{"product_id":"thermopompe-monobloc-york-wye-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WYE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eWhen the electricity bill matters: the 5 ton high-efficiency version\u003c\/h2\u003e\n\u003cp\u003eIf you are the one paying the electricity for your business or your building, the purchase price of a rooftop unit is only part of the calculation. The unit will run for many years, in cooling as well as in heating, and a gain in efficiency carries over to every hour it operates. Model WYE06A2B1AB5A111A1 is the \u003cstrong\u003ehigh-efficiency\u003c\/strong\u003e version of the 5 ton YORK Sun Core packaged heat pump (60,000 BTU\/h nominal), in 208\/230 V three-phase and on R-454B refrigerant. AirGreen helps you compare it with the standard WQE06 version before you decide, for buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWYE06 and WQE06 side by side\u003c\/h3\u003e\n\u003cp\u003eBoth models share the same cabinet and the same design. Here are their main figures, taken from the YORK technical guide:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eWYE06 (high efficiency)\u003c\/th\u003e\n\u003cth\u003eWQE06 (standard efficiency)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e57,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 47 °F\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 17 °F\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e14.3\u003c\/td\u003e\n\u003ctd\u003e14.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in cooling (AHRI rating)\u003c\/td\u003e\n\u003ctd\u003e4.9 kW\u003c\/td\u003e\n\u003ctd\u003e4.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 47 °F\u003c\/td\u003e\n\u003ctd\u003e4.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 17 °F\u003c\/td\u003e\n\u003ctd\u003e4.1 kW\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,650 CFM\u003c\/td\u003e\n\u003ctd\u003e1,550 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum circuit ampacity (MCA) at 208 V, without backup heat\u003c\/td\u003e\n\u003ctd\u003e29 A\u003c\/td\u003e\n\u003ctd\u003e25.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e80.0 dBA\u003c\/td\u003e\n\u003ctd\u003e77.8 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e653 lb\u003c\/td\u003e\n\u003ctd\u003e627 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe MCA values correspond to the medium static pressure configuration of both models, without a powered convenience outlet.\u003c\/p\u003e\n\u003ch3\u003eHow to read these ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e seasonal cooling efficiency, that is the heat removed per unit of electricity consumed over a typical season.\u003c\/li\u003e\n\u003cli\u003eEER2: cooling efficiency at full load, measured at a high, fixed outdoor temperature; useful for judging performance in hot weather.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2:\u003c\/strong\u003e seasonal heating efficiency, calculated over a typical heating season.\u003c\/li\u003e\n\u003cli\u003eCOP: the instantaneous ratio between the heat delivered and the electricity consumed at a given outdoor temperature. At 47 °F (8.3 °C), a COP of 3.6 means 3.6 units of heat for every unit of electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the comparison shows\u003c\/h3\u003e\n\u003cp\u003eThe WYE06 draws a little more at full load, but it also delivers more capacity in cooling and in heating. Efficiency is measured by the ratio between those two values, and the high-efficiency version earns a better rating on every count: SEER2, EER2, HSPF2 and COP. The advantage holds in cold weather: at 17 °F (-8.3 °C), it delivers 30,000 BTU\/h with a COP of 2.2. When the backup heat is called on, every extra BTU delivered by the heat pump cuts back its contribution by that much, and those electric elements only turn electricity into heat.\u003c\/p\u003e\n\u003cp\u003eThe comparison also shows three points to plan for: a slightly larger electrical circuit, 26 lb more on the roof and a higher sound rating. We take them into account, especially when the unit sits close to windows or to neighbouring dwellings. The real difference on your bill depends on your operating hours, your rate and the load of your building; we therefore assess it from your own situation rather than with a generic percentage.\u003c\/p\u003e\n\u003ch3\u003eWhen the high-efficiency version is worth it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe space is occupied long hours, every day, in cooling as well as in heating.\u003c\/li\u003e\n\u003cli\u003eThe owner pays for the electricity directly and is keeping the building for the long term.\u003c\/li\u003e\n\u003cli\u003eThe heat pump carries a large share of the heating, which brings its COP of 3.6 and 2.2 into play.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a space occupied few hours, or when the purchase budget comes first, the WQE06 can be enough. We compare both options with you, figures in hand.\u003c\/p\u003e\n\u003ch3\u003eThe settings that count as much as the rating\u003c\/h3\u003e\n\u003cp\u003eAn oversized unit starts and stops more often, which wastes part of its efficiency. We therefore begin with a load calculation. According to the YORK nomenclature, this model carries the medium static pressure option: a belt-driven fan, a 2.4 HP three-phase motor and an adjustable drive pulley, which we set to the target airflow after measuring the static pressure of your ducts.\u003c\/p\u003e\n\u003cp\u003eThanks to the energy consumption tracking built into the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, operation can be matched to the real schedule and occupancy of the building. The control can also lock out the compressor when free cooling is available with an economizer, and its fan delays are programmed separately in heating and in cooling. The LCD display, the USB port and, depending on the model code, the BACnet MS\/TP, Modbus and N2 communication card make monitoring easier. Finally, regular maintenance of the filters and the coils helps the unit keep its original performance.\u003c\/p\u003e\n\u003ch3\u003eA packaged unit assembled and tested at the factory\u003c\/h3\u003e\n\u003cp\u003eIn a packaged heat pump, compressor, coils, fan and control share a single outdoor cabinet, installed on the roof or on the ground and connected to the supply and return ducts. The refrigerant circuit is not joined in the field between two units: it is assembled at the factory, and every unit is configured and run-tested before delivery. The single scroll compressor, designed with fewer moving parts, contributes to a quiet, reliable, easy-to-service and efficient system.\u003c\/p\u003e\n\u003ch3\u003eEvery figure for the WYE06 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEfficiency ratings: 14.3 SEER2, 6.9 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003eCOP: 3.6 at 47 °F (8.3 °C) and 2.2 at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating: 56,000 BTU\/h at 47 °F (8.3 °C) and 30,000 BTU\/h at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,650 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eOverall dimensions (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 653 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 80.0 dBA\u003c\/li\u003e\n\u003cli\u003eField-installed backup heat: 6.5, 10.5 or 16 kW kits at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSame dimensions, same roof curb\u003c\/h3\u003e\n\u003cp\u003eChoosing high efficiency does not complicate the installation. The WYE06 has the same dimensions as the WQE06 and uses the same 14 in. or 24 in. YORK roof curbs, the same hail guard and the same economizers. It also sits on a good number of existing roof curbs thanks to its full perimeter base rail. You find the construction shared across the line: thermostatic expansion valve, filter drier, high and low pressure switches, copper and aluminum coils, embossed top and powder paint rated for 750 hours of salt spray, all rated to cool up to 125 °F (52 °C).\u003c\/p\u003e\n\u003ch2\u003eChoosing the right efficiency level with AirGreen\u003c\/h2\u003e\n\u003cp\u003eBetween the standard version and the high-efficiency version, the right choice depends on your building, your occupancy hours and your electrical service. During the free on-site estimate, we run the load calculation, check the roof curb, the ducts and the electrical entrance, then we lay out both options transparently. Once your choice is made, we install the unit, commission it and maintain it. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we work quickly and efficiently.\u003c\/p\u003e\n\u003cp\u003eOur on-site estimates are free everywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore. Reach us at 514 316-2973 or through the form on airgreen.ca to compare both versions in your own building.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367208038692,"sku":"WYE06A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_ef287294-da26-4414-be0f-81aa1f9d9ae4.png?v=1790086721","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-monobloc-york-wye-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}