{"product_id":"thermopompe-console-de-plancher-senville-sena-r454b-24000-btu","title":"Floor Console Heat Pump SENVILLE SENA R454B | 24000 BTU","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA low-wall heat pump that completely changes the installation possibilities in a room that is difficult to cool\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e24,000 BTU SENVILLE SENA R454B floor console heat pump\u003c\/strong\u003e meets a need we regularly encounter in \u003cstrong\u003eheating and cooling projects in Montreal, Laval, Longueuil, the North Shore, and the South Shore\u003c\/strong\u003e: the room requires substantial capacity, but the ideal location for a traditional wall-mounted head simply does not exist.\u003c\/p\u003e\n\u003cp\u003eThe reasons can be very practical. A room may have windows that extend almost to the ceiling, a sloped wall, a large patio door, a cathedral ceiling, built-in cabinets, or architecture that makes a wall-mounted unit unattractive. In these situations, a \u003cstrong\u003efloor console\u003c\/strong\u003e allows the indoor unit to be installed much lower on the wall, in a configuration that resembles a modern convector more than a conventional wall-mounted heat pump.\u003c\/p\u003e\n\u003cp\u003eThe SENVILLE unit on this page uses:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: SENA-24HF-OG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: SENA-24HF-IFG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFamily nominal capacity: 24,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI: 215735310\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR reference: 3630057\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2: 20.4\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2: 12.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2: 12.1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCold climate: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating down to -30 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWi-Fi: optional\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 208\/230 V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum indoor airflow: approximately 577 CFM\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 25 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMOP: 25 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor sound level: 61.5 dB\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor sound level: 34 to 51.5 dB depending on the speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor dimensions: 42.05 × 26.57 × 9.25 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor dimensions: 37.24 × 16.14 × 31.89 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdditional warranty: available\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndicated provincial rebate: $2,424\u003c\/strong\u003e, subject to the project’s actual eligibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSenville’s documentation does indeed present the \u003cstrong\u003eSENA\/24HF\/IF\u003c\/strong\u003e as a \u003cstrong\u003eFloor Mounted\u003c\/strong\u003e mini-split heat pump, meaning an indoor unit installed at the bottom of the wall, providing heating and cooling. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eA floor console is not simply a wall-mounted heat pump installed lower down\u003c\/h3\u003e\n\u003cp\u003eThe difference is not limited to its appearance.\u003c\/p\u003e\n\u003cp\u003eThe indoor unit is specifically designed for low-wall installation. Its body measures approximately \u003cstrong\u003e42 inches wide, 26.57 inches high, and only 9.25 inches deep\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis design allows it to be integrated into locations where a traditional wall-mounted head would be poorly suited, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eunder certain windows;\u003c\/li\u003e\n\u003cli\u003eon a low wall;\u003c\/li\u003e\n\u003cli\u003ein an attic room;\u003c\/li\u003e\n\u003cli\u003ein an area where the upper part of the walls must remain clear;\u003c\/li\u003e\n\u003cli\u003ein a basement;\u003c\/li\u003e\n\u003cli\u003ein a room with a very high ceiling;\u003c\/li\u003e\n\u003cli\u003ein a space where air distribution from the lower level is preferred.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we consider this format a genuine architectural alternative, not merely an aesthetic variation.\u003c\/p\u003e\n\u003ch3\u003eA particularly interesting solution beneath a sloped ceiling\u003c\/h3\u003e\n\u003cp\u003eLet us consider a typical scenario.\u003c\/p\u003e\n\u003cp\u003eA bedroom located upstairs in a house on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e has a sloped ceiling. It is impossible to install a wall-mounted head high enough without interfering with the ceiling slope. The opposite wall is occupied by a large window, while a third wall contains the closet doors.\u003c\/p\u003e\n\u003cp\u003eA floor console can make it possible to use a lower section of the wall that would otherwise be difficult to utilize.\u003c\/p\u003e\n\u003cp\u003eFor this type of project, the choice of indoor unit addresses all of the following at once:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003espace constraints;\u003c\/li\u003e\n\u003cli\u003eair distribution;\u003c\/li\u003e\n\u003cli\u003eaesthetics;\u003c\/li\u003e\n\u003cli\u003eaccess for maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e20.4 SEER2 and ENERGY STAR certification\u003c\/h3\u003e\n\u003cp\u003eSenville indicates an efficiency of \u003cstrong\u003e20.4 SEER2\u003c\/strong\u003e and an \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certification for this product family. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe technical table confirms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2: 20.4\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2: 12\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2 region 4: 12.1\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2 region 5: 9.8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal COP: 3.34 W\/W\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a heat pump of this capacity, these values offer an interesting combination of cooling efficiency and seasonal heating performance.\u003c\/p\u003e\n\u003cp\u003eNevertheless, the nominal COP must be distinguished from low-temperature performance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCOP of 3.34\u003c\/strong\u003e is measured under a reference condition. It does not mean that the heat pump maintains the same efficiency at -15 °C or -30 °C.\u003c\/p\u003e\n\u003ch3\u003ePerformance at -8 °C is much more useful for evaluating a Montreal winter.\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen data sheet indicates the following for this configuration:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAt -8 °C:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eheating capacity: 20,200 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP: 2.74\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis performance point is particularly relevant to the Greater Montreal climate.\u003c\/p\u003e\n\u003cp\u003eA COP of 2.74 means that under this condition, the system transfers approximately 2.74 units of heat for every unit of electricity consumed by the heat-pump cycle.\u003c\/p\u003e\n\u003cp\u003eFor a property heated primarily with electricity, this allows the heat pump to handle a significant share of the heating during a large part of the winter.\u003c\/p\u003e\n\u003ch3\u003e24,200 BTU at -15 °C according to the AirGreen configuration data\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e, the AirGreen data sheet indicates a capacity of \u003cstrong\u003e24,200 BTU\/h\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis value is particularly interesting because it remains very close to the 24,000 BTU nominal class.\u003c\/p\u003e\n\u003cp\u003eThe Senville documentation provided does not include detailed capacity tables at -8 °C and -15 °C; however, it confirms that the system belongs to the \u003cstrong\u003ecold-climate\u003c\/strong\u003e category and can operate in heating mode down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhen comparing this heat pump with another unit for a specific project, we therefore use the data for the exact match \u003cstrong\u003eAHRI 215735310\u003c\/strong\u003e, rather than a simple nominal capacity indication.\u003c\/p\u003e\n\u003ch3\u003eAt -30 °C: approximately 10,500 BTU and a COP of 1.33\u003c\/h3\u003e\n\u003cp\u003eThe most useful figure for avoiding unrealistic expectations is the minimum temperature.\u003c\/p\u003e\n\u003cp\u003eThe SENVILLE can operate down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the brochure confirms a minimum outdoor heating temperature of \u003cstrong\u003e-22 °F \/ -30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt this temperature, AirGreen data indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ecapacity: approximately 10,500 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP: 1.33\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe difference between these two pieces of information is essential:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ethe heat pump still operates at -30 °C, but it no longer provides 24,000 BTU at that temperature.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis reality must be incorporated into the heating calculation.\u003c\/p\u003e\n\u003cp\u003eIn a room or zone whose heat losses exceed 10,500 BTU\/h during extreme cold, another heat source must supplement the heat pump.\u003c\/p\u003e\n\u003ch3\u003eWhy this capacity at -30 °C is still useful\u003c\/h3\u003e\n\u003cp\u003eA COP of \u003cstrong\u003e1,33\u003c\/strong\u003e is still higher than a resistive electric heating system operating alone, which essentially converts one unit of electricity into one unit of heat.\u003c\/p\u003e\n\u003cp\u003eThe heat pump therefore continues to contribute to heating, even during extremely cold weather.\u003c\/p\u003e\n\u003cp\u003eFor an installation in \u003cstrong\u003eLaval, Montreal, Longueuil, Terrebonne, Boucherville, or on the South Shore\u003c\/strong\u003e, this extends the period during which the compressor contributes to heating rather than leaving the entire load to baseboard heaters or a backup system.\u003c\/p\u003e\n\u003ch3\u003eThe brochure gives 22,000 BTU for cooling and 26,000 BTU for heating.\u003c\/h3\u003e\n\u003cp\u003eOne technical detail deserves explanation.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen page presents the unit in the \u003cstrong\u003e24,000 BTU\u003c\/strong\u003e class, while the Senville technical table gives:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ecooling capacity: 22,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003ecooling range: \u003cstrong\u003e12,700 to 25,600 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eheating capacity: 26,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eheating range: \u003cstrong\u003e11,300 to 29,500 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis type of difference is normal in HVAC specifications.\u003c\/p\u003e\n\u003cp\u003e“24,000 BTU” is a commercial capacity class, while certified capacities may differ depending on the operating mode and test conditions.\u003c\/p\u003e\n\u003cp\u003eFor proper sizing, we therefore never work solely with the figure stated in the product name.\u003c\/p\u003e\n\u003ch3\u003eModulation reaching nearly 29,500 BTU in heating\u003c\/h3\u003e\n\u003cp\u003eThe published range of up to \u003cstrong\u003e29,500 BTU\/h in heating mode\u003c\/strong\u003e demonstrates the importance of inverter technology.\u003c\/p\u003e\n\u003cp\u003eThe heat pump can vary its output according to demand.\u003c\/p\u003e\n\u003cp\u003eIt is not limited to two states: off or 24,000 BTU.\u003c\/p\u003e\n\u003cp\u003eWhen the load is low, it can reduce its output. When conditions require it, it can increase its capacity within the limits specified by the manufacturer.\u003c\/p\u003e\n\u003cp\u003eThis modulation can help:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emaintain a more stable temperature;\u003c\/li\u003e\n\u003cli\u003ereduce variations between cycles;\u003c\/li\u003e\n\u003cli\u003elimit certain repeated start-ups;\u003c\/li\u003e\n\u003cli\u003eadapt the heating to the room’s actual needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e577 CFM maximum indoor airflow\u003c\/h3\u003e\n\u003cp\u003eThe published airflow is:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e576.8 CFM in Turbo mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e547.4 CFM at high speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e485.6 CFM at medium speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e420.8 CFM at low speed\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e577 CFM\u003c\/strong\u003e value on the AirGreen specification sheet therefore corresponds to the unit’s maximum airflow.\u003c\/p\u003e\n\u003cp\u003eThis airflow is significant for a 24,000 BTU console, particularly when it has to serve a large open room.\u003c\/p\u003e\n\u003ch3\u003eWarm air rises from below: an interesting feature for heating\u003c\/h3\u003e\n\u003cp\u003eHeating from a low-mounted unit can be very comfortable.\u003c\/p\u003e\n\u003cp\u003eWarm air naturally tends to rise. A floor console can therefore distribute heat from the lower part of the room rather than from the ceiling.\u003c\/p\u003e\n\u003cp\u003eThis can be particularly useful in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea living room with a cathedral ceiling;\u003c\/li\u003e\n\u003cli\u003ea large open room;\u003c\/li\u003e\n\u003cli\u003ea basement;\u003c\/li\u003e\n\u003cli\u003ea room with large glazed surfaces;\u003c\/li\u003e\n\u003cli\u003ea space where occupants remain seated for long periods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe location must nevertheless be chosen carefully to avoid blowing air directly onto a sofa or workstation.\u003c\/p\u003e\n\u003ch3\u003eAutomatic vertical louver and manual horizontal adjustment\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003evertical louvers: automatic\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ehorizontal louvers: manual\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration makes it possible to adjust the airflow direction according to the room’s layout.\u003c\/p\u003e\n\u003cp\u003eWe recommend considering the orientation even before securing the unit.\u003c\/p\u003e\n\u003cp\u003eA console installed too close to a piece of furniture or behind a sofa loses part of its advantage. The space in front of the air outlet must remain sufficiently clear.\u003c\/p\u003e\n\u003ch3\u003eIndoor sound level: 34 to 51.5 dB depending on the speed\u003c\/h3\u003e\n\u003cp\u003eThe brochure states:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e51.5 dB in Turbo mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e49 dB at high speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e45 dB at medium speed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e34 dB at low speed\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 34 dB figure is useful during periods when the load is moderate.\u003c\/p\u003e\n\u003cp\u003eHowever, values measured at equivalent speeds must be compared when evaluating two models. A unit rated at 34 dB at low speed should not be directly compared with another measured only in maximum mode.\u003c\/p\u003e\n\u003ch3\u003eDehumidification: 2.73 L\/h, or approximately 5.77 U.S. pints per hour\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet indicates dehumidification of \u003cstrong\u003e5.77 pt\/h\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe brochure indicates \u003cstrong\u003e2.73 L\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese two figures are consistent: 2.73 litres correspond to approximately \u003cstrong\u003e5.77 U.S. pints\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis information is useful for summer air conditioning.\u003c\/p\u003e\n\u003cp\u003eIn \u003cstrong\u003eMontreal, Laval, and Longueuil\u003c\/strong\u003e, some hot days are particularly humid. Effective air conditioning must not only lower the temperature; it must also remove humidity.\u003c\/p\u003e\n\u003cp\u003eAn indoor temperature of 23 °C with excessively high humidity can remain uncomfortable.\u003c\/p\u003e\n\u003ch2\u003eAirGreen installation: why the low placement, drainage, and R-454B must be considered together\u003c\/h2\u003e\n\u003ch3\u003eThe console does not need to be placed exactly on the floor\u003c\/h3\u003e\n\u003cp\u003eThe term “floor console” primarily describes its format and low position.\u003c\/p\u003e\n\u003cp\u003eIt must be installed in accordance with the clearances specified by Senville, and its location must allow for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eproper air intake;\u003c\/li\u003e\n\u003cli\u003eunrestricted airflow;\u003c\/li\u003e\n\u003cli\u003eaccess to the filter;\u003c\/li\u003e\n\u003cli\u003emaintenance;\u003c\/li\u003e\n\u003cli\u003edrainage;\u003c\/li\u003e\n\u003cli\u003ethe refrigerant line route.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn our installations, we avoid placing the unit behind:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea sofa;\u003c\/li\u003e\n\u003cli\u003ea bed;\u003c\/li\u003e\n\u003cli\u003ea dresser;\u003c\/li\u003e\n\u003cli\u003ea heavy curtain;\u003c\/li\u003e\n\u003cli\u003ea large plant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA 24,000 BTU unit needs to move several hundred CFM. Blocking its intake or airflow directly reduces its efficiency.\u003c\/p\u003e\n\u003ch3\u003eAn excellent option under certain windows, but not under just any window\u003c\/h3\u003e\n\u003cp\u003eThe low-profile design can make the console an interesting option under a window.\u003c\/p\u003e\n\u003cp\u003eHowever, it must be measured.\u003c\/p\u003e\n\u003cp\u003eThe indoor unit is approximately \u003cstrong\u003e26.57 in. high\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe required clearances must also be maintained.\u003c\/p\u003e\n\u003cp\u003eIn an older Montreal home where the bottom of the window is very close to the floor, the console may not fit.\u003c\/p\u003e\n\u003cp\u003eWe therefore measure the actual space rather than assuming that a floor console will fit everywhere under a window.\u003c\/p\u003e\n\u003ch3\u003eR-454B is clearly confirmed by the brochure\u003c\/h3\u003e\n\u003cp\u003eSenville documentation identifies the refrigerant as \u003cstrong\u003eR-454B\u003c\/strong\u003e. It indicates a charge of \u003cstrong\u003e63.49 oz\u003c\/strong\u003e and a precharge covering \u003cstrong\u003e25 ft\u003c\/strong\u003e of piping. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSenville also specifies that the system is precharged for up to 25 ft and that a 50 ft kit requires refrigerant to be added on site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is important information when preparing a quote.\u003c\/p\u003e\n\u003cp\u003eThe actual length of the lines must be known before commissioning.\u003c\/p\u003e\n\u003ch3\u003eWe never assume that old piping is automatically reusable\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a system, a customer sometimes asks us to keep the existing lines to reduce the amount of work.\u003c\/p\u003e\n\u003cp\u003eThis may be possible for some projects, but only after verification.\u003c\/p\u003e\n\u003cp\u003eWe examine:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe diameter;\u003c\/li\u003e\n\u003cli\u003ethe length;\u003c\/li\u003e\n\u003cli\u003ethe condition of the lines;\u003c\/li\u003e\n\u003cli\u003ethe old refrigerant;\u003c\/li\u003e\n\u003cli\u003ethe route;\u003c\/li\u003e\n\u003cli\u003ethe new model’s requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFor this configuration, the final piping dimensions must be confirmed in the installation documentation corresponding exactly to the \u003cstrong\u003eSENA-24HF-OG + SENA-24HF-IFG\u003c\/strong\u003e pairing.\u003c\/p\u003e\n\u003ch3\u003eMCA and MOP of 25 A: a point to check at the electrical panel\u003c\/h3\u003e\n\u003cp\u003eThe technical table indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 25 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emaximum fuse: 25 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe system operates at \u003cstrong\u003e208\/230 V single-phase, 60 Hz\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis means that an adequate circuit must be available.\u003c\/p\u003e\n\u003cp\u003eBefore installation, we check the panel capacity and required circuit rather than waiting until the workday to discover that an additional electrical modification is necessary.\u003c\/p\u003e\n\u003ch3\u003eThe outdoor unit is considerably larger than that of a small 12,000 BTU unit\u003c\/h3\u003e\n\u003cp\u003eIts dimensions are:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e37.24 × 16.14 × 31.89 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eand weighs approximately \u003cstrong\u003e130.29 lb\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum outdoor airflow reaches \u003cstrong\u003e2,236.7 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis unit must therefore have sufficient space around the heat exchanger.\u003c\/p\u003e\n\u003cp\u003eWe avoid locations that are too confined between two walls or behind structures that would restrict airflow.\u003c\/p\u003e\n\u003ch3\u003e61.5 dB outdoors\u003c\/h3\u003e\n\u003cp\u003eThe published outdoor sound level is \u003cstrong\u003e61.5 dB\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe location must therefore be carefully considered based on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebedroom windows;\u003c\/li\u003e\n\u003cli\u003eneighbors;\u003c\/li\u003e\n\u003cli\u003edecks;\u003c\/li\u003e\n\u003cli\u003ereflective walls;\u003c\/li\u003e\n\u003cli\u003eproperty lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn outdoor unit may seem louder in a narrow passage between two buildings than in an open area.\u003c\/p\u003e\n\u003ch3\u003eDrainage must be planned as it would be for any heat pump\u003c\/h3\u003e\n\u003cp\u003eIn cooling mode, the indoor unit removes moisture from the air and produces condensate.\u003c\/p\u003e\n\u003cp\u003eThe drain must be installed with an adequate slope when gravity drainage is used.\u003c\/p\u003e\n\u003cp\u003eWe want to avoid:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ebackflow;\u003c\/li\u003e\n\u003cli\u003estanding water;\u003c\/li\u003e\n\u003cli\u003eleaks;\u003c\/li\u003e\n\u003cli\u003eodors;\u003c\/li\u003e\n\u003cli\u003eunnecessarily added pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA floor console can sometimes make drainage easier because it is located lower than a wall-mounted head, but the outdoor exit point must still be evaluated.\u003c\/p\u003e\n\u003ch3\u003eENERGY STAR and AHRI 215735310\u003c\/h3\u003e\n\u003cp\u003eSenville confirms this unit’s \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certification as well as its \u003cstrong\u003e20.4 SEER2\u003c\/strong\u003e efficiency rating. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product sheet identifies the match under:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI 215735310\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR 3630057\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese are the references that become important when we verify the criteria for a financial assistance program.\u003c\/p\u003e\n\u003ch3\u003eA provincial rebate listed at $2,424\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet indicates a provincial incentive of \u003cstrong\u003e2 424 $\u003c\/strong\u003e for this configuration.\u003c\/p\u003e\n\u003cp\u003eThe actual amount must always be confirmed according to the criteria applicable to the project at the time of installation.\u003c\/p\u003e\n\u003cp\u003eWe notably verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe exact model;\u003c\/li\u003e\n\u003cli\u003ethe AHRI match;\u003c\/li\u003e\n\u003cli\u003ethe type of residence;\u003c\/li\u003e\n\u003cli\u003ethe program rules;\u003c\/li\u003e\n\u003cli\u003ethe required documents;\u003c\/li\u003e\n\u003cli\u003ethe installation date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a customer comparing several \u003cstrong\u003eheat pumps in Montreal or on the South Shore\u003c\/strong\u003e, the rebate can significantly change the project’s net cost. It should therefore be included in the comparison, but only after eligibility has been confirmed.\u003c\/p\u003e\n\u003ch3\u003eOptional Wi-Fi\u003c\/h3\u003e\n\u003cp\u003eThe configuration includes \u003cstrong\u003eoptional Wi-Fi\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis feature may allow the setpoint or schedule to be adjusted remotely, depending on the installed module.\u003c\/p\u003e\n\u003cp\u003eIt is appealing, but we consider it a secondary benefit.\u003c\/p\u003e\n\u003cp\u003eThe choice of a heat pump should first be guided by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ecapacity;\u003c\/li\u003e\n\u003cli\u003elow-temperature performance;\u003c\/li\u003e\n\u003cli\u003elocation;\u003c\/li\u003e\n\u003cli\u003enoise level;\u003c\/li\u003e\n\u003cli\u003esizing;\u003c\/li\u003e\n\u003cli\u003einstallation quality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA mobile app cannot compensate for a poorly positioned or improperly sized unit.\u003c\/p\u003e\n\u003ch3\u003eSelf-diagnostics and leak detection\u003c\/h3\u003e\n\u003cp\u003eSenville mentions integrated \u003cstrong\u003ediagnostic and leak-detection\u003c\/strong\u003e functions designed to flag certain issues and facilitate maintenance. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese tools can be useful during a service call.\u003c\/p\u003e\n\u003cp\u003eHowever, they do not replace measurements taken by a technician.\u003c\/p\u003e\n\u003cp\u003eA comfort problem may result from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eof the refrigerant;\u003c\/li\u003e\n\u003cli\u003eof the airflow;\u003c\/li\u003e\n\u003cli\u003eof the filter;\u003c\/li\u003e\n\u003cli\u003eof the drain;\u003c\/li\u003e\n\u003cli\u003eof the controller;\u003c\/li\u003e\n\u003cli\u003eof the temperature sensor;\u003c\/li\u003e\n\u003cli\u003eof improper outdoor installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty: 10 years on the compressor and 5 years on parts in the attached documentation\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet mentions a \u003cstrong\u003e10-10-0 manufacturer’s warranty\u003c\/strong\u003e as well as the possibility of an additional warranty.\u003c\/p\u003e\n\u003cp\u003eThe attached Senville brochure states:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e10 years on the compressor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe technical table also repeats this coverage. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSenville also specifies that professional installation is required to maintain the expected coverage and performance. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore always confirm the exact warranty terms applicable to the delivered and registered equipment.\u003c\/p\u003e\n\u003ch3\u003eIn which rooms does the 24,000 BTU floor console really make sense?\u003c\/h3\u003e\n\u003cp\u003eThis configuration may be particularly well suited to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea large open-plan area;\u003c\/li\u003e\n\u003cli\u003ea finished basement;\u003c\/li\u003e\n\u003cli\u003ea room with a sloped ceiling;\u003c\/li\u003e\n\u003cli\u003ea loft;\u003c\/li\u003e\n\u003cli\u003ea living room with lots of glazing;\u003c\/li\u003e\n\u003cli\u003ean addition;\u003c\/li\u003e\n\u003cli\u003ea commercial office;\u003c\/li\u003e\n\u003cli\u003ea room where the upper part of the walls is unavailable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt therefore combines several advantages:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e24,000 BTU class\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e20.4 SEER2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12.1 HSPF2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eheating down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eR-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eindoor airflow of up to \u003cstrong\u003e577 CFM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certification\n\u003c\/li\u003e\n\u003cli\u003elow installation\u003c\/li\u003e\n\u003cli\u003eOptional Wi-Fi\u003c\/li\u003e\n\u003cli\u003epossibility of a financial incentive indicated at \u003cstrong\u003e2 424 $\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen a Wall-Mounted Head May Still Be Preferable\u003c\/h3\u003e\n\u003cp\u003eThe console is not automatically the best choice.\u003c\/p\u003e\n\u003cp\u003eA wall-mounted head may make more sense when there is a clear wall high up and you want to project air over a long distance from the top of the room.\u003c\/p\u003e\n\u003cp\u003eThe console becomes particularly appealing when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe upper part of the walls is unusable;\u003c\/li\u003e\n\u003cli\u003ea lower installation is preferred;\u003c\/li\u003e\n\u003cli\u003ethe room’s architecture is suitable;\u003c\/li\u003e\n\u003cli\u003elow-level heating is desired.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe therefore choose the type of indoor unit based on the building, not just the compressor capacity.\u003c\/p\u003e\n\u003ch3\u003eWhy AirGreen Looks at the Room First Before Recommending the Unit Type\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen Air Conditioning \u0026amp; Heating\u003c\/strong\u003e, we do not assume that a wall-mounted head is always the default solution.\u003c\/p\u003e\n\u003cp\u003eFor each project, we consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eavailable walls;\u003c\/li\u003e\n\u003cli\u003ewindows;\u003c\/li\u003e\n\u003cli\u003efurniture;\u003c\/li\u003e\n\u003cli\u003eceiling height;\u003c\/li\u003e\n\u003cli\u003eair circulation;\u003c\/li\u003e\n\u003cli\u003edrainage;\u003c\/li\u003e\n\u003cli\u003ethe length of the lines;\u003c\/li\u003e\n\u003cli\u003ethe outdoor location;\u003c\/li\u003e\n\u003cli\u003ethe requirements at -8 °C, -15 °C, and during extreme cold.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is particularly important with this \u003cstrong\u003e24,000 BTU SENVILLE floor console\u003c\/strong\u003e, because its main advantage lies precisely in situations where a traditional wall-mounted unit does not integrate well.\u003c\/p\u003e\n\u003ch3\u003eContact AirGreen for your 24,000 BTU SENVILLE SENA floor console\u003c\/h3\u003e\n\u003cp\u003eAre you considering a \u003cstrong\u003eSENVILLE SENA R454B 24,000 BTU floor console heat pump\u003c\/strong\u003e for your house, condo, basement, or commercial space?\u003c\/p\u003e\n\u003cp\u003eContact \u003cstrong\u003eAirGreen\u003c\/strong\u003e for a project assessment. We can verify the required capacity, the ideal console location, the electrical circuit, the refrigerant line routing, drainage, the outdoor unit, and eligibility for financial incentives.\u003c\/p\u003e\n\u003cp\u003eWe carry out \u003cstrong\u003eheat pump installations in Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie\u003c\/strong\u003e, with particular attention to sizing, indoor unit integration, and winter performance.\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56120259674404,"sku":"SENA-24HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_CONSOLE_DE_PLANCHER_SENVILLE_AURA_R454B_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1789067632","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-console-de-plancher-senville-sena-r454b-24000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}