{"product_id":"thermopompe-3-zones-kinghome-ultra-heat-r32-36-000-btu-montreal-laval-rive-sud-rive-nord","title":"KINGHOME Ultra Heat R32 3-Zone Heat Pump | 36,000 BTU | Montréal, Laval, South Shore, North Shore","description":"\u003ch2\u003eThree levels, three zones, a house that needs real heating\u003c\/h2\u003e\n\u003cp\u003eOlder houses in \u003cstrong\u003eMontréal\u003c\/strong\u003e and in the first-ring suburbs of \u003cstrong\u003eLaval\u003c\/strong\u003e and \u003cstrong\u003eLongueuil\u003c\/strong\u003e often have three clearly separate levels: a main living floor, an upper floor of bedrooms and a basement finished over the years. The original insulation is modest, the windows have been replaced once, and heating relies on baseboards or an old electric furnace. In this kind of house, a heat pump isn't just there to cool in summer: it's expected to carry a real share of the winter heating. This KINGHOME Ultra Heat R32 36,000 BTU three-zone \u003cstrong\u003emulti-zone heat pump\u003c\/strong\u003e puts one head on each level, with the reserve capacity that a house losing heat calls for.\u003c\/p\u003e\n\u003cp\u003eWe also recommend it for corner houses and more isolated properties on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, which are more exposed to wind than attached houses.\u003c\/p\u003e\n\u003ch3\u003eOne head per level\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKM36X6O\u003c\/strong\u003e outdoor unit accepts the CHARMO multi-zone wall-mounted heads \u003cstrong\u003eKW09XQ19CDI\u003c\/strong\u003e (9,000 BTU), \u003cstrong\u003eKW12XQ19CDI\u003c\/strong\u003e (12,000 BTU), \u003cstrong\u003eKW18XQ19CDI\u003c\/strong\u003e (18,000 BTU) and \u003cstrong\u003eKW24XQ19CDI\u003c\/strong\u003e (24,000 BTU). For a three-level house, the layout we choose most often is the following:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround floor\u003c\/strong\u003e: an 18,000 or 24,000 BTU head, depending on how open the living area is and how much glazing it has.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpper floor\u003c\/strong\u003e: a 12,000 BTU head on the landing or in the primary bedroom, where summer heat builds up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasement\u003c\/strong\u003e: a 9,000 or 12,000 BTU head, which heats in winter and dehumidifies in summer.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWith a 24,000 BTU head on the ground floor, 12,000 BTU upstairs and 9,000 BTU in the basement, the total comes to 45,000 BTU. Going over the nominal capacity like this is common in multi-zone systems, because the three levels don't call for their maximum at the same time. The variable-speed compressor and the electronic expansion valve distribute refrigerant according to each head's demand.\u003c\/p\u003e\n\u003ch3\u003eCapacity that doesn't drop before -15 °C\u003c\/h3\u003e\n\u003cp\u003eIn a house that loses heat, what matters is the capacity delivered in deep cold. The values listed on NEEP for this combination with wall-mounted heads (AHRI No. 215708444):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e36,000 BTU\/h at -8.3 °C\u003c\/strong\u003e, COP of 2.3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36,000 BTU\/h at -15 °C\u003c\/strong\u003e, COP of 2.1: the full nominal capacity is still available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e26,200 BTU\/h at -30 °C\u003c\/strong\u003e, COP of 1.51, or nearly 73% of nominal capacity, at the heating operating limit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat's why we steer more energy-hungry houses toward this model rather than a lower-capacity three-zone unit: the difference doesn't show in October, it shows during the first week at -15 °C. The heat pump then remains the main heating source, and the electric furnace or baseboards only kick in as backup. The unit carries the \u003cstrong\u003eENERGY STAR cold climate designation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe basement, often the most cost-effective zone\u003c\/h3\u003e\n\u003cp\u003eIn an older house, the basement is cold in winter and damp in summer. Heat from the ground floor never makes it down there. A dedicated head makes it livable year-round, protects the finishes and cuts down on the use of a portable dehumidifier. We mount it high on a wall, away from the joists and existing duct bulkheads, so the airflow covers the whole room.\u003c\/p\u003e\n\u003ch3\u003eEfficiency and features\u003c\/h3\u003e\n\u003cp\u003eThe system is certified at \u003cstrong\u003e21 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10 HSPF2\u003c\/strong\u003e and \u003cstrong\u003e12 EER2\u003c\/strong\u003e. Each head offers automatic vertical and horizontal louvres, 3D airflow, humidity control, Turbo mode, self-cleaning and \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e leak detection. \u003cstrong\u003eWi-Fi is included\u003c\/strong\u003e: the three levels are adjusted separately in the KINGHOME PLUS app or by voice command. The outdoor unit is equipped with a heater in the base pan for defrost water, smart defrost and MAX Guard anti-corrosion protection.\u003c\/p\u003e\n\u003ch2\u003eWhat we check before installation\u003c\/h2\u003e\n\u003cp\u003eAn older house often holds surprises. Here are the points we confirm during an assessment in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe electrical service\u003c\/h3\u003e\n\u003cp\u003eThe system requires a \u003cstrong\u003e220 V\u003c\/strong\u003e supply, a \u003cstrong\u003e30 A MCA\u003c\/strong\u003e and a \u003cstrong\u003e45 A MOP\u003c\/strong\u003e. The three heads are powered by the outdoor unit. In an older house, this is the first thing we check: service capacity, panel condition, available space and the load of the baseboards and furnace already connected. If an upgrade is needed, we say so in the quote, not after the work is done.\u003c\/p\u003e\n\u003ch3\u003eOutdoor unit location\u003c\/h3\u003e\n\u003cp\u003eThe unit measures \u003cstrong\u003e40.16 x 16.81 x 32.52 inches\u003c\/strong\u003e and its sound level is rated at \u003cstrong\u003e63 dB(A)\u003c\/strong\u003e. On a street where houses are close together, we place it away from bedroom windows, yours as well as the neighbours'. It is mounted on a wall bracket above the snow line, sheltered from snow sliding off the roof, with free drainage for defrost water.\u003c\/p\u003e\n\u003ch3\u003eThree levels of line sets\u003c\/h3\u003e\n\u003cp\u003eEach head is connected by its own pair of \u003cstrong\u003e1\/4 and 3\/8 inch\u003c\/strong\u003e lines. The upper-floor line is the longest and the highest; the basement line goes through the foundation or the rim joist. We check the height difference between the outdoor unit and each head, group the lines in a line-set cover, and pull a vacuum and run a leak test on every circuit.\u003c\/p\u003e\n\u003ch3\u003eDrains\u003c\/h3\u003e\n\u003cp\u003eThe ground-floor and upper-floor heads usually drain outside by gravity. In the basement, we install a condensate pump connected to an existing drain.\u003c\/p\u003e\n\u003ch3\u003eCertification and LogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eReference numbers: \u003cstrong\u003eAHRI 215708444\u003c\/strong\u003e and \u003cstrong\u003eENERGY STAR ID 3798994\u003c\/strong\u003e. This combination has an \u003cstrong\u003eindicative LogisVert amount of $4,320\u003c\/strong\u003e, calculated with the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians used to older houses and their quirks.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e$5,000,000\u003c\/strong\u003e in civil liability insurance.\u003c\/li\u003e\n\u003cli\u003eWarranty registration handled by us at commissioning.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service that knows all three of your levels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate: we assess each level, check your electrical service and give you a clear quote for the whole house.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered units.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959623811364,"sku":"KM36X6O-999","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_3_ZONES_KINGHOME_ULTRA_HEAT_R32_36_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291369","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-3-zones-kinghome-ultra-heat-r32-36-000-btu-montreal-laval-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}