{"product_id":"thermopompe-murale-durastar-standard-6000-btu-r410a","title":"DURASTAR Standard Wall-Mounted Heat Pump | 6000 BTU - R410A","description":"\u003ch2\u003eA 6,000 BTU indoor unit paired with a 9,000 BTU condenser: small-room comfort with capacity to spare\u003c\/h2\u003e\u003cp\u003eFor a child’s bedroom, home office, or small studio, an oversized unit cycles on and off and leaves the air humid. An undersized unit struggles during heat waves and extreme cold. The \u003cstrong\u003eDURASTAR Standard Wall-Mounted Heat Pump | 6,000 BTU - R410A\u003c\/strong\u003e solves this dilemma in a distinctive way: its DRAW06F1 indoor unit is certified with the \u003cstrong\u003eDRA1U09S1B\u003c\/strong\u003e outdoor unit, the same one used by the series’ 9,000 BTU system. The result is a discreet small-format system with useful reserve capacity, reaching up to \u003cstrong\u003e10,000 BTU\/h\u003c\/strong\u003e at maximum capacity at -8 °C and up to \u003cstrong\u003e11,500 BTU\/h\u003c\/strong\u003e in cooling.\u003c\/p\u003e\u003cp\u003eIts certified ratings are \u003cstrong\u003e23.5 SEER2\u003c\/strong\u003e, \u003cstrong\u003e15.0 EER2\u003c\/strong\u003e, and \u003cstrong\u003e12.0 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold climate designation\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eCertificate values\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCooling: \u003cstrong\u003e6,000 BTU\/h\u003c\/strong\u003e, range from 4,900 to 11,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e8 °C\u003c\/strong\u003e: 7,000 BTU\/h, range from 3,400 to 11,400 BTU\/h, COP of 3.73\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e7,500 BTU\/h\u003c\/strong\u003e nominal capacity, up to 10,000 BTU\/h maximum capacity, \u003cstrong\u003eCOP of 2.50\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e7,100 BTU\/h\u003c\/strong\u003e, \u003cstrong\u003eCOP of 1.84\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese values come from certificate \u003cstrong\u003eAHRI 210568097\u003c\/strong\u003e, published by NEEP. The system’s certified data ends at -15 °C. According to the DuraStar manual, Standard models provide heating down to \u003cstrong\u003e-25 °C\u003c\/strong\u003e; below that temperature, the existing baseboard heaters provide the heating on their own.\u003c\/p\u003e\u003ch3\u003eQuiet, even at full speed\u003c\/h3\u003e\u003cp\u003eWith this system, the indoor unit operates between \u003cstrong\u003e20.5 and 38.5 dB(A)\u003c\/strong\u003e. Its maximum sound level is the lowest of all the DuraStar wall-mounted heat pumps we offer: even at the highest setting, it remains quieter than several units operating at medium speed. This is a clear advantage in a bedroom. The fan offers three settings of \u003cstrong\u003e141, 176, and 247 CFM\u003c\/strong\u003e, well suited to a small room, and \u003cstrong\u003eSleep\u003c\/strong\u003e mode gradually adjusts the setpoint overnight.\u003c\/p\u003e\u003ch3\u003eMaking the most of this size\u003c\/h3\u003e\u003cp\u003eThe 6,000 BTU model is intended for enclosed rooms with their own heating and cooling needs: an attic bedroom that overheats in summer, an office where computers generate heat, or a guest room kept at a lower temperature. In these rooms, the heat pump provides cooling and much of the heating, delivering nearly 2.5 times the heat of a baseboard heater for the same amount of electricity at -8 °C. The \u003cstrong\u003eFollow Me\u003c\/strong\u003e function measures the temperature at the remote control, right where you are, while the \u003cstrong\u003eGentle\u003c\/strong\u003e function redirects the airflow when it becomes uncomfortable.\u003c\/p\u003e\u003cp\u003eIf you want certified heating down to -30 °C in a small room, the Sirius Heat 6,000 BTU using R-454B is another option. We compare the two during the assessment.\u003c\/p\u003e\u003ch3\u003eLogisVert and this size\u003c\/h3\u003e\u003cp\u003eThis system has \u003cstrong\u003eENERGY STAR ID 2410691\u003c\/strong\u003e, but it does not appear on Hydro-Québec’s current LogisVert list: the rebate shown in the product sheet is therefore $0. If financial assistance is important to you, the 12,000 BTU Standard model using R-410A appears on the list with a $1,200 rebate. We always verify the current list as of the planned installation date.\u003c\/p\u003e\u003ch2\u003eInstallation details that matter in a small room\u003c\/h2\u003e\u003cp\u003eA small room offers few wall-placement options and little room for error. Here is what we plan.\u003c\/p\u003e\u003ch3\u003eIndoor unit placement\u003c\/h3\u003e\u003cp\u003eThe wall-mounted unit measures \u003cstrong\u003e28.70 x 7.87 x 11.50 inches\u003c\/strong\u003e and weighs 17.6 pounds. We position it so the airflow sweeps across the room without blowing directly onto the bed or workstation. The vertical louver oscillates automatically, while the lateral direction is adjusted manually using the adjustment rod. Adequate ceiling clearance is required for air intake, and the condensate drainage slope is planned from the outset.\u003c\/p\u003e\u003ch3\u003eOutdoor unit\u003c\/h3\u003e\u003cp\u003eThe condenser measures \u003cstrong\u003e30.12 x 11.93 x 21.85 inches\u003c\/strong\u003e, weighs 63.7 pounds, and produces \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e. It includes a \u003cstrong\u003ebase pan heater\u003c\/strong\u003e and an anti-corrosion coating. We install it on a wall bracket anchored to the structure or on a ground stand, above the snow line. DuraStar recommends leaving it powered continuously whenever the outdoor temperature is 0 °C or below.\u003c\/p\u003e\u003ch3\u003eRefrigerant lines\u003c\/h3\u003e\u003cp\u003eThe lines are \u003cstrong\u003e1\/4 and 3\/8 inch\u003c\/strong\u003e, pre-charged for 25 feet, with a maximum length of \u003cstrong\u003e82 feet\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong\u003e33 feet\u003c\/strong\u003e. Beyond the pre-charge length, we add 0.16 ounces of refrigerant per foot. Our installations are fully exposed, with no need to open interior walls, and a finished line cover can be added to protect the lines.\u003c\/p\u003e\u003ch3\u003eElectrical\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e208-230 V\u003c\/strong\u003e power supply, \u003cstrong\u003e13 A MCA\u003c\/strong\u003e, and a \u003cstrong\u003e15 A circuit breaker\u003c\/strong\u003e on a dedicated circuit. This modest requirement integrates easily with most residential panels.\u003c\/p\u003e\u003ch3\u003eUnit functions\u003c\/h3\u003e\u003cp\u003eIn addition to Follow Me, Sleep, and Gentle, the remote control offers \u003cstrong\u003eECO\/GEAR\u003c\/strong\u003e to reduce cooling power consumption, \u003cstrong\u003eTurbo\u003c\/strong\u003e, \u003cstrong\u003eSilence\u003c\/strong\u003e, the \u003cstrong\u003eClean\u003c\/strong\u003e function, a timer, and freeze protection that maintains the room at 8 °C. An alert code appears in the event of a refrigerant leak. Wi-Fi is not built in; DuraStar states that its indoor units are compatible with the DR24VINT2 24 V interface, which allows connection to a third-party Wi-Fi thermostat.\u003c\/p\u003e\u003ch3\u003eR-410A refrigerant\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eR-410A\u003c\/strong\u003e is a non-flammable refrigerant that has been used for many years. According to ENERGY STAR, its global warming potential is 2,088, compared with 470 for R-454B, which the industry is moving toward.\u003c\/p\u003e\u003ch3\u003eWhat is normal\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhite vapour from the condenser during \u003cstrong\u003edefrosting\u003c\/strong\u003e, lasting five to ten minutes.\u003c\/li\u003e\n\u003cli\u003eA three-minute delay before restarting.\u003c\/li\u003e\n\u003cli\u003eA rush of air when the louver returns to position, a slight hissing sound, and plastic creaking.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWater leaking indoors, a persistent error code, or a tripped circuit breaker requires shutting off the unit and arranging a service visit.\u003c\/p\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eClean the \u003cstrong\u003eindoor filters\u003c\/strong\u003e every two weeks, keep the condenser clear of snow, and schedule annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e for the coils, drain, and electrical connections.\u003c\/p\u003e\u003ch3\u003eAirGreen, the right size for every room\u003c\/h3\u003e\u003cp\u003eAirGreen, a family-owned company in \u003cstrong\u003eMontreal\u003c\/strong\u003e, has been installing wall-mounted heat pumps in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e for more than fifteen years. Holding RBQ licences in ventilation, refrigeration, and electrical work, we provide a written quote after a free assessment, with no pressure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the DURASTAR Standard Wall-Mounted Heat Pump | 6,000 BTU - R410A: we will confirm the right size for your room and the best location for each unit.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Durastar","offers":[{"title":"Default Title","offer_id":56308981629220,"sku":"DRA1U09S1B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_DURASTAR_STANDARD_6000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_3cf3a19e-df2b-4aff-866b-ca7a82ca7521.png?v=1789646608","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-durastar-standard-6000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}