{"product_id":"thermopompe-4-zones-arcoaire-dlcmhb-48000-btu-r410a","title":"4-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A","description":"\u003ch2\u003eFour zones on two floors: the daytime rooms, the night-time rooms and a single condenser\u003c\/h2\u003e\n\u003cp\u003eA large house is never fully occupied at the same time. During the day, life happens on the ground floor; in the evening, everyone goes up to the bedrooms. The \u003cstrong\u003e4-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A\u003c\/strong\u003e follows that movement with four independent \u003cstrong\u003ewall heads\u003c\/strong\u003e, spread over both floors and connected to a single \u003cstrong\u003eDLCMHBH48EAK condenser\u003c\/strong\u003e that directs its capacity to the occupied rooms.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e4-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e4 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e5\u003c\/strong\u003e at most. The wall heads intended for it are the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e, the \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e and the \u003cstrong\u003eDLFSHCH24XAK\u003c\/strong\u003e. Its certified ratings are \u003cstrong\u003e21.2 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.0 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2410134\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $4,680\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDaytime zones, night-time zones\u003c\/h3\u003e\n\u003cp\u003eIn a two-storey house, two zones are used during the day: the large living space and the kitchen or dining room. Two others are used at night: the main bedroom and a second bedroom, or a bedroom and an office. With a head in each one, you set the daytime rooms for the day and the night-time rooms for sleep, without heating or cooling an empty bedroom at noon.\u003c\/p\u003e\n\u003cp\u003eThis requires no complicated programming. Each remote keeps its own set point, and the condenser distributes its capacity according to the heads that are actually calling. During the day, the daytime rooms benefit; in the evening, demand moves upstairs.\u003c\/p\u003e\n\u003ch3\u003eFor which homes\u003c\/h3\u003e\n\u003cp\u003eThis size targets large houses without \u003cstrong\u003educts\u003c\/strong\u003e: a two-storey with an open living space on the ground floor and several bedrooms upstairs, a bungalow with a finished basement, or an extended house whose parts have neither the same exposure nor the same insulation. In a well-insulated house, it replaces most of the \u003cstrong\u003eelectric baseboard\u003c\/strong\u003e heating and cools both floors in summer.\u003c\/p\u003e\n\u003cp\u003eIn an older house, we estimate the share the four heads can take on and the share left to the backup. The figure that matters is not the floor area, but the load of each room.\u003c\/p\u003e\n\u003ch3\u003eChoosing the four heads\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDLFSHCH24XAK\u003c\/strong\u003e, the largest of the intended heads, goes in the open living space. The \u003cstrong\u003eDLFSHCH12XAK\u003c\/strong\u003e suits the kitchen, the dining room or the main bedroom, and the \u003cstrong\u003eDLFSHCH09XAK\u003c\/strong\u003e the smaller bedrooms and the office. A head that is too large in a small bedroom reaches its set point too quickly and removes less moisture; a head that is too small in the living room strains without ever catching up. The on-site assessment avoids both mistakes.\u003c\/p\u003e\n\u003cp\u003eThe four heads share the condenser's capacity. When they all call at full demand, it is split between them. With 4 zones out of a maximum of 5, one connection remains free for a room added later, after checking the remaining capacity.\u003c\/p\u003e\n\u003ch3\u003eThe cold, backed by the certificate's figures\u003c\/h3\u003e\n\u003cp\u003eThe certificate lists \u003cstrong\u003e39,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F), with a \u003cstrong\u003eCOP of 2.50\u003c\/strong\u003e, and \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 2.00\u003c\/strong\u003e. The maximum published capacity is \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, the four heads therefore have 94% of the condenser's nominal size available, and each kilowatt-hour consumed returns two kilowatt-hours of heat, where a baseboard returns one. ENERGY STAR's \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e confirms that the combination meets the low-temperature performance criteria.\u003c\/p\u003e\n\u003cp\u003eThe certificate does not publish a colder point. Keep the existing baseboards as backup, set slightly below the heads' set point: they serve during extreme cold and during \u003cstrong\u003edefrost cycles\u003c\/strong\u003e, those few minutes when the condenser melts the frost off its coil and a cloud of vapour escapes from it.\u003c\/p\u003e\n\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 207642999\u003c\/strong\u003e, published by NEEP.\u003c\/p\u003e\n\u003ch3\u003eHow the compressor follows the house\u003c\/h3\u003e\n\u003cp\u003eThe condenser's \u003cstrong\u003einverter compressor\u003c\/strong\u003e does not run on an on-off cycle. It speeds up when several heads call, slows down when the set points are reached, and meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each head according to its demand. When the family moves from the daytime rooms to the bedrooms, the condenser follows, smoothly.\u003c\/p\u003e\n\u003cp\u003eAs on any multi-zone system of this type, the four heads work in the same mode: all heating or all cooling. Shutting off an unoccupied zone, a guest room for example, leaves the other three running normally.\u003c\/p\u003e\n\u003ch3\u003eSummer upstairs and on the ground floor\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the system is built around a nominal size of \u003cstrong\u003e48,000 BTU\/h\u003c\/strong\u003e for the four zones. In the afternoon, the living space and kitchen ask the most; in the evening, it is the upstairs bedrooms, heated by the roof all day. Extended low-speed operation removes moisture from the air, and each head offers a dehumidification mode for muggy days.\u003c\/p\u003e\n\u003ch3\u003eThe ratings, one by one\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHSPF2\u003c\/strong\u003e of 10.0 measures heating efficiency over the whole cold season; for a large house heated largely by heat pump, it is the rating that weighs most. The \u003cstrong\u003eSEER2\u003c\/strong\u003e of 21.2 measures cooling efficiency over a whole summer. The \u003cstrong\u003eEER2\u003c\/strong\u003e of 11.0 measures cooling at full load, in hot weather. The \u003cstrong\u003eCOP\u003c\/strong\u003e expresses efficiency at a specific temperature: 2.50 at -8 °C and 2.00 at -15 °C.\u003c\/p\u003e\n\u003ch3\u003eIndicative LogisVert amount: $4,680\u003c\/h3\u003e\n\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$4,680\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eAn installation planned over two floors\u003c\/h2\u003e\n\u003ch3\u003eLines, drains and electrical\u003c\/h3\u003e\n\u003cp\u003eFour heads means four \u003cstrong\u003erefrigerant line sets\u003c\/strong\u003e, all running back to the same condenser. We place it where the routes are shortest, above the snow line, on a stand or a sturdy bracket, sheltered from snow sliding off the roof. The lines for the upstairs heads run up a painted line cover along the facade, or go indoors when a closet or the attic allows it. We show you each route before drilling.\u003c\/p\u003e\n\u003cp\u003eEach head has its own condensate \u003cstrong\u003edrain\u003c\/strong\u003e, sloped toward the outside; a condensate pump is only planned where gravity is not enough. The 4-ton condenser is connected to a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, and we check the panel's space and capacity during the visit. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the four remotes with you.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of all four heads every two weeks in season, preferably on the same day. Keep the condenser clear of snow and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains and checks the electrical connections. On a system where every zone depends on the same condenser, this visit reduces the risk of a shutdown in the middle of winter. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 4-Zone Heat Pump ARCOAIRE DLCMHB | 48,000 BTU - R410A. We assess both floors room by room and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable while supplies last.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797737341220,"sku":"DLCMHBH48EAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_ARCOAIRE_DLCMHB_R410A_4_ZONES_4_TONNES_48000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082560","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-4-zones-arcoaire-dlcmhb-48000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}