{"product_id":"thermopompe-centrale-bosch-ids-inverter-5-tonnes-60000-btu-cabinet-bva-060wn1-m15-r410a","title":"Central Heat Pump BOSCH IDS Inverter | 5 Tons - 60,000 BTU (Air Handler BVA-060WN1-M15) - R410A","description":"\u003ch2\u003eA variable-speed heat pump that keeps up with a very large home, season after season\u003c\/h2\u003e\u003cp\u003eIn a very large home with \u003cstrong\u003eductwork\u003c\/strong\u003e, a \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e handles the cooling and most of the heating through the existing duct system. The \u003cstrong\u003eCentral Heat Pump BOSCH IDS Inverter | 5 Tons - 60,000 BTU (Air Handler BVA-060WN1-M15) - R410A\u003c\/strong\u003e pairs the \u003cstrong\u003eBOVB-060HDN1-M18M\u003c\/strong\u003e outdoor unit with the \u003cstrong\u003eBVA-060WN1-M15\u003c\/strong\u003e indoor unit, an air handler that pushes air through the ducts. Its compressor is \u003cstrong\u003evariable speed\u003c\/strong\u003e (\u003cstrong\u003einverter\u003c\/strong\u003e technology).\u003c\/p\u003e\u003cp\u003eIts ratings are \u003cstrong\u003e15.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10.2 EER2\u003c\/strong\u003e and \u003cstrong\u003e8.4 HSPF2\u003c\/strong\u003e. This page explains what variable speed brings to this size, what the certificate publishes for winter and what the installation requires.\u003c\/p\u003e\u003ch3\u003eWhat variable speed changes\u003c\/h3\u003e\u003cp\u003eA conventional compressor runs at full output or not at all: it starts, reaches the setpoint, stops, then starts again. The \u003cstrong\u003einverter\u003c\/strong\u003e compressor of the Bosch IDS system instead adjusts its speed to actual demand. In mild weather, it runs slowly and for a long time; when the cold or heat intensifies, it speeds up.\u003c\/p\u003e\u003cp\u003eThe result is felt in steadiness: fewer starts, more stable temperatures from one room to the next and air that circulates more continuously through the \u003cstrong\u003educts\u003c\/strong\u003e. The system runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e; a reversing valve lets it heat in winter and cool in summer.\u003c\/p\u003e\u003cp\u003eFewer starts also means less strain on the components. A compressor that starts and stops constantly works under the most demanding conditions; a compressor that slows down and keeps running works more gently and steadily.\u003c\/p\u003e\u003ch3\u003eFive tons, but rarely at full output\u003c\/h3\u003e\u003cp\u003eA \u003cstrong\u003e5-ton\u003c\/strong\u003e system is chosen to cover the most demanding days of the year. Most of the time, though, the house needs much less: cool fall nights, mild spring days, temperate summer evenings. That is where variable speed makes the difference. Instead of piling up short cycles, the compressor slows down and keeps running.\u003c\/p\u003e\u003cp\u003eIn a large home, this continuous operation also helps keep temperatures even between the basement, the main floor and the upper floor, because the air never stops circulating for long.\u003c\/p\u003e\u003ch3\u003eWhat the certificate shows\u003c\/h3\u003e\u003cp\u003eThe certificate lists \u003cstrong\u003e40,500 BTU\/h at -8 °C\u003c\/strong\u003e (17 °F) and \u003cstrong\u003e35,000 BTU\/h at -15 °C\u003c\/strong\u003e (5 °F), with a \u003cstrong\u003eCOP of 1.86\u003c\/strong\u003e at the -15 °C point. The two points are measured separately; we report each one as published, without extrapolating.\u003c\/p\u003e\u003cp\u003eThese figures come from certificate \u003cstrong\u003eAHRI 206395998\u003c\/strong\u003e, as published in the AHRI certification directory, for the pairing of the \u003cstrong\u003eBOVB-060HDN1-M18M\u003c\/strong\u003e outdoor unit and the \u003cstrong\u003eBVA-060WN1-M15\u003c\/strong\u003e indoor unit.\u003c\/p\u003e\u003ch3\u003eWhat the winter points mean\u003c\/h3\u003e\u003cp\u003eAt -8 °C, the listed capacity represents about 68% of the 60,000 BTU nominal size; at -15 °C, about 58%. The heat pump therefore keeps a good share of its capacity when the cold sets in, which reduces the share of heat the backup has to provide.\u003c\/p\u003e\u003cp\u003eThis pairing is not, however, listed as a cold-climate heat pump. During deep cold, the demand of a very large home can exceed what the outdoor unit delivers: the air handler's \u003cstrong\u003ebackup heat\u003c\/strong\u003e, or the existing furnace in an installation that keeps it, then supplements the heat. We size it according to the load calculation and the certificate points.\u003c\/p\u003e\u003cp\u003eTo get the most out of variable speed, keep a steady setpoint rather than large nighttime setbacks. The system can then stay at low speed instead of recovering several degrees in the morning, which calls less on the backup heat.\u003c\/p\u003e\u003ch3\u003eReading the heating ratings\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHSPF2 (8.4)\u003c\/strong\u003e: seasonal heating efficiency over a typical winter. It is the most telling rating for a home that is heated for a good part of the year.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCOP (1.86 at -15 °C)\u003c\/strong\u003e: the heat delivered divided by the electricity consumed, at that temperature. An electric baseboard has a COP of 1; at this point, the heat pump delivers nearly twice the energy it consumes.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThese two pieces of information are read together. At -15 °C, the heat pump still delivers substantial capacity with a COP above 1: every part of the heat it supplies at that moment does not have to come from the electric backup, whose COP is 1.\u003c\/p\u003e\u003ch3\u003eCooling and dehumidification\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eSEER2 of 15.0\u003c\/strong\u003e measures seasonal cooling efficiency over a typical summer; the \u003cstrong\u003eEER2 of 10.2\u003c\/strong\u003e measures efficiency on a hot day, at full demand. As in heating, variable speed lets the system run slowly most of the time and speed up during heat waves.\u003c\/p\u003e\u003cp\u003eThese long, low-speed cycles give the air time to pass over the cold coil, which removes moisture; the water drains through the condensate drain. The house stays cool and dry, even in muggy weather, all the way to the upstairs bedrooms.\u003c\/p\u003e\u003ch3\u003eHomes suited to the 5-ton size\u003c\/h3\u003e\u003cp\u003eThis size typically targets very large homes with ducts: two spacious levels with a fully finished basement, a very spread-out single-storey home with large glazed areas, or a home enlarged several times. These are typical examples.\u003c\/p\u003e\u003cp\u003eVariable speed does not replace proper sizing. The room-by-room load calculation confirms the size based on insulation, windows and airtightness; if it points to another size, we recommend it.\u003c\/p\u003e\u003ch3\u003eLogisVert\u003c\/h3\u003e\u003cp\u003eThis pairing does not carry an amount on Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e list of October 19, 2026. If the grant matters for your project, we will point you to an eligible pairing of comparable size.\u003c\/p\u003e\u003ch2\u003eInstallation in a ducted home\u003c\/h2\u003e\u003cp\u003eThe indoor unit takes the place of the old furnace or air handler and connects to the existing \u003cstrong\u003educt system\u003c\/strong\u003e. Before the quote, we check duct sizes and the air return, because a variable-speed heat pump only delivers its full efficiency if the airflow keeps up. The outdoor unit goes on a stand, above the snow line, on a \u003cstrong\u003ededicated circuit\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eA duct system ready for a large system\u003c\/h3\u003e\u003cp\u003eAt low speed, the system moves little air; on high-demand days, it moves a lot. The duct system must let that maximum airflow through without choking it, otherwise the capacity delivered drops and the registers become noisy. A large home often needs air returns on each level. We measure the duct system during the visit and list the corrections in the quote.\u003c\/p\u003e\u003ch3\u003eElectrical, backup heat and commissioning\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e: dedicated circuit for the heat pump, supply for the backup heat and a check of the panel's capacity during the visit.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor unit\u003c\/strong\u003e: solid stand above the snow line, away from snow sliding off the roof, with clear access for maintenance.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e: insulated, evacuated and checked before the refrigerant is released; condensate drain connected to a compliant discharge point.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCommissioning\u003c\/strong\u003e: charge, temperatures, airflow, controls and thermostat, then an explanation of the settings.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eReplace the system filter according to its format, keep the outdoor unit clear of snow and leaves, and plan annual \u003cstrong\u003eHVAC\u003c\/strong\u003e maintenance of the coil, condensate drain and electrical connections. In winter, white vapour during defrost is normal. Because the system runs for long periods, a lot of air passes through the filter: check it regularly.\u003c\/p\u003e\u003ch3\u003eAirGreen, for the life of the installation\u003c\/h3\u003e\u003cp\u003eA family business active for more than fifteen years in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we hold RBQ licences for ventilation, refrigeration and electrical work and carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, the quote is in writing, and our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing options\u003c\/a\u003e let you choose the right unit rather than the cheapest one.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Central Heat Pump BOSCH IDS Inverter | 5 Tons - 60,000 BTU (Air Handler BVA-060WN1-M15) - R410A. We assess the home room by room and confirm the right size and your grant eligibility before signing.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Bosch","offers":[{"title":"Default Title","offer_id":67797962817828,"sku":"BOVB-060HDN1-M18M","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_BOSCH_IDS_5_TONNES_60000_BTU_R410A_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD.png?v=1793082547","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-bosch-ids-inverter-5-tonnes-60000-btu-cabinet-bva-060wn1-m15-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}