{"product_id":"thermopompe-4-zones-conforto-mhmz-48000-btu-r410a","title":"4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A","description":"\u003ch2\u003eFour zones on three levels: basement, ground floor and upper floor, a single 4-ton condenser\u003c\/h2\u003e\n\u003cp\u003eIn a three-level house, each floor has its own climate. The basement stays cool and damp, the ground floor loses its heat through large windows, and the upper floor receives all the warm air rising up the staircase. The \u003cstrong\u003e4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A\u003c\/strong\u003e spreads four \u003cstrong\u003ewall heads\u003c\/strong\u003e over these three levels and connects them to a single \u003cstrong\u003eMHMZ548DACFC condenser\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003e4-ton\u003c\/strong\u003e condenser serves \u003cstrong\u003e4 zones\u003c\/strong\u003e here and accepts up to \u003cstrong\u003e5\u003c\/strong\u003e at most. Its AHRI certificate was established with the \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e, \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e and \u003cstrong\u003eMHWAL24DACFC\u003c\/strong\u003e wall heads; your heads are chosen with you during the visit. Its certified ratings are \u003cstrong\u003e21.8 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.7 EER2\u003c\/strong\u003e and \u003cstrong\u003e9.8 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2495078\u003c\/strong\u003e, and its indicative LogisVert amount is $4,320 (only Hydro-Québec confirms the amount granted).\u003c\/p\u003e\n\u003ch3\u003eThree levels, three climates\u003c\/h3\u003e\n\u003cp\u003eIn winter, heat from the ground floor rises to the upper floor, which becomes the warmest level, while the basement stays cold at floor level. In summer, it is the reverse: the upper floor overheats under the roof and the basement, cool but damp, mostly needs to be dried out. A single unit, set to a single set point, cannot satisfy all three levels at once.\u003c\/p\u003e\n\u003cp\u003eWith heads spread over the three levels, each floor is set according to its use: a basement kept a little cooler when it is empty, a bedroom cooler for sleeping, a living space comfortable in the evening. This avoids the classic single-thermostat situation, where the upper floor gets too hot because the set point was raised to warm the basement.\u003c\/p\u003e\n\u003cp\u003eThis size targets a large two-storey house with a finished basement, or a two-storey whose basement serves as a family room. The result depends on the envelope: in a well-insulated house, the four heads carry most of the heating and all of the cooling. In an older house, we assess on site the share left to the \u003cstrong\u003eelectric baseboards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the four heads are distributed\u003c\/h3\u003e\n\u003cp\u003eOn the ground floor, the largest head usually serves the living space. Upstairs, the main bedroom gets the \u003cstrong\u003eMHWAL12DACFC\u003c\/strong\u003e and a second bedroom the \u003cstrong\u003eMHWAL09DACFC\u003c\/strong\u003e. In the basement, the choice depends on the floor area and the insulation of the foundation walls: the MHWAL12DACFC for a mid-sized family room, the MHWAL24DACFC for a large open basement. The on-site assessment decides.\u003c\/p\u003e\n\u003cp\u003eThe four heads share the condenser's capacity. When they all call at full demand, it is split between them; the rest of the time, the occupied levels benefit from the capacity the others are not using. With 4 zones out of a maximum of 5, one connection remains free for a room added later, after checking the remaining capacity.\u003c\/p\u003e\n\u003ch3\u003eThe electrical panel first\u003c\/h3\u003e\n\u003cp\u003eA 4-ton condenser requires a larger \u003cstrong\u003ededicated circuit\u003c\/strong\u003e than a small wall-mounted heat pump. During the visit, we open the panel: available space, capacity of the electrical service, loads already connected such as a range, a dryer or a water heater. In a house whose panel is already heavily loaded, an upgrade may be needed; we point it out during the visit, and that work appears in the written quote just like the unit.\u003c\/p\u003e\n\u003ch3\u003eWhat the NEEP list shows\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives \u003cstrong\u003e36,000 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F), with a \u003cstrong\u003eCOP of 2.30\u003c\/strong\u003e, and \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 2.00\u003c\/strong\u003e. The maximum published capacity is \u003cstrong\u003e45,000 BTU\/h at -15 °C\u003c\/strong\u003e. The two points are measured separately; we report each one as published.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, the four heads therefore share the 45,000 BTU\/h listed by NEEP, and each kilowatt-hour consumed returns two kilowatt-hours of heat, where an electric baseboard returns one. ENERGY STAR's \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e confirms that the combination meets the low-temperature performance criteria.\u003c\/p\u003e\n\u003cp\u003eThese figures come from NEEP's cold-climate heat pump list, for certificate \u003cstrong\u003eAHRI 210605819\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eBackup heat and defrost\u003c\/h3\u003e\n\u003cp\u003eThe NEEP list gives no point colder than -15 °C. We therefore recommend keeping the existing baseboards, set slightly below the heads' set point: they stay off for most of the winter and take over during extreme cold. In cold, humid weather, the condenser also runs \u003cstrong\u003edefrost cycles\u003c\/strong\u003e of a few minutes; the heads then stop blowing warm air and a cloud of vapour rises from the outdoor unit. This is normal.\u003c\/p\u003e\n\u003ch3\u003eThe inverter compressor from one level to the next\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003einverter compressor\u003c\/strong\u003e varies its speed according to the demand of the four heads and meters the \u003cstrong\u003eR-410A refrigerant\u003c\/strong\u003e sent to each one. In winter, the upstairs head often slows down on its own, benefiting from the rising heat, while the basement head works harder. The four heads always work in the same mode, heating or cooling, as on any multi-zone system of this type. Shutting off an unoccupied zone leaves the other three running normally.\u003c\/p\u003e\n\u003ch3\u003eSummer: the upper floor for heat, the basement for humidity\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the system is built around a nominal size of \u003cstrong\u003e48,000 BTU\/h\u003c\/strong\u003e for the four zones. The upstairs heads carry most of the effort on hot evenings. In the basement, dehumidification mode removes the damp air without needlessly cooling the room. Everywhere, extended low-speed operation makes the air drier and more comfortable.\u003c\/p\u003e\n\u003ch3\u003eThe certified ratings, in plain terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e9.8 HSPF2\u003c\/strong\u003e: heating efficiency over the whole cold season, calculated for a reference climate (region IV); it is used to compare models.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e21.8 SEER2\u003c\/strong\u003e: cooling efficiency over a whole summer.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e11.7 EER2\u003c\/strong\u003e: cooling at full load, in hot weather.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e: the ratio between heat delivered and electricity consumed at a specific temperature, here 2.30 at -8 °C and 2.00 at -15 °C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe indicative LogisVert amount: $4,320\u003c\/h3\u003e\n\u003cp\u003eThe system is listed in Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program, with an indicative amount of \u003cstrong\u003e$4,320\u003c\/strong\u003e for the owner of an existing home, according to the list in effect on the installation date. Only Hydro-Québec confirms the amount granted. We check eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\n\u003ch2\u003eAn installation over three levels\u003c\/h2\u003e\n\u003ch3\u003eLines, drains and commissioning\u003c\/h3\u003e\n\u003cp\u003eThe condenser is installed where the four line routes are shortest, above the snow line, on a stand or a sturdy bracket, away from snow sliding off the roof. Each head gets its own \u003cstrong\u003erefrigerant line set\u003c\/strong\u003e: the basement one goes through the foundation wall, the upstairs ones run up the facade in a painted line cover. We show you each route before drilling.\u003c\/p\u003e\n\u003cp\u003eEach head also has its own sloped condensate \u003cstrong\u003edrain\u003c\/strong\u003e. In the basement, a small condensate pump often becomes necessary for lack of a natural slope; we determine that during the visit. Commissioning includes the vacuum, the leak test, a check of each zone and setup of the four remotes with you.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eRinse the filters of all four heads every two weeks in season, preferably on the same day. Keep the condenser clear of snow and leaves, without covering it in winter. One \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance visit per year cleans the coils, fans and drains, checks the condensate pump if there is one and inspects the electrical connections. Our \u003ca href=\"\/en\/pages\/services-de-nettoyage-climatiseurs-et-thermopompes-murales-grand-montreal\"\u003ecleaning service\u003c\/a\u003e takes over when you prefer to hand off the annual visit.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, the company behind the installation\u003c\/h3\u003e\n\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 4-Zone Heat Pump CONFORTO MHMZ | 48,000 BTU - R410A. We assess your three levels and your electrical panel and confirm the right size and check your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Conforto","offers":[{"title":"Default Title","offer_id":67797783773476,"sku":"MHMZ548DACFC","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MULTIZONE_CONFORTO_MAXIMUM_MHMZ_R410A_4_ZONES_4_TONNES_48000_BTU_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082570","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-4-zones-conforto-mhmz-48000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}