{"product_id":"thermopompe-centrale-add-on-gree-flexx-r32-4t-serpentin-en-caisson","title":"GREE FLEXX R32 \"ADD-ON\" Central Heat Pump | 4T | Cased Coil","description":"\u003ch2 data-start=\"93\" data-end=\"168\"\u003e A central heat pump designed for the Quebec climate, without compromise\u003c\/h2\u003e\n\n\u003cp data-start=\"170\" data-end=\"678\"\u003e At AirGreen, we install central systems in very real-world conditions: prolonged winters down to \u003cstrong data-start=\"277\" data-end=\"287\"\u003e-25°C\u003c\/strong\u003e , periods of intense cold down to \u003cstrong data-start=\"317\" data-end=\"327\"\u003e-30°C\u003c\/strong\u003e , poorly insulated older homes in Montreal, airtight new constructions in Laval, multi-unit dwellings in Longueuil, wind-exposed residences on the \u003cstrong data-start=\"473\" data-end=\"486\"\u003eNorth Shore\u003c\/strong\u003e , and mixed-use buildings on the \u003cstrong data-start=\"514\" data-end=\"526\"\u003eSouth Shore\u003c\/strong\u003e . It is precisely in these contexts that the \u003cstrong data-start=\"572\" data-end=\"648\"\u003eGREE FLEXX R32 | 4T | Coil-in-Casing \"ADD-ON\" Central Heat Pump\u003c\/strong\u003e demonstrates its full potential.\u003c\/p\u003e\n\n \u003cp data-start=\"680\" data-end=\"1019\"\u003eThis system wasn't designed to offer good performance on paper alone. It's designed to \u003cstrong data-start=\"785\" data-end=\"839\"\u003edeliver stable, consistent, and predictable heating\u003c\/strong\u003e , even during the most demanding periods of a Quebec winter, while maintaining \u003cstrong data-start=\"929\" data-end=\"979\"\u003eefficient and comfortable central air conditioning\u003c\/strong\u003e during summer heat waves.\u003c\/p\u003e\n\n\u003cp data-start=\"1021\" data-end=\"1275\"\u003e With a \u003cstrong data-start=\"1030\" data-end=\"1065\"\u003enominal capacity of 48,000 BTU\u003c\/strong\u003e , \u003cstrong data-start=\"1071\" data-end=\"1125\"\u003efunctional heating capacity down to -30°C\u003c\/strong\u003e and advanced \u003cstrong data-start=\"1145\" data-end=\"1157\"\u003eINVERTER\u003c\/strong\u003e technology, this model is aimed at homeowners who want a serious, durable and technically sound solution.\u003c\/p\u003e\n\n\u003ch2 data-start=\"1277\" data-end=\"1351\"\u003e The ADD-ON concept: a smart and economically logical approach\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1353\" data-end=\"1392\"\u003e Integration without unnecessary demolition\u003c\/h3\u003e\n\n \u003cp data-start=\"1394\" data-end=\"1674\"\u003eThe \u003cstrong data-start=\"1404\" data-end=\"1414\"\u003eADD-ON\u003c\/strong\u003e format makes perfect sense in the Quebec market, where a large proportion of buildings already have an existing central system. Unlike a complete replacement, which often requires extensive work, the \u003cstrong data-start=\"1623\" data-end=\"1665\"\u003eGREE FLEXX ADD-ON Central Heat Pump\u003c\/strong\u003e allows you to: \u003c\/p\u003e\n\n\u003cul data-start=\"1676\" data-end=\"1944\"\u003e\n\n\u003cli data-start=\"1676\" data-end=\"1744\"\u003e\n\n\u003cp data-start=\"1678\" data-end=\"1744\"\u003e To \u003cstrong data-start=\"1681\" data-end=\"1744\"\u003eretain an existing electric furnace or heat exchanger\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1745\" data-end=\"1836\"\u003e\n\n\u003cp data-start=\"1747\" data-end=\"1836\"\u003e To use \u003cstrong data-start=\"1762\" data-end=\"1788\"\u003eexisting conduits\u003c\/strong\u003e , when these are adequately sized \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1837\" data-end=\"1881\"\u003e\n\n\u003cp data-start=\"1839\" data-end=\"1881\"\u003e To \u003cstrong data-start=\"1842\" data-end=\"1881\"\u003ereduce the overall costs of the project\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1882\" data-end=\"1944\"\u003e\n\n\u003cp data-start=\"1884\" data-end=\"1944\"\u003e To limit the impact of the works on the occupancy of the building\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1946\" data-end=\"2162\"\u003e In several projects carried out by AirGreen in Laval and on the South Shore, this approach has allowed clients to radically improve their thermal comfort without turning their mechanical room into a major construction site.\u003c\/p\u003e\n\n \u003ch3 data-start=\"2164\" data-end=\"2203\"\u003eThe key role of the coil in a box\u003c\/h3\u003e\n\n\u003cp data-start=\"2205\" data-end=\"2393\"\u003e The \u003cstrong data-start=\"2208\" data-end=\"2244\"\u003eGCAC48H\/NHA box-type coil\u003c\/strong\u003e plays a central role in this configuration. It acts as a thermal interface between the heat pump and the air distribution network, ensuring: \u003c\/p\u003e\n\n\u003cul data-start=\"2395\" data-end=\"2559\"\u003e\n\n\u003cli data-start=\"2395\" data-end=\"2438\"\u003e\n\n\u003cp data-start=\"2397\" data-end=\"2438\"\u003e \u003cstrong data-start=\"2401\" data-end=\"2438\"\u003eExcellent thermal transmission\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2439\" data-end=\"2488\"\u003e\n\n\u003cp data-start=\"2441\" data-end=\"2488\"\u003e An \u003cstrong data-start=\"2444\" data-end=\"2488\"\u003eairflow rate adapted to central systems\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2489\" data-end=\"2559\"\u003e\n\n\u003cp data-start=\"2491\" data-end=\"2559\"\u003e A clean and reliable integration with various blower cabinets\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"2561\" data-end=\"2724\"\u003e This component is often underestimated, but in practice, it directly influences temperature stability, air quality, and system durability.\u003c\/p\u003e\n\n\u003ch2 data-start=\"2726\" data-end=\"2779\"\u003e Real, measurable, and consistent performance\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2781\" data-end=\"2832\"\u003e Technical data adapted for everyday use\u003c\/h3\u003e\n\n\u003cp data-start=\"2834\" data-end=\"2975\"\u003e The \u003cstrong data-start=\"2837\" data-end=\"2887\"\u003eGREE FLEXX R32 – 4-tonne central heat pump\u003c\/strong\u003e delivers performance that translates concretely into everyday life: \u003c\/p\u003e\n\n\u003cul data-start=\"2977\" data-end=\"3243\"\u003e\n\n\u003cli data-start=\"2977\" data-end=\"3016\"\u003e\n\n \u003cp data-start=\"2979\" data-end=\"3016\"\u003e\u003cstrong data-start=\"2979\" data-end=\"3001\"\u003eRated power\u003c\/strong\u003e : 48,000 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3017\" data-end=\"3056\"\u003e\n\n\u003cp data-start=\"3019\" data-end=\"3056\"\u003e \u003cstrong data-start=\"3019\" data-end=\"3041\"\u003ePower at -15°C\u003c\/strong\u003e : 48,000 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3057\" data-end=\"3095\"\u003e\n\n\u003cp data-start=\"3059\" data-end=\"3095\"\u003e \u003cstrong data-start=\"3059\" data-end=\"3080\"\u003ePower at -8°C\u003c\/strong\u003e : 35,200 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3096\" data-end=\"3118\"\u003e\n\n\u003cp data-start=\"3098\" data-end=\"3118\"\u003e \u003cstrong data-start=\"3098\" data-end=\"3107\"\u003eSEER2\u003c\/strong\u003e : 15.230 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3119\" data-end=\"3141\"\u003e\n\n\u003cp data-start=\"3121\" data-end=\"3141\"\u003e \u003cstrong data-start=\"3121\" data-end=\"3130\"\u003eHSPF2\u003c\/strong\u003e : 18.515 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3142\" data-end=\"3170\"\u003e\n\n\u003cp data-start=\"3144\" data-end=\"3170\"\u003e \u003cstrong data-start=\"3144\" data-end=\"3159\"\u003eCOP at -8 °C\u003c\/strong\u003e : 11.853 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3171\" data-end=\"3243\"\u003e\n\n\u003cp data-start=\"3173\" data-end=\"3243\"\u003e \u003cstrong data-start=\"3173\" data-end=\"3193\"\u003eR-32 refrigerant\u003c\/strong\u003e , known for its superior energy efficiency\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3245\" data-end=\"3464\"\u003e In single-family homes in East Montreal, we observed \u003cstrong data-start=\"3321\" data-end=\"3356\"\u003eremarkable thermal stability\u003c\/strong\u003e , even during long periods of cold, with a notable reduction in the use of supplementary sources.\u003c\/p\u003e\n\n\u003ch3 data-start=\"3466\" data-end=\"3534\"\u003e INVERTER technology: continuous comfort and controlled energy consumption\u003c\/h3\u003e\n\n \u003cp data-start=\"3536\" data-end=\"3684\"\u003eThe variable-speed \u003cstrong data-start=\"3570\" data-end=\"3582\"\u003eINVERTER\u003c\/strong\u003e compressor adjusts its power in real time according to the building's actual demand. This precise modulation allows for: \u003c\/p\u003e\n\n\u003cul data-start=\"3686\" data-end=\"3908\"\u003e\n\n\u003cli data-start=\"3686\" data-end=\"3733\"\u003e\n\n\u003cp data-start=\"3688\" data-end=\"3733\"\u003e A \u003cstrong data-start=\"3692\" data-end=\"3733\"\u003emore constant indoor temperature\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3734\" data-end=\"3792\"\u003e\n\n\u003cp data-start=\"3736\" data-end=\"3792\"\u003e A \u003cstrong data-start=\"3740\" data-end=\"3792\"\u003ereduction in peak electricity consumption\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3793\" data-end=\"3857\"\u003e\n\n\u003cp data-start=\"3795\" data-end=\"3857\"\u003e Fewer on\/off cycles, therefore \u003cstrong data-start=\"3830\" data-end=\"3857\"\u003eless mechanical wear.\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3858\" data-end=\"3908\"\u003e\n\n\u003cp data-start=\"3860\" data-end=\"3908\"\u003e Quieter and more stable operation\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3910\" data-end=\"4070\"\u003e In multi-unit residential buildings and houses with variable occupancy, this technology makes a tangible difference in comfort and energy costs.\u003c\/p\u003e\n\n\u003ch2 data-start=\"4072\" data-end=\"4115\"\u003e Robust design and durable materials\u003c\/h2\u003e\n\n\u003ch3 data-start=\"4117\" data-end=\"4163\"\u003e Corrosion protection adapted to Quebec\u003c\/h3\u003e\n\n \u003cp data-start=\"4165\" data-end=\"4516\"\u003eThe internal coil is composed of \u003cstrong data-start=\"4203\" data-end=\"4247\"\u003ecopper tubes and aluminum fins\u003c\/strong\u003e , protected by an anti-corrosion coating. This feature is particularly important in areas exposed to humidity, salts, or rapid temperature variations, especially near rivers or in certain densely built-up urban areas.\u003c\/p\u003e\n\n\u003cp data-start=\"4518\" data-end=\"4682\"\u003e The outdoor unit also benefits from fins with \u003cstrong data-start=\"4573\" data-end=\"4598\"\u003ea hydrophilic coating\u003c\/strong\u003e , promoting water flow and limiting the accumulation of ice and debris.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4684\" data-end=\"4721\"\u003e Intelligent defrost management\u003c\/h3\u003e\n\n\u003cp data-start=\"4723\" data-end=\"4743\"\u003e The system includes: \u003c\/p\u003e\n\n\u003cul data-start=\"4745\" data-end=\"4866\"\u003e\n\n\u003cli data-start=\"4745\" data-end=\"4775\"\u003e\n\n\u003cp data-start=\"4747\" data-end=\"4775\"\u003e \u003cstrong data-start=\"4750\" data-end=\"4775\"\u003eIntelligent defrosting\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4776\" data-end=\"4817\"\u003e\n\n\u003cp data-start=\"4778\" data-end=\"4817\"\u003e A \u003cstrong data-start=\"4781\" data-end=\"4817\"\u003econdensation tray heater\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4818\" data-end=\"4866\"\u003e\n\n\u003cp data-start=\"4820\" data-end=\"4866\"\u003e Optimized thermal management of the compressor\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"4868\" data-end=\"5045\"\u003eThese components ensure reliable operation during frequent freeze-thaw cycles in winter, reducing yield losses and the risk of premature failure.\u003c\/p\u003e\n\n\u003ch2 data-start=\"5047\" data-end=\"5093\"\u003e Central installation: the AirGreen approach\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5095\" data-end=\"5155\"\u003e An HVAC installation that goes far beyond simply plugging it in.\u003c\/h3\u003e\n\n\u003cp data-start=\"5157\" data-end=\"5313\"\u003e At AirGreen, we know that a high-performing central heat pump can become inefficient if it's not properly integrated. That's why every project includes: \u003c\/p\u003e\n\n\u003cul data-start=\"5315\" data-end=\"5646\"\u003e\n\n\u003cli data-start=\"5315\" data-end=\"5370\"\u003e\n\n\u003cp data-start=\"5317\" data-end=\"5370\"\u003e A detailed analysis of the \u003cstrong data-start=\"5342\" data-end=\"5370\"\u003erequired airflow (CFM)\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5371\" data-end=\"5430\"\u003e\n\n\u003cp data-start=\"5373\" data-end=\"5430\"\u003e A \u003cstrong data-start=\"5396\" data-end=\"5430\"\u003estatic pressure check of the ducts\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5431\" data-end=\"5507\"\u003e\n\n\u003cp data-start=\"5433\" data-end=\"5507\"\u003e Precise adjustment of \u003cstrong data-start=\"5457\" data-end=\"5507\"\u003eelectrical sizing (MCA 40A \/ MOP 45A)\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5508\" data-end=\"5581\"\u003e\n\n\u003cp data-start=\"5510\" data-end=\"5581\"\u003e A complete validation of the \u003cstrong data-start=\"5540\" data-end=\"5581\"\u003ecompatibility of the coil in the enclosure\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5582\" data-end=\"5646\"\u003e\n\n\u003cp data-start=\"5584\" data-end=\"5646\"\u003e Optimization of the \u003cstrong data-start=\"5607\" data-end=\"5646\"\u003erefrigeration piping (3\/8 – 3\/4)\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"5648\" data-end=\"5783\"\u003eThis rigor helps to avoid common problems such as excessive noise, temperature variations or cycles that are too short.\u003c\/p\u003e\n\n\u003ch2 data-start=\"5785\" data-end=\"5840\"\u003e LogisVert subsidy: a concrete financial advantage\u003c\/h2\u003e\n\n\u003cp data-start=\"5842\" data-end=\"6033\"\u003e The \u003cstrong data-start=\"5845\" data-end=\"5898\"\u003eGREE FLEXX R32 | 4T \"ADD-ON\" Central Heat Pump\u003c\/strong\u003e is eligible for the \u003cstrong data-start=\"5919\" data-end=\"5955\"\u003eLogisVert provincial subsidy\u003c\/strong\u003e , with an amount of up to \u003cstrong data-start=\"5991\" data-end=\"6002\"\u003e$4,224\u003c\/strong\u003e depending on the criteria in force.\u003c\/p\u003e\n\n\u003cp data-start=\"6035\" data-end=\"6244\"\u003e In several recent projects in Longueuil and on the North Shore, this subsidy has allowed clients to invest in a superior quality central system while significantly reducing their net cost.\u003c\/p\u003e\n\n\u003ch2 data-start=\"6246\" data-end=\"6283\"\u003e Long-term guarantee and reliability \u003c\/h2\u003e\n\n\u003cul data-start=\"6285\" data-end=\"6410\"\u003e\n\n\u003cli data-start=\"6285\" data-end=\"6322\"\u003e\n\n\u003cp data-start=\"6287\" data-end=\"6322\"\u003e \u003cstrong data-start=\"6287\" data-end=\"6311\"\u003eCompressor warranty\u003c\/strong\u003e : 12 years \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6323\" data-end=\"6355\"\u003e\n\n\u003cp data-start=\"6325\" data-end=\"6355\"\u003e \u003cstrong data-start=\"6325\" data-end=\"6344\"\u003eParts warranty\u003c\/strong\u003e : 12 years\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6356\" data-end=\"6410\"\u003e\n\n \u003cp data-start=\"6358\" data-end=\"6410\"\u003e\u003cstrong data-start=\"6358\" data-end=\"6374\"\u003eLabor\u003c\/strong\u003e : not included (options available)\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6412\" data-end=\"6566\"\u003e At AirGreen, we always clearly explain the warranty conditions and available options to avoid any ambiguity after installation.\u003c\/p\u003e\n\n\u003ch2 data-start=\"6568\" data-end=\"6608\"\u003e Why entrust this project to AirGreen?\u003c\/h2\u003e\n\n\u003cp data-start=\"6610\" data-end=\"6718\"\u003e Choosing a central heat pump is a key decision for a building. AirGreen stands out because: \u003c\/p\u003e\n\n\u003cul data-start=\"6720\" data-end=\"7021\"\u003e\n\n\u003cli data-start=\"6720\" data-end=\"6767\"\u003e\n\n\u003cp data-start=\"6722\" data-end=\"6767\"\u003e \u003cstrong data-start=\"6726\" data-end=\"6767\"\u003eQualified and experienced refrigeration technicians\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6768\" data-end=\"6826\"\u003e\n\n\u003cp data-start=\"6770\" data-end=\"6826\"\u003e Proven expertise in \u003cstrong data-start=\"6796\" data-end=\"6826\"\u003ecentral HVAC installation\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6827\" data-end=\"6892\"\u003e\n\n\u003cp data-start=\"6829\" data-end=\"6892\"\u003e \u003cstrong data-start=\"6833\" data-end=\"6854\"\u003eTransparent pricing\u003c\/strong\u003e , confirmed before work begins \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6893\" data-end=\"6943\"\u003e\n\n\u003cp data-start=\"6895\" data-end=\"6943\"\u003e \u003cstrong data-start=\"6899\" data-end=\"6943\"\u003e$5 million liability insurance\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6944\" data-end=\"7021\"\u003e\n\n\u003cp data-start=\"6946\" data-end=\"7021\"\u003e An active presence in \u003cstrong data-start=\"6968\" data-end=\"7021\"\u003eMontreal, Laval, Longueuil, the North Shore and the South Shore\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7023\" data-end=\"7146\"\u003eOur goal is not to sell a product, but to deliver a \u003cstrong data-start=\"7088\" data-end=\"7145\"\u003ecoherent, sustainable system adapted to each building\u003c\/strong\u003e .\u003c\/p\u003e\n\n\u003ch2 data-start=\"7148\" data-end=\"7181\"\u003e Conclusion\u003c\/h2\u003e\n\n\u003cp data-start=\"7183\" data-end=\"7469\"\u003e The \u003cstrong data-start=\"7186\" data-end=\"7262\"\u003eGREE FLEXX R32 | 4T | Casing \"ADD-ON\" Central Heat Pump\u003c\/strong\u003e represents a solid central solution for homeowners looking for \u003cstrong data-start=\"7345\" data-end=\"7381\"\u003ereliable heating in cold climates\u003c\/strong\u003e , \u003cstrong data-start=\"7387\" data-end=\"7413\"\u003eefficient air conditioning\u003c\/strong\u003e , and smart integration with an existing system.\u003c\/p\u003e\n\n \u003cp data-start=\"7471\" data-end=\"7738\"\u003eFor a \u003cstrong data-start=\"7480\" data-end=\"7518\"\u003epersonalized technical assessment\u003c\/strong\u003e , a \u003cstrong data-start=\"7524\" data-end=\"7545\"\u003eclear quote\u003c\/strong\u003e , or to verify your eligibility for the \u003cstrong data-start=\"7588\" data-end=\"7612\"\u003eLogisVert grant\u003c\/strong\u003e , contact AirGreen directly. Our team will support you from the initial analysis to final commissioning.\u003c\/p\u003e","brand":"Gree","offers":[{"title":"Default Title","offer_id":51960720359716,"sku":"GCAC48H\/NHA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPECENTRALE-ADDON-GREECASEDCOIL_5b011d99-557b-44dd-8a73-17a620e23e8c.png?v=1769968410","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-add-on-gree-flexx-r32-4t-serpentin-en-caisson","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}