{"product_id":"thermopompe-cassette-1-voie-gree-crossover-r32-9000-btu","title":"GREE CROSSOVER R32 1-Way Cassette Heat Pump | 9000 BTU","description":"\u003ch2 data-start=\"80\" data-end=\"159\"\u003e A discreet and controlled HVAC solution for demanding projects in Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"161\" data-end=\"615\"\u003e In \u003cstrong data-start=\"178\" data-end=\"194\"\u003eresidential\u003c\/strong\u003e , \u003cstrong data-start=\"196\" data-end=\"211\"\u003ecommercial\u003c\/strong\u003e and \u003cstrong data-start=\"215\" data-end=\"234\"\u003emulti-unit\u003c\/strong\u003e projects in \u003cstrong data-start=\"246\" data-end=\"258\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"260\" data-end=\"269\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"271\" data-end=\"284\"\u003eLongueuil\u003c\/strong\u003e , on the \u003cstrong data-start=\"293\" data-end=\"306\"\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"313\" data-end=\"325\"\u003eSouth Shore\u003c\/strong\u003e , one constraint constantly arises: how to ensure precise thermal comfort without compromising aesthetics, acoustics or air circulation? The \u003cstrong data-start=\"485\" data-end=\"548\"\u003eGREE CROSSOVER R32 9,000 BTU 1-way cassette heat pump\u003c\/strong\u003e was designed specifically to address this type of problem.\u003c\/p\u003e\n\n \u003cp data-start=\"617\" data-end=\"1090\"\u003eAt AirGreen, we integrate this ceiling cassette into a wide variety of settings: modern condos with clean lines, professional offices, commercial spaces, consultation rooms, and high-end rental units. In each of these environments, the objective is the same: to offer a \u003cstrong data-start=\"914\" data-end=\"974\"\u003ereliable, discreet, and perfectly controlled HVAC solution\u003c\/strong\u003e capable of operating efficiently in both cooling and heating, even during Quebec's harsh winters.\u003c\/p\u003e\n\n\u003ch2 data-start=\"1092\" data-end=\"1158\"\u003e A design conceived for the directional diffusion of air\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1160\" data-end=\"1227\"\u003e Why a single-channel cassette changes the comfort experience\u003c\/h3\u003e\n\n \u003cp data-start=\"1229\" data-end=\"1551\"\u003eThe key feature of this model lies in its \u003cstrong data-start=\"1287\" data-end=\"1324\"\u003eunidirectional air diffusion\u003c\/strong\u003e . Unlike 4-way cassettes, which disperse air radially, the 1-way cassette allows for \u003cstrong data-start=\"1435\" data-end=\"1472\"\u003eprecise airflow direction\u003c\/strong\u003e towards the area to be treated. This approach offers several tangible advantages: \u003c\/p\u003e\n\n\u003cul data-start=\"1553\" data-end=\"1790\"\u003e\n\n\u003cli data-start=\"1553\" data-end=\"1633\"\u003e\n\n\u003cp data-start=\"1555\" data-end=\"1633\"\u003e Significant reduction in \u003cstrong data-start=\"1577\" data-end=\"1603\"\u003edirect drafts\u003c\/strong\u003e felt by occupants \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1634\" data-end=\"1715\"\u003e\n\n\u003cp data-start=\"1636\" data-end=\"1715\"\u003e Improved temperature uniformity in elongated or open rooms \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1716\" data-end=\"1790\"\u003e\n\n\u003cp data-start=\"1718\" data-end=\"1790\"\u003e Finer control of airflow, particularly in heating mode\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"1792\" data-end=\"2054\"\u003eIn several installations carried out by AirGreen in \u003cstrong data-start=\"1846\" data-end=\"1858\"\u003eMontreal\u003c\/strong\u003e and \u003cstrong data-start=\"1862\" data-end=\"1871\"\u003eLaval\u003c\/strong\u003e , this feature made it possible to correct persistent cold zone problems observed with old wall or central systems poorly adapted to the configuration of the premises.\u003c\/p\u003e\n\n\u003ch3 data-start=\"2056\" data-end=\"2106\"\u003e A discreet format suitable for modern ceilings\u003c\/h3\u003e\n\n\u003cp data-start=\"2108\" data-end=\"2465\"\u003e With its \u003cstrong data-start=\"2117\" data-end=\"2135\"\u003ecompact design\u003c\/strong\u003e and shallow depth, the interior cassette integrates easily into suspended ceilings, even when space is limited by the building structure or the presence of other mechanical services. Once installed, only the grid is visible, preserving the interior architecture without any visual compromise.\u003c\/p\u003e\n\n \u003cp data-start=\"2467\" data-end=\"2672\"\u003eIn renovation projects carried out on the \u003cstrong data-start=\"2514\" data-end=\"2526\"\u003eSouth Shore\u003c\/strong\u003e , this criterion proved decisive for clients wishing to modernize their air conditioning system without adding visible wall elements.\u003c\/p\u003e\n\n\u003ch2 data-start=\"2674\" data-end=\"2730\"\u003e Energy efficiency and adaptation to cold climates\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2732\" data-end=\"2780\"\u003e Performance designed for Quebec winters\u003c\/h3\u003e\n\n\u003cp data-start=\"2782\" data-end=\"3046\"\u003e The \u003cstrong data-start=\"2785\" data-end=\"2829\"\u003eGREE CROSSOVER R32 9000 BTU heat pump\u003c\/strong\u003e is designed to maintain \u003cstrong data-start=\"2860\" data-end=\"2907\"\u003estable heating capacity down to -30°C\u003c\/strong\u003e , a crucial element for buildings located in \u003cstrong data-start=\"2956\" data-end=\"2969\"\u003eLongueuil\u003c\/strong\u003e , on the \u003cstrong data-start=\"2978\" data-end=\"2991\"\u003eNorth Shore\u003c\/strong\u003e or in areas more exposed to wind and cold.\u003c\/p\u003e\n\n\u003cp data-start=\"3048\" data-end=\"3105\"\u003e Its high energy efficiency translates into: \u003c\/p\u003e\n\n\u003cul data-start=\"3106\" data-end=\"3287\"\u003e\n\n\u003cli data-start=\"3106\" data-end=\"3151\"\u003e\n\n\u003cp data-start=\"3108\" data-end=\"3151\"\u003e \u003cstrong data-start=\"3112\" data-end=\"3149\"\u003eOptimized electricity consumption\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3152\" data-end=\"3212\"\u003e\n\n \u003cp data-start=\"3154\" data-end=\"3212\"\u003eA reduction in operating costs over the long term \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3213\" data-end=\"3287\"\u003e\n\n\u003cp data-start=\"3215\" data-end=\"3287\"\u003e Appreciable thermal stability during periods of extreme cold.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3289\" data-end=\"3481\"\u003e In multi-unit dwellings where AirGreen has installed this model, owners have noticed a decrease in calls related to winter discomfort compared to their old systems.\u003c\/p\u003e\n\n\u003ch3 data-start=\"3483\" data-end=\"3551\"\u003e R-32 refrigerant: efficiency and environmental responsibility\u003c\/h3\u003e\n\n\u003cp data-start=\"3553\" data-end=\"3858\"\u003e The choice of \u003cstrong data-start=\"3565\" data-end=\"3573\"\u003eR-32\u003c\/strong\u003e is part of a strategy of continuous performance improvement while reducing environmental impact. This refrigerant allows for better heat transfer, a lower charge, and increased efficiency, while meeting current and future regulatory requirements.\u003c\/p\u003e\n\n\u003ch2 data-start=\"3860\" data-end=\"3913\"\u003e Essential technical specifications to know\u003c\/h2\u003e\n\n\u003ch3 data-start=\"3915\" data-end=\"3943\"\u003e System configuration \u003c\/h3\u003e\n\n\u003cul data-start=\"3945\" data-end=\"4192\"\u003e\n\n\u003cli data-start=\"3945\" data-end=\"3991\"\u003e\n\n\u003cp data-start=\"3947\" data-end=\"3991\"\u003e \u003cstrong data-start=\"3947\" data-end=\"3967\"\u003eIndoor unit\u003c\/strong\u003e : GKH(09)DA-D6DNA1B\/I\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3992\" data-end=\"4039\"\u003e\n\n \u003cp data-start=\"3994\" data-end=\"4039\"\u003e\u003cstrong data-start=\"3994\" data-end=\"4014\"\u003eOutdoor unit\u003c\/strong\u003e : GWH09AGCXD-D6DNA4D\/O \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4040\" data-end=\"4077\"\u003e\n\n\u003cp data-start=\"4042\" data-end=\"4077\"\u003e \u003cstrong data-start=\"4042\" data-end=\"4063\"\u003eRated capacity\u003c\/strong\u003e : 9,000 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4078\" data-end=\"4101\"\u003e\n\n\u003cp data-start=\"4080\" data-end=\"4101\"\u003e \u003cstrong data-start=\"4080\" data-end=\"4091\"\u003eVoltage\u003c\/strong\u003e : 220 V \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4102\" data-end=\"4151\"\u003e\n\n\u003cp data-start=\"4104\" data-end=\"4151\"\u003e \u003cstrong data-start=\"4104\" data-end=\"4142\"\u003eMinimum circuit ampacity (MCA)\u003c\/strong\u003e : 10 A \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4152\" data-end=\"4192\"\u003e\n\n\u003cp data-start=\"4154\" data-end=\"4192\"\u003e \u003cstrong data-start=\"4154\" data-end=\"4183\"\u003eMaximum protection (MOP)\u003c\/strong\u003e : 15 A\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4194\" data-end=\"4342\"\u003e These parameters allow for relatively simple integration into the majority of standard residential and commercial installations in Quebec.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4344\" data-end=\"4375\"\u003e Controlled acoustic comfort\u003c\/h3\u003e\n\n\u003cp data-start=\"4377\" data-end=\"4478\"\u003e The \u003cstrong data-start=\"4380\" data-end=\"4416\"\u003every low interior noise level\u003c\/strong\u003e is a major advantage. In environments such as: \u003c\/p\u003e\n\n\u003cul data-start=\"4479\" data-end=\"4568\"\u003e\n\n\u003cli data-start=\"4479\" data-end=\"4501\"\u003e\n\n\u003cp data-start=\"4481\" data-end=\"4501\"\u003e Bedrooms \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4502\" data-end=\"4520\"\u003e\n\n\u003cp data-start=\"4504\" data-end=\"4520\"\u003e Offices closed \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4521\" data-end=\"4568\"\u003e\n\n\u003cp data-start=\"4523\" data-end=\"4568\"\u003e Professional spaces requiring quiet\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"4570\" data-end=\"4766\"\u003eThis model has established itself as a reliable and comfortable solution. Outside, the noise level remains compatible with the urban constraints of \u003cstrong data-start=\"4719\" data-end=\"4731\"\u003eMontreal\u003c\/strong\u003e and surrounding municipalities.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4768\" data-end=\"4813\"\u003e Humidity management and air quality\u003c\/h3\u003e\n\n\u003cp data-start=\"4815\" data-end=\"5077\"\u003e The \u003cstrong data-start=\"4818\" data-end=\"4851\"\u003edehumidification capacity\u003c\/strong\u003e helps improve perceived comfort during the summer months. Several customers on the \u003cstrong data-start=\"4937\" data-end=\"4950\"\u003eNorth Shore\u003c\/strong\u003e have noted a more consistent feeling of coolness, even on very humid days, without the need to over-cool the space.\u003c\/p\u003e\n\n\u003ch2 data-start=\"5079\" data-end=\"5136\"\u003e HVAC installation: key elements assessed by AirGreen\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5138\" data-end=\"5171\"\u003e Preliminary analysis of the building\u003c\/h3\u003e\n\n\u003cp data-start=\"5173\" data-end=\"5221\"\u003e Before any installation, our teams assess: \u003c\/p\u003e\n\n\u003cul data-start=\"5222\" data-end=\"5432\"\u003e\n\n\u003cli data-start=\"5222\" data-end=\"5261\"\u003e\n\n\u003cp data-start=\"5224\" data-end=\"5261\"\u003e The exact configuration of the room \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5262\" data-end=\"5303\"\u003e\n\n\u003cp data-start=\"5264\" data-end=\"5303\"\u003e The height and structure of the ceiling \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5304\" data-end=\"5362\"\u003e\n\n\u003cp data-start=\"5306\" data-end=\"5362\"\u003e The optimal location for directional diffusion \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5363\" data-end=\"5432\"\u003e\n\n\u003cp data-start=\"5365\" data-end=\"5432\"\u003e The routing of the piping and condensate drainage\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"5434\" data-end=\"5574\"\u003eThis approach helps avoid common mistakes, such as improper cassette orientation or poor air distribution.\u003c\/p\u003e\n\n\u003ch3 data-start=\"5576\" data-end=\"5611\"\u003e Condensate pump and safety\u003c\/h3\u003e\n\n\u003cp data-start=\"5613\" data-end=\"5859\"\u003e The cassette is equipped with an \u003cstrong data-start=\"5643\" data-end=\"5688\"\u003einternal condensate drain pump\u003c\/strong\u003e with a float switch. This device is essential in multi-story buildings or commercial spaces, where a leak could cause significant damage.\u003c\/p\u003e\n\n\u003ch3 data-start=\"5861\" data-end=\"5884\"\u003e Control options\u003c\/h3\u003e\n\n\u003cp data-start=\"5886\" data-end=\"5921\"\u003e The system can be used with: \u003c\/p\u003e\n\n\u003cul data-start=\"5922\" data-end=\"6106\"\u003e\n\n\u003cli data-start=\"5922\" data-end=\"5955\"\u003e\n\n\u003cp data-start=\"5924\" data-end=\"5955\"\u003e A \u003cstrong data-start=\"5928\" data-end=\"5953\"\u003ewireless remote control\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5956\" data-end=\"6036\"\u003e\n\n\u003cp data-start=\"5958\" data-end=\"6036\"\u003e A \u003cstrong data-start=\"5961\" data-end=\"5983\"\u003ewired thermostat\u003c\/strong\u003e , often preferred in commercial buildings \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6037\" data-end=\"6106\"\u003e\n\n\u003cp data-start=\"6039\" data-end=\"6106\"\u003e A \u003cstrong data-start=\"6050\" data-end=\"6059\"\u003eWi-Fi\u003c\/strong\u003e option, when remote management is desired\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6108\" data-end=\"6218\"\u003e AirGreen recommends the type of control best suited to the actual use of the building and the profile of the occupants.\u003c\/p\u003e\n\n \u003ch2 data-start=\"6220\" data-end=\"6272\"\u003eConcrete feedback from AirGreen installations\u003c\/h2\u003e\n\n\u003cp data-start=\"6274\" data-end=\"6483\"\u003e In several recent projects in \u003cstrong data-start=\"6307\" data-end=\"6323\"\u003eMontreal East\u003c\/strong\u003e , \u003cstrong data-start=\"6325\" data-end=\"6334\"\u003eLaval\u003c\/strong\u003e , and \u003cstrong data-start=\"6338\" data-end=\"6354\"\u003eBoucherville\u003c\/strong\u003e , this heat pump has replaced wall-mounted systems deemed noisy or visually intrusive. Observed benefits include: \u003c\/p\u003e\n\n\u003cul data-start=\"6484\" data-end=\"6616\"\u003e\n\n\u003cli data-start=\"6484\" data-end=\"6521\"\u003e\n\n\u003cp data-start=\"6486\" data-end=\"6521\"\u003e Improved thermal stability \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6522\" data-end=\"6564\"\u003e\n\n\u003cp data-start=\"6524\" data-end=\"6564\"\u003e A noticeable reduction in ambient noise \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6565\" data-end=\"6616\"\u003e\n\n\u003cp data-start=\"6567\" data-end=\"6616\"\u003e A significantly superior aesthetic integration\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6618\" data-end=\"6885\"\u003e An often underestimated factor is the \u003cstrong data-start=\"6656\" data-end=\"6689\"\u003equality of air distribution\u003c\/strong\u003e . When poorly designed, even a high-performing system can cause discomfort. The single-way cassette allows for precise adjustment of this distribution, which makes all the difference in everyday use.\u003c\/p\u003e\n\n\u003ch2 data-start=\"6887\" data-end=\"6917\"\u003e Common mistakes to avoid \u003c\/h2\u003e\n\n\u003cul data-start=\"6919\" data-end=\"7152\"\u003e\n\n\u003cli data-start=\"6919\" data-end=\"6976\"\u003e\n\n\u003cp data-start=\"6921\" data-end=\"6976\"\u003e Choosing the power without detailed thermal analysis \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6977\" data-end=\"7027\"\u003e\n\n\u003cp data-start=\"6979\" data-end=\"7027\"\u003e Neglecting the available ceiling height\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7028\" data-end=\"7106\"\u003e\n\n \u003cp data-start=\"7030\" data-end=\"7106\"\u003eInstalling the cassette without taking into account the actual geometry of the room \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7107\" data-end=\"7152\"\u003e\n\n\u003cp data-start=\"7109\" data-end=\"7152\"\u003e Underestimating the importance of acoustics\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7154\" data-end=\"7278\"\u003e These errors can compromise performance and comfort. AirGreen's methodical approach is specifically designed to avoid them.\u003c\/p\u003e\n\n\u003ch2 data-start=\"7280\" data-end=\"7320\"\u003e Why entrust this project to AirGreen? \u003c\/h2\u003e\n\n\u003cul data-start=\"7322\" data-end=\"7619\"\u003e\n\n\u003cli data-start=\"7322\" data-end=\"7387\"\u003e\n\n\u003cp data-start=\"7324\" data-end=\"7387\"\u003e \u003cstrong data-start=\"7324\" data-end=\"7358\"\u003eExtensive field experience\u003c\/strong\u003e in embedded HVAC systems \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7388\" data-end=\"7496\"\u003e\n\n\u003cp data-start=\"7390\" data-end=\"7496\"\u003e Mastery of the specific constraints of \u003cstrong data-start=\"7425\" data-end=\"7437\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"7439\" data-end=\"7448\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"7450\" data-end=\"7463\"\u003eLongueuil\u003c\/strong\u003e , \u003cstrong data-start=\"7465\" data-end=\"7478\"\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong data-start=\"7482\" data-end=\"7494\"\u003eSouth Shore\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7497\" data-end=\"7539\"\u003e\n\n\u003cp data-start=\"7499\" data-end=\"7539\"\u003e \u003cstrong data-start=\"7499\" data-end=\"7524\"\u003eQualified and meticulous refrigeration technicians\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7540\" data-end=\"7619\"\u003e\n\n\u003cp data-start=\"7542\" data-end=\"7619\"\u003e Comprehensive support: assessment, installation, commissioning and follow-up\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7621\" data-end=\"7734\"\u003eWe always favour solutions that are adapted to the reality of the building and the actual expectations of the occupants.\u003c\/p\u003e\n\n\u003ch2 data-start=\"7736\" data-end=\"7770\"\u003e Guarantee and long-term vision\u003c\/h2\u003e\n\n\u003cp data-start=\"7772\" data-end=\"7993\"\u003e The \u003cstrong data-start=\"7775\" data-end=\"7830\"\u003e10-year warranty on the compressor and parts\u003c\/strong\u003e offers valuable peace of mind. Additional warranty options may be considered depending on the nature of the project and the intended use of the system.\u003c\/p\u003e\n\n\u003ch2 data-start=\"7995\" data-end=\"8014\"\u003e Conclusion\u003c\/h2\u003e\n\n \u003cp data-start=\"8016\" data-end=\"8342\"\u003eAre you considering installing a \u003cstrong data-start=\"8052\" data-end=\"8112\"\u003eGREE CROSSOVER R32 9,000 BTU single-way cassette heat pump\u003c\/strong\u003e in \u003cstrong data-start=\"8115\" data-end=\"8127\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"8129\" data-end=\"8138\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"8140\" data-end=\"8153\"\u003eLongueuil\u003c\/strong\u003e , on the \u003cstrong data-start=\"8162\" data-end=\"8175\"\u003eNorth Shore\u003c\/strong\u003e or \u003cstrong data-start=\"8182\" data-end=\"8194\"\u003eSouth Shore\u003c\/strong\u003e ? Contact \u003cstrong data-start=\"8214\" data-end=\"8226\"\u003eAirGreen\u003c\/strong\u003e for a complete technical assessment, a detailed quote and a solution truly tailored to your space.\u003c\/p\u003e","brand":"Gree","offers":[{"title":"Default Title","offer_id":51973345411364,"sku":"216618207","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CASSETTEDEPLAFOND1VOIEGREECROSSOVERR32.png?v=1769967743","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-cassette-1-voie-gree-crossover-r32-9000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}