{"product_id":"thermopompe-centrale-kinghome-ultranixx-r32-3-tonnes-36000-btu-serpentin-a-coil","title":"KINGHOME Ultranixx R32 Central Heat Pump | 3 Tons - 36,000 BTU | A-Coil","description":"\u003ch2\u003eYour central air conditioner has died, but your gas furnace is still good\u003c\/h2\u003e\n\u003cp\u003eIt's the call we get most often in early summer, from \u003cstrong\u003eLaval\u003c\/strong\u003e to the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e: a cottage's central air conditioner won't start anymore, while the gas furnace in the basement is about ten years younger and works perfectly. Replacing the air conditioner with another air conditioner takes care of summer. Replacing it with a \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e takes care of summer and cuts gas consumption for the rest of the year. This \u003cstrong\u003e3-ton\u003c\/strong\u003e Ultranixx system, the KU36UXO outdoor unit and the KCAC36FI A-coil, certified together under \u003cstrong\u003eAHRI 217603525\u003c\/strong\u003e, is designed for exactly this replacement.\u003c\/p\u003e\n\n\u003ch3\u003eWhat changes compared with a plain air conditioner\u003c\/h3\u003e\n\u003cp\u003eOn paper, the installation looks like an air conditioner's: a coil on the furnace, a refrigerant line set, an outdoor unit. In practice, three differences matter.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe outdoor unit works in winter.\u003c\/strong\u003e It has to sit above the snow, on a bracket or a pad, and the defrost water has to drain without forming ice under the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe coil also becomes a condenser.\u003c\/strong\u003e In heating mode, hot refrigerant flows through the coil sitting on the furnace. The furnace and the heat pump must never heat at the same time, and the control wiring takes that into account.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe furnace gets new signals.\u003c\/strong\u003e During the outdoor unit's defrost cycle, the control sends a signal to the furnace so it doesn't blow cold air into the house. The coil's leak sensor is also wired to the furnace.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe result is a \u003cstrong\u003edual-energy\u003c\/strong\u003e system: the heat pump handles the heating for most of the season and the gas furnace takes over at the changeover point set during commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eCold-weather capacities\u003c\/h3\u003e\n\u003cp\u003eThe system is certified at \u003cstrong\u003e16 SEER2\u003c\/strong\u003e, \u003cstrong\u003e8.5 HSPF2\u003c\/strong\u003e and an \u003cstrong\u003eEER2 of 11\u003c\/strong\u003e. The heating capacities listed on NEEP (AHRI No. 217603525) are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: 26,000 BTU\/h, with a COP of 2.0\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e32,000 BTU\/h\u003c\/strong\u003e, with a COP of 1.8\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: 19,600 BTU\/h, with a COP of 1.21\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt -15 °C, the pairing delivers 89% of its 36,000 BTU\/h nominal capacity. At -30 °C, it still heats with a COP above 1. In a dual-energy installation, these figures are used to set the changeover point: as long as the heat pump covers the house's load with a good COP, the furnace stays off. The value at -15 °C is higher than the one at -8.3 °C, as shown on the certificate; that's how the inverter compressor was measured at each test point. The heating range goes down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the system carries the ENERGY STAR \u003cstrong\u003ecold climate\u003c\/strong\u003e designation (ID 4497871).\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace fan, the centrepiece of the system\u003c\/h3\u003e\n\u003cp\u003eWith an A-coil, there's no fan in the heat pump's indoor unit: the furnace fan is what moves the air. Its speed has to be set for the airflow a three-ton coil requires, in cooling as well as in heating. A fan set too low means a coil that freezes in summer and reduced capacity in winter. With R-32, the standard also requires a minimum airflow if a leak is detected; we check that the furnace can deliver it.\u003c\/p\u003e\n\n\u003ch3\u003eThe KCAC36FI coil\u003c\/h3\u003e\n\u003cp\u003eThe coil measures \u003cstrong\u003e17.50 x 21.25 x 23.00 inches\u003c\/strong\u003e. It connects to the furnace's air outlet and can also be installed horizontally; its electrical box can be moved to suit the available space. It includes an electronic expansion valve, a primary drain pan, a secondary pan and a refrigerant leak sensor. Wi-Fi is available as an option. The outdoor unit's twin-cylinder rotary compressor modulates its speed, which lengthens the cycles and improves dehumidification compared with a basic air conditioner.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we check before the installation\u003c\/h2\u003e\n\u003cp\u003eDuring a visit in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we confirm these points before giving you a quote.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace\u003c\/h3\u003e\n\u003cp\u003eWe look at its age, the condition of the heat exchanger, the fan motor and the dimensions of its air outlet. If the furnace has less fan capacity than the coil requires, or if it's nearing the end of its life, we recommend the air handler version of the same series instead.\u003c\/p\u003e\n\n\u003ch3\u003eThe filter and the return air\u003c\/h3\u003e\n\u003cp\u003eEvery installation must include a filter on the return air, at the coil or at the return grille. We plan an accessible location, because a filter that never gets changed reduces the airflow, makes the coil freeze in summer and lowers the heating capacity in winter.\u003c\/p\u003e\n\u003ch3\u003eThe power supply\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires a single-phase \u003cstrong\u003e220 V\u003c\/strong\u003e supply, an \u003cstrong\u003eMCA of 28 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum overcurrent protection (MOP) of 30 A\u003c\/strong\u003e. We check whether the old air conditioner's circuit matches these values, which isn't always the case.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor unit location\u003c\/h3\u003e\n\u003cp\u003eThe KU36UXO unit measures \u003cstrong\u003e39.00 x 14.56 x 37.81 inches\u003c\/strong\u003e and its published sound level is \u003cstrong\u003e60 dB(A)\u003c\/strong\u003e. We often move it from where the old air conditioner stood, to keep it above the snow and out of the path of ice falling from the roof.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping and the drain\u003c\/h3\u003e\n\u003cp\u003eThe connections are \u003cstrong\u003e3\/8 and 3\/4 inch\u003c\/strong\u003e. The old air conditioner's line set is only reused if its diameter and condition allow it, after cleaning. The drain gets a trap and a continuous slope, and the secondary pan is connected when required.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eThis system has an \u003cstrong\u003eindicative LogisVert amount of $3,120\u003c\/strong\u003e, calculated using the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217603525 and ENERGY STAR ID 4497871.\u003c\/p\u003e\n\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians who handle the connection, the furnace wiring and the commissioning.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration handled by us.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service for maintenance and seasonal adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate for the 3-ton Ultranixx with A-coil: we check your furnace, your panel and your existing line set, then give you a precise quote.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_KCAC36FI_KU36UXO_FICHE_TECHNIQUE_EN_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKCAC36FI + KU36UXO spec sheet (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_UNITE_EXTERIEURE_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx outdoor unit manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_SERPENTIN_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx coil manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959644422436,"sku":"KU36UXO-KCAC36FI","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_CENTRALE_KINGHOME_ULTRANIXX_R32_3_TONNES_36000_BTU_SERPENTIN_A_COIL_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291368","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-kinghome-ultranixx-r32-3-tonnes-36000-btu-serpentin-a-coil","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}