{"product_id":"thermopompe-murale-kinghome-airy-r32-24000-btu","title":"KINGHOME Airy R32 Wall-Mounted Heat Pump | 24000 BTU","description":"\u003ch2 data-section-id=\"gztouj\" data-start=\"69\" data-end=\"146\"\u003eA 24,000 BTU Wall-Mounted Heat Pump Designed for Large Quebec Spaces\u003c\/h2\u003e\n\u003cp data-start=\"148\" data-end=\"812\"\u003eThe \u003cstrong data-start=\"151\" data-end=\"203\"\u003eKINGHOME Airy R32 Wall-Mounted Heat Pump | 24000 BTU\u003c\/strong\u003e is aimed at homeowners looking for a \u003cstrong data-start=\"262\" data-end=\"295\"\u003eheating and air conditioning\u003c\/strong\u003e solution capable of covering a generous space without multiplying devices. With its rated capacity of \u003cstrong data-start=\"394\" data-end=\"408\"\u003e24,000 BTU\u003c\/strong\u003e, its heating operation down to \u003cstrong data-start=\"450\" data-end=\"460\"\u003e-30 °C\u003c\/strong\u003e, its \u003cstrong data-start=\"482\" data-end=\"490\"\u003eR-32\u003c\/strong\u003e refrigerant gas, its \u003cstrong data-start=\"496\" data-end=\"511\"\u003eincluded WiFi\u003c\/strong\u003e, and its eligibility for the \u003cstrong data-start=\"538\" data-end=\"585\"\u003e$2,760 LogisVert provincial subsidy\u003c\/strong\u003e, this model positions itself as a serious option for homes, spacious condos, plexes, light commercial premises, and open-concept spaces in \u003cstrong data-start=\"732\" data-end=\"744\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"746\" data-end=\"755\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"757\" data-end=\"770\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"779\" data-end=\"792\"\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"799\" data-end=\"811\"\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"814\" data-end=\"1507\"\u003eAt AirGreen, we analyze this type of appliance with a very practical perspective: the technical data sheet is important, but the true value of a \u003cstrong data-start=\"955\" data-end=\"977\"\u003ewall-mounted heat pump\u003c\/strong\u003e is mainly measured once installed in a real building, with its constraints of walls, clearances, electricity, piping, insulation, solar orientation, and usage habits. A 24,000 BTU unit can offer excellent comfort, but it must be chosen and installed precisely to avoid classic mistakes: poor wall placement, refrigerant line too long or poorly protected, misdirected condensate, insufficient outdoor clearance in winter, or undersized electrical circuit.\u003c\/p\u003e\n\u003cp data-start=\"1509\" data-end=\"2114\"\u003eThe KINGHOME Airy R32 24,000 BTU uses models \u003cstrong data-start=\"1561\" data-end=\"1577\"\u003eKW24XQ29S1DI\u003c\/strong\u003e for the indoor unit and \u003cstrong data-start=\"1605\" data-end=\"1621\"\u003eKW24XQ29S1DO\u003c\/strong\u003e for the outdoor unit. According to the manufacturer's technical data sheet, this heat pump is \u003cstrong data-start=\"1718\" data-end=\"1733\"\u003eENERGY STAR\u003c\/strong\u003e certified and \u003cstrong data-start=\"1737\" data-end=\"1765\"\u003eCold Climate ENERGY STAR\u003c\/strong\u003e, with \u003cstrong data-start=\"1774\" data-end=\"1792\"\u003eAHRI 217903553\u003c\/strong\u003e and \u003cstrong data-start=\"1810\" data-end=\"1833\"\u003eENERGY STAR ID 4514301\u003c\/strong\u003e. The documentation also indicates a \u003cstrong data-start=\"1873\" data-end=\"1888\"\u003eSEER2 of 27\u003c\/strong\u003e, an \u003cstrong data-start=\"1893\" data-end=\"1908\"\u003eHSPF2 of 10\u003c\/strong\u003e, an \u003cstrong data-start=\"1913\" data-end=\"1931\"\u003eEER of 4.1 W\/W\u003c\/strong\u003e, and a \u003cstrong data-start=\"1938\" data-end=\"1956\"\u003eCOP of 3.9 W\/W\u003c\/strong\u003e, data particularly relevant for comparing its actual performance in seasonal air conditioning and heating.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1dwvsq2\" data-start=\"2116\" data-end=\"2170\"\u003eA 24,000 BTU capacity adapted to high needs\u003c\/h3\u003e\n\u003cp data-start=\"2172\" data-end=\"2941\"\u003eA \u003cstrong data-start=\"2176\" data-end=\"2209\"\u003e24,000 BTU wall-mounted heat pump\u003c\/strong\u003e is not a random choice. It is generally recommended for larger areas, open-plan spaces, certain ground floors, small businesses, offices, dwellings with high ceilings, or spaces where the thermal load is higher. In several AirGreen installations in \u003cstrong data-start=\"2547\" data-end=\"2559\"\u003eMontreal\u003c\/strong\u003e and \u003cstrong data-start=\"2566\" data-end=\"2580\"\u003eMontérégie\u003c\/strong\u003e, we often see clients who hesitate between an 18,000 BTU model and a 24,000 BTU one. The decision is never limited to surface area: insulation, sun exposure, number of windows, type of glazing, ceiling height, air circulation between rooms, and expected heating performance must be taken into account.\u003c\/p\u003e\n\u003cp data-start=\"2943\" data-end=\"3584\"\u003eIn an open-concept bungalow on the \u003cstrong data-start=\"2981\" data-end=\"2993\"\u003eSouth Shore\u003c\/strong\u003e, for example, a client wanted to primarily heat their living room, dining room, and part of the kitchen with a single wall-mounted unit. The challenge was not just power, but air distribution. A poorly placed 24,000 BTU unit would have blown directly into a restricted area, creating a drafty sensation without adequately reaching adjacent zones. By positioning the indoor unit on a longer wall, with sufficient clearance and well-thought-out louver orientation, we were able to improve overall comfort without overloading a single area.\u003c\/p\u003e\n\u003cp data-start=\"3586\" data-end=\"3959\"\u003eThe KINGHOME Airy R32 offers \u003cstrong data-start=\"3616\" data-end=\"3676\"\u003eautomatic control of vertical and horizontal louvers\u003c\/strong\u003e, which helps to better distribute air in larger rooms. This detail becomes important in open spaces, as good airflow orientation can reduce temperature differences between the center of the room, areas near windows, and adjacent corridors.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11bsnsz\" data-start=\"3961\" data-end=\"4022\"\u003eHeating down to -30 °C: an essential criterion in Quebec\u003c\/h3\u003e\n\u003cp data-start=\"4024\" data-end=\"4454\"\u003eThe heating capacity down to \u003cstrong data-start=\"4057\" data-end=\"4067\"\u003e-30 °C\u003c\/strong\u003e is a major argument for Quebec homeowners. In \u003cstrong data-start=\"4127\" data-end=\"4139\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"4141\" data-end=\"4150\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"4152\" data-end=\"4165\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"4174\" data-end=\"4187\"\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"4194\" data-end=\"4206\"\u003eSouth Shore\u003c\/strong\u003e, periods of intense cold are not theoretical. A heat pump that performs well at low temperatures can reduce the use of electric baseboards, improve winter comfort, and contribute to more balanced energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"4456\" data-end=\"4954\"\u003eThe technical data sheet indicates a heating capacity of \u003cstrong data-start=\"4512\" data-end=\"4534\"\u003e24,000 BTU at 47 °F\u003c\/strong\u003e, \u003cstrong data-start=\"4539\" data-end=\"4571\"\u003e23,000 BTU at 17 °F (-8.3 °C)\u003c\/strong\u003e, and \u003cstrong data-start=\"4578\" data-end=\"4608\"\u003e24,000 BTU at 5 °F (-15 °C)\u003c\/strong\u003e, which provides an interesting overview of its performance in cold conditions. For a homeowner, these figures are more useful when interpreted in the context of the building. A well-insulated home with an open area can benefit more from this capacity than a highly compartmentalized dwelling where air circulation is difficult.\u003c\/p\u003e\n\u003cp data-start=\"4956\" data-end=\"5389\"\u003eDuring our estimation visits, we pay particular attention to usage scenarios. Some clients want a heat pump as the primary heat source for a large area; others primarily want an effective supplement that reduces the use of existing electric heating. This nuance influences the unit's positioning, the choice of capacity, and recommendations for use during extreme cold.\u003c\/p\u003e\n\u003ch3 data-section-id=\"cf9v4q\" data-start=\"5391\" data-end=\"5459\"\u003eR-32: a more modern refrigerant for a modern HVAC solution\u003c\/h3\u003e\n\u003cp data-start=\"5461\" data-end=\"5849\"\u003eThe \u003cstrong data-start=\"5480\" data-end=\"5488\"\u003eR-32\u003c\/strong\u003e refrigerant gas is increasingly present in recent wall-mounted systems. For homeowners comparing several models of \u003cstrong data-start=\"5609\" data-end=\"5633\"\u003ewall-mounted heat pumps\u003c\/strong\u003e, this detail is worth considering. R-32 is used in many recent devices due to its thermodynamic properties and its positioning in the evolution of residential HVAC equipment.\u003c\/p\u003e\n\u003cp data-start=\"5851\" data-end=\"6628\"\u003eFor AirGreen, the issue is not limited to the type of refrigerant. An R-32 installation must be carried out rigorously: clean connections, proper vacuum, pressure testing, connection verification, adherence to pipe lengths, and mechanical protection of lines. The KINGHOME Airy 24,000 BTU uses \u003cstrong data-start=\"6195\" data-end=\"6227\"\u003e1\/4 inch piping for the liquid line\u003c\/strong\u003e and \u003cstrong data-start=\"6234\" data-end=\"6262\"\u003e5\/8 inch for the gas line\u003c\/strong\u003e, with a maximum refrigerant line length of \u003cstrong data-start=\"6316\" data-end=\"6329\"\u003e131 feet\u003c\/strong\u003e and a maximum height difference of \u003cstrong data-start=\"6371\" data-end=\"6383\"\u003e82 feet\u003c\/strong\u003e according to technical documentation. This data is important when the outdoor unit needs to be placed far from the indoor unit, for example in certain plexes in \u003cstrong data-start=\"6552\" data-end=\"6564\"\u003eMontreal\u003c\/strong\u003e or in commercial installations with access constraints.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t0azzw\" data-start=\"6630\" data-end=\"6702\"\u003eOutdoor Installation: Clearance, Snow, and Defrost Drainage\u003c\/h3\u003e\n\u003cp data-start=\"6704\" data-end=\"7177\"\u003eOne of the most important points for a wall-mounted heat pump in Quebec is the installation of the outdoor unit. The technical data sheet specifies that the unit must be placed a minimum of \u003cstrong data-start=\"6890\" data-end=\"6926\"\u003e18 inches above surfaces\u003c\/strong\u003e to allow for snow clearance and drainage during defrost cycles. This detail is essential. A unit placed too low can become partially blocked by snow, ice, or defrost water that refreezes around the base.\u003c\/p\u003e\n\u003cp data-start=\"7179\" data-end=\"7679\"\u003eAt AirGreen, we often recommend installation on a wall bracket or a raised ground support depending on the building's configuration. In certain alleys in \u003cstrong data-start=\"7348\" data-end=\"7360\"\u003eMontreal\u003c\/strong\u003e, outdoor space is limited, and it is necessary to reconcile performance, safety, aesthetics, service access, and local regulations. On the \u003cstrong data-start=\"7498\" data-end=\"7511\"\u003eNorth Shore\u003c\/strong\u003e or the \u003cstrong data-start=\"7518\" data-end=\"7530\"\u003eSouth Shore\u003c\/strong\u003e, properties sometimes offer more flexibility, but wind, snow accumulation, and terrain slope must still be analyzed.\u003c\/p\u003e\n\u003cp data-start=\"7681\" data-end=\"8223\"\u003eA common mistake is to place the compressor in too confined a corner, near a fence, balcony, or retaining wall. Even if the location seems discreet, poor clearance can hinder air exchange and complicate maintenance. The KINGHOME Airy 24,000 BTU requires serious planning, especially since its outdoor unit measures approximately \u003cstrong data-start=\"8054\" data-end=\"8078\"\u003e39 3\/8 inches wide\u003c\/strong\u003e, \u003cstrong data-start=\"8080\" data-end=\"8109\"\u003e16 13\/16 inches deep\u003c\/strong\u003e, and \u003cstrong data-start=\"8113\" data-end=\"8137\"\u003e29 3\/8 inches high\u003c\/strong\u003e. These dimensions must be validated before installation to avoid surprises.\u003c\/p\u003e\n\u003ch3 data-section-id=\"oor6uq\" data-start=\"8225\" data-end=\"8292\"\u003eIndoor unit: sound comfort, airflow, and WiFi control\u003c\/h3\u003e\n\u003cp data-start=\"8294\" data-end=\"8654\"\u003eThe indoor unit of the KINGHOME Airy 24,000 BTU measures approximately \u003cstrong data-start=\"8359\" data-end=\"8382\"\u003e43.70 inches wide\u003c\/strong\u003e, \u003cstrong data-start=\"8384\" data-end=\"8410\"\u003e10.13 inches deep\u003c\/strong\u003e, and \u003cstrong data-start=\"8414\" data-end=\"8437\"\u003e13.66 inches high\u003c\/strong\u003e. This format is consistent with a high-capacity wall-mounted heat pump. It must be installed on a wall capable of supporting the unit, with the necessary clearances for air intake and diffusion.\u003c\/p\u003e\n\u003cp data-start=\"8656\" data-end=\"9081\"\u003eThe indoor sound level varies depending on the fan speed. The documentation indicates \u003cstrong data-start=\"8757\" data-end=\"8769\"\u003e36 dB(A)\u003c\/strong\u003e in Sleep mode and up to \u003cstrong data-start=\"8795\" data-end=\"8807\"\u003e53 dB(A)\u003c\/strong\u003e in Turbo mode, with airflow rates reaching \u003cstrong data-start=\"8863\" data-end=\"8874\"\u003e765 CFM\u003c\/strong\u003e. This range is normal for a 24,000 BTU unit: at low speed, operation remains quieter; at high speed, the unit prioritizes rapid air distribution in a large space.\u003c\/p\u003e\n\u003cp data-start=\"9083\" data-end=\"9515\"\u003eThe \u003cstrong data-start=\"9086\" data-end=\"9101\"\u003eincluded WiFi\u003c\/strong\u003e facilitates daily use. Customers particularly appreciate this feature in chalets, rental units, offices, or homes where they want to preheat or cool the space before arrival. The infrared remote control is included, and the sheet also mentions several wall controller options, which can be useful in certain commercial or multi-unit environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t9escj\" data-start=\"9517\" data-end=\"9577\"\u003eElectricity: a 220 V appliance that needs proper planning\u003c\/h3\u003e\n\u003cp data-start=\"9579\" data-end=\"9987\"\u003eThe KINGHOME Airy R32 24,000 BTU operates on \u003cstrong data-start=\"9625\" data-end=\"9656\"\u003e208-230 V \/ 60 Hz \/ 1 phase\u003c\/strong\u003e. The technical data sheet indicates an \u003cstrong data-start=\"9689\" data-end=\"9704\"\u003eMCA of 25 A\u003c\/strong\u003e and an \u003cstrong data-start=\"9712\" data-end=\"9727\"\u003eMOP of 30 A\u003c\/strong\u003e, with recommended power wiring in \u003cstrong data-start=\"9774\" data-end=\"9786\"\u003e10\/3 AWG\u003c\/strong\u003e and interconnection cable in \u003cstrong data-start=\"9819\" data-end=\"9831\"\u003e14\/4 AWG\u003c\/strong\u003e. This point must be verified before installation, especially in older homes, condos, or plexes where the electrical panel is already heavily loaded.\u003c\/p\u003e\n\u003cp data-start=\"9989\" data-end=\"10544\"\u003eA client in \u003cstrong data-start=\"10002\" data-end=\"10015\"\u003eLongueuil\u003c\/strong\u003e recently asked us for a 24,000 BTU solution to replace an old wall-mounted air conditioner. The first thought would have been to assume that existing electricity could be reused. After verification, the circuit was not suitable for the new capacity. This step prevented a problematic installation and allowed for proper coordination of electrical work before commissioning. This is exactly the type of detail that distinguishes a simple appliance installation from a true professional \u003cstrong data-start=\"10506\" data-end=\"10527\"\u003eHVAC installation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"di614j\" data-start=\"10546\" data-end=\"10604\"\u003eLogisVert Subsidy: A Significant Financial Advantage\u003c\/h3\u003e\n\u003cp data-start=\"10606\" data-end=\"11170\"\u003eThe product page indicates a \u003cstrong data-start=\"10634\" data-end=\"10681\"\u003eLogisVert provincial subsidy of $2,760\u003c\/strong\u003e, updated on \u003cstrong data-start=\"10698\" data-end=\"10718\"\u003eNovember 26, 2025\u003c\/strong\u003e. For an appliance of this capacity, this aid can have a major impact on the net cost of the project. Homeowners shopping for a \u003cstrong data-start=\"10859\" data-end=\"10892\"\u003ewall-mounted heat pump in Montreal\u003c\/strong\u003e, \u003cstrong data-start=\"10896\" data-end=\"10905\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"10909\" data-end=\"10922\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"10931\" data-end=\"10944\"\u003eNorth Shore\u003c\/strong\u003e, or the \u003cstrong data-start=\"10951\" data-end=\"10963\"\u003eSouth Shore\u003c\/strong\u003e often compare installed prices, but it is always necessary to look at the total after subsidy, the quality of the installation, the warranty, the availability of after-sales service, and the conformity of the model.\u003c\/p\u003e\n\u003cp data-start=\"11172\" data-end=\"11551\"\u003eAt AirGreen, we help clients understand the information needed for their subsidy application: paid invoice, model installed, proof of eligibility, AHRI number, and technical data. A cheaper quote can become less attractive if the model is not eligible, if the installation is incomplete, or if after-sales support is absent.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fdg8gg\" data-start=\"11553\" data-end=\"11590\"\u003eWarranty and Peace of Mind\u003c\/h3\u003e\n\u003cp data-start=\"11592\" data-end=\"12187\"\u003eThe warranty displayed on the product page is \u003cstrong data-start=\"11640\" data-end=\"11669\"\u003e12 years on the compressor\u003c\/strong\u003e, \u003cstrong data-start=\"11671\" data-end=\"11696\"\u003e12 years on parts\u003c\/strong\u003e, and \u003cstrong data-start=\"11700\" data-end=\"11739\"\u003e0 years by default on labor\u003c\/strong\u003e, with the possibility of extended warranty. The manufacturer's data sheet also mentions a standard warranty of \u003cstrong data-start=\"11853\" data-end=\"11884\"\u003e7 years parts and compressor\u003c\/strong\u003e, which can be extended to \u003cstrong data-start=\"11908\" data-end=\"11940\"\u003e12 years parts and compressor\u003c\/strong\u003e when registration and applicable conditions are met. This nuance is important, as warranties often depend on product registration, compliance with manufacturer conditions, and the quality of the installation.\u003c\/p\u003e\n\u003cp data-start=\"12189\" data-end=\"12522\"\u003eAirGreen offers extended labor warranty options for clients who desire more comprehensive protection. In residential and multi-unit projects, this peace of mind can be greatly appreciated, especially when an appliance is used as a significant heating source during winter.\u003c\/p\u003e\n\u003ch2 data-section-id=\"cpy0jc\" data-start=\"12524\" data-end=\"12603\"\u003eWhy AirGreen Recommends Professional Installation for This Model\u003c\/h2\u003e\n\u003cp data-start=\"12605\" data-end=\"12871\"\u003eThe KINGHOME Airy R32 24,000 BTU is an interesting device, but its performance directly depends on the quality of its installation. A \u003cstrong data-start=\"12742\" data-end=\"12764\"\u003ewall-mounted heat pump\u003c\/strong\u003e of this power must be treated as a complete HVAC system, and not just a simple wall unit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ux9b61\" data-start=\"12873\" data-end=\"12929\"\u003eMistakes to avoid with a 24,000 BTU heat pump\u003c\/h3\u003e\n\u003cp data-start=\"12931\" data-end=\"13016\"\u003eThe most common mistakes we observe in the field are as follows:\u003c\/p\u003e\n\u003cul data-start=\"13018\" data-end=\"13561\"\u003e\n\u003cli data-section-id=\"1038wyb\" data-start=\"13018\" data-end=\"13131\"\u003eChoosing too high a capacity for a closed room, which can negatively impact comfort and dehumidification.\u003c\/li\u003e\n\u003cli data-section-id=\"1qiw99t\" data-start=\"13132\" data-end=\"13219\"\u003eInstalling the indoor unit too close to the ceiling, a side wall, or an obstruction.\u003c\/li\u003e\n\u003cli data-section-id=\"60eysv\" data-start=\"13220\" data-end=\"13304\"\u003ePlacing the outdoor unit too low, without considering snow and defrosting.\u003c\/li\u003e\n\u003cli data-section-id=\"xu3y4u\" data-start=\"13305\" data-end=\"13363\"\u003eNeglecting the slope and evacuation of the condensate drain.\u003c\/li\u003e\n\u003cli data-section-id=\"zqiycu\" data-start=\"13364\" data-end=\"13428\"\u003eReusing old piping without adequate verification.\u003c\/li\u003e\n\u003cli data-section-id=\"m5233t\" data-start=\"13429\" data-end=\"13488\"\u003eUnderestimating the electrical needs of a 220 V appliance.\u003c\/li\u003e\n\u003cli data-section-id=\"13sbznf\" data-start=\"13489\" data-end=\"13561\"\u003eForgetting future access for HVAC maintenance and after-sales service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"13563\" data-end=\"13767\"\u003eThese details are not secondary. They influence the compressor's durability, noise level, energy efficiency, heating stability in winter, and daily customer satisfaction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hnq48p\" data-start=\"13769\" data-end=\"13816\"\u003eOur field installation method\u003c\/h3\u003e\u003cp data-start=\"13818\" data-end=\"14352\"\u003eDuring an AirGreen installation, we validate the indoor location, outdoor location, line length, duct protection, power supply, drainage, and service access. We carry out the necessary technical steps, including refrigerant connection, vacuum pulling, compliance testing, and commissioning. We also explain to the client how to use the main modes, how to adjust the vents, how to clean the filters, and when to schedule \u003cstrong data-start=\"14333\" data-end=\"14351\"\u003eHVAC maintenance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"14354\" data-end=\"14912\"\u003eIn a home in \u003cstrong data-start=\"14373\" data-end=\"14382\"\u003eLaval\u003c\/strong\u003e, for example, a recent installation of a comparable capacity unit reminded us of the importance of exterior finishing. The client wanted an efficient solution but refused to let the ducts detract from the facade's appearance. We adapted the routing, neatly protected the lines, and positioned the outdoor unit in an accessible location without compromising aesthetics. This type of work requires more thought than a standard installation, but it makes a big difference to final satisfaction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1k53153\" data-start=\"14914\" data-end=\"14986\"\u003eFor what types of projects is this model particularly relevant\u003c\/h3\u003e\n\u003cp data-start=\"14988\" data-end=\"15085\"\u003eThe \u003cstrong data-start=\"14991\" data-end=\"15043\"\u003eKINGHOME Airy R32 Wall-Mounted Heat Pump | 24000 BTU\u003c\/strong\u003e can be an excellent candidate for:\u003c\/p\u003e\n\u003cul data-start=\"15087\" data-end=\"15544\"\u003e\n\u003cli data-section-id=\"47k2q\" data-start=\"15087\" data-end=\"15123\"\u003ean open-plan ground floor;\u003c\/li\u003e\n\u003cli data-section-id=\"xtarg2\" data-start=\"15124\" data-end=\"15186\"\u003ea large living room with connecting kitchen and dining room;\u003c\/li\u003e\n\u003cli data-section-id=\"1bniuf4\" data-start=\"15187\" data-end=\"15236\"\u003ea spacious condo with good air circulation;\u003c\/li\u003e\n\u003cli data-section-id=\"1lussxu\" data-start=\"15237\" data-end=\"15275\"\u003ean office or light commercial space;\u003c\/li\u003e\n\u003cli data-section-id=\"2zvhet\" data-start=\"15276\" data-end=\"15347\"\u003ea dwelling where one wishes to reduce electric heating use;\u003c\/li\u003e\n\u003cli data-section-id=\"6km6ng\" data-start=\"15348\" data-end=\"15471\"\u003ea property on the \u003cstrong data-start=\"15371\" data-end=\"15383\"\u003eSouth Shore\u003c\/strong\u003e or \u003cstrong data-start=\"15390\" data-end=\"15403\"\u003eNorth Shore\u003c\/strong\u003e where the outdoor unit can be installed with good clearances;\u003c\/li\u003e\n\u003cli data-section-id=\"54wg92\" data-start=\"15472\" data-end=\"15544\"\u003ecertain plexes in \u003cstrong data-start=\"15490\" data-end=\"15502\"\u003eMontreal\u003c\/strong\u003e or \u003cstrong data-start=\"15506\" data-end=\"15519\"\u003eLongueuil\u003c\/strong\u003e, depending on the configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"15546\" data-end=\"15757\"\u003eHowever, the best choice remains the one that matches the actual building. Before recommending this model, AirGreen evaluates the thermal load, location, electrical constraints, and client expectations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xfq6ej\" data-start=\"15759\" data-end=\"15826\"\u003eA complete solution for comfort, performance, and support\u003c\/h3\u003e\n\u003cp data-start=\"15828\" data-end=\"16249\"\u003eThe KINGHOME Airy R32 24,000 BTU combines several sought-after features: \u003cstrong data-start=\"15899\" data-end=\"15927\"\u003eheating down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"15929\" data-end=\"15943\"\u003e24,000 BTU\u003c\/strong\u003e, \u003cstrong data-start=\"15945\" data-end=\"15953\"\u003eR-32\u003c\/strong\u003e, \u003cstrong data-start=\"15955\" data-end=\"15970\"\u003eWiFi included\u003c\/strong\u003e, \u003cstrong data-start=\"15986\" data-end=\"16014\"\u003eENERGY STAR Cold Climate\u003c\/strong\u003e certification, attractive subsidies, and a solid warranty when conditions are met. For homeowners who want a serious \u003cstrong data-start=\"16159\" data-end=\"16189\"\u003eheating and air conditioning\u003c\/strong\u003e solution in Greater Montreal, it clearly deserves analysis.\u003c\/p\u003e\n\u003cp data-start=\"16251\" data-end=\"16826\"\u003eAt AirGreen, we don't just sell equipment. We help our customers choose the right capacity, understand subsidies, avoid installation errors, and achieve a clean, durable result adapted to the Quebec climate. For a quote, technical validation, or personalized recommendation, contact AirGreen today. Our team serves \u003cstrong data-start=\"16645\" data-end=\"16657\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"16659\" data-end=\"16668\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"16670\" data-end=\"16683\"\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong data-start=\"16688\" data-end=\"16701\"\u003eNorth Shore\u003c\/strong\u003e, the \u003cstrong data-start=\"16706\" data-end=\"16718\"\u003eSouth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"16725\" data-end=\"16739\"\u003eMontérégie\u003c\/strong\u003e with professional, transparent, and building-adapted HVAC solutions.\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":53811227328804,"sku":"KW24XQ29S1DO","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOMEairyR32THERMOPOMPEMURALE_c534de6f-ff6b-4743-aa5e-512adad2218c.png?v=1780497411","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-kinghome-airy-r32-24000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}