{"product_id":"thermopompe-murale-durastar-standard-24000-btu-r410a","title":"DURASTAR Standard Wall-Mounted Heat Pump | 24000 BTU - R410A","description":"\u003ch2\u003eA 24,000 BTU unit designed first for summer, with effective supplemental heating\u003c\/h2\u003e\u003cp\u003eNot every home needs a heat pump designed for -30 °C. When the existing heating system works well and the priority is cooling a large room during heat waves, the \u003cstrong\u003eDURASTAR Standard Wall-Mounted Heat Pump | 24,000 BTU - R410A\u003c\/strong\u003e offers the greatest cooling reserve among our DuraStar 24,000 BTU models: up to \u003cstrong\u003e27,841 BTU\/h\u003c\/strong\u003e according to its certified range. In winter, it reduces heating costs for a good part of the season.\u003c\/p\u003e\u003cp\u003eIts certified ratings are \u003cstrong\u003e21.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e13.0 EER2\u003c\/strong\u003e, and \u003cstrong\u003e8.5 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified, but without the cold-climate designation. It operates in heating mode down to \u003cstrong\u003e-25 °C\u003c\/strong\u003e and appears on Hydro-Québec's LogisVert list with a \u003cstrong\u003e$870 rebate\u003c\/strong\u003e, a more modest amount than that offered for cold-climate models.\u003c\/p\u003e\u003ch3\u003eCertificate values\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCooling: \u003cstrong\u003e24,000 BTU\/h\u003c\/strong\u003e, range from 8,038 to 27,841 BTU\/h\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e8 °C\u003c\/strong\u003e: \u003cstrong\u003e26,000 BTU\/h\u003c\/strong\u003e, range from 6,856 to 30,356 BTU\/h, COP of 3.14\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e17,400 BTU\/h\u003c\/strong\u003e nominal capacity, up to 23,471 BTU\/h maximum capacity, \u003cstrong\u003eCOP of 2.28\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e16,700 BTU\/h\u003c\/strong\u003e with a \u003cstrong\u003eCOP of 1.90\u003c\/strong\u003e, and up to 19,542 BTU\/h maximum capacity\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese values come from certificate \u003cstrong\u003eAHRI 207787133\u003c\/strong\u003e, published by NEEP. The certified data stops at -15 °C, and the DuraStar manual indicates an operating limit of -25 °C in heating mode for Standard models.\u003c\/p\u003e\u003ch3\u003eWho this model is right for\u003c\/h3\u003e\u003cp\u003eWe recommend it when cooling is the priority: a large south- or west-facing living room, a room with extensive glazing, or a finished basement that becomes humid in summer. It is also suitable for homes where the primary heating system provides satisfactory performance and the heat pump is used to reduce energy bills in the fall, spring, and during mild winter days. At 8 °C, with a COP of 3.14, every kilowatt-hour consumed provides more than three kilowatt-hours of heat.\u003c\/p\u003e\u003cp\u003eIf heating during extremely cold weather is your priority, we would instead direct you toward a cold-climate model: the Standard 24,000 BTU with R-454B or the Sirius Heat models retain more of their capacity in winter, have a higher HSPF2 rating, and qualify for a larger rebate. Its 8.5 HSPF2 rating is also the lowest in our DuraStar wall-mounted selection. We prefer to say this clearly so your choice matches your actual needs.\u003c\/p\u003e\u003ch3\u003eCooling a large room\u003c\/h3\u003e\u003cp\u003eWith 24,000 certified BTU\/h and a reserve of up to 27,841 BTU\/h, the unit quickly catches up with heat accumulated at the end of the day. The 13.0 EER2 rating, measured at 35 °C, confirms good efficiency during the hottest days. The \u003cstrong\u003eECO\/GEAR\u003c\/strong\u003e function then reduces consumption in cooling mode, while the \u003cstrong\u003eGentle\u003c\/strong\u003e function redirects the airflow when it becomes too direct.\u003c\/p\u003e\u003ch3\u003eThe $870 LogisVert rebate\u003c\/h3\u003e\u003cp\u003eThe system carries \u003cstrong\u003eENERGY STAR ID 2410731\u003c\/strong\u003e and appears on the LogisVert list with an \u003cstrong\u003e$870 rebate\u003c\/strong\u003e, according to the list in effect on the installation date. We confirm this amount in writing before signing and prepare the documents for your application. Our page on Hydro-Québec's \u003ca href=\"\/en\/pages\/subvention-thermopompes-efficaces-dhydro-quebec\"\u003eefficient heat pump rebate\u003c\/a\u003e outlines the program's general conditions.\u003c\/p\u003e\u003ch2\u003eLarge room, large condenser: the steps to a successful installation\u003c\/h2\u003e\u003cp\u003eA 24,000 BTU unit requires careful preparation, regardless of its intended use.\u003c\/p\u003e\u003ch3\u003eThe indoor unit\u003c\/h3\u003e\u003cp\u003eThe wall-mounted unit measures \u003cstrong\u003e42.60 x 9.21 x 13.27 inches\u003c\/strong\u003e and weighs 30.0 pounds. With this system, its sound level ranges from \u003cstrong\u003e28 to 48 dB(A)\u003c\/strong\u003e, and its fan offers three settings of \u003cstrong\u003e382, 459, and 601 CFM\u003c\/strong\u003e. We secure it to the framing on a wall that allows the airflow to cover the room, with a drainage slope for condensate, which is abundant in summer. The vertical louver oscillates automatically; the horizontal direction is adjusted manually. The remote also offers \u003cstrong\u003eFollow Me\u003c\/strong\u003e, \u003cstrong\u003eSleep\u003c\/strong\u003e, \u003cstrong\u003eTurbo\u003c\/strong\u003e, \u003cstrong\u003eSilence\u003c\/strong\u003e, the \u003cstrong\u003eClean\u003c\/strong\u003e function, a timer, and freeze protection at 8 °C. An alert code appears in the event of a refrigerant leak. Wi-Fi is not built in; DuraStar indicates that its indoor units are compatible with the 24 V DR24VINT2 interface, which accepts a third-party Wi-Fi thermostat.\u003c\/p\u003e\u003ch3\u003eThe outdoor unit\u003c\/h3\u003e\u003cp\u003eThe condenser measures \u003cstrong\u003e37.25 x 16.13 x 31.88 inches\u003c\/strong\u003e, weighs \u003cstrong\u003e124.8 pounds\u003c\/strong\u003e, and produces \u003cstrong\u003e60 dB(A)\u003c\/strong\u003e. We install it on a ground stand or stable base, above the snow line, away from bedroom windows and neighboring decks. The base pan heater and corrosion-resistant coating come standard, and DuraStar recommends keeping the unit powered continuously at 0 °C and below.\u003c\/p\u003e\u003ch3\u003eThe refrigerant lines\u003c\/h3\u003e\u003cp\u003eThe lines are \u003cstrong\u003e3\/8 and 5\/8 inch\u003c\/strong\u003e, precharged for 25 feet, with a maximum length of \u003cstrong\u003e164 feet\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong\u003e82 feet\u003c\/strong\u003e. Beyond the precharge length, 0.32 ounces of refrigerant is added per foot. This length provides considerable flexibility for positioning the condenser away from living areas. The installation remains fully exposed, without opening an interior wall, and a finished line set cover can be added.\u003c\/p\u003e\u003ch3\u003eElectrical requirements\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e208-230 V\u003c\/strong\u003e power supply, \u003cstrong\u003e22 A MCA\u003c\/strong\u003e, and a \u003cstrong\u003e30 A circuit breaker\u003c\/strong\u003e, on a dedicated circuit. We check the electrical service capacity and available panel space during the site visit.\u003c\/p\u003e\u003ch3\u003eR-410A refrigerant\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eR-410A\u003c\/strong\u003e is a nonflammable, widely used refrigerant. According to ENERGY STAR, its global warming potential is 2,088, compared with 470 for the R-454B used in new-generation units.\u003c\/p\u003e\u003ch3\u003eWhat is normal\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eA five- to ten-minute \u003cstrong\u003edefrost cycle\u003c\/strong\u003e in cold weather, with white vapor at the condenser and a pause in indoor heating.\u003c\/li\u003e\n\u003cli\u003eA three-minute delay when the compressor restarts.\u003c\/li\u003e\n\u003cli\u003eReduced heating capacity during extremely cold weather, followed by heating shutdown below -25 °C: your primary system then takes over.\u003c\/li\u003e\n\u003cli\u003eA slight hissing sound and plastic cracking noises.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAn indoor water leak, a persistent error code, or a tripped circuit breaker requires shutting off the unit and calling our \u003ca href=\"\/en\/pages\/service-de-reparation-thermopompe-murale-grand-montreal\"\u003erepair service\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eClean the \u003cstrong\u003eindoor filters\u003c\/strong\u003e every two weeks, especially during the cooling season. Keep the condenser clear and schedule annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e for the coils, drain, and electrical connections.\u003c\/p\u003e\u003ch3\u003eAirGreen, honest advice\u003c\/h3\u003e\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eMontreal\u003c\/strong\u003e company that has installed wall-mounted heat pumps for more than fifteen years in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. We hold RBQ licences for ventilation, refrigeration, and electrical work, as well as \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, and the quote is provided in writing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the DURASTAR Standard Wall-Mounted Heat Pump | 24,000 BTU - R410A: we will determine whether this cooling-focused model meets your needs or whether a cold-climate model would serve you better.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Durastar","offers":[{"title":"Default Title","offer_id":56308981825828,"sku":"DRA1U24S1B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_DURASTAR_STANDARD_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_8e91846d-d0a3-43a8-b386-b95c01a47279.png?v=1789646689","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-durastar-standard-24000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}