{"product_id":"thermopompe-centrale-kinghome-ultranixx-r32-4-tonnes-48000-btu-ventilo-convecteur","title":"KINGHOME Ultranixx R32 Central Heat Pump | 4 Tons - 48,000 BTU | Air Handler","description":"\u003ch2\u003eFor a large house where cooling matters as much as heating\u003c\/h2\u003e\n\u003cp\u003eA good-sized house, often renovated into an open-concept layout with large south- or west-facing windows, has two needs that pull in opposite directions: lots of heat in January and lots of cooling in July. This \u003cstrong\u003e4-ton\u003c\/strong\u003e Ultranixx pairing, made up of the KU60UXO outdoor unit and the KD48UXI air handler, certified together under \u003cstrong\u003eAHRI 217194946\u003c\/strong\u003e, is the most efficient in the series for cooling. It's the \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e we recommend when the house has ductwork, the existing furnace has to come out and summer comfort matters as much as winter comfort.\u003c\/p\u003e\n\n\u003ch3\u003e19 SEER2: the best cooling rating in the series\u003c\/h3\u003e\n\u003cp\u003eThe system is certified at \u003cstrong\u003e19 SEER2\u003c\/strong\u003e, with an \u003cstrong\u003eEER2 of 11.7\u003c\/strong\u003e and \u003cstrong\u003e10 HSPF2\u003c\/strong\u003e. SEER2 measures seasonal energy use in cooling; in a house with a lot of glass, it's the rating that determines the summer bill. EER2 measures efficiency in high heat, when the whole street is running its air conditioners. The inverter compressor modulates its speed and avoids the repeated starts that wear out a basic unit and leave the air humid.\u003c\/p\u003e\n\u003cp\u003eIn cooling mode, the KD48UXI removes up to \u003cstrong\u003e8.49 pints of moisture per hour\u003c\/strong\u003e. In an open-concept space where the kitchen, dining room and living room share the same volume of air, this dehumidification capacity prevents the cold, clammy feeling that oversized units create.\u003c\/p\u003e\n\n\u003ch3\u003eHeating in extreme cold\u003c\/h3\u003e\n\u003cp\u003eThe system's heating capacities listed on NEEP (AHRI No. 217194946) are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: 39,500 BTU\/h, with a COP of 2.86\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e48,000 BTU\/h\u003c\/strong\u003e, with a COP of 2.0\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: 26,200 BTU\/h, with a COP of 1.25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe COP of 2.86 at -8.3 °C is the highest of the Ultranixx air handler pairings: at that temperature, very common in a \u003cstrong\u003eMontréal\u003c\/strong\u003e winter, the unit produces nearly three times more heat than the electricity it uses. At -15 °C, it delivers 100% of its 48,000 BTU\/h nominal capacity. At -30 °C, it still provides 55%, and the optional backup heater makes up the rest when the on-site assessment of heating needs calls for it. The heating range goes down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the system carries the ENERGY STAR \u003cstrong\u003ecold climate\u003c\/strong\u003e designation (ID 4011419). As with the whole series, the value at -15 °C is higher than the one at -8.3 °C: these are the figures as certified.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow to match the house\u003c\/h3\u003e\n\u003cp\u003eThe air handler moves up to \u003cstrong\u003e1,200 CFM\u003c\/strong\u003e. That kind of airflow calls for a serious duct system: a plenum with a good cross-section, return air in the main rooms and branches that aren't crushed between the joists. In a house that's been extended over the years, it sometimes turns out the original ductwork was never adapted to the addition. We measure it before installing a unit of this capacity. The cabinet, at \u003cstrong\u003e24.81 x 21.25 x 52.00 inches\u003c\/strong\u003e, can be installed in a vertical or horizontal position, and it has a built-in refrigerant leak sensor.\u003c\/p\u003e\n\n\u003ch3\u003eA vertical outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe KU60UXO has a tall, narrow format: \u003cstrong\u003e35.44 x 13.38 x 49.63 inches\u003c\/strong\u003e. Its shallow depth makes it easy to install along a side wall, where a wide unit would block the passage between two houses. The published sound level is \u003cstrong\u003e62 dB(A)\u003c\/strong\u003e outdoors and \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e indoors. The units communicate over a two- or four-wire digital bus, and they're compatible with conventional low-voltage thermostats; Wi-Fi is available as an option. The refrigerant is \u003cstrong\u003eR-32\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we check before installation\u003c\/h2\u003e\n\u003cp\u003eOn a house this size, the on-site assessment makes all the difference. Here is what we validate during a visit in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e or in \u003cstrong\u003eMontréal\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eElectrical capacity\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires a \u003cstrong\u003e220 V\u003c\/strong\u003e single-phase supply, an \u003cstrong\u003eMCA of 39 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum overcurrent protection (MOP) of 45 A\u003c\/strong\u003e. The air handler has its own circuit, and a high-capacity backup heater can add a considerable load. In a large house that already has an EV charger, a spa or a full electric kitchen, we do a load calculation on the electrical panel before confirming. If the electrical service needs to be upgraded, the quote says so clearly.\u003c\/p\u003e\n\n\u003ch3\u003eThe on-site assessment of heating and cooling needs\u003c\/h3\u003e\n\u003cp\u003eWe assess heating and cooling needs on site, room by room, paying particular attention to the windows. A house with a lot of west-facing windows can need four tons for cooling while heating alone would need less. We choose the capacity based on the more demanding need, without oversizing.\u003c\/p\u003e\n\n\u003ch3\u003eOutdoor unit location\u003c\/h3\u003e\n\u003cp\u003eWe set the unit on a stand or pad that keeps it above the snow and lets defrost water drain away. The vertical format of the KU60UXO often allows it to go in a narrow side yard, but the manufacturer's clearances and the municipal bylaws on distance from property lines have to be respected.\u003c\/p\u003e\n\n\u003ch3\u003ePiping and drain\u003c\/h3\u003e\n\u003cp\u003eThe connections are \u003cstrong\u003e3\/8 and 3\/4 inch\u003c\/strong\u003e. The air handler's condensate drain gets a trap and a continuous slope; in the horizontal position, a secondary drain pan is added. The vacuum is completed before commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eThis system has an \u003cstrong\u003eindicative LogisVert amount of $4,740\u003c\/strong\u003e, calculated according to the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217194946 and ENERGY STAR ID 4011419.\u003c\/p\u003e\n\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians, with no improvised subcontracting.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration done by us at commissioning.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service for seasonal maintenance and follow-ups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the 4-ton Ultranixx with air handler: we assess your house, your panel and your ducts, then give you an accurate quote.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_KD48UXI_KU60UXO_FICHE_TECHNIQUE_EN_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKD48UXI + KU60UXO spec sheet (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_UNITE_EXTERIEURE_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx outdoor unit manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_VENTILO_CONVECTEUR_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx air handler manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959644061988,"sku":"KU60UXO-KD48UXI","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_CENTRALE_KINGHOME_ULTRANIXX_R32_4_TONNES_48000_BTU_VENTILO_CONVECTEUR_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291367","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-kinghome-ultranixx-r32-4-tonnes-48000-btu-ventilo-convecteur","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}