{"product_id":"thermopompe-centrale-add-on-arcoaire-compact-quiet-comfort-2-tonnes-24000-btu-serpentin-dlfula-14-5-po-r410a","title":"Central Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A","description":"\u003ch2\u003eA heat pump on a narrow electric furnace, even when space is tight\u003c\/h2\u003e\u003cp\u003eIn townhouses and small homes, the \u003cstrong\u003eelectric furnace\u003c\/strong\u003e often sits in a closet or a corner of the basement where every inch counts. The \u003cstrong\u003eCentral Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A\u003c\/strong\u003e is designed for these narrow furnaces. It pairs the \u003cstrong\u003eDLCURAH24ABK\u003c\/strong\u003e outdoor unit with the \u003cstrong\u003eDLFULAH24XAX\u003c\/strong\u003e coil, which is installed on the existing furnace; the heat pump heats and cools through the same \u003cstrong\u003educts\u003c\/strong\u003e, and the furnace's elements only serve as backup.\u003c\/p\u003e\u003cp\u003eIts certified ratings are \u003cstrong\u003e16.1 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10.7 EER2\u003c\/strong\u003e and \u003cstrong\u003e9.8 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 2841438\u003c\/strong\u003e, its certificate still lists capacity at \u003cstrong\u003e-25 °C\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $2,688\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eThe 14.5 in. coil and the ADD-ON approach\u003c\/h3\u003e\u003cp\u003eIn an \u003cstrong\u003eADD-ON\u003c\/strong\u003e system, the electric furnace keeps its role as blower, and its elements become the backup heat. The heat pump coil sits on its air outlet: when the heat pump runs, the furnace blower pushes air through that coil, which warms it in winter and cools it in summer.\u003c\/p\u003e\u003cp\u003eFor all the air to pass through the coil, its width must match the furnace's. The \u003cstrong\u003e14.5 in.\u003c\/strong\u003e coil is meant for narrow furnaces, common in compact homes. The same system is also available with a wider coil for larger furnaces; we measure your unit on site before confirming the model.\u003c\/p\u003e\u003ch3\u003eThe homes it is meant for\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003e2-ton\u003c\/strong\u003e size, or \u003cstrong\u003e24,000 BTU\/h\u003c\/strong\u003e, often suits a townhouse on two or three levels, a bungalow with a basement or a semi-detached house in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, heated by an electric furnace still in good condition. These homes have often never had central air conditioning, for lack of space for another unit.\u003c\/p\u003e\u003cp\u003eThe size is confirmed by a room-by-room on-site assessment that accounts for insulation, windows and orientation. In an ADD-ON system, we choose the size first for cooling, then check the share of heating the heat pump will be able to take on before the furnace's elements take over.\u003c\/p\u003e\u003ch3\u003eWhy keep the furnace\u003c\/h3\u003e\u003cp\u003eKeeping an electric furnace in good condition as backup has several advantages. Its elements already do the backup work, so there are no heating elements to add: only the outdoor unit needs a new circuit, which spares the capacity of the electrical panel, often limited in a townhouse. The work involves the heat pump only, since the furnace, the plenum and the ducts stay in place. Finally, the home keeps two heat sources to get through deep cold: the heat pump for most of the winter, the furnace's elements for the harshest nights.\u003c\/p\u003e\u003ch3\u003eA certificate that stops at -25 °C\u003c\/h3\u003e\u003cp\u003eThe certificate lists \u003cstrong\u003e22,400 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) with a \u003cstrong\u003eCOP of 2.42\u003c\/strong\u003e, about 93% of the nominal size, and \u003cstrong\u003e20,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F) with a \u003cstrong\u003eCOP of 2.00\u003c\/strong\u003e. The two points are measured separately; we report each one as published. Its coldest point is \u003cstrong\u003e-25 °C\u003c\/strong\u003e, where it lists \u003cstrong\u003e16,500 BTU\/h\u003c\/strong\u003e with a \u003cstrong\u003eCOP of 1.61\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThat last point deserves an explanation. The certificate does not list any colder data, and we do not guess it. In an ADD-ON system, this is hardly an issue: the electric furnace is there for the coldest nights of a \u003cstrong\u003eMontreal\u003c\/strong\u003e winter. The thermostat brings its elements in as backup as soon as the heat pump can no longer hold the set point. These figures come from certificate \u003cstrong\u003eAHRI 213372117\u003c\/strong\u003e, published by NEEP.\u003c\/p\u003e\u003ch3\u003eThe thermostat and the electric backup\u003c\/h3\u003e\u003cp\u003eA compatible thermostat hands the heating to the heat pump first. When, in deep cold, it can no longer hold the set point, the thermostat brings in the electric furnace's elements as auxiliary heat, then takes them out as soon as the heat pump is enough again.\u003c\/p\u003e\u003cp\u003eThe backup setting depends on the heat pump's capacity, the home's heat loss and your preferences. Backup that comes in too early runs the elements when the heat pump would be enough; backup that comes in too late can leave the house cool in deep cold. We set it during commissioning and adjust it if needed after the first weeks of winter.\u003c\/p\u003e\u003ch3\u003eWhat the ratings measure\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e9.8 HSPF2\u003c\/strong\u003e: the heat pump's efficiency over the whole heating season.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCOP of 2.42 at -8 °C\u003c\/strong\u003e: heat delivered divided by electricity used. An electric furnace's elements never deliver more heat than the electricity they receive; the heat pump delivers nearly two and a half times as much here.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e16.1 SEER2\u003c\/strong\u003e: cooling efficiency over a typical summer.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e10.7 EER2\u003c\/strong\u003e: cooling efficiency at full load, on a hot day.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eAir conditioning, at last\u003c\/h3\u003e\u003cp\u003eIn summer, the heat pump cools every room served by the ducts, including the top-floor bedrooms of a townhouse, often the warmest. Its \u003cstrong\u003evariable-speed\u003c\/strong\u003e (\u003cstrong\u003einverter\u003c\/strong\u003e) compressor slows down as it approaches the set point and runs for long periods at low speed, which removes moisture instead of only cooling the air. The system runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e, a refrigerant that refrigeration technicians know well.\u003c\/p\u003e\u003ch3\u003eIndicative LogisVert amount: $2,688\u003c\/h3\u003e\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$2,688\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. The amount corresponds to the certified pairing of the DLCURAH24ABK outdoor unit and the DLFULAH24XAX coil.\u003c\/p\u003e\u003cp\u003eWe confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\u003ch2\u003eInstallation on the existing furnace\u003c\/h2\u003e\u003ch3\u003eInstalling in a tight space\u003c\/h3\u003e\u003cp\u003eBefore the quote, we check the condition of the electric furnace and its elements, its age, its blower and the airflow it can deliver, along with the duct sizes and the air return. In a mechanical closet, we also measure the height available above the unit: the coil fits between the furnace and the plenum, which is adjusted or rebuilt as needed. If the coil cannot drain by gravity to a floor drain, a condensate pump is included.\u003c\/p\u003e\u003cp\u003eThe insulated copper line set follows the most discreet route possible to the outdoor unit, mounted on a wall bracket or a stand, \u003cstrong\u003eabove the snow line\u003c\/strong\u003e, away from roof drip. It is brazed, pressure-tested and put under vacuum. The outdoor unit is connected on a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, with an outdoor disconnect, and the thermostat is replaced with a model that manages the heat pump and the furnace's electric backup. Commissioning checks the charge, airflow, defrost and the backup setting.\u003c\/p\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eThe furnace filter now serves both units: check it every month in season and replace it according to its format. Keep the outdoor unit clear of snow and leaves, without covering it. Annual \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance covers the heat pump's coil, condensate drain or pump and electrical connections, in addition to a check of the electric furnace and its elements. The white vapour during defrost, in winter, is normal.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Central Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A. We measure your furnace, check the available space and confirm your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797823979812,"sku":"DLCURAH24ABK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_ADD_ON_ARCOAIRE_DLCURA_2_TONNES_24000_BTU_R410A_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082528","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-add-on-arcoaire-compact-quiet-comfort-2-tonnes-24000-btu-serpentin-dlfula-14-5-po-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}