{"product_id":"thermopompe-monobloc-york-xqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eStore or office on 208\/230 V three-phase: 3 tons on R-410A in a 32.5 in. cabinet\u003c\/h2\u003e\n\u003cp\u003eIf your store or your office needs about 3 tons of cooling, if the electrical service is 208\/230 V three-phase and you prefer to stay on R-410A, the 3 ton YORK Sun Core XQE answers that profile. This \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e of 36,000 BTU\/h nominal, rated 13.4 SEER2, sits in the short 32.5 in. cabinet and comes with a belt-driven medium static pressure blower. At AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we sell and install it in Montreal as well as in Laval and Longueuil, on the North Shore as on the South Shore.\u003c\/p\u003e\n\u003cp\u003eThe factory configuration of the XQE04A2B1AA1A111A2 model stays simple: Smart Equipment control, standard coils, no economizer, no disconnect switch and no built-in heat. In the field we add only what your space requires.\u003c\/p\u003e\n\u003ch3\u003eThe whole system outdoors, nothing on the sales floor\u003c\/h3\u003e\n\u003cp\u003eCompressor, coils, fans, filters and control share a single outdoor cabinet, installed on the roof or at ground level, then tied into the \u003cstrong\u003educt\u003c\/strong\u003e system. In summer, the unit cools; in winter, it heats in heat pump mode, with backup heat from an electric kit added in the field. Nothing encroaches on the sales floor or on the drop ceiling, and maintenance is done outside, without disturbing your customers.\u003c\/p\u003e\n\u003ch3\u003eCapacities, ratings and size at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 35,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 34,200 BTU\/h, COP of 3.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 18,500 BTU\/h, COP of 2.12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 standard:\u003c\/strong\u003e 13.4 SEER2, 6.7 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevious standard:\u003c\/strong\u003e 14.0 SEER and 8.1 HSPF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 1,238 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 208\/230 V, three-phase, 60 Hz (allowable voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth x depth x height:\u003c\/strong\u003e 48.9 x 74.1 x 32.5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 529 lb operating, 542 lb shipping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 78.4 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e two 16 x 25 x 2 in. disposable filters (MERV 4 as delivered)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories specific to the 32.5 in. cabinet\u003c\/h3\u003e\n\u003cp\u003eOn the same footprint, the 4 and 5 ton XQE reach 40.6 in. in height; the 3 ton version stops at 32.5 in., the lowest cabinet of this size. Behind a low parapet, it stays more discreet. This short cabinet has its own accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail guard 1HG0419:\u003c\/strong\u003e a louvred panel set in front of the outdoor coil to protect its fins from hail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal flow economizer 2EE04707024:\u003c\/strong\u003e for ducts connected from the side, since the unit can be converted in the field to a horizontal connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged panel 1HD0401 for filter access:\u003c\/strong\u003e the companion to that economizer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBelt-driven blower: the margin it gives your ducts\u003c\/h3\u003e\n\u003cp\u003eOn the 3 to 5 ton XQE, the base option is a direct-drive blower. The B in the eighth position of the model number stands instead for the \u003cstrong\u003emedium static pressure\u003c\/strong\u003e option: a double-inlet centrifugal wheel, belted to a 2.4 HP three-phase motor. Set by its variable-pitch drive pulley (1VL34), the blower speed runs from 792 to 1,208 rpm.\u003c\/p\u003e\n\u003cp\u003eAccording to the YORK tables, moving 1,200 CFM against 1.0 in. w.c. of external static pressure, in bottom connection, takes 1,191 rpm, which this option delivers. At the same pressure, the base direct-drive blower tops out at 872 CFM. In an office with long, elbowed ducts, that reserve helps hold the intended airflow; at start-up, we measure the pressure and set the pulley accordingly.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment in stand-alone mode and proven mechanics\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Equipment\u003c\/strong\u003e is supplied here without a communication card, which suits a space with no building management system. A 24 V thermostat or a zone sensor is enough to drive it, and its three air sensors are already fitted at the factory. A CO2 sensor can also be connected to it: combined with an economizer, it adjusts the fresh air intake to occupancy. Its low ambient function lets the unit cool even when it is only 40 °F (4.4 °C) outside, an advantage in spring, when computers and lighting warm up the offices.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003escroll compressor\u003c\/strong\u003e is mounted on rubber grommets and internally protected against overheating and overcurrent. The coils pair internally grooved copper tubes with aluminum fins, and the blower compartment is insulated with 1\/2 in. fibreglass.\u003c\/p\u003e\n\u003ch3\u003eSame cabinet, two refrigerants: R-410A or R-454B\u003c\/h3\u003e\n\u003cp\u003eHere are the two versions of this 3 ton format:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eXQE04 (R-410A)\u003c\/th\u003e\n\u003cth\u003eWQE04 (R-454B)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e18,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ HSPF2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e13.4 \/ 6.7 \/ 12.0\u003c\/td\u003e\n\u003ctd\u003e14.0 \/ 6.7 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and weight\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 32.5 in., 529 lb\u003c\/td\u003e\n\u003ctd\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower on the version offered\u003c\/td\u003e\n\u003ctd\u003eMedium static pressure\u003c\/td\u003e\n\u003ctd\u003eHigh static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe WQE04 posts a slightly higher SEER2 and EER2 and heats a little more at 17 °F; it uses R-454B, an A2L refrigerant with a low global warming potential, and the version offered includes a refrigerant detection system (RDS). The XQE04 stays on R-410A, a proven technology from the previous generation, and its rating under the previous standard makes the comparison with an older unit easier. If your other equipment runs on R-410A, the XQE04 is the obvious choice; if the climate impact of the refrigerant comes first, we will propose the WQE04.\u003c\/p\u003e\n\u003ch3\u003eThe three-phase electrical service and the heat kits\u003c\/h3\u003e\n\u003cp\u003eFor this configuration with no electric backup, the YORK guide gives an MCA (\u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e) of 20.2 A at 208 V and 20.5 A at 230 V; the maximum protection is 30 A (time-delay fuse or HACR breaker). Three heat kits are installed in the field:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2EK04510625: 6.5 kW at 230 V (4.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511125: 10.5 kW at 230 V (7.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511625: 16 kW at 230 V (12 kW at 208 V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 16 kW kit brings the MCA to 68.6 A at 230 V and the maximum protection to 70 A: we therefore check your panel first. The unit arrives without a factory disconnect switch; we install one, sized from the nameplate, and a bottom power entry kit brings the supply in without piercing the membrane anywhere else.\u003c\/p\u003e\n\u003ch3\u003eBefore installation on a commercial roof\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSurvey the existing curb or plan a new 14 or 24 in. YORK curb, to which the ducts can be connected before the unit arrives.\u003c\/li\u003e\n\u003cli\u003eCheck the roof structure: the guide gives 127 to 137 lb at each corner of the unit.\u003c\/li\u003e\n\u003cli\u003eClear the space around the unit: 36 in. in front, 18 in. behind (36 in. with an economizer or a powered exhaust), 12 in. on the left, 18 in. on the right and 72 in. above for the air discharge.\u003c\/li\u003e\n\u003cli\u003ePlan the crane lift: the lifting shackles hook directly to the unit's base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen takes care of your 3 ton unit, from the survey to the maintenance\u003c\/h2\u003e\n\u003cp\u003eDuring the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure what drives the sizing: the actual load of the space, the static pressure of the ducts, the electrical service and the roof curb. We then recommend the XQE04 or the WQE04, with the right heat kit. We arrange the crane, connect the unit, balance the airflow and carry out the commissioning; our technicians come back through the seasons for the maintenance: filters, coils, belt and pulley.\u003c\/p\u003e\n\u003cp\u003eWe work in Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore. To set up your free on-site estimate, a call to 514 316-2973 or a request through the form on airgreen.ca is all it takes: we will offer you a visit date without delay.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367633858852,"sku":"XQE04A2B1AA1A111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_1948b118-e48d-4895-bc47-1e9c763479a1.png?v=1790086978","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-monobloc-york-xqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}