{"product_id":"thermopompe-4-zones-kinghome-ultra-heat-r32-36-000-btu-montreal-laval-rive-sud-rive-nord","title":"KINGHOME Ultra Heat R32 4-Zone Heat Pump | 36,000 BTU | Montréal, Laval, South Shore, North Shore","description":"\u003ch2\u003eA complete zoning plan for a single-family house\u003c\/h2\u003e\n\u003cp\u003eWhen a homeowner asks us to do the whole house without installing ductwork, the project changes scale. It's no longer about adding comfort to one difficult room, but about building a complete plan: which room gets a head, what size, and how a single outdoor unit shares its capacity among all those spaces. This 36,000 BTU, four-zone KINGHOME Ultra Heat R32 \u003cstrong\u003emulti-zone heat pump\u003c\/strong\u003e is the tool for that kind of project: four wall-mounted heads, one of which can be a large one, connected to an outdoor unit that keeps its full nominal capacity down to -15 °C.\u003c\/p\u003e\n\u003cp\u003eWe install it in single-family houses in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e that combine an open area, closed bedrooms and a finished basement, and in large houses in \u003cstrong\u003eMontréal\u003c\/strong\u003e where the owner wants to replace both the baseboards and the window air conditioners.\u003c\/p\u003e\n\u003ch3\u003eBuilding the capacity budget\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKM36X6O\u003c\/strong\u003e outdoor unit accepts the CHARMO multi-zone wall-mounted heads \u003cstrong\u003eKW09XQ19CDI\u003c\/strong\u003e (9,000 BTU), \u003cstrong\u003eKW12XQ19CDI\u003c\/strong\u003e (12,000 BTU), \u003cstrong\u003eKW18XQ19CDI\u003c\/strong\u003e (18,000 BTU) and \u003cstrong\u003eKW24XQ19CDI\u003c\/strong\u003e (24,000 BTU). With four zones, the choice of each head comes from an on-site assessment of heating needs, room by room, not from a general rule. A common example:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen area on the main floor\u003c\/strong\u003e: an 18,000 BTU head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain bedroom\u003c\/strong\u003e: a 12,000 BTU head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecond bedroom\u003c\/strong\u003e: a 9,000 BTU head.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinished basement\u003c\/strong\u003e: a 9,000 BTU head.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe total, 48,000 BTU, is higher than the outdoor unit's nominal capacity of 36,000 BTU. That's how a well-designed multi-zone system works: the four zones never all call for their maximum at the same time. At night, the open area and the basement run at low speed while the bedrooms are active; during the day, it's the reverse. The variable-speed compressor and the electronic expansion valve adjust the refrigerant flow to each head's actual demand.\u003c\/p\u003e\n\u003ch3\u003eFour zones is this unit's maximum\u003c\/h3\u003e\n\u003cp\u003eThe KM36X6O can serve four zones at most. In this version, every connection is used: there won't be a fifth head added later on the same unit. So the plan has to be right from the start. During our visit, we go over every room with you, including the ones that won't get a head and how they'll be served, through an open door to a neighbouring zone or by the baseboard that stays in place.\u003c\/p\u003e\n\u003ch3\u003eCold-weather performance that lets you heat the whole house\u003c\/h3\u003e\n\u003cp\u003eFor a heat pump that serves an entire house, the key number is the capacity delivered in the dead of winter. According to the values listed on NEEP (AHRI No. 215708444) for this combination with wall-mounted heads:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: \u003cstrong\u003e36,000 BTU\/h\u003c\/strong\u003e, with a COP of 2.3.\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e36,000 BTU\/h\u003c\/strong\u003e, with a COP of 2.1, or 100% of the nominal capacity.\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: \u003cstrong\u003e26,200 BTU\/h\u003c\/strong\u003e, with a COP of 1.51, at the heating operating limit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA COP of 2.1 at -15 °C means the house gets a little more than twice the heat for every kilowatt-hour used, compared with baseboards. Over a full winter, that's where most of the savings come from. The baseboards stay in place as backup, room by room, for the coldest hours. The unit carries the \u003cstrong\u003eENERGY STAR cold climate designation\u003c\/strong\u003e and is rated at \u003cstrong\u003e21 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10 HSPF2\u003c\/strong\u003e and \u003cstrong\u003e12 EER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eA whole house controlled from your phone\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWi-Fi is included\u003c\/strong\u003e. All four zones show up in the KINGHOME PLUS app: you can schedule each one according to how it's used, shut off the basement when no one's down there and get the house ready before you come back from a trip. Each head keeps its own remote, and voice control works with Google Assistant and Amazon Alexa. Automatic vertical and horizontal louvres, 3D airflow, humidity control, self-cleaning and \u003cstrong\u003eR-32 refrigerant\u003c\/strong\u003e leak detection come on every head.\u003c\/p\u003e\n\u003ch2\u003eWhat we check before the installation\u003c\/h2\u003e\n\u003cp\u003eA four-zone system on a 36,000 BTU unit is a primary heating project. Here's what we confirm during an assessment in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe electrical supply\u003c\/h3\u003e\n\u003cp\u003eThe unit requires \u003cstrong\u003e220 V\u003c\/strong\u003e, an \u003cstrong\u003eMCA of 30 A\u003c\/strong\u003e and an \u003cstrong\u003eMOP of 45 A\u003c\/strong\u003e. All four heads are powered by the outdoor unit. We review the electrical service and the panel, taking into account the baseboards, the water heater and the appliances already connected. One circuit for four zones is still much simpler than four separate units, but that circuit has to be planned properly.\u003c\/p\u003e\n\u003ch3\u003eWhere the outdoor unit goes\u003c\/h3\u003e\n\u003cp\u003eThe unit measures \u003cstrong\u003e40.16 x 16.81 x 32.52 inches\u003c\/strong\u003e and its sound level is rated at \u003cstrong\u003e63 dB(A)\u003c\/strong\u003e. For a unit that runs much of the winter, we choose a wall away from the bedrooms and from the neighbour's property line, and a spot where the four sets of lines come together without crossing the whole exterior wall. Wall bracket anchored into the structure, above the snow, out of the way of snow falling off the roof.\u003c\/p\u003e\n\u003ch3\u003eFour piping circuits\u003c\/h3\u003e\n\u003cp\u003eEach head is connected by its own pair of \u003cstrong\u003e1\/4 and 3\/8 inch\u003c\/strong\u003e lines. We label each line at the outdoor unit, group the routes through the basement or in a shared line cover, insulate each line along its entire length, and do the vacuum and leak test on all four circuits. At start-up, we test each zone separately to confirm that each connection serves the right room.\u003c\/p\u003e\n\u003ch3\u003eFour drains\u003c\/h3\u003e\n\u003cp\u003eEach head has its own drain, with a continuous slope to the outside. For the basement head and for any head on an interior wall, we install a condensate pump connected to a standpipe.\u003c\/p\u003e\n\u003ch3\u003eCertification and LogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eReference numbers: \u003cstrong\u003eAHRI 215708444\u003c\/strong\u003e and \u003cstrong\u003eENERGY STAR ID 3798994\u003c\/strong\u003e. The \u003cstrong\u003eindicative LogisVert amount\u003c\/strong\u003e for this combination is \u003cstrong\u003e$4,320\u003c\/strong\u003e, calculated using the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians who draw up the zoning plan before quoting a price.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration done by our team.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service that keeps your four-zone configuration on file.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we draw up the zoning plan for your house, check your electrical service and give you a complete quote.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959623844132,"sku":"KM36X6O-9999","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_4_ZONES_KINGHOME_ULTRA_HEAT_R32_36_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291369","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-4-zones-kinghome-ultra-heat-r32-36-000-btu-montreal-laval-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}