{"product_id":"thermopompe-centrale-arcoaire-compact-quiet-comfort-2-5-tonnes-30000-btu-cabinet-d5fuaa-r454b","title":"Central Heat Pump ARCOAIRE QuietComfort Compact | 2.5 Tons - 30,000 BTU (Air Handler D5FUAA) - R454B","description":"\u003ch2\u003eA central heat pump that keeps its capacity as the cold sets in\u003c\/h2\u003e\u003cp\u003eMost heat pumps lose capacity as the outdoor temperature drops. According to its certificate, the \u003cstrong\u003eCentral Heat Pump ARCOAIRE QuietComfort Compact | 2.5 Tons - 30,000 BTU (Air Handler D5FUAA) - R454B\u003c\/strong\u003e does better than hold on: at -15 °C, it delivers more than its nominal size. It pairs the \u003cstrong\u003eD5CUHAH30AAK\u003c\/strong\u003e outdoor unit with the matching-size \u003cstrong\u003eD5FUAAH30XAK\u003c\/strong\u003e cabinet, which replaces the furnace and distributes air through the existing \u003cstrong\u003eductwork\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIts certified ratings are \u003cstrong\u003e16.9 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.7 EER2\u003c\/strong\u003e and \u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e under \u003cstrong\u003eENERGY STAR ID 3560727\u003c\/strong\u003e, its certificate lists capacity down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and our product sheet shows an \u003cstrong\u003eindicative LogisVert amount of $2,856\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eMore than its nominal capacity at -15 °C\u003c\/h3\u003e\u003cp\u003eThe certificate lists \u003cstrong\u003e23,800 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) with a \u003cstrong\u003eCOP of 2.76\u003c\/strong\u003e, then \u003cstrong\u003e32,600 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F) with a \u003cstrong\u003eCOP of 1.96\u003c\/strong\u003e. That second figure is about 109% of the 30,000 BTU\/h nominal size. The two points are measured separately; we report each one as published, without extrapolating.\u003c\/p\u003e\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 215318890\u003c\/strong\u003e, published by NEEP. For a home in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, where -15 °C mornings are nothing unusual in January, this means the heat pump keeps carrying most of the heating when another would already have left a large share to backup heat.\u003c\/p\u003e\u003ch3\u003eWhat this changes in choosing the size\u003c\/h3\u003e\u003cp\u003eWhen a heat pump loses a lot of capacity in the cold, it is tempting to choose a bigger size to cover winter. That choice takes its toll the rest of the year: an oversized unit short-cycles in spring and fall, and cools poorly in summer, because it chills the air too quickly without removing its moisture.\u003c\/p\u003e\u003cp\u003eWith winter capacity like this, it becomes possible to choose the size from the on-site assessment, with no upsizing for winter. In summer, the system then runs for long periods at low speed: air passing over the cold coil loses its moisture, the temperature stays steady, and the house is cool without being clammy. Condensate drains from the cabinet to a floor drain or a pump.\u003c\/p\u003e\u003ch3\u003eDown to -30 °C: the share of backup heat\u003c\/h3\u003e\u003cp\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e, the certificate still lists \u003cstrong\u003e20,100 BTU\/h\u003c\/strong\u003e with a \u003cstrong\u003eCOP of 1.55\u003c\/strong\u003e. Even on the coldest nights of a \u003cstrong\u003eMontreal\u003c\/strong\u003e winter, the heat pump therefore still delivers one and a half times the heat it uses in electricity.\u003c\/p\u003e\u003cp\u003eA house may still lose more heat than the outdoor unit supplies at those temperatures. Electric backup, usually housed in the cabinet, then supplements the heating. We size it from the on-site assessment and set the thermostat so it only comes on when needed. With a heat pump that keeps its capacity, those backup hours are fewer.\u003c\/p\u003e\u003ch3\u003eWhich homes it suits\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003e2.5-ton\u003c\/strong\u003e size, or \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, often suits a two-storey cottage, a large bungalow with a finished basement or a wind-exposed house on the outskirts, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. It is a good choice for owners whose priority is heating and who want to reduce the role of electric backup.\u003c\/p\u003e\u003cp\u003eThe examples are only indicative: insulation, windows, airtightness and orientation change the needs from one home to the next. A room-by-room on-site assessment confirms the size before any quote.\u003c\/p\u003e\u003ch3\u003eVariable speed and R-454B refrigerant\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003evariable-speed\u003c\/strong\u003e (\u003cstrong\u003einverter\u003c\/strong\u003e) compressor adjusts its speed to demand. It is what lets the heat pump speed up as the cold intensifies, then slow down when demand drops, instead of switching between off and full power. The house keeps a steady temperature and the system spends most of the year at part load, where its efficiency is at its best.\u003c\/p\u003e\u003cp\u003eThe system runs on \u003cstrong\u003eR-454B\u003c\/strong\u003e, the refrigerant manufacturers have adopted for their new central heat pumps; if it leaks, its effect on global warming is much lower than that of the refrigerant it replaces. It belongs to the A2L class, known as mildly flammable, and its installation follows specific requirements that our refrigeration technicians apply.\u003c\/p\u003e\u003ch3\u003eThe D5FUAA cabinet and the ductwork\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eD5FUAAH30XAK\u003c\/strong\u003e cabinet houses the indoor coil and the blower. It is installed where the old furnace stood and connects to the existing supply plenum and air return. A heat pump delivers air that is less hot than a furnace's, but for longer: the duct system has to keep up. We check the main ducts, branches, registers and air return, and list useful corrections in the quote.\u003c\/p\u003e\u003cp\u003eWe also take care with the cabinet's location in the mechanical room: clear access to the filter and service panels, a condensate drain that flows by gravity whenever possible, and a tight connection to the plenum. These details appear on no certificate, but they are what allow the system to keep its ratings year after year.\u003c\/p\u003e\u003ch3\u003eThe certified ratings, one by one\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e: efficiency over the whole heating season. It is the rating that weighs most on the annual bill of an electrically heated home.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCOP of 2.76 at -8 °C\u003c\/strong\u003e: at that temperature, the heat pump delivers more than two and a half times the heat it uses. An electric baseboard has a COP of 1.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e16.9 SEER2\u003c\/strong\u003e: cooling efficiency over a typical summer.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e11.7 EER2\u003c\/strong\u003e: cooling efficiency at full load, on a hot day.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIndicative LogisVert amount: $2,856\u003c\/h3\u003e\u003cp\u003eOur product sheet shows an indicative \u003cstrong\u003eLogisVert\u003c\/strong\u003e amount of \u003cstrong\u003e$2,856\u003c\/strong\u003e for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. The amount corresponds to the certified pairing of the D5CUHAH30AAK outdoor unit and the D5FUAAH30XAK cabinet.\u003c\/p\u003e\u003cp\u003eWe confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump grant\u003c\/a\u003e summarizes the program's conditions.\u003c\/p\u003e\u003ch2\u003eInstallation by AirGreen\u003c\/h2\u003e\u003ch3\u003eInstallation, step by step\u003c\/h3\u003e\u003col\u003e\u003cli\u003e\u003cstrong\u003eVisit\u003c\/strong\u003e: room-by-room on-site assessment, inspection of the ducts and air return, choice of the outdoor location.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWritten quote\u003c\/strong\u003e: size, backup heat, corrections to the duct system.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eIndoor unit\u003c\/strong\u003e: removal of the furnace, installation of the D5FUAA cabinet, connection to the plenum, air return and condensate drain.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor unit\u003c\/strong\u003e: wall bracket or stand, \u003cstrong\u003eabove the snow line\u003c\/strong\u003e, away from roof drip and, as far as possible, from prevailing winds.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRefrigerant circuit\u003c\/strong\u003e: insulated copper line set, brazing, pressure test and vacuum.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e: \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, outdoor disconnect, thermostat.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e: charge, airflow, defrost, backup heat settings and an explanation of the controls.\u003c\/li\u003e\u003c\/ol\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eA heat pump that heats in deep cold spends a lot of time working in winter; its outdoor unit needs room to breathe. After a storm, clear the snow around the unit and check that no ice is blocking the coil, without ever covering it. Check the cabinet's filter every month in season and replace it according to its format. Annual \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance cleans the coils and checks the condensate drain, the electrical connections and the backup heat. The white vapour the unit releases during defrost is normal.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\u003cp\u003eIt applies to the pairing as installed. Keep the invoice and the commissioning report, which list the serial numbers of both units.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Central Heat Pump ARCOAIRE QuietComfort Compact | 2.5 Tons - 30,000 BTU (Air Handler D5FUAA) - R454B. We assess the home room by room and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797808152868,"sku":"D5CUHAH30AAK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_ARCOAIRE_D5CUHA_2_5_TONNES_30000_BTU_R454B_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082540","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-arcoaire-compact-quiet-comfort-2-5-tonnes-30000-btu-cabinet-d5fuaa-r454b","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}