{"product_id":"thermopompe-centrale-kinghome-ultranixx-r32-5-tonnes-60000-btu-ventilo-convecteur","title":"KINGHOME Ultranixx R32 Central Heat Pump | 5 Tons - 60,000 BTU | Air Handler","description":"\u003ch2\u003eThe highest capacity in the series for large houses\u003c\/h2\u003e\n\u003cp\u003eA house with three living levels, a fully finished basement, an intergenerational home or a nineties build with an addition at the back: these buildings often go beyond what a central system of ordinary size can heat in very cold weather. This \u003cstrong\u003e5-ton\u003c\/strong\u003e Ultranixx pairing, the KU60UXO outdoor unit with the KD60UXI air handler, certified together under \u003cstrong\u003eAHRI 217194947\u003c\/strong\u003e, is the most powerful \u003cstrong\u003ecentral heat pump\u003c\/strong\u003e in the series and the one with the best seasonal heating efficiency.\u003c\/p\u003e\n\u003cp\u003eIt replaces a furnace and a central air conditioner with a single system that uses the existing ductwork. In a large house, this choice avoids installing two separate units and doubling up on maintenance, as long as the duct network can distribute that much airflow.\u003c\/p\u003e\n\n\u003ch3\u003e10.5 HSPF2: the highest heating rating in the series\u003c\/h3\u003e\n\u003cp\u003eThe system is certified at \u003cstrong\u003e10.5 HSPF2\u003c\/strong\u003e, \u003cstrong\u003e18.2 SEER2\u003c\/strong\u003e and an \u003cstrong\u003eEER2 of 11.2\u003c\/strong\u003e. HSPF2 measures seasonal heating efficiency; in a large house in Québec, it's the rating that weighs most on the annual bill. The cold-weather capacities listed on NEEP (AHRI No. 217194947) are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8.3 °C\u003c\/strong\u003e: 45,000 BTU\/h, with a COP of 2.66\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e54,000 BTU\/h\u003c\/strong\u003e, with a COP of 2.1\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-30 °C\u003c\/strong\u003e: 27,000 BTU\/h, with a COP of 1.27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe COP of 2.1 at -15 °C is the highest of the Ultranixx pairings at that test point. At -15 °C, the system delivers 90% of its 60,000 BTU\/h nominal capacity; at -30 °C, it delivers 45%, with a COP still above 1. In a large house, that last figure matters for sizing the backup heat: the air handler's optional electric heating element takes over during the few coldest nights of winter, and the on-site assessment of heating needs determines its capacity. The heating range goes down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the system carries the ENERGY STAR \u003cstrong\u003ecold climate\u003c\/strong\u003e designation (ID 4011420).\u003c\/p\u003e\n\n\u003ch3\u003e1,500 CFM: an airflow that calls for good ductwork\u003c\/h3\u003e\n\u003cp\u003eThe KD60UXI air handler moves up to \u003cstrong\u003e1,500 CFM\u003c\/strong\u003e. That's the airflow of a large furnace, and it takes ductwork to match: a supply plenum with enough cross-section, unobstructed branches and, above all, enough return air grilles. A network that's too restrictive drives up the static pressure: the fan strains, the noise goes up and the delivered capacity goes down. We measure the static pressure before recommending this size. When the network can't keep up and fixing it would cost too much, we tell you so, and we suggest a split approach, for example a smaller central system paired with a \u003cstrong\u003emulti-zone heat pump\u003c\/strong\u003e for the upper floor or the addition.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures \u003cstrong\u003e24.81 x 21.25 x 52.00 inches\u003c\/strong\u003e, installs vertically or horizontally and has a built-in refrigerant leak sensor. In cooling mode, it removes up to \u003cstrong\u003e9.38 pints of moisture per hour\u003c\/strong\u003e, the highest dehumidification capacity of the air handlers in the series, which is useful in a finished basement with a home theatre or a gym.\u003c\/p\u003e\n\n\u003ch3\u003eOutdoor unit, refrigerant and controls\u003c\/h3\u003e\n\u003cp\u003eThe KU60UXO outdoor unit has a vertical format of \u003cstrong\u003e35.44 x 13.38 x 49.63 inches\u003c\/strong\u003e, which is easier to fit in a side yard than a wide unit. The published sound level is \u003cstrong\u003e63 dB(A)\u003c\/strong\u003e outdoors and \u003cstrong\u003e54 dB(A)\u003c\/strong\u003e indoors. The system runs on \u003cstrong\u003eR-32\u003c\/strong\u003e. Its inverter-driven twin-cylinder rotary compressor modulates its speed based on the load: on a mild fall day, it runs at low speed rather than starting and stopping over and over. The units communicate through a two- or four-wire digital bus, compatible with conventional low-voltage thermostats. Wi-Fi is available as an option.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we check before the installation\u003c\/h2\u003e\n\u003cp\u003eA system of this capacity isn't sold on square footage alone. Here's what we confirm during a visit in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe on-site assessment of heating needs\u003c\/h3\u003e\n\u003cp\u003eWe do an on-site assessment of heating and cooling needs, room by room. A large, well-insulated house may do just fine with four tons; we only recommend five tons if this assessment justifies it. An oversized unit costs more to buy, dehumidifies poorly in summer and runs in short cycles.\u003c\/p\u003e\n\n\u003ch3\u003eElectrical capacity\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires a single-phase \u003cstrong\u003e220 V\u003c\/strong\u003e supply, an \u003cstrong\u003eMCA of 39 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum overcurrent protection (MOP) of 45 A\u003c\/strong\u003e. The air handler has its own circuit, and the backup heating element alone can take up a large share of the electrical service. In a large house, we always do the electrical panel load calculation, taking into account the EV charger, the pool or the spa.\u003c\/p\u003e\n\n\u003ch3\u003eThe outdoor unit location\u003c\/h3\u003e\n\u003cp\u003eWe set the unit on a bracket or a pad that keeps it above the snow and lets the defrost water drain, away from roof overhangs and bedroom windows. The manufacturer's clearances and the municipal by-laws on the distance from property lines are checked before the quote.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping and the drain\u003c\/h3\u003e\n\u003cp\u003eThe refrigerant connections are \u003cstrong\u003e3\/8 and 3\/4 inch\u003c\/strong\u003e. The condensate drain gets a trap and a continuous slope; in a horizontal installation, a secondary pan is added. The vacuum is completed before commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert assistance\u003c\/h3\u003e\n\u003cp\u003eThis system has an \u003cstrong\u003eindicative LogisVert amount of $5,400\u003c\/strong\u003e, the highest in the Ultranixx series, calculated using the LogisVert rule ($120 per 1,000 BTU\/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The file references are AHRI 217194947 and ENERGY STAR ID 4011420.\u003c\/p\u003e\n\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSalaried refrigeration technicians who do the connection and commissioning themselves.\u003c\/li\u003e\n\u003cli\u003eCivil liability insurance of \u003cstrong\u003e$5,000,000\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eWarranty registration handled by us.\u003c\/li\u003e\n\u003cli\u003eAfter-sales service for maintenance and seasonal follow-ups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate for the 5-ton Ultranixx with air handler: we do the on-site assessment of heating needs, measure your ducts and check your panel before giving you a quote.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_KD60UXI_KU60UXO_FICHE_TECHNIQUE_EN_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKD60UXI + KU60UXO spec sheet (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_UNITE_EXTERIEURE_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx outdoor unit manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOME_ULTRANIXX_MANUEL_VENTILO_CONVECTEUR_FR_AIRGREEN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUltranixx air handler manual (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.\u003c\/p\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":67959644094756,"sku":"KU60UXO-KD60UXI","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_CENTRALE_KINGHOME_ULTRANIXX_R32_5_TONNES_60000_BTU_VENTILO_CONVECTEUR_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793291367","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-centrale-kinghome-ultranixx-r32-5-tonnes-60000-btu-ventilo-convecteur","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}