003e\u003ch3\u003eSummer under the roof: cooling and humidity\u003c\/h3\u003e\u003cp\u003eUpstairs bedrooms are the ones that build up the most heat in July. Each room's head removes that heat as it comes, and the variable-speed compressor runs for long periods at low speed, which gives the coil time to pull moisture out of the air. The result is felt at bedtime: cool, dry air, without the on-off cycling of a window air conditioner. The \u003cstrong\u003e13.0 EER2\u003c\/strong\u003e rating measures \u003cstrong\u003ecooling\u003c\/strong\u003e efficiency on the hottest days, and the \u003cstrong\u003edehumidification\u003c\/strong\u003e mode is useful on humid evenings when the temperature stays mild.\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eR-454B\u003c\/strong\u003e circulating in the system is a new-generation refrigerant, with a global warming potential markedly lower than that of the fluids it replaces. Mildly flammable, it is handled according to precise rules that our installers apply at every connection.\u003c\/p\u003e\u003ch3\u003eWinter: what the certificate shows\u003c\/h3\u003e\u003cp\u003eUpstairs, winter is less demanding than on the ground floor, because part of the heat from below rises naturally. The system's certificate lists \u003cstrong\u003e23,600 BTU\/h at -8 °C\u003c\/strong\u003e and \u003cstrong\u003e25,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published.\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCOP of 2.50 at the -8 °C point\u003c\/li\u003e\u003cli\u003eCOP of 2.00 at the -15 °C point\u003c\/li\u003e\u003cli\u003eMaximum capacity at -30 °C: 14,000 BTU\/h, COP of 1.30\u003c\/li\u003e\u003cli\u003eHeating certified down to -30 °C\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eIn deep cold, the published capacity drops; the bedrooms' existing baseboards remain useful as backup, especially in a corner room under the roof. These figures come from certificate \u003cstrong\u003eAHRI 215357131\u003c\/strong\u003e, published by NEEP.\u003c\/p\u003e\u003ch3\u003eWhat SEER2, HSPF2 and COP mean\u003c\/h3\u003e\u003cp\u003eThe 24.0 \u003cstrong\u003eSEER2\u003c\/strong\u003e sums up cooling efficiency over a full season; the 10.0 \u003cstrong\u003eHSPF2\u003c\/strong\u003e does the same for \u003cstrong\u003eheating\u003c\/strong\u003e, the most expensive season in Quebec. The higher these ratings, the less each unit of comfort costs in electricity. \u003cstrong\u003eCOP\u003c\/strong\u003e is even simpler to read: it is the number of units of heat delivered for each unit of electricity, at a given temperature. An electric baseboard always has a one-to-one ratio; the heat pump exceeds it at each of the published points, including at -30 °C.\u003c\/p\u003e\u003ch3\u003eIndicative LogisVert amount: $3,480\u003c\/h3\u003e\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$3,480\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\u003ch2\u003eThe job, from the facade to the bedrooms\u003c\/h2\u003e\u003ch3\u003eLines and drains up to the second floor\u003c\/h3\u003e\u003cp\u003eAfter the \u003cstrong\u003ein-home assessment\u003c\/strong\u003e, we plan the route of the three refrigerant line sets. Upstairs, they usually run up an exterior wall, grouped under a finishing cover, or pass through the attic when the facade does not lend itself to it. Each head has its own drain: by gravity along the exterior wall when possible, otherwise through a discreet condensate pump. The condenser goes on the ground on a stand or higher up on a wall bracket, always above the snow line and away from snow sliding off the roof. It is connected to a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, after checking the capacity of the electrical panel. Commissioning includes the leak test, the vacuum, a check of each of the three zones and programming the remotes with you.\u003c\/p\u003e\u003ch3\u003eMaintaining the three heads\u003c\/h3\u003e\u003cp\u003eAllow a few minutes per bedroom: open the front panel, remove the filter, rinse it and let it dry. In season, this is done every two weeks. Outside, keep the condenser free of snow and leaves, with no cover in winter. An annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e visit deep-cleans the coils and blower wheels and checks the drains and electrical connections. White vapour during defrost and a short pause in heating are part of normal operation. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 3-Zone Heat Pump ARCOAIRE D5CMHA | 24,000 BTU - R454B. We measure each bedroom, choose the size of the three heads and confirm your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797589262628,"sku":"D5CMHAH24DAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_D5CMHA_R454B_3_ZONES_2_TONNES_24000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-3-zones-arcoaire-d5cmha-24000-btu-r454b","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}