{"product_id":"thermopompe-centrale-arcoaire-n4h5s-performance-2-tonnes-24000-btu-cabinet-fjma4x-r410a","title":"Central Heat Pump ARCOAIRE N4H5S Performance | 2 Tons - 24,000 BTU (Air Handler FJMA4X) - R410A","description":"\u003ch2\u003eA bungalow with a basement, heated and cooled through its own ducts\u003c\/h2\u003e\u003cp\u003eThe bungalow with a basement is one of the most common homes around \u003cstrong\u003eMontreal\u003c\/strong\u003e, and many already have what a \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e needs: an electric furnace in the basement and a \u003cstrong\u003educt\u003c\/strong\u003e system serving every room on the main floor. The \u003cstrong\u003eCentral Heat Pump ARCOAIRE N4H5S Performance | 2 Tons - 24,000 BTU (Air Handler FJMA4X) - R410A\u003c\/strong\u003e pairs the \u003cstrong\u003eN4H5S24AKAAA\u003c\/strong\u003e outdoor unit with the \u003cstrong\u003eFJMA4X24L0BC\u003c\/strong\u003e cabinet, which takes the place of that furnace and pushes warm or cool air through the existing duct system.\u003c\/p\u003e\u003cp\u003eThe pairing is certified at \u003cstrong\u003e15.2 SEER2\u003c\/strong\u003e, \u003cstrong\u003e12.5 EER2\u003c\/strong\u003e and \u003cstrong\u003e7.5 HSPF2\u003c\/strong\u003e. It handles the cooling of the whole house and most of the heating, with a single thermostat.\u003c\/p\u003e\u003ch3\u003eThe bungalow and its duct system\u003c\/h3\u003e\u003cp\u003eIn a typical bungalow, the duct system starts at the furnace in the basement: a main trunk runs under the floor, between the joists, and branches rise to grilles placed under the main-floor windows. Return air often comes back through one or two large grilles in the hallway or living room. If the basement is finished, a few grilles serve it as well.\u003c\/p\u003e\u003cp\u003eThis duct system was often designed for an electric furnace, which pushes a small amount of very hot air. A heat pump delivers milder air, in larger quantity and for longer. The ducts must therefore let enough air through, especially on the return side. That is the first thing we check during the visit, before we even talk about equipment.\u003c\/p\u003e\u003ch3\u003eWhy 2 tons for this type of home\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003e2-ton\u003c\/strong\u003e size often suits a mid-size bungalow, a semi-detached house or a small two-storey house, when the insulation is reasonable. It is not a rule: a fifties bungalow with poorly insulated walls may need more, and a renovated house with a well-insulated attic may do with the size below.\u003c\/p\u003e\u003cp\u003eWe decide with a room-by-room \u003cstrong\u003eon-site assessment\u003c\/strong\u003e that takes into account wall and attic insulation, windows, orientation and how much of the basement is heated. A properly sized unit runs in long, steady cycles; an oversized one heats in bursts and removes humidity poorly in summer.\u003c\/p\u003e\u003ch3\u003eFrom the old electric furnace to the FJMA4X cabinet\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eFJMA4X24L0BC\u003c\/strong\u003e cabinet is an \u003cstrong\u003eair handler\u003c\/strong\u003e: a casing that contains the heat pump's coil and the blower. It goes where the old furnace stood, connects to the supply plenum and return air, and holds the system filter. Its condensate drain flows to the basement floor drain or to a small pump.\u003c\/p\u003e\u003cp\u003eThe cabinet also houses \u003cstrong\u003ebackup electric heating elements\u003c\/strong\u003e. In a way, they play the role of the old electric furnace, but they only come on when the heat pump is no longer enough. We size them from the on-site assessment and the capacity of the electrical panel.\u003c\/p\u003e\u003ch3\u003eThe heat pump in a few lines\u003c\/h3\u003e\u003cp\u003eA heat pump captures heat from the outdoor air and carries it into the house with the \u003cstrong\u003eR-410A\u003c\/strong\u003e refrigerant. In the outdoor unit, the refrigerant absorbs heat from the air; the compressor concentrates it; in the cabinet, the coil releases it to the air that the blower pushes through the ducts. In summer, the cycle reverses and the heat of the house is released outdoors. Because it moves heat instead of producing it, the heat pump delivers more energy than it uses.\u003c\/p\u003e\u003ch3\u003eWhat the certificate shows\u003c\/h3\u003e\u003cp\u003eThe certificate lists \u003cstrong\u003e14,200 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) and \u003cstrong\u003e11,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 2.06\u003c\/strong\u003e at -15 °C. The two points are measured separately; we report each one as published.\u003c\/p\u003e\u003cp\u003eCompared with the nominal size of 24,000 BTU, the listed capacity represents about 59% at -8 °C and 46% at -15 °C. These figures say two things: the heat pump keeps heating as the cold sets in, more efficiently than an electric furnace; and a growing share of the heating falls to the backup as the temperature keeps dropping.\u003c\/p\u003e\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 210998628\u003c\/strong\u003e, as published in the AHRI certification directory.\u003c\/p\u003e\u003ch3\u003eBackup heat, for the coldest days\u003c\/h3\u003e\u003cp\u003eA conventional heat pump and a Quebec bungalow work as a team: the heat pump heats alone in mild and cool weather, then, when the cold becomes intense, the cabinet's backup elements add to what it supplies. The handover is automatic, through the thermostat, with nothing for you to do.\u003c\/p\u003e\u003cp\u003eThe thermostat must be designed for a heat pump with backup. Properly set, it makes the heat pump work first and limits the use of the backup. We recommend a steady set point rather than deep setbacks at night, since the morning recovery would call on the backup.\u003c\/p\u003e\u003ch3\u003eWhat 15.2 SEER2, 12.5 EER2 and 7.5 HSPF2 mean\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e15.2 SEER2\u003c\/strong\u003e: cooling efficiency over a whole summer. The higher the rating, the less cooling weighs on the bill.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e12.5 EER2\u003c\/strong\u003e: cooling efficiency at full demand, on a very hot day.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e7.5 HSPF2\u003c\/strong\u003e: seasonal heating efficiency, the rating that matters most in Quebec.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCOP of 2.06 at -15 °C\u003c\/strong\u003e: at that temperature, the heat pump delivers about twice the energy it uses; an electric furnace has a COP of 1.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eA drier basement in summer\u003c\/h3\u003e\u003cp\u003eIn summer, the same unit cools the main floor through the existing grilles. The cabinet's coil cools the air and removes humidity, which flows out through the drain. In a bungalow, the effect is also felt downstairs: if the basement is served by the duct system, the air circulating there is dried as well, which limits the damp smell of finished basements.\u003c\/p\u003e\u003cp\u003eIf the basement has few grilles, it stays cooler than the main floor in summer, which is what you want. In winter, it is the opposite: we check that it gets enough air to stay comfortable, especially if it is used as a family room or an office.\u003c\/p\u003e\u003ch3\u003eLogisVert\u003c\/h3\u003e\u003cp\u003eThis pairing does not carry an amount on Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e list of October 19, 2026. If the grant matters for your project, we will point you to an eligible pairing of comparable size.\u003c\/p\u003e\u003ch2\u003eInstallation by AirGreen, from the basement to the backyard\u003c\/h2\u003e\u003ch3\u003eThe job\u003c\/h3\u003e\u003col\u003e\u003cli\u003e\u003cstrong\u003eVisit and needs assessment\u003c\/strong\u003e, inspection of the ducts, return air and electrical panel.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRemoval of the old electric furnace\u003c\/strong\u003e and, where applicable, the old air conditioner, with recovery of the refrigerant.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eInstallation of the FJMA4X cabinet\u003c\/strong\u003e in the same spot, connection to the plenum and return air, condensate drain.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor unit\u003c\/strong\u003e on a stand or wall bracket, above the snow line, away from roof drips and dryer vents.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRefrigerant line\u003c\/strong\u003e in insulated copper, run through the rim joist or the foundation wall, brazing, pressure test and vacuum.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e: \u003cstrong\u003ededicated circuit\u003c\/strong\u003e, outdoor disconnect, power to the backup elements and thermostat.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e: refrigerant charge, airflow, defrost and settings, then an explanation of how everything works.\u003c\/li\u003e\u003c\/ol\u003e\u003ch3\u003eMaintenance and warranty\u003c\/h3\u003e\u003cp\u003eCheck the cabinet filter every month during the heating and cooling seasons, and replace it according to its format. Keep the outdoor unit clear of snow and leaves and do not cover it in winter. Plan annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e of the coils, the condensate drain and the electrical connections. In winter, the white vapour released during defrost is normal.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003eIn a bungalow, a good result depends as much on the ducts as on the equipment; that is why our visit starts with the duct system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Central Heat Pump ARCOAIRE N4H5S Performance | 2 Tons - 24,000 BTU (Air Handler FJMA4X) - R410A. We assess the home room by room and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":67797943517476,"sku":"N4H5S24AKAAA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_ARCOAIRE_N4H5S_2_TONNES_24000_BTU_R410A_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082540","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-arcoaire-n4h5s-performance-2-tonnes-24000-btu-cabinet-fjma4x-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}