{"product_id":"thermopompe-centrale-add-on-elios-r410a-2-5t-serpentin-en-boite","title":"ELIOS R410A \"ADD-ON\" Central Heat Pump | 2.5T - Cased Coil","description":"\u003ch2 data-start=\"90\" data-end=\"180\"\u003e A central heat pump designed for existing systems and the actual climate of Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"182\" data-end=\"644\"\u003e At AirGreen, we have been installing, repairing, and optimizing \u003cstrong data-start=\"241\" data-end=\"267\"\u003ecentral HVAC systems\u003c\/strong\u003e for over fifteen years in \u003cstrong data-start=\"296\" data-end=\"308\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"310\" data-end=\"319\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"321\" data-end=\"334\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"343\" data-end=\"356\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"363\" data-end=\"375\"\u003eSouth\u003c\/strong\u003e Shores. The \u003cstrong data-start=\"380\" data-end=\"453\"\u003eELIOS R410A | 2.5T \"ADD-ON\" central heat pump with boxed coil\u003c\/strong\u003e is perfectly suited to the needs of many Quebec buildings: single-family homes, duplexes, triplexes, and multi-unit buildings already equipped with a functional ductwork system.\u003c\/p\u003e\n\n \u003cp data-start=\"646\" data-end=\"987\"\u003eThis model was designed with a logic of intelligent improvement in mind. Rather than demolishing, replacing or rebuilding a complete system, it allows for the \u003cstrong data-start=\"796\" data-end=\"835\"\u003eimprovement of an existing installation\u003c\/strong\u003e , increasing its energy efficiency and stabilizing its comfort, while respecting the technical and budgetary constraints of the owners.\u003c\/p\u003e\n\n\u003cp data-start=\"989\" data-end=\"1202\"\u003e In practice, this is a solution we often recommend when the air distribution is adequate, but the thermal performance or electrical consumption no longer meets current expectations.\u003c\/p\u003e\n\n\u003chr data-start=\"1204\" data-end=\"1207\"\u003e\n\n\u003ch2 data-start=\"1209\" data-end=\"1269\"\u003e Understanding the \"ADD-ON\" logic in a real-world HVAC project\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1271\" data-end=\"1333\"\u003e An approach adapted to homes already equipped with ducts\u003c\/h3\u003e\n\n \u003cp data-start=\"1335\" data-end=\"1495\"\u003eIn many of the projects completed by AirGreen, particularly in \u003cstrong data-start=\"1405\" data-end=\"1414\"\u003eAnjou\u003c\/strong\u003e , \u003cstrong data-start=\"1416\" data-end=\"1433\"\u003eSaint-Léonard\u003c\/strong\u003e , \u003cstrong data-start=\"1435\" data-end=\"1449\"\u003eTerrebonne\u003c\/strong\u003e and \u003cstrong data-start=\"1453\" data-end=\"1465\"\u003eBrossard\u003c\/strong\u003e , clients already have: \u003c\/p\u003e\n\n\u003cul data-start=\"1496\" data-end=\"1602\"\u003e\n\n\u003cli data-start=\"1496\" data-end=\"1518\"\u003e\n\n\u003cp data-start=\"1498\" data-end=\"1518\"\u003e from a central plenum, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1519\" data-end=\"1551\"\u003e\n\n\u003cp data-start=\"1521\" data-end=\"1551\"\u003e of properly sized conduits, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1552\" data-end=\"1602\"\u003e\n\n\u003cp data-start=\"1554\" data-end=\"1602\"\u003e of an existing electric or dual-energy heating system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1604\" data-end=\"1928\"\u003e The ELIOS central heat pump's \u003cstrong data-start=\"1621\" data-end=\"1631\"\u003eADD-ON\u003c\/strong\u003e configuration allows for \u003cstrong data-start=\"1676\" data-end=\"1719\"\u003edirect integration into the existing system\u003c\/strong\u003e , without altering the building's architecture or compromising air distribution. The \u003cstrong data-start=\"1807\" data-end=\"1829\"\u003eboxed coil\u003c\/strong\u003e facilitates a clean, airtight, and durable connection, while adhering to best HVAC practices.\u003c\/p\u003e\n\n\u003cp data-start=\"1930\" data-end=\"1977\"\u003e In practice, this approach translates into: \u003c\/p\u003e\n\n\u003cul data-start=\"1978\" data-end=\"2124\"\u003e\n\n\u003cli data-start=\"1978\" data-end=\"2006\"\u003e\n\n\u003cp data-start=\"1980\" data-end=\"2006\"\u003e fewer invasive procedures,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2007\" data-end=\"2048\"\u003e\n\n \u003cp data-start=\"2009\" data-end=\"2048\"\u003ea faster and cleaner construction site \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2049\" data-end=\"2085\"\u003e\n\n\u003cp data-start=\"2051\" data-end=\"2085\"\u003e a reduction in indirect costs, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2086\" data-end=\"2124\"\u003e\n\n\u003cp data-start=\"2088\" data-end=\"2124\"\u003e a more predictable commissioning. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"2126\" data-end=\"2129\"\u003e\n\n\u003ch2 data-start=\"2131\" data-end=\"2188\"\u003e Heating performance designed for Quebec winters\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2190\" data-end=\"2225\"\u003e Stable heating down to -30°C\u003c\/h3\u003e\n\n\u003cp data-start=\"2227\" data-end=\"2543\"\u003e The climate of \u003cstrong data-start=\"2240\" data-end=\"2252\"\u003eMontreal\u003c\/strong\u003e , the \u003cstrong data-start=\"2260\" data-end=\"2273\"\u003eNorth Shore\u003c\/strong\u003e , and the \u003cstrong data-start=\"2283\" data-end=\"2297\"\u003eMontérégie\u003c\/strong\u003e region imposes demands that few central systems can truly meet over the long term. The \u003cstrong data-start=\"2392\" data-end=\"2429\"\u003eELIOS ADD-ON central heat pump\u003c\/strong\u003e is designed to maintain reliable heating performance down to \u003cstrong data-start=\"2500\" data-end=\"2510\"\u003e-30°C\u003c\/strong\u003e , without a sudden drop in capacity.\u003c\/p\u003e\n\n\u003cp data-start=\"2545\" data-end=\"2645\"\u003e In installations carried out by AirGreen, this stability is particularly appreciated during: \u003c\/p\u003e\n\n\u003cul data-start=\"2646\" data-end=\"2801\"\u003e\n\n\u003cli data-start=\"2646\" data-end=\"2679\"\u003e\n\n\u003cp data-start=\"2648\" data-end=\"2679\"\u003e prolonged cold spells, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2680\" data-end=\"2725\"\u003e\n\n\u003cp data-start=\"2682\" data-end=\"2725\"\u003e very cold nights combined with wind,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2726\" data-end=\"2801\"\u003e\n\n \u003cp data-start=\"2728\" data-end=\"2801\"\u003eperiods when the heat pump becomes the main source of heating.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"2803\" data-end=\"2992\"\u003e Thanks to \u003cstrong data-start=\"2826\" data-end=\"2835\"\u003eHEAT+\u003c\/strong\u003e technology, the system maintains high capacity at low temperatures, which limits the need for backup sources and improves energy cost control.\u003c\/p\u003e\n\n\u003chr data-start=\"2994\" data-end=\"2997\"\u003e\n\n\u003ch2 data-start=\"2999\" data-end=\"3066\"\u003e Inverter technology: continuous comfort and controlled energy consumption\u003c\/h2\u003e\n\n\u003ch3 data-start=\"3068\" data-end=\"3114\"\u003e Precise modulation, no unnecessary cycles\u003c\/h3\u003e\n\n\u003cp data-start=\"3116\" data-end=\"3339\"\u003e The \u003cstrong data-start=\"3119\" data-end=\"3143\"\u003einverter compressor\u003c\/strong\u003e integrated into this model adjusts its power progressively, in very fine increments. Unlike traditional systems that operate in on\/off mode, this modulation allows: \u003c\/p\u003e\n\n\u003cul data-start=\"3340\" data-end=\"3516\"\u003e\n\n\u003cli data-start=\"3340\" data-end=\"3381\"\u003e\n\n\u003cp data-start=\"3342\" data-end=\"3381\"\u003e a more stable indoor temperature \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3382\" data-end=\"3425\"\u003e\n\n\u003cp data-start=\"3384\" data-end=\"3425\"\u003e fewer sudden starts and stops, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3426\" data-end=\"3463\"\u003e\n\n\u003cp data-start=\"3428\" data-end=\"3463\"\u003e a reduction in mechanical wear, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3464\" data-end=\"3516\"\u003e\n\n\u003cp data-start=\"3466\" data-end=\"3516\"\u003e a decrease in annual electricity consumption.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"3518\" data-end=\"3773\"\u003eIn homes in \u003cstrong data-start=\"3538\" data-end=\"3547\"\u003eLaval\u003c\/strong\u003e and \u003cstrong data-start=\"3554\" data-end=\"3567\"\u003eLongueuil\u003c\/strong\u003e where we replaced old central systems, occupants quickly noticed the difference: less temperature variation, more homogeneous air and significantly quieter operation.\u003c\/p\u003e\n\n\u003chr data-start=\"3775\" data-end=\"3778\"\u003e\n\n\u003ch2 data-start=\"3780\" data-end=\"3837\"\u003e Key technical data interpreted in a concrete way\u003c\/h2\u003e\n\n\u003ch3 data-start=\"3839\" data-end=\"3879\"\u003e Realistic capacity and sizing\u003c\/h3\u003e\n\n\u003cp data-start=\"3881\" data-end=\"4110\"\u003e With a \u003cstrong data-start=\"3890\" data-end=\"3939\"\u003erated power of 30,000 BTU (2.5 tonnes)\u003c\/strong\u003e , this model is perfectly suited to medium-sized residences, often between 1,200 and 2,000 square feet depending on the insulation, orientation and airtightness of the building.\u003c\/p\u003e\n\n\u003cp data-start=\"4112\" data-end=\"4152\"\u003e Some important technical points: \u003c\/p\u003e\n\n\u003cul data-start=\"4153\" data-end=\"4392\"\u003e\n\n\u003cli data-start=\"4153\" data-end=\"4197\"\u003e\n\n\u003cp data-start=\"4155\" data-end=\"4197\"\u003e \u003cstrong data-start=\"4155\" data-end=\"4184\"\u003eAir conditioning capacity\u003c\/strong\u003e : 30,000 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4198\" data-end=\"4255\"\u003e\n\n\u003cp data-start=\"4200\" data-end=\"4255\"\u003e \u003cstrong data-start=\"4200\" data-end=\"4234\"\u003eHeating capacity at -8°C\u003c\/strong\u003e : approximately 19,600 BTU\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4256\" data-end=\"4314\"\u003e\n\n \u003cp data-start=\"4258\" data-end=\"4314\"\u003e\u003cstrong data-start=\"4258\" data-end=\"4293\"\u003eHeating capacity at -15°C\u003c\/strong\u003e : approximately 22,600 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4315\" data-end=\"4333\"\u003e\n\n\u003cp data-start=\"4317\" data-end=\"4333\"\u003e \u003cstrong data-start=\"4317\" data-end=\"4326\"\u003eSEER2\u003c\/strong\u003e : 15.2 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4334\" data-end=\"4351\"\u003e\n\n\u003cp data-start=\"4336\" data-end=\"4351\"\u003e \u003cstrong data-start=\"4336\" data-end=\"4345\"\u003eHSPF2\u003c\/strong\u003e : 8.5 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4352\" data-end=\"4392\"\u003e\n\n\u003cp data-start=\"4354\" data-end=\"4392\"\u003e \u003cstrong data-start=\"4354\" data-end=\"4392\"\u003eHigh COP in winter conditions\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4394\" data-end=\"4575\"\u003e At AirGreen, we always insist on a \u003cstrong data-start=\"4440\" data-end=\"4477\"\u003eprecise thermal load calculation\u003c\/strong\u003e , because good performance depends as much on the product as on its sizing and installation.\u003c\/p\u003e\n\n\u003chr data-start=\"4577\" data-end=\"4580\"\u003e\n\n\u003ch2 data-start=\"4582\" data-end=\"4616\"\u003e Noise level and quality of life\u003c\/h2\u003e\n\n\u003ch3 data-start=\"4618\" data-end=\"4683\"\u003e A discreet central system, both indoors and outdoors\u003c\/h3\u003e\n\n \u003cp data-start=\"4685\" data-end=\"4987\"\u003eWith an \u003cstrong data-start=\"4693\" data-end=\"4739\"\u003eoutdoor noise level of approximately 62 dB(A)\u003c\/strong\u003e , the ELIOS central heat pump offers a significant advantage over many traditional central systems. In dense residential areas such as \u003cstrong data-start=\"4898\" data-end=\"4910\"\u003eVilleray\u003c\/strong\u003e , \u003cstrong data-start=\"4912\" data-end=\"4924\"\u003eAhuntsic\u003c\/strong\u003e , or \u003cstrong data-start=\"4928\" data-end=\"4950\"\u003eOld Longueuil\u003c\/strong\u003e , this criterion is often a deciding factor.\u003c\/p\u003e\n\n\u003cp data-start=\"4989\" data-end=\"5222\"\u003e Inside, the combination of the Inverter motor and the well-controlled airflow allows for smoother operation, without excessive whistling or vibrations in the ducts, provided that the installation is carried out correctly.\u003c\/p\u003e\n\n\u003chr data-start=\"5224\" data-end=\"5227\"\u003e\n\n\u003ch2 data-start=\"5229\" data-end=\"5274\"\u003e Concrete examples of AirGreen installations\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5276\" data-end=\"5312\"\u003e 1990s bungalow in Laval\u003c\/h3\u003e\n\n \u003cp data-start=\"5314\" data-end=\"5643\"\u003eIn a typical \u003cstrong data-start=\"5342\" data-end=\"5351\"\u003eLaval\u003c\/strong\u003e bungalow, the client wanted to improve their winter comfort while keeping their existing electric heating. We installed the \u003cstrong data-start=\"5482\" data-end=\"5534\"\u003eELIOS R410A | 2.5T \"ADD-ON\" central heat pump\u003c\/strong\u003e , adjusted the coil, verified the electrical capacity ( \u003cstrong data-start=\"5588\" data-end=\"5608\"\u003eMCA 30A, MOP 50A\u003c\/strong\u003e ), and optimized the airflow.\u003c\/p\u003e\n\n\u003cp data-start=\"5645\" data-end=\"5689\"\u003e Result observed after a full season: \u003c\/p\u003e\n\n\u003cul data-start=\"5690\" data-end=\"5854\"\u003e\n\n\u003cli data-start=\"5690\" data-end=\"5722\"\u003e\n\n\u003cp data-start=\"5692\" data-end=\"5722\"\u003e improved thermal stability \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5723\" data-end=\"5764\"\u003e\n\n\u003cp data-start=\"5725\" data-end=\"5764\"\u003e reduction in peak consumption, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5765\" data-end=\"5814\"\u003e\n\n\u003cp data-start=\"5767\" data-end=\"5814\"\u003e access to the \u003cstrong data-start=\"5778\" data-end=\"5813\"\u003eLogisVert grant of $2,352\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5815\" data-end=\"5854\"\u003e\n\n\u003cp data-start=\"5817\" data-end=\"5854\"\u003e Significant reduction in outside noise.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-start=\"5856\" data-end=\"5902\"\u003e Intergenerational housing in Boucherville\u003c\/h3\u003e\n\n \u003cp data-start=\"5904\" data-end=\"6216\"\u003eIn a multigenerational home on the \u003cstrong data-start=\"5948\" data-end=\"5960\"\u003eSouth Shore\u003c\/strong\u003e , the goal was to achieve consistent comfort across two levels with different heating needs. Inverter modulation allowed for a gradual adjustment of power, avoiding the frequent temperature fluctuations associated with the old central system.\u003c\/p\u003e\n\n\u003chr data-start=\"6218\" data-end=\"6221\"\u003e\n\n\u003ch2 data-start=\"6223\" data-end=\"6298\"\u003e Technical points that we systematically check before installation\u003c\/h2\u003e\n\n\u003cp data-start=\"6300\" data-end=\"6352\"\u003e Each AirGreen project includes a complete analysis: \u003c\/p\u003e\n\n\u003cul data-start=\"6353\" data-end=\"6720\"\u003e\n\n\u003cli data-start=\"6353\" data-end=\"6387\"\u003e\n\n\u003cp data-start=\"6355\" data-end=\"6387\"\u003e condition and tightness of the ducts, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6388\" data-end=\"6445\"\u003e\n\n\u003cp data-start=\"6390\" data-end=\"6445\"\u003e compatibility of the plenum with the \u003cstrong data-start=\"6422\" data-end=\"6444\"\u003eboxed coil\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6446\" data-end=\"6502\"\u003e\n\n\u003cp data-start=\"6448\" data-end=\"6502\"\u003e \u003cstrong data-start=\"6475\" data-end=\"6501\"\u003epipe length and diameter (3\/8 – 3\/4)\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6503\" data-end=\"6549\"\u003e\n\n\u003cp data-start=\"6505\" data-end=\"6549\"\u003e electrical capacity available at \u003cstrong data-start=\"6539\" data-end=\"6548\"\u003e220 V\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6550\" data-end=\"6625\"\u003e\n\n\u003cp data-start=\"6552\" data-end=\"6625\"\u003e requirements for auxiliary electric resistance (5 to 25 kW depending on the building), \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6626\" data-end=\"6720\"\u003e\n\n\u003cp data-start=\"6628\" data-end=\"6720\"\u003e optimal positioning of the outdoor unit to reduce noise and improve maintenance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"6722\" data-end=\"6879\"\u003eThese checks help to avoid common errors: oversizing, short cycles, excessive condensation or lower than expected performance.\u003c\/p\u003e\n\n\u003chr data-start=\"6881\" data-end=\"6884\"\u003e\n\n\u003ch2 data-start=\"6886\" data-end=\"6935\"\u003e Long-term reliability and recommended maintenance\u003c\/h2\u003e\n\n\u003cp data-start=\"6937\" data-end=\"7112\"\u003e The ELIOS central heat pump is designed to operate stably year-round, even in demanding weather conditions. It is covered by: \u003c\/p\u003e\n\n\u003cul data-start=\"7113\" data-end=\"7248\"\u003e\n\n\u003cli data-start=\"7113\" data-end=\"7144\"\u003e\n\n\u003cp data-start=\"7115\" data-end=\"7144\"\u003e \u003cstrong data-start=\"7115\" data-end=\"7144\"\u003e10 years on the compressor\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7145\" data-end=\"7172\"\u003e\n\n\u003cp data-start=\"7147\" data-end=\"7172\"\u003e \u003cstrong data-start=\"7147\" data-end=\"7172\"\u003e10-year warranty on parts\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7173\" data-end=\"7248\"\u003e\n\n\u003cp data-start=\"7175\" data-end=\"7248\"\u003e \u003cstrong data-start=\"7175\" data-end=\"7203\"\u003e0 years on labor\u003c\/strong\u003e , with the option of an additional warranty\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7250\" data-end=\"7377\"\u003e At AirGreen, we always explain these elements transparently and offer a suitable \u003cstrong data-start=\"7343\" data-end=\"7368\"\u003eHVAC maintenance plan\u003c\/strong\u003e : \u003c\/p\u003e\n\n\u003cul data-start=\"7378\" data-end=\"7527\"\u003e\n\n\u003cli data-start=\"7378\" data-end=\"7400\"\u003e\n\n\u003cp data-start=\"7380\" data-end=\"7400\"\u003e annual inspection \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7401\" data-end=\"7426\"\u003e\n\n\u003cp data-start=\"7403\" data-end=\"7426\"\u003e coil cleaning \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7427\" data-end=\"7470\"\u003e\n\n\u003cp data-start=\"7429\" data-end=\"7470\"\u003e checking pressures and connections, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7471\" data-end=\"7527\"\u003e\n\n\u003cp data-start=\"7473\" data-end=\"7527\"\u003e calibration of wired or WiFi thermostat (optional).\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7529\" data-end=\"7630\"\u003eRegular maintenance prolongs the life of the system and maintains its energy performance.\u003c\/p\u003e\n\n\u003chr data-start=\"7632\" data-end=\"7635\"\u003e\n\n\u003ch2 data-start=\"7637\" data-end=\"7677\"\u003e Why entrust this project to AirGreen?\u003c\/h2\u003e\n\n\u003cp data-start=\"7679\" data-end=\"7826\"\u003e We only recommend systems we know in depth. This ELIOS central heat pump is one of the models we carry: \u003c\/p\u003e\n\n\u003cul data-start=\"7827\" data-end=\"7957\"\u003e\n\n\u003cli data-start=\"7827\" data-end=\"7874\"\u003e\n\n\u003cp data-start=\"7829\" data-end=\"7874\"\u003e installed in different types of buildings, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7875\" data-end=\"7906\"\u003e\n\n\u003cp data-start=\"7877\" data-end=\"7906\"\u003e followed over several seasons, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7907\" data-end=\"7957\"\u003e\n\n\u003cp data-start=\"7909\" data-end=\"7957\"\u003e evaluated under real-world Quebec conditions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7959\" data-end=\"7986\"\u003e Our approach is based on: \u003c\/p\u003e\n\n\u003cul data-start=\"7987\" data-end=\"8223\"\u003e\n\n\u003cli data-start=\"7987\" data-end=\"8022\"\u003e\n\n\u003cp data-start=\"7989\" data-end=\"8022\"\u003e \u003cstrong data-start=\"7993\" data-end=\"8021\"\u003eclear and detailed pricing\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8023\" data-end=\"8071\"\u003e\n\n\u003cp data-start=\"8025\" data-end=\"8071\"\u003e \u003cstrong data-start=\"8029\" data-end=\"8070\"\u003ecertified and experienced refrigeration technicians\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8072\" data-end=\"8105\"\u003e\n\n\u003cp data-start=\"8074\" data-end=\"8105\"\u003e concrete field expertise, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8106\" data-end=\"8163\"\u003e\n\n\u003cp data-start=\"8108\" data-end=\"8163\"\u003e \u003cstrong data-start=\"8147\" data-end=\"8162\"\u003e$5,000,000\u003c\/strong\u003e liability insurance \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8164\" data-end=\"8223\"\u003e\n\n\u003cp data-start=\"8166\" data-end=\"8223\"\u003e support before, during and after installation. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"8225\" data-end=\"8228\"\u003e\n\n\u003ch2 data-start=\"8230\" data-end=\"8263\"\u003e Conclusion\u003c\/h2\u003e\n\n \u003cp data-start=\"8265\" data-end=\"8567\"\u003eThe \u003cstrong data-start=\"8268\" data-end=\"8341\"\u003eELIOS R410A | 2.5T \"ADD-ON\" Central Heat Pump - Box Coil\u003c\/strong\u003e represents a coherent, reliable and durable solution for homeowners wishing \u003cstrong data-start=\"8429\" data-end=\"8470\"\u003eto optimize an existing central system\u003c\/strong\u003e , improve their winter comfort and reduce their energy consumption without unnecessary work.\u003c\/p\u003e\n\n \u003cp data-start=\"8569\" data-end=\"8910\"\u003eFor a \u003cstrong data-start=\"8578\" data-end=\"8611\"\u003ecomplete technical assessment\u003c\/strong\u003e , a \u003cstrong data-start=\"8616\" data-end=\"8653\"\u003eprecise heat load calculation\u003c\/strong\u003e , or a \u003cstrong data-start=\"8661\" data-end=\"8685\"\u003edetailed quote\u003c\/strong\u003e , contact \u003cstrong data-start=\"8697\" data-end=\"8749\"\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e . We serve \u003cstrong data-start=\"8767\" data-end=\"8779\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"8781\" data-end=\"8790\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"8792\" data-end=\"8805\"\u003eLongueuil\u003c\/strong\u003e , the \u003cstrong data-start=\"8810\" data-end=\"8823\"\u003eNorth Shore\u003c\/strong\u003e , and the \u003cstrong data-start=\"8830\" data-end=\"8842\"\u003eSouth Shore\u003c\/strong\u003e , with the same rigor and attention to detail on every project.\u003c\/p\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51962675462436,"sku":"214215183","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Copy_of_THERMOPOMPE_CENTRALE_GREE_UNIX_R32_V1_FULL_SYSTEM_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_6.png?v=1772454829","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-add-on-elios-r410a-2-5t-serpentin-en-boite","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}