{"product_id":"thermopompe-3-zones-arcoaire-dlcmhb-30000-btu-r410a","title":"3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A","description":"\u003ch2\u003eThree zones to put the window air conditioners away and take the load off the baseboards\u003c\/h2\u003e\n\u003cp\u003eMany homes in Greater \u003cstrong\u003eMontreal\u003c\/strong\u003e live with the same compromise: an air conditioner in the living room window, another in a bedroom, and \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e everywhere for winter. The \u003cstrong\u003e3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A\u003c\/strong\u003e replaces that patchwork with three \u003cstrong\u003ewall heads\u003c\/strong\u003e that heat and cool, connected to a single \u003cstrong\u003eDLCMHBH30DAK condenser\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e2.5-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e3 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e4\u003c\/strong\u003e at most. The wall heads intended for it are the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e, the \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e and the \u003cstrong\u003eDLFSHCH18XAK\u003c\/strong\u003e. Its certified ratings are \u003cstrong\u003e22.4 SEER2\u003c\/strong\u003e, \u003cstrong\u003e12.0 EER2\u003c\/strong\u003e and \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified under \u003cstrong\u003eENERGY STAR ID 2545779\u003c\/strong\u003e and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $1,350\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe typical semi-detached: a ground floor and two bedrooms\u003c\/h3\u003e\n\u003cp\u003eThe most common configuration for this system is a semi-detached or a mid-sized two-storey house: one head for the living room and kitchen on the ground floor, one for the main bedroom, one for the second bedroom or the office. It also suits a bungalow where the living room, the bedroom and a basement room need to be handled separately.\u003c\/p\u003e\n\u003cp\u003eThe right result depends on the house. A well-insulated house with recent windows lets the three heads do most of the work. In an older house, we estimate what the heat pump can cover and what is left to the baseboards, then we write it into the quote.\u003c\/p\u003e\n\u003ch3\u003ePutting the window air conditioners away for good\u003c\/h3\u003e\n\u003cp\u003eA wall head frees the window, all year round. No more unit to put in every spring and take out every fall, no more poorly sealed opening all summer, no more blocked window that will not lock. The condenser is outside, and only a discreet flow of air remains in the room.\u003c\/p\u003e\n\u003cp\u003eYou also feel the difference in comfort. A window air conditioner cools hard, stops, then starts again; the air ends up cold and clammy at the same time. The condenser's \u003cstrong\u003einverter compressor\u003c\/strong\u003e runs for long periods at low speed, removes moisture from the air and keeps a steady temperature. For cooling, the system is built around a nominal size of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, distributed among the three rooms according to their demand.\u003c\/p\u003e\n\u003ch3\u003eThree heads, three possible sizes\u003c\/h3\u003e\n\u003cp\u003eThe three heads do not have to be identical. The \u003cstrong\u003eDLFSHCH18XAK\u003c\/strong\u003e, the largest, generally goes in the living room. The \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e suits a main bedroom or a south-facing room, and the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e a small bedroom or an office. The exact combination is decided after the on-site assessment, room by room.\u003c\/p\u003e\n\u003cp\u003eThe heads share the condenser's capacity. When they all call together, it is split between them; when only one room is occupied, it gets all the available capacity. With 3 zones out of a maximum of 4, one connection remains free: a fourth room can be added later if the remaining capacity allows it, which we check before any addition.\u003c\/p\u003e\n\u003ch3\u003eSpring and fall: the season when the heat pump pays off most\u003c\/h3\u003e\n\u003cp\u003ePeople think mostly about the deep cold, but a good part of a Quebec home's heating happens in cool weather: in October, November, March and April. At those temperatures, the heat pump does all the work, the baseboards stay off and efficiency is at its best. That is where the \u003cstrong\u003eHSPF2\u003c\/strong\u003e rating of 9.5, which measures heating efficiency over the whole season, takes on its meaning.\u003c\/p\u003e\n\u003cp\u003eOne piece of practical advice follows from this. With a heat pump, it is better to keep a steady set point in each zone than to lower it sharply at night and raise it again in the morning. The inverter compressor works more efficiently at a moderate, constant speed than when catching up, and the baseboards do not have to step in to close the gap. If a room is unoccupied for several days, simply lower its set point or shut off its zone.\u003c\/p\u003e\n\u003ch3\u003eThe January cold, backed by figures\u003c\/h3\u003e\n\u003cp\u003eThe certificate lists \u003cstrong\u003e27,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) and \u003cstrong\u003e23,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 1.65\u003c\/strong\u003e at the -15 °C point. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, the condenser delivers 77% of its nominal size, shared among the three heads. A COP of 1.65 means that each kilowatt-hour consumed still returns 1.65 kilowatt-hours of heat, where a baseboard returns one. This system is ENERGY STAR certified, but it does not carry the cold-climate designation: we therefore recommend it with the existing baseboards kept as backup for the coldest nights.\u003c\/p\u003e\n\u003cp\u003eIn cold, humid weather, the condenser runs \u003cstrong\u003edefrost cycles\u003c\/strong\u003e of a few minutes, during which the heads stop blowing warm air. The white vapour that then rises from the outdoor unit is normal.\u003c\/p\u003e\n\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 207642993\u003c\/strong\u003e, as published by ENERGY STAR.\u003c\/p\u003e\n\u003ch3\u003eWhat the condenser does differently\u003c\/h3\u003e\n\u003cp\u003eA multi-zone condenser is not three units packed into one box. It meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each head according to its demand, slows down when the set points are reached and speeds up when several rooms call. Shutting off an unoccupied zone leaves the others running normally. All the heads work in the same mode, heating or cooling; for a home that lives through the same season from one room to the next, this has no consequence.\u003c\/p\u003e\n\u003ch3\u003eThe ratings, in plain terms\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2\u003c\/strong\u003e of 22.4 measures cooling efficiency over a whole summer. The \u003cstrong\u003eEER2\u003c\/strong\u003e of 12.0 measures cooling at full load, during a heat wave. The \u003cstrong\u003eHSPF2\u003c\/strong\u003e of 9.5 measures heating over the entire cold season. Finally, the \u003cstrong\u003eCOP\u003c\/strong\u003e expresses efficiency at a specific temperature: it is the ratio between heat delivered and electricity consumed.\u003c\/p\u003e\n\u003ch3\u003eIndicative LogisVert amount: $1,350\u003c\/h3\u003e\n\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$1,350\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eThree zones installed without cluttering the facade\u003c\/h2\u003e\n\u003ch3\u003eFrom the on-site assessment to commissioning\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eVisit\u003c\/strong\u003e: we measure the three rooms and note the windows, the insulation and the electrical panel.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOn-site assessment\u003c\/strong\u003e: it confirms the condenser size and the right head for each room.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e: set above the snow line, on a wall bracket or a stand, sheltered from snow sliding off the roof.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant lines\u003c\/strong\u003e: one set per head, grouped in a line cover on the facade for a clean route.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrains\u003c\/strong\u003e: one sloped condensate drain per head.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e: a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e for the condenser, checked at the panel.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e: vacuum, leak test, check of each zone and setup of the remotes with you.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of all three heads every two weeks in season. Keep the condenser clear of snow, ice and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 3-Zone Heat Pump ARCOAIRE DLCMHB | 30,000 BTU - R410A. We assess your three rooms and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable while supplies last.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797704605988,"sku":"DLCMHBH30DAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_DLCMHB_R410A_3_ZONES_2_5_TONNES_30000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-3-zones-arcoaire-dlcmhb-30000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}