{"product_id":"thermopompe-centrale-add-on-gree-unix-r32-4t-serpentin-en-caisson","title":"GREE UNIX R32 \"ADD-ON\" Central Heat Pump | 4T | Coil in a Box","description":"\u003ch2 data-start=\"92\" data-end=\"206\"\u003e A central heat pump designed for Quebec's climate, existing buildings, and well-planned projects.\u003c\/h2\u003e\n\n\u003cp data-start=\"208\" data-end=\"644\"\u003e At AirGreen, we've been installing \u003cstrong data-start=\"243\" data-end=\"269\"\u003ecentral heat pumps\u003c\/strong\u003e in Greater Montreal long enough to know that a good product isn't judged solely on a spec sheet. It's judged in the field, in the middle of January, during a cold snap of \u003cstrong data-start=\"485\" data-end=\"495\"\u003e-25°C\u003c\/strong\u003e , in a real home with real occupants, existing ductwork, mechanical constraints, clear expectations, and a well-defined budget.\u003c\/p\u003e\n\n \u003cp data-start=\"646\" data-end=\"1018\"\u003eThe \u003cstrong data-start=\"649\" data-end=\"733\"\u003eGREE UNIX R32 \"ADD-ON\" Central Heat Pump | 4 tons with a boxed coil\u003c\/strong\u003e perfectly embodies this reality. This system was designed to meet the needs of homeowners who want \u003cstrong data-start=\"855\" data-end=\"926\"\u003eto drastically improve their comfort and energy efficiency\u003c\/strong\u003e without having to start from scratch or unnecessarily replace still-functional equipment.\u003c\/p\u003e\n\n\u003cp data-start=\"1020\" data-end=\"1313\"\u003e This is a strategic choice, particularly relevant for residences and buildings in \u003cstrong data-start=\"1117\" data-end=\"1176\"\u003eMontreal, Laval, Longueuil, the North Shore and the South Shore\u003c\/strong\u003e , where there are many existing central systems and where winters impose requirements far exceeding the North American average.\u003c\/p\u003e\n\n\u003chr data-start=\"1315\" data-end=\"1318\"\u003e\n\n\u003ch2 data-start=\"1320\" data-end=\"1387\"\u003e A true ADD-ON solution for modernizing without rebuilding everything\u003c\/h2\u003e\n\n\u003cp data-start=\"1389\" data-end=\"1482\"\u003e In a significant proportion of projects carried out by AirGreen, clients already own: \u003c\/p\u003e\n\n\u003cul data-start=\"1483\" data-end=\"1641\"\u003e\n\n\u003cli data-start=\"1483\" data-end=\"1536\"\u003e\n\n \u003cp data-start=\"1485\" data-end=\"1536\"\u003ean \u003cstrong data-start=\"1489\" data-end=\"1523\"\u003eelectric or gas furnace\u003c\/strong\u003e in good working order, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1537\" data-end=\"1573\"\u003e\n\n\u003cp data-start=\"1539\" data-end=\"1573\"\u003e a functional network of conduits, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1574\" data-end=\"1641\"\u003e\n\n\u003cp data-start=\"1576\" data-end=\"1641\"\u003e an old, inefficient central air conditioner or one that has reached the end of its lifespan.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1643\" data-end=\"1859\"\u003e In this context, replacing the entire system is not always logical, either economically or technically. This is precisely where the \u003cstrong data-start=\"1786\" data-end=\"1836\"\u003eADD-ON configuration with a boxed coil\u003c\/strong\u003e becomes truly valuable.\u003c\/p\u003e\n\n\u003ch3 data-start=\"1861\" data-end=\"1903\"\u003e Direct integration into the existing plenum\u003c\/h3\u003e\n\n\u003cp data-start=\"1905\" data-end=\"2071\"\u003e The \u003cstrong data-start=\"1908\" data-end=\"1944\"\u003eGCAC48H\/NhA boxed coil\u003c\/strong\u003e is designed for direct integration into the plenum, without major modifications to the ductwork. This approach allows for: \u003c\/p\u003e\n\n\u003cul data-start=\"2072\" data-end=\"2205\"\u003e\n\n\u003cli data-start=\"2072\" data-end=\"2107\"\u003e\n\n\u003cp data-start=\"2074\" data-end=\"2107\"\u003e \u003cstrong data-start=\"2078\" data-end=\"2106\"\u003efaster installation\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2108\" data-end=\"2136\"\u003e\n\n\u003cp data-start=\"2110\" data-end=\"2136\"\u003e fewer invasive procedures, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2137\" data-end=\"2172\"\u003e\n\n\u003cp data-start=\"2139\" data-end=\"2172\"\u003e better cost control, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2173\" data-end=\"2205\"\u003e\n\n\u003cp data-start=\"2175\" data-end=\"2205\"\u003e a clean and lasting result.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"2207\" data-end=\"2488\"\u003eOn several occasions, particularly in single-family homes in Laval and on the South Shore, this solution has made it possible to retain an existing furnace while adding a high-performance central heat pump, capable of providing primary heating for a large part of the winter.\u003c\/p\u003e\n\n\u003ch3 data-start=\"2490\" data-end=\"2533\"\u003e Valuable flexibility in renovation\u003c\/h3\u003e\n\n\u003cp data-start=\"2535\" data-end=\"2880\"\u003e In renovation projects, every centimeter counts. Mechanical rooms are often cramped, clearances limited, and room for maneuver reduced. The boxed coil format, combined with a well-proportioned outdoor unit, greatly facilitates integration into existing buildings, including Montreal duplexes and triplexes.\u003c\/p\u003e\n\n\u003chr data-start=\"2882\" data-end=\"2885\"\u003e\n\n\u003ch2 data-start=\"2887\" data-end=\"2947\"\u003e Heating efficiency: a top priority in Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"2949\" data-end=\"3094\"\u003e For a long time, the main weakness of central heat pumps was their efficiency during periods of intense cold. This is no longer the case here.\u003c\/p\u003e\n\n\u003ch3 data-start=\"3096\" data-end=\"3131\"\u003e Reliable heating down to -30°C\u003c\/h3\u003e\n\n \u003cp data-start=\"3133\" data-end=\"3301\"\u003eThe \u003cstrong data-start=\"3136\" data-end=\"3177\"\u003eGREE UNIX R32 4T central heat pump\u003c\/strong\u003e is designed to maintain \u003cstrong data-start=\"3208\" data-end=\"3255\"\u003estable heating capacity down to -30°C\u003c\/strong\u003e . In real-world conditions, this means: \u003c\/p\u003e\n\n\u003cul data-start=\"3302\" data-end=\"3444\"\u003e\n\n\u003cli data-start=\"3302\" data-end=\"3344\"\u003e\n\n\u003cp data-start=\"3304\" data-end=\"3344\"\u003e less reliance on supplementary elements, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3345\" data-end=\"3389\"\u003e\n\n\u003cp data-start=\"3347\" data-end=\"3389\"\u003e a more constant indoor temperature \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3390\" data-end=\"3444\"\u003e\n\n\u003cp data-start=\"3392\" data-end=\"3444\"\u003e a reduction in overall electricity consumption.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-start=\"3446\" data-end=\"3481\"\u003e Detailed thermal capacities \u003c\/h3\u003e\n\n\u003cul data-start=\"3483\" data-end=\"3658\"\u003e\n\n\u003cli data-start=\"3483\" data-end=\"3532\"\u003e\n\n\u003cp data-start=\"3485\" data-end=\"3532\"\u003e \u003cstrong data-start=\"3485\" data-end=\"3506\"\u003eNominal capacity\u003c\/strong\u003e : 48,000 BTU (4 tonnes) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3533\" data-end=\"3571\"\u003e\n\n\u003cp data-start=\"3535\" data-end=\"3571\"\u003e \u003cstrong data-start=\"3535\" data-end=\"3556\"\u003ePower at -8°C\u003c\/strong\u003e : 35,200 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3572\" data-end=\"3611\"\u003e\n\n\u003cp data-start=\"3574\" data-end=\"3611\"\u003e \u003cstrong data-start=\"3574\" data-end=\"3596\"\u003ePower at -15°C\u003c\/strong\u003e : 48,000 BTU \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3612\" data-end=\"3658\"\u003e\n\n\u003cp data-start=\"3614\" data-end=\"3658\"\u003e \u003cstrong data-start=\"3614\" data-end=\"3643\"\u003eCooling capacity\u003c\/strong\u003e : 48,000 BTU\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"3660\" data-end=\"3914\"\u003eThese figures are not abstract. They correspond to large houses, multi-unit dwellings or buildings where heat loss is significant, particularly on the \u003cstrong data-start=\"3849\" data-end=\"3862\"\u003eNorth Shore\u003c\/strong\u003e , which is more exposed to wind and extreme temperatures.\u003c\/p\u003e\n\n\u003chr data-start=\"3916\" data-end=\"3919\"\u003e\n\n\u003ch2 data-start=\"3921\" data-end=\"3979\"\u003e Measurable energy efficiency and concrete savings\u003c\/h2\u003e\n\n\u003cp data-start=\"3981\" data-end=\"4130\"\u003e A high-performance central heat pump must offer more than just power. It must do so \u003cstrong data-start=\"4075\" data-end=\"4091\"\u003eefficiently\u003c\/strong\u003e , day after day, season after season.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4132\" data-end=\"4156\"\u003e Efficiency indicators \u003c\/h3\u003e\n\n\u003cul data-start=\"4158\" data-end=\"4246\"\u003e\n\n\u003cli data-start=\"4158\" data-end=\"4178\"\u003e\n\n\u003cp data-start=\"4160\" data-end=\"4178\"\u003e \u003cstrong data-start=\"4160\" data-end=\"4169\"\u003eSEER2\u003c\/strong\u003e : 18.0 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4179\" data-end=\"4199\"\u003e\n\n\u003cp data-start=\"4181\" data-end=\"4199\"\u003e \u003cstrong data-start=\"4181\" data-end=\"4190\"\u003eHSPF2\u003c\/strong\u003e : 10.0 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4200\" data-end=\"4219\"\u003e\n\n\u003cp data-start=\"4202\" data-end=\"4219\"\u003e \u003cstrong data-start=\"4202\" data-end=\"4210\"\u003eEER2\u003c\/strong\u003e : 12.5 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4220\" data-end=\"4246\"\u003e\n\n\u003cp data-start=\"4222\" data-end=\"4246\"\u003e \u003cstrong data-start=\"4222\" data-end=\"4237\"\u003eCOP at -8 °C\u003c\/strong\u003e : 3.60\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"4248\" data-end=\"4525\"\u003eThese figures reflect \u003cstrong data-start=\"4275\" data-end=\"4335\"\u003eexcellent conversion of electrical energy into heat\u003c\/strong\u003e , even when the outside temperature drops. For homeowners, this translates directly into lower electricity bills, especially during extended heating periods.\u003c\/p\u003e\n\n\u003ch3 data-start=\"4527\" data-end=\"4551\"\u003e LogisVert Subsidy\u003c\/h3\u003e\n\n\u003cp data-start=\"4553\" data-end=\"4888\"\u003e This model is \u003cstrong data-start=\"4567\" data-end=\"4619\"\u003eeligible for the LogisVert provincial subsidy\u003c\/strong\u003e , with an amount of up to \u003cstrong data-start=\"4655\" data-end=\"4666\"\u003e$4,224\u003c\/strong\u003e , depending on the configuration and the application date. At AirGreen, we systematically assist our clients in verifying the criteria and preparing their application to maximize the available financial assistance.\u003c\/p\u003e\n\n\u003chr data-start=\"4890\" data-end=\"4893\"\u003e\n\n\u003ch2 data-start=\"4895\" data-end=\"4961\"\u003e R-32 refrigerant: a consistent choice for today and tomorrow\u003c\/h2\u003e\n\n\u003cp data-start=\"4963\" data-end=\"5047\"\u003e \u003cstrong data-start=\"4966\" data-end=\"4974\"\u003eR-32\u003c\/strong\u003e is not a mere technical detail. It is a fundamental choice: \u003c\/p\u003e\n\n\u003cul data-start=\"5048\" data-end=\"5215\"\u003e\n\n\u003cli data-start=\"5048\" data-end=\"5091\"\u003e\n\n \u003cp data-start=\"5050\" data-end=\"5091\"\u003e\u003cstrong data-start=\"5050\" data-end=\"5090\"\u003eimproved thermodynamic efficiency\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5092\" data-end=\"5139\"\u003e\n\n\u003cp data-start=\"5094\" data-end=\"5139\"\u003e \u003cstrong data-start=\"5094\" data-end=\"5138\"\u003ereduced global warming potential\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5140\" data-end=\"5215\"\u003e\n\n\u003cp data-start=\"5142\" data-end=\"5215\"\u003e increased compliance with current and future environmental standards.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5217\" data-end=\"5420\"\u003e For homeowners concerned about the sustainability of their investment and the environmental impact of their HVAC system, R-32 represents a balanced solution, without compromising on performance.\u003c\/p\u003e\n\n\u003chr data-start=\"5422\" data-end=\"5425\"\u003e\n\n\u003ch2 data-start=\"5427\" data-end=\"5465\"\u003e Compatibility, control and security\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5467\" data-end=\"5489\"\u003e 24 VAC Thermostats\u003c\/h3\u003e\n\n\u003cp data-start=\"5491\" data-end=\"5609\"\u003e Compatibility with \u003cstrong data-start=\"5517\" data-end=\"5549\"\u003estandard 24 VAC thermostats\u003c\/strong\u003e allows for a wide range of configuration options. This makes it easier to: \u003c\/p\u003e\n\n\u003cul data-start=\"5610\" data-end=\"5721\"\u003e\n\n\u003cli data-start=\"5610\" data-end=\"5654\"\u003e\n\n\u003cp data-start=\"5612\" data-end=\"5654\"\u003e integration with existing systems, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5655\" data-end=\"5693\"\u003e\n\n\u003cp data-start=\"5657\" data-end=\"5693\"\u003e the future replacement of the thermostat, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5694\" data-end=\"5721\"\u003e\n\n\u003cp data-start=\"5696\" data-end=\"5721\"\u003e long-term maintenance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 data-start=\"5723\" data-end=\"5753\"\u003e Communication and reliability\u003c\/h3\u003e\n\n \u003cp data-start=\"5755\" data-end=\"6040\"\u003e\u003cstrong data-start=\"5772\" data-end=\"5781\"\u003eRS485\u003c\/strong\u003e communication ensures stable and precise system management, while the \u003cstrong data-start=\"5845\" data-end=\"5903\"\u003erefrigerant leak detector integrated into the coil\u003c\/strong\u003e adds a significant level of safety, particularly in multi-unit residential buildings and light commercial buildings.\u003c\/p\u003e\n\n\u003chr data-start=\"6042\" data-end=\"6045\"\u003e\n\n\u003ch2 data-start=\"6047\" data-end=\"6111\"\u003e Essential technical specifications for demanding projects \u003c\/h2\u003e\n\n\u003cul data-start=\"6113\" data-end=\"6466\"\u003e\n\n\u003cli data-start=\"6113\" data-end=\"6156\"\u003e\n\n\u003cp data-start=\"6115\" data-end=\"6156\"\u003e \u003cstrong data-start=\"6115\" data-end=\"6135\"\u003eExterior model\u003c\/strong\u003e : GUD60W2\/NhE-D(U) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6157\" data-end=\"6195\"\u003e\n\n\u003cp data-start=\"6159\" data-end=\"6195\"\u003e \u003cstrong data-start=\"6159\" data-end=\"6179\"\u003eInterior model\u003c\/strong\u003e : GCAC48H\/NhA \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6196\" data-end=\"6220\"\u003e\n\n\u003cp data-start=\"6198\" data-end=\"6220\"\u003e \u003cstrong data-start=\"6198\" data-end=\"6206\"\u003eAHRI\u003c\/strong\u003e : 216768110 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6221\" data-end=\"6274\"\u003e\n\n\u003cp data-start=\"6223\" data-end=\"6274\"\u003e \u003cstrong data-start=\"6223\" data-end=\"6266\"\u003eENERGY STAR® Cold Climate Certification\u003c\/strong\u003e : Yes \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6275\" data-end=\"6298\"\u003e\n\n\u003cp data-start=\"6277\" data-end=\"6298\"\u003e \u003cstrong data-start=\"6277\" data-end=\"6288\"\u003eVoltage\u003c\/strong\u003e : 220 V \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6299\" data-end=\"6317\"\u003e\n\n\u003cp data-start=\"6301\" data-end=\"6317\"\u003e \u003cstrong data-start=\"6301\" data-end=\"6308\"\u003eMCA\u003c\/strong\u003e : 40 A \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6318\" data-end=\"6336\"\u003e\n\n\u003cp data-start=\"6320\" data-end=\"6336\"\u003e \u003cstrong data-start=\"6320\" data-end=\"6327\"\u003eMOP\u003c\/strong\u003e : 45 A\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6337\" data-end=\"6379\"\u003e\n\n \u003cp data-start=\"6339\" data-end=\"6379\"\u003e\u003cstrong data-start=\"6339\" data-end=\"6366\"\u003eOutdoor noise level\u003c\/strong\u003e : 62 dB(A) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6380\" data-end=\"6427\"\u003e\n\n\u003cp data-start=\"6382\" data-end=\"6427\"\u003e \u003cstrong data-start=\"6382\" data-end=\"6405\"\u003eMaximum airflow\u003c\/strong\u003e : up to 1,500 CFM \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6428\" data-end=\"6466\"\u003e\n\n\u003cp data-start=\"6430\" data-end=\"6466\"\u003e \u003cstrong data-start=\"6430\" data-end=\"6451\"\u003eDehumidification\u003c\/strong\u003e : 15.01 pt\/h\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6468\" data-end=\"6649\"\u003e These features make this model a perfect solution for \u003cstrong data-start=\"6545\" data-end=\"6573\"\u003ehigh-end residences\u003c\/strong\u003e , \u003cstrong data-start=\"6579\" data-end=\"6587\"\u003eplexes\u003c\/strong\u003e and certain \u003cstrong data-start=\"6610\" data-end=\"6625\"\u003ecommercial\u003c\/strong\u003e projects in Greater Montreal.\u003c\/p\u003e\n\n\u003chr data-start=\"6651\" data-end=\"6654\"\u003e\n\n\u003ch2 data-start=\"6656\" data-end=\"6698\"\u003e AirGreen field feedback and experiences\u003c\/h2\u003e\n\n \u003cp data-start=\"6700\" data-end=\"7064\"\u003eIn Longueuil, in a two-story house with a finished basement, the client experienced significant temperature differences between levels. After the installation of the \u003cstrong data-start=\"6870\" data-end=\"6915\"\u003eADD-ON GREE UNIX R32 central heat pump\u003c\/strong\u003e , combined with precise duct balancing, comfort became uniform throughout the house, even during periods of extreme cold.\u003c\/p\u003e\n\n\u003cp data-start=\"7066\" data-end=\"7287\"\u003e In Montreal North, in a triplex, the flexibility of the box coil allowed for integration without major modification of existing ducts, while respecting space constraints and safety requirements.\u003c\/p\u003e\n\n\u003chr data-start=\"7289\" data-end=\"7292\"\u003e\n\n\u003ch2 data-start=\"7294\" data-end=\"7352\"\u003e Common mistakes we help our clients avoid\u003c\/h2\u003e\n\n\u003cp data-start=\"7354\" data-end=\"7413\"\u003e With this type of system, certain errors are common: \u003c\/p\u003e\n\n\u003cul data-start=\"7414\" data-end=\"7589\"\u003e\n\n\u003cli data-start=\"7414\" data-end=\"7479\"\u003e\n\n\u003cp data-start=\"7416\" data-end=\"7479\"\u003e choosing an insufficient capacity to reduce the initial cost, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7480\" data-end=\"7525\"\u003e\n\n\u003cp data-start=\"7482\" data-end=\"7525\"\u003e ignoring the actual condition of existing conduits, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7526\" data-end=\"7589\"\u003e\n\n\u003cp data-start=\"7528\" data-end=\"7589\"\u003e neglecting the importance of sizing and balancing.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7591\" data-end=\"7861\"\u003eAt AirGreen, every project begins with a \u003cstrong data-start=\"7635\" data-end=\"7667\"\u003ecomplete building analysis\u003c\/strong\u003e , including heat loss, ductwork configuration, and occupancy patterns. This thorough approach avoids costly adjustments after installation and ensures long-lasting performance.\u003c\/p\u003e\n\n\u003chr data-start=\"7863\" data-end=\"7866\"\u003e\n\n\u003ch2 data-start=\"7868\" data-end=\"7917\"\u003e Why entrust your installation to AirGreen\u003c\/h2\u003e\n\n\u003cp data-start=\"7919\" data-end=\"7966\"\u003e Doing business with AirGreen means benefiting from: \u003c\/p\u003e\n\n\u003cul data-start=\"7967\" data-end=\"8253\"\u003e\n\n\u003cli data-start=\"7967\" data-end=\"8015\"\u003e\n\n\u003cp data-start=\"7969\" data-end=\"8015\"\u003e \u003cstrong data-start=\"7971\" data-end=\"8014\"\u003ecertified and experienced installers\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8016\" data-end=\"8075\"\u003e\n\n\u003cp data-start=\"8018\" data-end=\"8075\"\u003e of \u003cstrong data-start=\"8024\" data-end=\"8074\"\u003e$5,000,000 in liability insurance\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8076\" data-end=\"8139\"\u003e\n\n\u003cp data-start=\"8078\" data-end=\"8139\"\u003e \u003cstrong data-start=\"8081\" data-end=\"8109\"\u003eclear and detailed pricing\u003c\/strong\u003e , presented before the work begins, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8140\" data-end=\"8202\"\u003e\n\n\u003cp data-start=\"8142\" data-end=\"8202\"\u003e structured support for \u003cstrong data-start=\"8181\" data-end=\"8201\"\u003eHVAC subsidies\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8203\" data-end=\"8253\"\u003e\n\n\u003cp data-start=\"8205\" data-end=\"8253\"\u003e of an accessible and organized after-sales service.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"8255\" data-end=\"8447\"\u003eWe operate daily in \u003cstrong data-start=\"8290\" data-end=\"8353\"\u003eMontreal, Laval, Longueuil, on the North Shore and the South Shore\u003c\/strong\u003e , with an approach focused on sustainability, reliability and long-term satisfaction.\u003c\/p\u003e\n\n\u003chr data-start=\"8449\" data-end=\"8452\"\u003e\n\n\u003ch2 data-start=\"8454\" data-end=\"8487\"\u003e Conclusion\u003c\/h2\u003e\n\n\u003cp data-start=\"8489\" data-end=\"8897\"\u003e The \u003cstrong data-start=\"8492\" data-end=\"8567\"\u003eGREE UNIX R32 | 4T | Coil-in-Casket \"ADD-ON\" Central Heat Pump\u003c\/strong\u003e represents a robust, flexible, and high-performance solution for homeowners looking to upgrade their central heating system without compromise. Its heating capability in very cold weather, its intelligent integration with existing systems, and its energy efficiency make it a perfect choice for Quebec's climate.\u003c\/p\u003e\n\n \u003cp data-start=\"8899\" data-end=\"9149\"\u003e\u003cstrong data-start=\"8899\" data-end=\"8936\"\u003eContact AirGreen today\u003c\/strong\u003e for a personalized assessment, a detailed estimate, or to check your eligibility for available subsidies. Our team is ready to support you every step of the way with your HVAC project.\u003c\/p\u003e","brand":"Gree","offers":[{"title":"Default Title","offer_id":51960719835428,"sku":"GCAC48H\/NhA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPECENTRALE-ADDON-GREECASEDCOIL_717a6f92-803e-48a0-a8c9-64149f6fd2da.png?v=1769968480","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-add-on-gree-unix-r32-4t-serpentin-en-caisson","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}