{"product_id":"thermopompe-murale-durastar-standard-9000-btu-r410a","title":"DURASTAR Standard Wall-Mounted Heat Pump | 9000 BTU - R410A","description":"\u003ch2\u003eA COP of 2.70 at -8 °C: the efficient 9,000 BTU unit for a bedroom or office\u003c\/h2\u003e\u003cp\u003eThe coefficient of performance, or COP, indicates how many units of heat a heat pump produces for each unit of electricity consumed. An electric baseboard heater has a COP of 1. The \u003cstrong\u003eDURASTAR Standard Wall-Mounted Heat Pump | 9,000 BTU - R410A\u003c\/strong\u003e has a \u003cstrong\u003ecertified COP of 2.70 at -8 °C\u003c\/strong\u003e and \u003cstrong\u003e2.24 at -15 °C\u003c\/strong\u003e. For an electrically heated bedroom or office, this translates into a direct reduction in your bill during the months when heating costs the most.\u003c\/p\u003e\u003cp\u003eIts certified ratings are \u003cstrong\u003e24.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e14.7 EER2\u003c\/strong\u003e, and \u003cstrong\u003e11.6 HSPF2\u003c\/strong\u003e. The system is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e and operates in heating mode down to \u003cstrong\u003e-25 °C\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eCertificate values\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCooling: \u003cstrong\u003e9,000 BTU\/h\u003c\/strong\u003e, range of 2,501 to 11,979 BTU\/h\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e8 °C\u003c\/strong\u003e: 10,000 BTU\/h, range of 3,404 to 13,071 BTU\/h, COP of 3.66\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e8,100 BTU\/h\u003c\/strong\u003e nominal capacity, up to 9,543 BTU\/h maximum capacity, \u003cstrong\u003eCOP of 2.70\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: \u003cstrong\u003e7,500 BTU\/h\u003c\/strong\u003e with a \u003cstrong\u003eCOP of 2.24\u003c\/strong\u003e, and up to 8,564 BTU\/h maximum capacity\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese values come from certificate \u003cstrong\u003eAHRI 207787130\u003c\/strong\u003e, published by NEEP. The certified data stops at -15 °C; the DuraStar manual indicates an operating limit of -25 °C in heating mode for Standard models.\u003c\/p\u003e\u003ch3\u003eStandard or Sirius Heat in 9,000 BTU with R-410A\u003c\/h3\u003e\u003cp\u003eThe 9,000 BTU Sirius Heat with R-410A focuses on reserve capacity in extreme cold: 11,000 BTU\/h at -15 °C and heating down to -30 °C, with a cooling rating of 26.4 SEER2. The Standard model presented here takes a different approach. Its capacity at -15 °C is more modest, but each BTU is produced using less electricity, thanks to a COP of 2.24 compared with 1.85. In a well-insulated room with only one exterior wall, the Standard covers most of the needs and leaves the baseboard heaters to operate mainly during extreme cold.\u003c\/p\u003e\u003ch3\u003eModulation that goes lower in cooling mode\u003c\/h3\u003e\u003cp\u003eAmong the 9,000 BTU DuraStar wall-mounted heat pumps in 208-230 V that we offer, this one has the lowest certified cooling range, down to \u003cstrong\u003e2,501 BTU\/h\u003c\/strong\u003e. During mild, humid evenings, the unit can therefore continue running at a very low output instead of stopping and restarting. The air is dehumidified more effectively, the temperature remains stable, and noise is reduced. \u003cstrong\u003eSleep\u003c\/strong\u003e mode adjusts the setpoint overnight, and the \u003cstrong\u003eECO\/GEAR\u003c\/strong\u003e function reduces cooling energy consumption.\u003c\/p\u003e\u003ch3\u003eLogisVert and this size\u003c\/h3\u003e\u003cp\u003eThis system has \u003cstrong\u003eENERGY STAR ID 2410734\u003c\/strong\u003e, but it does not appear on Hydro-Québec's current LogisVert list. The technical sheet therefore indicates a $0 rebate. If financial assistance is an important consideration, the 12,000 BTU Standard with R-410A appears on the list with a $1,200 rebate. We check the current list as of your scheduled installation date.\u003c\/p\u003e\u003ch2\u003eInstallation, maintenance, and everyday operation of a 9,000 BTU R-410A unit\u003c\/h2\u003e\u003cp\u003eA unit of this size installs quickly, but the same quality standards apply as with a larger model.\u003c\/p\u003e\u003ch3\u003eThe indoor unit\u003c\/h3\u003e\u003cp\u003eThe wall-mounted unit measures \u003cstrong\u003e31.57 x 7.87 x 11.61 inches\u003c\/strong\u003e and weighs 19.0 pounds. With this system, its sound level ranges from \u003cstrong\u003e24 to 40 dB(A)\u003c\/strong\u003e, and its fan offers three settings of \u003cstrong\u003e153, 194, and 291 CFM\u003c\/strong\u003e. We position it so that the airflow covers the room without blowing directly toward the bed or workstation. The vertical louver oscillates automatically; the horizontal direction is adjusted manually using the adjustment rod. The remote also offers \u003cstrong\u003eFollow Me\u003c\/strong\u003e, \u003cstrong\u003eTurbo\u003c\/strong\u003e, \u003cstrong\u003eSilence\u003c\/strong\u003e, \u003cstrong\u003eGentle\u003c\/strong\u003e, the \u003cstrong\u003eClean\u003c\/strong\u003e function, a timer, and freeze protection that maintains the room at 8 °C. An alert code appears in the event of a refrigerant leak. Wi-Fi is not built in; DuraStar indicates that its indoor units are compatible with the DR24VINT2 24 V interface, which accepts a third-party Wi-Fi thermostat.\u003c\/p\u003e\u003ch3\u003eThe outdoor unit\u003c\/h3\u003e\u003cp\u003eThe condenser measures \u003cstrong\u003e30.12 x 11.93 x 21.85 inches\u003c\/strong\u003e, weighs 63.7 pounds, and produces \u003cstrong\u003e53 dB(A)\u003c\/strong\u003e. It is equipped with a \u003cstrong\u003ebase pan heater\u003c\/strong\u003e and an anticorrosion coating. Its compact size suits a balcony, a wall bracket anchored to the structure, or a ground stand, always above the snow line. DuraStar recommends leaving it powered continuously at 0 °C and below.\u003c\/p\u003e\u003ch3\u003eThe refrigerant lines\u003c\/h3\u003e\u003cp\u003eThe lines are \u003cstrong\u003e1\/4 and 3\/8 inch\u003c\/strong\u003e, precharged for 25 feet, with a maximum length of \u003cstrong\u003e82 feet\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong\u003e33 feet\u003c\/strong\u003e. Beyond the precharged length, 0.16 ounces of refrigerant is added per foot. When existing lines of these diameters are in good condition, their cleaning and testing are included. Our installations are fully exposed, with no opening in the interior wall.\u003c\/p\u003e\u003ch3\u003eElectrical requirements\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e208-230 V\u003c\/strong\u003e power supply, \u003cstrong\u003e13 A MCA\u003c\/strong\u003e, and a \u003cstrong\u003e15 A circuit breaker\u003c\/strong\u003e on a dedicated circuit, a modest requirement for most panels in \u003cstrong\u003eMontréal\u003c\/strong\u003e and the suburbs.\u003c\/p\u003e\u003ch3\u003eR-410A refrigerant\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eR-410A\u003c\/strong\u003e is a non-flammable refrigerant that has been proven over many years. According to ENERGY STAR, its global warming potential is 2,088, compared with 470 for R-454B, which is found in newer generations of equipment. We present both options in our quotes.\u003c\/p\u003e\u003ch3\u003eWhat is normal\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhite vapor from the condenser during \u003cstrong\u003edefrosting\u003c\/strong\u003e, which can last five to ten minutes, along with a pause in indoor heating.\u003c\/li\u003e\n\u003cli\u003eA three-minute delay before the compressor restarts.\u003c\/li\u003e\n\u003cli\u003eHeating shutting off below -25 °C, in accordance with the manufacturer's limit.\u003c\/li\u003e\n\u003cli\u003eA slight hissing sound and plastic cracking noises as temperatures change.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWater leaking indoors, a persistent error code, or a tripped circuit breaker warrants a call to our \u003ca href=\"\/en\/pages\/service-de-reparation-thermopompe-murale-grand-montreal\"\u003erepair service\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eMaintenance\u003c\/h3\u003e\u003cp\u003eClean the \u003cstrong\u003eindoor filters\u003c\/strong\u003e every two weeks, as recommended by DuraStar. Keep the condenser clear of snow and leaves, and schedule annual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e for the coils, drain, and electrical connections.\u003c\/p\u003e\u003ch3\u003eAirGreen, your local HVAC team\u003c\/h3\u003e\u003cp\u003eA family-owned \u003cstrong\u003eMontréal\u003c\/strong\u003e company, AirGreen has been installing wall-mounted heat pumps for more than fifteen years in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. We hold RBQ licences in ventilation, refrigeration, and electrical work, along with \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance. The in-home assessment is free, and your quote is provided in writing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSchedule your free estimate for the DURASTAR Standard Wall-Mounted Heat Pump | 9,000 BTU - R410A: we compare the Standard and Sirius Heat models and recommend the most economical option for your room.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Durastar","offers":[{"title":"Default Title","offer_id":56308981694756,"sku":"DRA1U09S1B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_DURASTAR_STANDARD_9000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_9d02e8f0-afd2-4c87-a5af-e627ad51c91f.png?v=1789646647","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-durastar-standard-9000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}