{"product_id":"thermopompe-monobloc-york-xp-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 7.5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eThe 7.5 ton Sun Pro capacity, connected to the 575 V network of your industrial building\u003c\/h2\u003e\n\u003cp\u003eIn a factory, a warehouse or a shop supplied at 575 V, cooling the offices, the break room or a light production area should not call for a step-down transformer. This YORK Sun Pro packaged heat pump delivers exactly the same capacity as the 208\/230 V version, but it is built for \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e. Our teams take care of the lift, the \u003cstrong\u003ecommissioning\u003c\/strong\u003e and the maintenance, so your maintenance staff does not have to get to know a new unit on their own. We work in industrial buildings in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 575 V version changes\u003c\/h3\u003e\n\u003cp\u003eThe YORK guide allows an applied voltage from 540 to 630 V for this version. The connection is made directly on the building's 575 V distribution, and the electrical accessories follow the same voltage: the electric heat kits of 9, 18, 24 and 36 kW and the powered exhaust fan are available in 575 V. Performance, for its part, stays identical to that of the 208\/230 V model: same net cooling, same EER and IEER ratings, same airflow.\u003c\/p\u003e\n\u003cp\u003eOne point deserves your attention: this unit is meant for human comfort. For a process application, such as a server room or an electrical room, YORK recommends consulting its applications department. We take that step for you when your project comes close to it.\u003c\/p\u003e\n\n\u003ch3\u003eA single cabinet on the roof, the plant floor stays clear\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in one outdoor cabinet everything a split system spreads between the indoor and the outdoor side: compressors, coils, fans and control. Installed on a roof curb, a pad or a steel structure, it feeds the ducts that serve your offices or your work area, and it provides both cooling and heat pump heating. No equipment clutters the production floor, and all the work is done outside.\u003c\/p\u003e\n\u003cp\u003eThe unit arrives charged with \u003cstrong\u003eR-410A\u003c\/strong\u003e, wired, piped and factory tested. This previous-generation refrigerant is a proven technology, well known to refrigeration technicians.\u003c\/p\u003e\n\n\u003ch3\u003eThe performance data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e7.5 tons (90,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e92,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER \/ IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 \/ 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e575 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003e2 scroll, two stages (50% \/ 100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e83 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eThe configuration as delivered\u003c\/h3\u003e\n\u003cp\u003eThe XP090C00R5B1BAA1A2 model includes an \u003cstrong\u003eIntelliSpeed variable-speed drive\u003c\/strong\u003e with a high static pressure drive, an economizer with a barometric relief damper, a phase monitor, the stand-alone Smart Equipment control and standard coils. It has no factory service option (no disconnect switch and no convenience receptacle) and no factory-installed electric heat: the disconnect switch and, if needed, the heat kit are added in the field. It ships with 2 in. disposable filters.\u003c\/p\u003e\n\n\u003ch3\u003eA build made for an industrial roof\u003c\/h3\u003e\n\u003cp\u003eBefore leaving the factory, every Sun Pro unit goes through computer-automated tests: refrigerant charge and pressure, electrical current and full operation. The galvanized steel cabinet receives a powder paint that has passed a 750 hour salt spray test, and the full perimeter base rails protect the unit during transport and lifting, with forklift slots on three sides. Aluminum-faced and elastomeric rubber insulation, used throughout the cabinet, supports indoor air quality. Finally, the built-in low-ambient control keeps cooling down to 0 °F (-17.8 °C) outdoors, an advantage when equipment gives off heat in your offices or your control room in the middle of winter.\u003c\/p\u003e\n\n\u003ch3\u003eOur commissioning, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCheck of the supply voltage within the 540 to 630 V range and of the phase order, watched by the phase monitor.\u003c\/li\u003e\n\u003cli\u003eCheck of the clearances required by YORK: 72 in. clear above the unit, 36 in. on the front, back and left sides, and 12 in. on the right side.\u003c\/li\u003e\n\u003cli\u003eAdjustment of the belt drive and of the IntelliSpeed speeds to the actual static pressure of your ducts, to deliver the intended airflow.\u003c\/li\u003e\n\u003cli\u003eSetup of the economizer: changeover setpoint for free cooling mode and minimum fresh air position.\u003c\/li\u003e\n\u003cli\u003eProgramming of the Smart Equipment control: thermostat or zone sensor, fan delays, compressor lockout on low outdoor temperature if needed.\u003c\/li\u003e\n\u003cli\u003eExtraction of the start-up report through the USB port and a walkthrough for your maintenance manager.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003ePlanned maintenance suited to an industrial setting\u003c\/h3\u003e\n\u003ch4\u003eFilters and air quality\u003c\/h4\u003e\n\u003cp\u003eThe unit uses four 24 x 20 x 2 in. filters. In a dusty environment, 2 in. MERV 8 or 4 in. MERV 13 pleated filters can replace the disposable filters, and a dirty filter switch is available to signal an abnormal pressure drop.\u003c\/p\u003e\n\u003ch4\u003eCoils, fan and condensate\u003c\/h4\u003e\n\u003cp\u003eService windows in the condenser walls allow the coils to be cleaned without heavy disassembly. The motor and fan assembly slides out of the cabinet, and the non-corrosive condensate pan is pulled out from the back. The hinged panels open without tools, then are screwed shut again after each visit to block access by unauthorized people.\u003c\/p\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cp\u003eAt every visit, we review the fault history recorded by the Smart Equipment board. Thanks to the two independent refrigerant circuits, a fault on one circuit locks out only the compressor tied to it, after three trips in two hours.\u003c\/p\u003e\n\n\u003ch3\u003eAccessories that earn their place in an industrial setting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil guard and hail guard kit.\u003c\/li\u003e\n\u003cli\u003eSmoke detectors for the supply or return air.\u003c\/li\u003e\n\u003cli\u003eCO2 sensor, which drives the economizer open when the level goes above the preset limit.\u003c\/li\u003e\n\u003cli\u003eBurglar bars for the duct openings of the roof curb.\u003c\/li\u003e\n\u003cli\u003eRoof curb of 8 in. or 14 in., or transition curb for an older Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eYour industrial project in the hands of our teams\u003c\/h2\u003e\n\u003cp\u003eWe start with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which surveys the loads, the condition of the ducts, the 575 V distribution and the access to the roof or to the pad. We confirm the sizing, plan the crane lift using the base rails with their lifting holes, install the unit with our own teams and carry out the commissioning described above. A planned maintenance contract then helps keep the unit reliable, season after season.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, AirGreen serves the industrial parks and commercial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore, with fast and efficient service calls. Call us at 514 316-2973 or write to us through the form on airgreen.ca to schedule your visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217410340,"sku":"XP090C00R5B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_e5f8132a-afbd-4131-a438-869be02b7882.png?v=1790086770","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-monobloc-york-xp-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}