{"product_id":"thermopompe-monobloc-york-wp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WP 10 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003e10 tons of cooling and heating under the supervision of your BAS\u003c\/h2\u003e\n\u003cp\u003eIn a building supervised by a building automation system (BAS), every rooftop unit has to fit into the existing communication network. The YORK Sun Pro WP, a 10 ton packaged heat pump on R-454B fed by 208\/230 V three-phase, leaves the factory with its \u003cstrong\u003eBACnet MS\/TP communication card\u003c\/strong\u003e, its high static pressure IntelliSpeed drive and its refrigerant detection system. It has no \u003cstrong\u003eeconomizer\u003c\/strong\u003e — the fresh air comes from separate ventilation. AirGreen handles the supply, the installation and the follow-up in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eOne cabinet on the roof, one unit on the network\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the refrigeration circuit and the ventilation together under one outdoor shell: two scroll compressors on separate circuits, the coils, the supply fan and the controls. On the roof or at grade, it connects to the building's duct system, cools in two stages (50% and 100%) and switches to heating by reversing the cycle. For your operations team, it is a single piece of equipment, factory-tested, to tie into the BAS and to maintain.\u003c\/p\u003e\n\u003ch3\u003eA factory BACnet MS\/TP gateway, programmable to Modbus or N2\u003c\/h3\u003e\n\u003cp\u003eThe C control code designates the Smart Equipment option with communication: the full Smart Equipment control, paired with a \u003cstrong\u003eBACnet MS\/TP\u003c\/strong\u003e gateway programmable to Modbus or N2. The supply air, return air and outdoor air temperature sensors are factory-installed, and the board monitors the pressure switches of each circuit as well as the supply voltage. The LCD screen displays the fault codes; the USB port is used to pull the history and the start-up reports, and to update the software. The board also manages the minimum supply air setpoint (LLC) and compressor swapping; the control wiring has its own entries.\u003c\/p\u003e\n\u003ch3\u003eAHRI ratings and physical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAHRI net cooling: 116,000 BTU\/h, 11.2 EER, 15.2 IEER\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 104,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 60,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (187 to 252 V range)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eR-454B charge: 12 lb 0 oz and 11 lb 4 oz depending on the circuit\u003c\/li\u003e\n\u003cli\u003eDimensions and weight: 59 x 89 x 50.75 in., 1,135 lb operating\u003c\/li\u003e\n\u003cli\u003eFiltration: 4 disposable 24 x 20 x 2 in. filters\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 83 dB(A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh static pressure IntelliSpeed: reserve for your ducts\u003c\/h3\u003e\n\u003cp\u003eThe R code pairs the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with the high static pressure drive package: a 3 HP motor instead of the standard 2 HP, good for 3.45 bhp continuous, and a speed adjustable from 880 to 1,110 rpm. The YORK tables for the WP120 go up to 2.0 in. of water column of external static pressure, a useful margin for long duct runs. The drive then modulates the speed with the number of compressors or heating stages running, which is what the 15.2 IEER reflects, since it weighs performance at part load.\u003c\/p\u003e\n\u003ch3\u003eR-454B and built-in leak detection\u003c\/h3\u003e\n\u003cp\u003eAn A2L class refrigerant, \u003cstrong\u003eR-454B\u003c\/strong\u003e has a low global warming potential. The \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e (RDS) of the WP120 is factory-installed: its sensors, wired to the board, are placed to spot a leak in the cabinet quickly. As soon as the concentration reaches the equivalent of 25% of the lower flammability limit, the system raises the alarm and automatically starts diluting the refrigerant.\u003c\/p\u003e\n\u003ch3\u003eNo economizer, as a complement to your ventilation\u003c\/h3\u003e\n\u003cp\u003eThe A code of the outdoor air option means \"no economizer\": the fresh air stays with your air exchanger or your ventilation unit. If interior spaces call for cooling in winter, the low-ambient control provides comfort cooling down to 0 °F (-17.8 °C) outdoors; for a server room, you first have to check with the YORK applications department.\u003c\/p\u003e\n\u003cp\u003eShould outdoor air be brought in by the unit, the guide provides for the \"BAS Ready\" economizer (ready for the BAS) for the 50 in. cabinet (2EE04709825), the 208\/230 V power exhaust (2PE04704706) and the single (2EC0401) or dual (2EC0402) enthalpy controls. The minimum economizer opening can then be slaved to the drive frequency.\u003c\/p\u003e\n\u003ch3\u003eCompared with the R-410A XP120\u003c\/h3\u003e\n\u003cp\u003eWe also offer the XP120, the proven R-410A counterpart from the previous generation. The cabinet (59 x 89 x 50.75 in.), the weight (1,135 lb) and the rated airflow (3,300 CFM) are identical; here are the differences according to the YORK guides:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003eWP120 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXP120 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e116,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e111,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER and IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 and 15.2\u003c\/td\u003e\n\u003ctd\u003e11.0 and 14.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e104,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e102,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA and maximum protection at 208\/230 V\u003c\/td\u003e\n\u003ctd\u003e52.5 A and 60 A\u003c\/td\u003e\n\u003ctd\u003e47.6 A and 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl in the configuration offered\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP, Modbus and N2 card\u003c\/td\u003e\n\u003ctd\u003eStand-alone Smart Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant detection\u003c\/td\u003e\n\u003ctd\u003eFactory RDS\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith identical COPs (3.5 and 2.25), the WP120 takes the lead on cooling and arrives ready for the BAS; the XP120 suits a building run by thermostat or a fleet already on R-410A.\u003c\/p\u003e\n\u003ch3\u003eElectrical connection and backup heat\u003c\/h3\u003e\n\u003cp\u003eAs delivered, the unit calls for a circuit with a \u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e (MCA) of 52.5 A, protected by a dual-element time-delay fuse or an HACR breaker of 60 A maximum, at 208 V as at 230 V; adding a power exhaust brings those values to 58 A and 70 A. The power feed enters at a single point, on the side or underneath, and the disconnect, not supplied from the factory, is installed in the field.\u003c\/p\u003e\n\u003cp\u003eThe 10 ton size accepts four electric heat kits, all two-stage and connected to the same power point as the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eE18 (2TP04531825): 13.5 kW at 208 V, 18 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE24 (2TP04532425): 18 kW at 208 V, 24 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE36 (2TP04533625): 25.5 kW at 208 V, 34 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE54 (2TP04525425): 40.6 kW at 208 V, 54 kW at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum airflow is 3,000 CFM, or 3,500 CFM with the E54. At 208 V, the MCA reaches 99.4 A with the E18 and 141 A with the E36, for example. The choice of kit follows your heat load and the spare capacity of your electrical service.\u003c\/p\u003e\n\u003ch3\u003eWhat to plan before the lift\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYORK roof curbs with insulated deck, shipped knocked down: 1RC0470 (8 in.) or 1RC0471 (14 in.); the 1RC0472 adapter (10 in.) sits on the existing curb of a Sunline from 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003ePerimeter base rails drilled for the crane; on four supports, the load ranges from 209 to 369 lb depending on the corner.\u003c\/li\u003e\n\u003cli\u003eClearances: 36 in. in front, behind and on the left, 12 in. on the right, 72 in. above.\u003c\/li\u003e\n\u003cli\u003eSide connection: the installer moves the two factory covers to the bottom openings, without cutting a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAirGreen coordinates your project with the integrator and the electrician\u003c\/h2\u003e\n\u003cp\u003eAirGreen's \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e runs from the roof to the supervision station: ducts and static pressure, heat load, three-phase service, existing curb, crane access and the protocol of your BAS. The quote then compares the WP120 and the XP120.\u003c\/p\u003e\n\u003cp\u003eAt installation, we coordinate the crane, the electrician and your integrator, adjust the pulley and the drive to the measured airflow, then commission the board on the BAS network. Our technicians then take care of the planned maintenance and, from Montreal, get quickly to Laval, Longueuil, the North Shore and the South Shore. To book your estimate visit, reach us at 514 316-2973 or write to us from airgreen.ca.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56368011116836,"sku":"WP120C00R2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_f831ce39-d1fa-49c8-9e12-1c6d30b29199.png?v=1790086979","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-monobloc-york-wp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}