{"product_id":"thermopompe-monobloc-york-ph3-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eCommon areas and small offices: a reliable heat pump, simple to maintain\u003c\/h2\u003e\n\u003cp\u003eEntrance hall, corridors, community room, ground floor offices in a mixed-use building: the common areas of a plex or a small building have to stay comfortable without becoming a headache for the owner or the manager. The 4 ton YORK PH3 heat pump in the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e version suits this kind of assignment particularly well: 48,000 BTU\/h of nominal capacity, proven construction, easy service access and straightforward control. We install it for owners, condo boards and building managers across the greater region: Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged unit in a building\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e concentrates the whole refrigeration system and the supply fan in a single cabinet, set on the roof or at ground level. The ducts carry the conditioned air into the common areas, then bring it back to the unit. No mechanical room to build, no indoor unit to fit into a corridor closet, and above all no need to enter the apartments for maintenance: the technician works outside, at the time that suits the building.\u003c\/p\u003e\n\u003ch3\u003eReliability starts at the factory\u003c\/h3\u003e\n\u003cp\u003eThe PH3 units are assembled in a plant whose quality management system is ISO 9001:2015 certified. Every unit is fully wired, charged with R-454B refrigerant and tested before shipping on computerized test stations. The refrigerant charge and the component numbers are verified by barcode scanning during assembly, and the run test data, such as the system pressures and the motor currents, is recorded. On request, this data can be retrieved from the serial number, an advantage for anyone who keeps a maintenance log. The unit is CSA certified to the UL 60335-2-40 and CAN\/CSA-C22.2 No 60335-2-40:22 standards.\u003c\/p\u003e\n\u003ch4\u003eThe standard protections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHermetic scroll compressor whose internal protection combines a high pressure relief valve and a temperature sensor, which shut it down if operating conditions become inadequate;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ehigh pressure switch\u003c\/strong\u003e that locks the unit out under abnormal conditions, until it is reset;\u003c\/li\u003e\n\u003cli\u003eloss of refrigerant pressure switch, supplied with the unit, for a safe compressor shutdown;\u003c\/li\u003e\n\u003cli\u003etotally enclosed outdoor fan motor, internally protected against overloads;\u003c\/li\u003e\n\u003cli\u003efilter drier or strainer to catch the impurities in the refrigeration circuit, and refrigerant detection (RDS) built in at the factory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eService access designed for technicians\u003c\/h3\u003e\n\u003cp\u003eEvery major component has its own \u003cstrong\u003eaccess panel:\u003c\/strong\u003e compressor, indoor coil, fan, controls, electric heat kit and filters. The electrical box is not housed in the compressor compartment, and the controls are mounted so that their panel can be removed for diagnostics without disturbing the normal system pressures. The fan assembly and the indoor coil assembly slide out of the cabinet for cleaning. According to YORK, no special training is required to replace a component, and the number of unique parts has been reduced, which makes sourcing easier.\u003c\/p\u003e\n\u003ch3\u003eThe data for the 4 ton three-phase PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eWhat it means\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePH3E48N00S31\u003c\/td\u003e\n\u003ctd\u003eYORK LX series, three-phase version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling (AHRI)\u003c\/td\u003e\n\u003ctd\u003e48,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eNet cooling capacity, fan heat deducted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h, COP of 3.7\u003c\/td\u003e\n\u003ctd\u003eHeating performance in mild weather\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e28,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eCapacity kept in cold weather, before the electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eSEER2 of 13.4, HSPF2 of 6.7 and EER2 of 11.1\u003c\/td\u003e\n\u003ctd\u003eRatings established under the requirements of the United States Department of Energy (DOE) and the AHRI methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,700 CFM (ft³\/min)\u003c\/td\u003e\n\u003ctd\u003eVolume of air delivered to the areas served\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003eDirect connection to the building's three-phase service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e45.75 in. x 51.25 in. x 50 in.\u003c\/td\u003e\n\u003ctd\u003eWidth, depth and height of the cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e482 lb\u003c\/td\u003e\n\u003ctd\u003eUseful figure for checking the roof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.0 dBA\u003c\/td\u003e\n\u003ctd\u003eStandardized sound rating of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStraightforward control\u003c\/h3\u003e\n\u003cp\u003eNo complex programming to pass on to the caretaker: the PH3 is driven by a 24 V \u003cstrong\u003estandard thermostat\u003c\/strong\u003e, either an electronic model that does not draw its power from the control circuit, or an electromechanical model, single stage in heating as in cooling. The thermostat wires land on the screw terminals of the refrigerant detection system. Inside, the cooling controls rely on a contactor and relays, the connectors are the MATE-N-LOK type, and all the internal wiring is colour coded and numbered. A status and diagnostic indicator light on the board, along with a demand defrost control with preloaded curves, round out the package.\u003c\/p\u003e\n\u003ch3\u003ePower supply and backup heat in three-phase\u003c\/h3\u003e\n\u003cp\u003eWithout a heat kit, the 4 ton three-phase PH3 calls for a circuit with a minimum circuit ampacity of 24.5 A, protected at 35 A maximum by an HACR breaker or a time-delay fuse, plus a field-supplied disconnect switch. Three three-phase 6HK kits are planned for this model, of 10, 15 and 20 kW. The last one heats in two stages, delivers 17.6 kW at 230 V and includes its own breakers. Single point wiring kits (S1-2SPWK032, S1-2SPWK034 or S1-2SPWK035, depending on the kit chosen) allow a single power supply.\u003c\/p\u003e\n\u003ch3\u003eWhat we check at every maintenance visit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eReplacement of the 1 in. filters, housed in the filter rack supplied with the three-phase models;\u003c\/li\u003e\n\u003cli\u003einspection and cleaning of the indoor coil and the blower wheel, pulled out of their housing if needed;\u003c\/li\u003e\n\u003cli\u003ecleaning of the outdoor coil and check of its protective grille;\u003c\/li\u003e\n\u003cli\u003echeck of the condensate pan and drain, whose 3\/4 in. NPT connection is rigidly fixed;\u003c\/li\u003e\n\u003cli\u003echeck of the electrical connections, the pressures and the operation in heating as in cooling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe bearings on the indoor fan motor and the outdoor fan motor are lubricated for life: they call for no annual lubrication, which shortens the task list by that much.\u003c\/p\u003e\n\u003ch2\u003eA single point of contact for the installation and the maintenance of your buildings\u003c\/h2\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen inc. sells, installs and maintains. For an owner or a manager, that means a single team from start to finish. It all begins with a \u003cstrong\u003efree on-site estimate:\u003c\/strong\u003e a review of the areas to be served, of the duct system, of the three-phase electrical service and of the location on the roof or at ground level. We calculate the load, prepare a clear quote, coordinate the lift and the access with you, then our crews install and commission the unit. After that, we can schedule the periodic maintenance of your equipment.\u003c\/p\u003e\n\u003cp\u003eOur crews travel quickly and efficiently everywhere on the island of Montreal, in Laval, in Longueuil as well as on the North Shore and the South Shore. For a plex, a small building or your offices, dial 514 316-2973 or use the online form at airgreen.ca.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080571172,"sku":"PH3E48N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_f92c6635-7b69-44a4-928c-b0827811f3de.png?v=1790086524","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-monobloc-york-ph3-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}