{"product_id":"thermopompe-conduits-gainables-forestair-e24-18000-btu-montreal-monteregie","title":"FORESTAiR E24 Ducted Heat Pump | 18000 BTU | Montreal \u0026 Montérégie","description":"\u003ch2 data-section-id=\"1qsdu0q\" data-start=\"101\" data-end=\"187\"\u003eA discreet and high-performance ducted solution for residential comfort in Quebec\u003c\/h2\u003e\n\u003cp data-start=\"189\" data-end=\"659\"\u003eAt AirGreen, we regularly install \u003cstrong data-start=\"247\" data-end=\"265\"\u003educted HVAC systems\u003c\/strong\u003e for clients who desire uniform comfort without compromising their interior aesthetics. The \u003cstrong data-start=\"371\" data-end=\"430\"\u003eFORESTAIR E24 18,000 BTU ducted heat pump\u003c\/strong\u003e stands out as a particularly suitable solution for properties located in \u003cstrong data-start=\"509\" data-end=\"572\"\u003eMontreal, Laval, Longueuil, on the North Shore, and the South Shore\u003c\/strong\u003e, especially in high-end renovation projects or new constructions.\u003c\/p\u003e\n\u003cp data-start=\"661\" data-end=\"906\"\u003eUnlike visible wall-mounted units, this system integrates directly into ceilings or false ceilings, distributing air through a network of ducts. The result: homogeneous, silent, and invisible air conditioning and heating.\u003c\/p\u003e\n\u003chr data-start=\"908\" data-end=\"911\"\u003e\n\u003ch2 data-section-id=\"12dfggu\" data-start=\"913\" data-end=\"973\"\u003eWhy choose a FORESTAIR E24 ducted heat pump?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"15i81sc\" data-start=\"975\" data-end=\"1030\"\u003eAn ultra-compact design for confined spaces\u003c\/h3\u003e\n\u003cp data-start=\"1032\" data-end=\"1260\"\u003eOne of the most remarkable features of this model is its \u003cstrong data-start=\"1093\" data-end=\"1151\"\u003eultra-slim profile of only 7.88 inches in height\u003c\/strong\u003e, allowing for installation in confined spaces, such as suspended ceilings or attics.\u003c\/p\u003e\n\u003cp data-start=\"1262\" data-end=\"1501\"\u003eAt AirGreen, we recently installed this model in a duplex in \u003cstrong data-start=\"1334\" data-end=\"1357\"\u003eRosemont (Montreal)\u003c\/strong\u003e where ceiling height limited options. This unit integrated perfectly without requiring major structural modifications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"cvguch\" data-start=\"1503\" data-end=\"1565\"\u003eSilent operation ideal for living spaces\u003c\/h3\u003e\n\u003cp data-start=\"1567\" data-end=\"1708\"\u003eThe indoor sound level ranges between \u003cstrong data-start=\"1606\" data-end=\"1624\"\u003e36 and 41 dB(A)\u003c\/strong\u003e, which is comparable to a soft whisper.\u003cbr data-start=\"1667\" data-end=\"1670\"\u003eThis makes it an excellent choice for:\u003c\/p\u003e\n\u003cul data-start=\"1710\" data-end=\"1813\"\u003e\n\u003cli data-section-id=\"1owu6j0\" data-start=\"1710\" data-end=\"1732\"\u003eBedrooms\u003c\/li\u003e\n\u003cli data-section-id=\"15145pk\" data-start=\"1733\" data-end=\"1755\"\u003eHome offices\u003c\/li\u003e\n\u003cli data-section-id=\"1p6e514\" data-start=\"1756\" data-end=\"1780\"\u003eHigh-end condos\u003c\/li\u003e\n\u003cli data-section-id=\"13tq9yi\" data-start=\"1781\" data-end=\"1813\"\u003eDiscreet commercial spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1815\" data-end=\"1981\"\u003eA client in \u003cstrong data-start=\"1827\" data-end=\"1854\"\u003eBoucherville (South Shore)\u003c\/strong\u003e specifically requested a quiet solution for their home office — this heat pump exceeded their expectations.\u003c\/p\u003e\n\u003chr data-start=\"1983\" data-end=\"1986\"\u003e\n\u003ch2 data-section-id=\"1qcxrtv\" data-start=\"1988\" data-end=\"2030\"\u003ePerformance adapted to Quebec's climate\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1ruhrne\" data-start=\"2032\" data-end=\"2068\"\u003eEfficient heating down to -25°C\u003c\/h3\u003e\n\u003cp data-start=\"2070\" data-end=\"2241\"\u003eThe \u003cstrong data-start=\"2073\" data-end=\"2090\"\u003eFORESTAIR E24\u003c\/strong\u003e is designed to operate efficiently even during harsh Quebec winters, with a heating capacity down to \u003cstrong data-start=\"2215\" data-end=\"2224\"\u003e-25°C\u003c\/strong\u003e. This means:\u003c\/p\u003e\n\u003cul data-start=\"2243\" data-end=\"2378\"\u003e\n\u003cli data-section-id=\"zk3mye\" data-start=\"2243\" data-end=\"2289\"\u003eLess reliance on auxiliary systems\u003c\/li\u003e\n\u003cli data-section-id=\"mfdv2y\" data-start=\"2290\" data-end=\"2341\"\u003eConstant comfort even in very cold weather\u003c\/li\u003e\n\u003cli data-section-id=\"at2xm6\" data-start=\"2342\" data-end=\"2378\"\u003eReduced energy costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"40fpkn\" data-start=\"2380\" data-end=\"2416\"\u003eCertified energy efficiency\u003c\/h3\u003e\n\u003cp data-start=\"2418\" data-end=\"2441\"\u003eThis heat pump is:\u003c\/p\u003e\n\u003cul data-start=\"2443\" data-end=\"2565\"\u003e\n\u003cli data-section-id=\"4q64b4\" data-start=\"2443\" data-end=\"2463\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2461\"\u003eENERGY STAR®\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1p6q0w5\" data-start=\"2464\" data-end=\"2507\"\u003e\u003cstrong data-start=\"2466\" data-end=\"2505\"\u003eENERGY STAR® Cold Climate Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1nbaewj\" data-start=\"2508\" data-end=\"2565\"\u003eEquipped with a \u003cstrong data-start=\"2521\" data-end=\"2536\"\u003ehigh SEER2\u003c\/strong\u003e and a \u003cstrong data-start=\"2545\" data-end=\"2565\"\u003ehigh-performing HSPF2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2567\" data-end=\"2728\"\u003eThese features allow homeowners to benefit from excellent energy efficiency, thereby reducing their electricity bills in the long term.\u003c\/p\u003e\n\u003chr data-start=\"2730\" data-end=\"2733\"\u003e\n\u003ch2 data-section-id=\"1k9epij\" data-start=\"2735\" data-end=\"2773\"\u003eKey technical data to know\u003c\/h2\u003e\n\u003cp data-start=\"2775\" data-end=\"2888\"\u003eHere are the important specifications we systematically analyze at AirGreen before any installation:\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jnye5n\" data-start=\"2890\" data-end=\"2919\"\u003eCapacities and performance\u003c\/h3\u003e\n\u003cul data-start=\"2921\" data-end=\"3054\"\u003e\n\u003cli data-section-id=\"ls6s1a\" data-start=\"2921\" data-end=\"2958\"\u003e\u003cstrong data-start=\"2923\" data-end=\"2958\"\u003eNominal power: 18,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"jbq03n\" data-start=\"2959\" data-end=\"2993\"\u003e\u003cstrong data-start=\"2961\" data-end=\"2993\"\u003eCapacity at -8°C: 14,500 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1i55czj\" data-start=\"2994\" data-end=\"3029\"\u003e\u003cstrong data-start=\"2996\" data-end=\"3029\"\u003eCapacity at -15°C: 13,200 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"3mwkr1\" data-start=\"3030\" data-end=\"3054\"\u003e\u003cstrong data-start=\"3032\" data-end=\"3054\"\u003eCOP at -8°C: 11.83\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oh7yhj\" data-start=\"3056\" data-end=\"3092\"\u003eAirflow and static pressure\u003c\/h3\u003e\n\u003cul data-start=\"3094\" data-end=\"3185\"\u003e\n\u003cli data-section-id=\"1rh1dr5\" data-start=\"3094\" data-end=\"3142\"\u003e\u003cstrong data-start=\"3096\" data-end=\"3140\"\u003eAirflow: up to 900 m³\/h (529 CFM)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"xcjuc6\" data-start=\"3143\" data-end=\"3185\"\u003e\u003cstrong data-start=\"3145\" data-end=\"3183\"\u003eStatic pressure: up to 100 Pa\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3187\" data-end=\"3323\"\u003eThis pressure allows for efficient air distribution in multiple rooms via ducts, even in complex configurations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"trpo4o\" data-start=\"3325\" data-end=\"3355\"\u003eDimensions and installation\u003c\/h3\u003e\n\u003cul data-start=\"3357\" data-end=\"3468\"\u003e\n\u003cli data-section-id=\"nhd4to\" data-start=\"3357\" data-end=\"3415\"\u003eInterior dimensions: \u003cstrong data-start=\"3384\" data-end=\"3415\"\u003e36.22 x 7.88 x 19.30 inches\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w4g6mz\" data-start=\"3416\" data-end=\"3447\"\u003ePiping: \u003cstrong data-start=\"3431\" data-end=\"3447\"\u003e1\/4 – 1\/2 in\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o5hp74\" data-start=\"3448\" data-end=\"3468\"\u003eVoltage: \u003cstrong data-start=\"3460\" data-end=\"3468\"\u003e220V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3470\" data-end=\"3609\"\u003eThese characteristics make this unit compatible with the majority of standard residential installations in the Montreal area.\u003c\/p\u003e\n\u003chr data-start=\"3611\" data-end=\"3614\"\u003e\n\u003ch2 data-section-id=\"1g4s10h\" data-start=\"3616\" data-end=\"3696\"\u003eReal-world experience: installation in Laval in an intergenerational home\u003c\/h2\u003e\n\u003cp data-start=\"3698\" data-end=\"3831\"\u003eWe recently completed a full installation in an intergenerational home in \u003cstrong data-start=\"3792\" data-end=\"3801\"\u003eLaval\u003c\/strong\u003e. The main challenge was to:\u003c\/p\u003e\n\u003cul data-start=\"3833\" data-end=\"3958\"\u003e\n\u003cli data-section-id=\"pp1ri9\" data-start=\"3833\" data-end=\"3885\"\u003eMaintain a stable temperature on two floors\u003c\/li\u003e\n\u003cli data-section-id=\"tkxanr\" data-start=\"3886\" data-end=\"3924\"\u003eAvoid visible wall units\u003c\/li\u003e\n\u003cli data-section-id=\"1cipfgk\" data-start=\"3925\" data-end=\"3958\"\u003eReduce noise pollution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3960\" data-end=\"4048\"\u003eWe opted for the \u003cstrong data-start=\"3984\" data-end=\"4010\"\u003educted FORESTAIR E24\u003c\/strong\u003e, with an optimized duct network.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ouc4h8\" data-start=\"4050\" data-end=\"4064\"\u003eResult:\u003c\/h3\u003e\n\u003cul data-start=\"4066\" data-end=\"4203\"\u003e\n\u003cli data-section-id=\"y61hr7\" data-start=\"4066\" data-end=\"4113\"\u003eUniform temperature in all rooms\u003c\/li\u003e\n\u003cli data-section-id=\"13wlruo\" data-start=\"4114\" data-end=\"4138\"\u003eNo visible units\u003c\/li\u003e\n\u003cli data-section-id=\"tyetlr\" data-start=\"4139\" data-end=\"4203\"\u003eSignificant noise reduction compared to their old system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4205\" data-end=\"4326\"\u003eThe client also benefited from the \u003cstrong data-start=\"4243\" data-end=\"4278\"\u003eLogisVert grant of $1,720\u003c\/strong\u003e, which made the project even more cost-effective.\u003c\/p\u003e\n\u003chr data-start=\"4328\" data-end=\"4331\"\u003e\n\u003ch2 data-section-id=\"9ytg2t\" data-start=\"4333\" data-end=\"4383\"\u003eHVAC installation: common mistakes to avoid\u003c\/h2\u003e\n\u003cp data-start=\"4385\" data-end=\"4581\"\u003eEven with excellent equipment, poor installation can compromise performance. Here are the mistakes we often observe (and systematically avoid at AirGreen):\u003c\/p\u003e\n\u003ch3 data-section-id=\"48wwk\" data-start=\"4583\" data-end=\"4623\"\u003eIncorrect duct sizing\u003c\/h3\u003e\n\u003cp data-start=\"4625\" data-end=\"4662\"\u003eImproperly calculated airflow leads to:\u003c\/p\u003e\n\u003cul data-start=\"4664\" data-end=\"4768\"\u003e\n\u003cli data-section-id=\"dcjzxc\" data-start=\"4664\" data-end=\"4696\"\u003eCold or hot spots\u003c\/li\u003e\n\u003cli data-section-id=\"dl3xsz\" data-start=\"4697\" data-end=\"4732\"\u003eExcessive energy consumption\u003c\/li\u003e\n\u003cli data-section-id=\"1537sra\" data-start=\"4733\" data-end=\"4768\"\u003ePremature system wear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1d67ac8\" data-start=\"4770\" data-end=\"4802\"\u003ePoor drainage management\u003c\/h3\u003e\n\u003cp data-start=\"4804\" data-end=\"4964\"\u003eThis unit includes a \u003cstrong data-start=\"4827\" data-end=\"4870\"\u003ebuilt-in 47-inch condensate pump\u003c\/strong\u003e, facilitating condensate removal.\u003cbr data-start=\"4911\" data-end=\"4914\"\u003eHowever, improper installation can cause:\u003c\/p\u003e\n\u003cul data-start=\"4966\" data-end=\"5023\"\u003e\n\u003cli data-section-id=\"cs2z3w\" data-start=\"4966\" data-end=\"4982\"\u003eWater leaks\u003c\/li\u003e\n\u003cli data-section-id=\"v5y5jc\" data-start=\"4983\" data-end=\"4998\"\u003eMold\u003c\/li\u003e\n\u003cli data-section-id=\"15l2qjd\" data-start=\"4999\" data-end=\"5023\"\u003eStructural damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j52wa2\" data-start=\"5025\" data-end=\"5071\"\u003eInadequate air intake positioning\u003c\/h3\u003e\n\u003cp data-start=\"5073\" data-end=\"5233\"\u003eThanks to its \u003cstrong data-start=\"5085\" data-end=\"5110\"\u003eflexible air return\u003c\/strong\u003e, this unit allows for several configurations.\u003cbr data-start=\"5156\" data-end=\"5159\"\u003eBut poor design can reduce the overall efficiency of the system.\u003c\/p\u003e\n\u003chr data-start=\"5235\" data-end=\"5238\"\u003e\n\u003ch2 data-section-id=\"63ad3h\" data-start=\"5240\" data-end=\"5299\"\u003eWhy choose AirGreen for your HVAC installation?\u003c\/h2\u003e\n\u003cp data-start=\"5301\" data-end=\"5428\"\u003eAt AirGreen, we don't just install systems — we design solutions tailored to each property.\u003c\/p\u003e\n\u003ch3 data-section-id=\"rdi6z0\" data-start=\"5430\" data-end=\"5450\"\u003eOur approach:\u003c\/h3\u003e\n\u003cul data-start=\"5452\" data-end=\"5662\"\u003e\n\u003cli data-section-id=\"1m71827\" data-start=\"5452\" data-end=\"5482\"\u003eComprehensive thermal analysis\u003c\/li\u003e\n\u003cli data-section-id=\"c4d2t3\" data-start=\"5483\" data-end=\"5518\"\u003ePrecise load calculations (BTU)\u003c\/li\u003e\n\u003cli data-section-id=\"1wcawd0\" data-start=\"5519\" data-end=\"5569\"\u003eCustom duct network design\u003c\/li\u003e\n\u003cli data-section-id=\"2kw2w6\" data-start=\"5570\" data-end=\"5616\"\u003eInstallation by certified refrigeration technicians\u003c\/li\u003e\n\u003cli data-section-id=\"vcfo4f\" data-start=\"5617\" data-end=\"5662\"\u003eComplete commissioning and verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1bjw8xa\" data-start=\"5664\" data-end=\"5690\"\u003eOur added value:\u003c\/h3\u003e\n\u003cul data-start=\"5692\" data-end=\"5882\"\u003e\n\u003cli data-section-id=\"4ls6xm\" data-start=\"5692\" data-end=\"5728\"\u003e\u003cstrong data-start=\"5694\" data-end=\"5726\"\u003eTotal price transparency\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1f829bg\" data-start=\"5729\" data-end=\"5771\"\u003e\u003cstrong data-start=\"5731\" data-end=\"5769\"\u003eNo surprises after installation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1jsm3ms\" data-start=\"5772\" data-end=\"5846\"\u003e\u003cstrong data-start=\"5774\" data-end=\"5844\"\u003eFast service in Montreal, Laval, Longueuil, North Shore, and South Shore\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1wfh3r0\" data-start=\"5847\" data-end=\"5882\"\u003e\u003cstrong data-start=\"5849\" data-end=\"5880\"\u003eResponsive after-sales support\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5884\" data-end=\"5887\"\u003e\n\u003ch2 data-section-id=\"1b4weuz\" data-start=\"5889\" data-end=\"5954\"\u003eAn ideal solution for modern and high-end projects\u003c\/h2\u003e\n\u003cp data-start=\"5956\" data-end=\"6037\"\u003eThe \u003cstrong data-start=\"5959\" data-end=\"5997\"\u003eFORESTAIR E24 ducted heat pump\u003c\/strong\u003e is particularly recommended for:\u003c\/p\u003e\n\u003cul data-start=\"6039\" data-end=\"6145\"\u003e\n\u003cli data-section-id=\"1zm0ya\" data-start=\"6039\" data-end=\"6057\"\u003eNew homes\u003c\/li\u003e\n\u003cli data-section-id=\"qy9bg8\" data-start=\"6058\" data-end=\"6082\"\u003eMajor renovations\u003c\/li\u003e\n\u003cli data-section-id=\"11j8l4n\" data-start=\"6083\" data-end=\"6101\"\u003eLuxury condos\u003c\/li\u003e\n\u003cli data-section-id=\"1yqg4vo\" data-start=\"6102\" data-end=\"6145\"\u003eProperties with aesthetic constraints\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6147\" data-end=\"6263\"\u003eIts invisible integration and high performance make it a strategic choice for discerning homeowners.\u003c\/p\u003e\n\u003chr data-start=\"6265\" data-end=\"6268\"\u003e\n\u003ch2 data-section-id=\"gie36q\" data-start=\"6270\" data-end=\"6334\"\u003eConclusion: a smart investment for your comfort\u003c\/h2\u003e\n\u003cp data-start=\"6336\" data-end=\"6417\"\u003eOpting for an \u003cstrong data-start=\"6351\" data-end=\"6400\"\u003e18,000 BTU FORESTAIR E24 ducted heat pump\u003c\/strong\u003e means choosing:\u003c\/p\u003e\n\u003cul data-start=\"6419\" data-end=\"6562\"\u003e\n\u003cli data-section-id=\"1ytq267\" data-start=\"6419\" data-end=\"6442\"\u003eUniform comfort\u003c\/li\u003e\n\u003cli data-section-id=\"14nm1e2\" data-start=\"6443\" data-end=\"6482\"\u003eOptimal energy efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"1lq9kz6\" data-start=\"6483\" data-end=\"6511\"\u003eDiscreet integration\u003c\/li\u003e\n\u003cli data-section-id=\"1d86wxr\" data-start=\"6512\" data-end=\"6562\"\u003eReliable performance even in Quebec winters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6564\" data-end=\"6700\"\u003eAt AirGreen, we have the field expertise to maximize the performance of this type of system and guarantee impeccable installation.\u003c\/p\u003e\n\u003chr data-start=\"6702\" data-end=\"6705\"\u003e\n\u003ch2 data-section-id=\"o7bw1n\" data-start=\"6707\" data-end=\"6744\"\u003eContact AirGreen today\u003c\/h2\u003e\n\u003cp data-start=\"6746\" data-end=\"6859\"\u003eAre you considering a \u003cstrong data-start=\"6765\" data-end=\"6857\"\u003educted HVAC installation in Montreal, Laval, Longueuil, on the North Shore, or the South Shore\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp data-start=\"6861\" data-end=\"6890\"\u003eContact our team for:\u003c\/p\u003e\n\u003cul data-start=\"6892\" data-end=\"7006\"\u003e\n\u003cli data-section-id=\"1o2arri\" data-start=\"6892\" data-end=\"6920\"\u003eA detailed quote\u003c\/li\u003e\n\u003cli data-section-id=\"p5m3e4\" data-start=\"6921\" data-end=\"6953\"\u003eA personalized evaluation\u003c\/li\u003e\n\u003cli data-section-id=\"fc5l62\" data-start=\"6954\" data-end=\"7006\"\u003eExpert advice tailored to your property\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"7008\" data-end=\"7099\"\u003eAirGreen supports you every step of the way, from product selection to full commissioning.\u003c\/p\u003e","brand":"ForestAir","offers":[{"title":"Default Title","offer_id":52648130347300,"sku":"FA-K18-D24TL-I-454","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEGAINABLEFORESTAIR-SERIEE24_9a6f3807-7511-4c0a-a878-359f59b83baf.png?v=1775095194","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-conduits-gainables-forestair-e24-18000-btu-montreal-monteregie","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}