{"product_id":"thermopompe-centrale-kinghome-ultranixx-r32-5-tonnes-60000-btu-serpentin-a-coil","title":"KINGHOME Ultranixx R32 Central Heat Pump | 5 Tons - 60,000 BTU | A-Coil","description":"\u003ch2\u003eA high-capacity heat pump on the furnace of a large house\u003c\/h2\u003e\n\u003cp\u003eLarge houses heated with natural gas often have a high-capacity furnace, installed a few years ago, and a central air conditioner that struggles to cool the upper floor in July. When the air conditioner reaches the end of its life, replacing it with a \u003cstrong\u003e5-ton\u003c\/strong\u003e \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e turns the installation into a \u003cstrong\u003edual-energy\u003c\/strong\u003e system: the heat pump heats and cools, and the furnace is only used as backup. This Ultranixx system, the KU60UXO outdoor unit paired with the KCAC60HI A-coil, certified together under \u003cstrong\u003eAHRI 217603526\u003c\/strong\u003e, is the largest capacity offered in the coil version.\u003c\/p\u003e\n\n\u003ch3\u003eThe capacities and what they make possible\u003c\/h3\u003e\n\u003cp\u003eThe system is certified at \u003cstrong\u003e16 SEER2\u003c\/strong\u003e, \u003cstrong\u003e9 HSPF2\u003c\/strong\u003e and an \u003cstrong\u003eEER2 of 9.8\u003c\/strong\u003e. The heating capacities listed on NEEP (AHRI No. 217603526) are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: 41,000 BTU\/h, with a COP of 2.34\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e54,000 BTU\/h\u003c\/strong\u003e, with a COP of 1.8\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: 24,900 BTU\/h, with a COP of 1.14\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt -15 °C, the heat pump delivers 90% of its 60,000 BTU\/h nominal capacity. That's enough to heat a large, well-insulated house on its own for most of the winter. At -30 °C, the capacity drops by more than half, and that's exactly where the furnace takes over again. The changeover point is set at commissioning, based on the on-site assessment of heating needs. The value at -15 °C is higher than the one at -8.3 °C, as shown on the certificate. The heating range goes down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the system carries the ENERGY STAR \u003cstrong\u003ecold climate\u003c\/strong\u003e designation (ID 4657195).\u003c\/p\u003e\n\u003cp\u003eThe 9.8 EER2 is lower than that of the smaller pairings. It measures efficiency in very hot weather, a condition that represents only a small share of cooling hours in Québec. The SEER2 of 16, which covers the whole season, is still the rating to look at for your summer bill.\u003c\/p\u003e\n\n\u003ch3\u003eWhy keep the furnace in a large house\u003c\/h3\u003e\n\u003cp\u003eA large all-electric house would need a high-capacity backup heating element for the coldest nights, along with the electrical service that goes with it. By keeping the gas furnace for those few periods, you often avoid a panel upgrade, while shifting most of the season's heating hours to electricity.\u003c\/p\u003e\n\u003ch3\u003eThe KCAC60HI coil and the space in the basement\u003c\/h3\u003e\n\u003cp\u003eThe coil measures \u003cstrong\u003e24.50 x 21.25 x 28.50 inches\u003c\/strong\u003e. Its width matches high-capacity furnaces, and its height adds to the furnace's height under the supply plenum. In a basement with a low ceiling, or when the plenum runs straight to the joists, this height has to be checked before the installation is confirmed: the transition between the furnace and the duct network sometimes has to be redone. The coil can also be installed horizontally, and its control box can be moved to suit the available space.\u003c\/p\u003e\n\u003cp\u003eIt includes an electronic expansion valve, a primary drain pan, a secondary pan and a refrigerant leak sensor. The system runs on \u003cstrong\u003eR-32\u003c\/strong\u003e, whose global warming potential is much lower than that of R-410A.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow that depends on the furnace\u003c\/h3\u003e\n\u003cp\u003eWith a five-ton coil, the furnace fan has to move a large volume of air. A high-capacity furnace can generally do it, as long as its speed is set for the coil and not left at the factory setting meant for gas heating. The duct network, for its part, has to handle this airflow without the static pressure climbing to the point where the fan strains. We measure it on site.\u003c\/p\u003e\n\n\u003ch3\u003eFull dual-energy integration\u003c\/h3\u003e\n\u003cp\u003eThe wiring connects the outdoor unit, the coil, the thermostat and the furnace. The heat pump and the furnace never heat at the same time. During defrost, a signal is sent to the furnace to avoid cold air in the ducts. If there's a refrigerant leak, the outdoor unit shuts down, the gas valve is closed and the fan switches to high speed. The twin-cylinder inverter compressor modulates its speed based on demand. Wi-Fi is available as an option.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we check before the installation\u003c\/h2\u003e\n\u003cp\u003eDuring a visit in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, we confirm these points before giving you a quote.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace and the clearance\u003c\/h3\u003e\n\u003cp\u003eAge, condition of the heat exchanger, fan capacity, width of the air outlet and clear height under the ceiling: these factors decide whether the coil goes on directly or an adaptation is needed. A furnace at the end of its life is better replaced with the air handler version of the same series.\u003c\/p\u003e\n\n\u003ch3\u003eThe power supply\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires a single-phase \u003cstrong\u003e220 V\u003c\/strong\u003e supply, an \u003cstrong\u003eMCA of 39 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum overcurrent protection (MOP) of 45 A\u003c\/strong\u003e. The circuit of an old five-ton air conditioner can sometimes be reused, but we check the wire gauge, the breaker and the remaining capacity of the panel.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor unit location\u003c\/h3\u003e\n\u003cp\u003eThe KU60UXO unit has a vertical format of \u003cstrong\u003e35.44 x 13.38 x 49.63 inches\u003c\/strong\u003e and a published sound level of \u003cstrong\u003e62 dB(A)\u003c\/strong\u003e. It has to stay above the snow, on a bracket or a pad that lets the defrost water drain, and a good distance from bedroom windows, yours as well as your neighbour's.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping and the drain\u003c\/h3\u003e\n\u003cp\u003eThe connections are \u003cstrong\u003e3\/8 and 3\/4 inch\u003c\/strong\u003e. The old air conditioner's line set is only reused if its diameter and condition allow it. The drain gets a trap and a continuous slope, and the secondary pan is connected when required.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eThis system has an \u003cstrong\u003eindicative LogisVert amount of $4,920\u003c\/strong\u003e, calculated using the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217603526 and ENERGY STAR ID 4657195.\u003c\/p\u003e\n\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians who handle the furnace integration from start to finish.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration handled by us.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service for maintenance and changeover point adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate for the 5-ton Ultranixx with A-coil: we check your furnace, the available space and your panel, then give you a detailed quote.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_KCAC60HI_KU60UXO_FICHE_TECHNIQUE_EN_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKCAC60HI + KU60UXO spec sheet (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_UNITE_EXTERIEURE_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx outdoor unit manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_SERPENTIN_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx coil manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959644487972,"sku":"KU60UXO-KCAC60HI","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_CENTRALE_KINGHOME_ULTRANIXX_R32_5_TONNES_60000_BTU_SERPENTIN_A_COIL_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291367","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-kinghome-ultranixx-r32-5-tonnes-60000-btu-serpentin-a-coil","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}