{"product_id":"thermopompe-murale-kinghome-airy-r32-9000-btu","title":"KINGHOME Airy R32 Wall-Mounted Heat Pump | 9000 BTU","description":"\u003ch2 data-section-id=\"13xooi5\" data-start=\"68\" data-end=\"153\"\u003eA compact, quiet wall-mounted heat pump adapted to Quebec's real winters\u003c\/h2\u003e\n\u003cp data-start=\"155\" data-end=\"661\"\u003eThe \u003cstrong data-start=\"158\" data-end=\"209\"\u003eKINGHOME Airy R32 | 9000 BTU wall-mounted heat pump\u003c\/strong\u003e is for homeowners who want to efficiently heat and cool a targeted room without installing an oversized system. In a condo in \u003cstrong data-start=\"361\" data-end=\"373\"\u003eMontreal\u003c\/strong\u003e, a private office in \u003cstrong data-start=\"393\" data-end=\"402\"\u003eLaval\u003c\/strong\u003e, a master bedroom in \u003cstrong data-start=\"429\" data-end=\"442\"\u003eLongueuil\u003c\/strong\u003e, a residential extension on the \u003cstrong data-start=\"478\" data-end=\"491\"\u003eNorth Shore\u003c\/strong\u003e, or a small commercial space on the \u003cstrong data-start=\"529\" data-end=\"541\"\u003eSouth Shore\u003c\/strong\u003e, a 9,000 BTU wall-mounted unit can offer an excellent balance of comfort, precision, and energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"663\" data-end=\"1192\"\u003eAt AirGreen, we often see the same scenario: a client wants to improve the comfort of a specific room but hesitates between a 9,000, 12,000, or 18,000 BTU heat pump. The natural reflex is sometimes to choose larger, when the right solution depends on the area, insulation, sun orientation, ceiling height, number of windows, room usage, and building configuration. This is precisely where a well-evaluated \u003cstrong data-start=\"1132\" data-end=\"1153\"\u003eHVAC installation\u003c\/strong\u003e makes all the difference.\u003c\/p\u003e\n\u003cp data-start=\"1194\" data-end=\"1671\"\u003eThe 9,000 BTU KINGHOME Airy R32 is particularly interesting because it combines a nominal cooling capacity of \u003cstrong data-start=\"1328\" data-end=\"1341\"\u003e9,100 BTU\u003c\/strong\u003e, a nominal heating capacity of \u003cstrong data-start=\"1381\" data-end=\"1395\"\u003e10,600 BTU\u003c\/strong\u003e, heating performance down to \u003cstrong data-start=\"1434\" data-end=\"1444\"\u003e-30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1465\" data-end=\"1473\"\u003eR-32\u003c\/strong\u003e refrigerant gas, \u003cstrong data-start=\"1478\" data-end=\"1493\"\u003eWiFi included\u003c\/strong\u003e, \u003cstrong data-start=\"1513\" data-end=\"1528\"\u003eENERGY STAR\u003c\/strong\u003e certification, and \u003cstrong data-start=\"1550\" data-end=\"1578\"\u003eCold Climate ENERGY STAR\u003c\/strong\u003e certification according to the manufacturer's technical data sheet.\u003c\/p\u003e\n\u003cp data-start=\"1673\" data-end=\"1978\"\u003eAt AirGreen, we recommend this type of appliance when the need is specific: a room that gets too hot in summer, an area poorly served by the central system, a rental unit where independent comfort is desired, or a room that remains cold despite the main heating.\u003c\/p\u003e\n\u003ch3 data-section-id=\"668a6y\" data-start=\"1980\" data-end=\"2046\"\u003eWell-Calibrated Power for Small and Medium Areas\u003c\/h3\u003e\n\u003cp data-start=\"2048\" data-end=\"2411\"\u003eA 9,000 BTU capacity is generally suitable for spaces where the priority is comfort stability rather than a massive heat or cooling input. In a well-insulated dwelling, this heat pump can be perfectly adapted for a bedroom, a closed living room, a home office, a compact family room, or a moderately sized living area.\u003c\/p\u003e\n\u003cp data-start=\"2413\" data-end=\"2613\"\u003eOne of the advantages of a correctly sized \u003cstrong data-start=\"2438\" data-end=\"2460\"\u003ewall-mounted heat pump\u003c\/strong\u003e is its ability to operate longer at low speed, with fewer sudden stops and starts. This contributes to:\u003c\/p\u003e\n\u003cul data-start=\"2615\" data-end=\"2874\"\u003e\n\u003cli data-section-id=\"33v22s\" data-start=\"2615\" data-end=\"2648\"\u003ea more consistent temperature;\u003c\/li\u003e\n\u003cli data-section-id=\"17jm6v6\" data-start=\"2649\" data-end=\"2700\"\u003ebetter dehumidification in cooling mode;\u003c\/li\u003e\n\u003cli data-section-id=\"b41myu\" data-start=\"2701\" data-end=\"2733\"\u003ea quieter sound level;\u003c\/li\u003e\n\u003cli data-section-id=\"1vklk1e\" data-start=\"2734\" data-end=\"2769\"\u003ebetter controlled consumption;\u003c\/li\u003e\n\u003cli data-section-id=\"1bsijcg\" data-start=\"2770\" data-end=\"2874\"\u003epotentially improved lifespan when installed according to best practices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2876\" data-end=\"3447\"\u003eIn several projects carried out in \u003cstrong data-start=\"2910\" data-end=\"2922\"\u003eMontreal\u003c\/strong\u003e and \u003cstrong data-start=\"2928\" data-end=\"2941\"\u003eLongueuil\u003c\/strong\u003e, we have installed 9,000 BTU units in master bedrooms located on the second floor. These rooms accumulated a lot of heat in July and August, especially when the windows faced southwest. Clients didn't want to cool the entire house, but simply wanted a comfortable bedroom in the evening. A unit like the KINGHOME Airy R32 responds very well to this type of situation, as it allows targeting the need without unnecessarily complicating the HVAC system.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1fqi5yg\" data-start=\"3449\" data-end=\"3508\"\u003eWinter Performance That Really Matters in Quebec\u003c\/h3\u003e\n\u003cp data-start=\"3510\" data-end=\"3862\"\u003eA wall-mounted heat pump sold in Quebec must be judged on its heating performance, not just its cooling. The KINGHOME Airy R32 is designed to operate in heating down to \u003cstrong data-start=\"3705\" data-end=\"3715\"\u003e-30 °C\u003c\/strong\u003e, which is an important requirement for winters in \u003cstrong data-start=\"3780\" data-end=\"3792\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"3794\" data-end=\"3803\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"3805\" data-end=\"3818\"\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong data-start=\"3826\" data-end=\"3839\"\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"3849\" data-end=\"3861\"\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3864\" data-end=\"4248\"\u003eAccording to the technical data sheet for model KW09XQ29S1DI \/ KW09XQ29S1DO, the heating capacity reaches \u003cstrong data-start=\"3971\" data-end=\"3995\"\u003e12,000 BTU at -8.3 °C\u003c\/strong\u003e and \u003cstrong data-start=\"3999\" data-end=\"4022\"\u003e11,500 BTU at -15 °C\u003c\/strong\u003e. This level of performance allows the appliance to be used as an effective heating source in a well-targeted area, while maintaining an auxiliary system as required by the building.\u003c\/p\u003e\n\u003cp data-start=\"4250\" data-end=\"4583\"\u003eWe always advise clients to look at low-temperature performance rather than limiting themselves to nominal capacity. Two heat pumps with the same advertised power can behave very differently when the outdoor temperature drops below -15 °C. For a Quebec residence, this nuance is essential.\u003c\/p\u003e\n\u003ch3 data-section-id=\"8qtwuj\" data-start=\"4585\" data-end=\"4627\"\u003eR-32 Gas, Efficiency, and Certifications\u003c\/h3\u003e\n\u003cp data-start=\"4629\" data-end=\"5064\"\u003e\u003cstrong data-start=\"4632\" data-end=\"4640\"\u003eR-32\u003c\/strong\u003e is a refrigerant increasingly used in modern wall-mounted heat pumps. It allows manufacturers to design efficient appliances with an approach better suited to new energy efficiency expectations. In the case of the KINGHOME Airy R32, the data sheet indicates a \u003cstrong data-start=\"4939\" data-end=\"4954\"\u003eSEER2 of 30\u003c\/strong\u003e, an \u003cstrong data-start=\"4959\" data-end=\"4976\"\u003eHSPF2 of 11.2\u003c\/strong\u003e, an \u003cstrong data-start=\"4981\" data-end=\"5000\"\u003eEER of 4.92 W\/W\u003c\/strong\u003e, and a \u003cstrong data-start=\"5007\" data-end=\"5025\"\u003eCOP of 4.4 W\/W\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5066\" data-end=\"5408\"\u003eThese data indicate that the unit aims for serious performance in both cooling and seasonal heating. For clients comparing several models, these figures help to better understand the real value of a unit, especially when the goal is to reduce electricity consumption while improving comfort.\u003c\/p\u003e\n\u003cp data-start=\"5410\" data-end=\"5861\"\u003eIt is important to note that the product page currently indicates a \u003cstrong data-start=\"5481\" data-end=\"5524\"\u003eLogisVert Provincial Grant of $0\u003c\/strong\u003e for this model, updated on November 26, 2025. This does not diminish the technical interest of the product, but it must be taken into account when analyzing the budget. At AirGreen, we verify eligible models, available amounts, and applicable programs at the time of quotation to avoid unpleasant surprises.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1jntpzw\" data-start=\"5863\" data-end=\"5921\"\u003eQuiet Operation for Bedrooms and Offices\u003c\/h3\u003e\n\u003cp data-start=\"5923\" data-end=\"6188\"\u003eThe announced indoor sound level varies from \u003cstrong data-start=\"5967\" data-end=\"5984\"\u003e23 to 42 dB(A)\u003c\/strong\u003e depending on the fan speed. The detailed sheet notably indicates \u003cstrong data-start=\"6055\" data-end=\"6067\"\u003e23 dB(A)\u003c\/strong\u003e in Sleep mode, \u003cstrong data-start=\"6083\" data-end=\"6095\"\u003e28 dB(A)\u003c\/strong\u003e at low speed, and up to \u003cstrong data-start=\"6123\" data-end=\"6135\"\u003e42 dB(A)\u003c\/strong\u003e in Turbo mode.\u003c\/p\u003e\n\u003cp data-start=\"6190\" data-end=\"6515\"\u003eFor a client installing a heat pump in a bedroom, office, or reading room, this detail is very important. An appliance may perform well on paper but be unpleasant in daily use if the airflow is poorly directed or if the unit is installed too close to the bed, a workstation, or a relaxation area.\u003c\/p\u003e\n\u003cp data-start=\"6517\" data-end=\"7067\"\u003eDuring an installation in \u003cstrong data-start=\"6543\" data-end=\"6552\"\u003eLaval\u003c\/strong\u003e, we once recommended slightly moving the planned location of the wall unit in a bedroom to prevent air from blowing directly towards the head of the bed. This kind of decision doesn't just change the aesthetics; it improves actual comfort. A good \u003cstrong data-start=\"6827\" data-end=\"6865\"\u003ewall-mounted heat pump installation\u003c\/strong\u003e is not just about attaching the appliance to the wall. It requires consideration of air circulation, clearance distances, drainage, noise, service access, and final appearance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"djievl\" data-start=\"7069\" data-end=\"7120\"\u003eAirflow, Dehumidification, and Summer Comfort\u003c\/h3\u003e\n\u003cp data-start=\"7122\" data-end=\"7392\"\u003eThe KINGHOME Airy R32 offers several ventilation levels. The technical sheet indicates an airflow ranging from \u003cstrong data-start=\"7235\" data-end=\"7260\"\u003e265 CFM in Sleep mode\u003c\/strong\u003e to \u003cstrong data-start=\"7263\" data-end=\"7288\"\u003e506 CFM in Turbo mode\u003c\/strong\u003e, with a dehumidification level of \u003cstrong data-start=\"7329\" data-end=\"7353\"\u003e1.69 pints per hour\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7394\" data-end=\"7914\"\u003eIn the greater \u003cstrong data-start=\"7419\" data-end=\"7431\"\u003eMontreal\u003c\/strong\u003e area, summer humidity plays a major role in feelings of discomfort. A room can feel too hot even when the temperature is not extreme, simply because the humidity is high. A properly sized wall-mounted heat pump helps stabilize the temperature and remove some of this humidity. This is particularly useful in condos, top-floor apartments, south-facing rooms, and spaces where natural ventilation is limited.\u003c\/p\u003e\n\u003ch3 data-section-id=\"93ue1n\" data-start=\"7916\" data-end=\"7991\"\u003eTechnical Installation: Details that Protect Your Investment\u003c\/h3\u003e\n\u003cp data-start=\"7993\" data-end=\"8411\"\u003eThe manufacturer's data sheet specifies \u003cstrong data-start=\"8041\" data-end=\"8073\"\u003e1\/4 inch piping for the liquid line\u003c\/strong\u003e and \u003cstrong data-start=\"8077\" data-end=\"8105\"\u003e1\/2 inch for the gas line\u003c\/strong\u003e, a minimum piping length of \u003cstrong data-start=\"8146\" data-end=\"8155\"\u003e10 ft\u003c\/strong\u003e, a maximum length of \u003cstrong data-start=\"8182\" data-end=\"8192\"\u003e100 ft\u003c\/strong\u003e, as well as a maximum vertical elevation of \u003cstrong data-start=\"8235\" data-end=\"8244\"\u003e60 ft\u003c\/strong\u003e. It also indicates a \u003cstrong data-start=\"8286\" data-end=\"8311\"\u003e208-230V \/ 60Hz \/ 1Ph\u003c\/strong\u003e power supply, an \u003cstrong data-start=\"8316\" data-end=\"8330\"\u003eMCA of 10A\u003c\/strong\u003e, and maximum protection \u003cstrong data-start=\"8358\" data-end=\"8372\"\u003eMOP of 15A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"8413\" data-end=\"8529\"\u003eThese details are essential for a safe installation. Before proposing this model, we always validate:\u003c\/p\u003e\n\u003col data-start=\"8531\" data-end=\"8848\"\u003e\n\u003cli data-section-id=\"1v0qloo\" data-start=\"8531\" data-end=\"8568\"\u003ethe available electrical capacity;\u003c\/li\u003e\n\u003cli data-section-id=\"ozqqf0\" data-start=\"8569\" data-end=\"8623\"\u003ethe possible route for the refrigerant piping;\u003c\/li\u003e\n\u003cli data-section-id=\"38zrn8\" data-start=\"8624\" data-end=\"8666\"\u003ethe location of the condensation drain;\u003c\/li\u003e\n\u003cli data-section-id=\"1gij0rm\" data-start=\"8667\" data-end=\"8705\"\u003emechanical protection of the lines;\u003c\/li\u003e\n\u003cli data-section-id=\"1xs0ufc\" data-start=\"8706\" data-end=\"8768\"\u003ethe distance between the indoor and outdoor unit;\u003c\/li\u003e\n\u003cli data-section-id=\"18owix\" data-start=\"8769\" data-end=\"8808\"\u003eclearance around the compressor;\u003c\/li\u003e\n\u003cli data-section-id=\"q8xiux\" data-start=\"8809\" data-end=\"8848\"\u003eaccess for future HVAC maintenance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"8850\" data-end=\"9315\"\u003eOn the \u003cstrong data-start=\"8857\" data-end=\"8869\"\u003eSouth Shore\u003c\/strong\u003e, we often have projects where the outdoor unit must be placed in a restricted backyard, near a fence, balcony, or passageway. In these cases, clearances become essential. The manufacturer's data sheet indicates that the outdoor unit must be placed at least \u003cstrong data-start=\"9158\" data-end=\"9190\"\u003e18 inches above surfaces\u003c\/strong\u003e to allow for snow clearance and drainage during defrost cycles.\u003c\/p\u003e\n\u003cp data-start=\"9317\" data-end=\"9612\"\u003eThis recommendation is particularly important in Quebec. An outdoor unit installed too low can become partially blocked by snow, ice, or frozen defrost water. This can affect performance, increase defrost cycles, and reduce heating comfort.\u003c\/p\u003e\n\u003ch3 data-section-id=\"144pvgt\" data-start=\"9614\" data-end=\"9649\"\u003eCommon Mistakes to Avoid\u003c\/h3\u003e\n\u003cp data-start=\"9651\" data-end=\"9786\"\u003eWe regularly encounter problematic installations done without complete analysis. The most common errors include:\u003c\/p\u003e\n\u003cul data-start=\"9788\" data-end=\"10247\"\u003e\n\u003cli data-section-id=\"d24m1o\" data-start=\"9788\" data-end=\"9841\"\u003echoosing a unit too powerful for a small room;\u003c\/li\u003e\n\u003cli data-section-id=\"1hlny3e\" data-start=\"9842\" data-end=\"9925\"\u003einstalling the indoor unit too close to the ceiling without respecting clearances;\u003c\/li\u003e\n\u003cli data-section-id=\"1qd3eua\" data-start=\"9926\" data-end=\"9977\"\u003edirecting air directly towards a bed or sofa;\u003c\/li\u003e\n\u003cli data-section-id=\"1u7wl5s\" data-start=\"9978\" data-end=\"10007\"\u003eneglecting the drain slope;\u003c\/li\u003e\n\u003cli data-section-id=\"1i0o7jp\" data-start=\"10008\" data-end=\"10067\"\u003einstalling the compressor too low relative to snow;\u003c\/li\u003e\n\u003cli data-section-id=\"10wn58g\" data-start=\"10068\" data-end=\"10108\"\u003epoorly protecting refrigerant lines;\u003c\/li\u003e\n\u003cli data-section-id=\"1cqdd26\" data-start=\"10109\" data-end=\"10148\"\u003eignoring the quality of the vacuum pull;\u003c\/li\u003e\n\u003cli data-section-id=\"1k99flk\" data-start=\"10149\" data-end=\"10195\"\u003enot checking electrical compatibility;\u003c\/li\u003e\n\u003cli data-section-id=\"f9bwtw\" data-start=\"10196\" data-end=\"10247\"\u003eunderestimating the importance of after-sales service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"10249\" data-end=\"10607\"\u003eAt AirGreen, we place great importance on \u003cstrong data-start=\"10304\" data-end=\"10322\"\u003evacuum pulling\u003c\/strong\u003e, pressure testing, circuit sealing, exterior finishing, and comprehensive functional verification. A high-performance heat pump can lose much of its value if poorly installed. The product matters, but the quality of the installation matters just as much.\u003c\/p\u003e\n\u003ch3 data-section-id=\"fdg8gg\" data-start=\"10609\" data-end=\"10646\"\u003eWarranty and Peace of Mind\u003c\/h3\u003e\n\u003cp data-start=\"10648\" data-end=\"11082\"\u003eThe product page indicates a default warranty of \u003cstrong data-start=\"10688\" data-end=\"10717\"\u003e12 years on the compressor\u003c\/strong\u003e, \u003cstrong data-start=\"10719\" data-end=\"10744\"\u003e12 years on parts\u003c\/strong\u003e, and \u003cstrong data-start=\"10748\" data-end=\"10772\"\u003e0 year on labor\u003c\/strong\u003e, with the possibility of extended warranty. The manufacturer's data sheet also mentions a standard warranty of \u003cstrong data-start=\"10893\" data-end=\"10924\"\u003e7 years on parts and compressor\u003c\/strong\u003e, which can be extended to \u003cstrong data-start=\"10943\" data-end=\"10975\"\u003e12 years on parts and compressor\u003c\/strong\u003e when the unit is registered, according to applicable conditions.\u003c\/p\u003e\n\u003cp data-start=\"11084\" data-end=\"11527\"\u003eAt AirGreen, we clearly explain the difference between the manufacturer's warranty and the labor warranty. This distinction avoids misunderstandings. A customer may have a covered part but still need to budget for diagnostic, travel, or replacement costs if labor is not included. This is why we offer additional warranty options when the customer desires more comprehensive coverage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"186j1xb\" data-start=\"11529\" data-end=\"11582\"\u003eWhy Choose AirGreen for This Installation\u003c\/h3\u003e\n\u003cp data-start=\"11584\" data-end=\"11933\"\u003eAirGreen supports its clients at every step: model selection, technical validation, clear quotation, installation, commissioning, usage advice, and after-sales service. Our approach is designed for the realities of buildings in \u003cstrong data-start=\"11829\" data-end=\"11841\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"11843\" data-end=\"11852\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"11854\" data-end=\"11867\"\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong data-start=\"11875\" data-end=\"11888\"\u003eNorth Shore\u003c\/strong\u003e, the \u003cstrong data-start=\"11896\" data-end=\"11908\"\u003eSouth Shore\u003c\/strong\u003e, and \u003cstrong data-start=\"11918\" data-end=\"11932\"\u003eMontérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11935\" data-end=\"12248\"\u003eWe don't just offer a wall-mounted heat pump. We offer a complete solution adapted to the building. Before starting work, we always send a transparent final offer. The goal is simple: avoid surprises, install cleanly, and deliver a reliable system that the client understands well.\u003c\/p\u003e\n\u003cp data-start=\"12250\" data-end=\"12605\"\u003eOur refrigeration technicians evaluate the details that make a difference: location, drainage, clearances, sound level, electrical supply, line protection, future access for maintenance, and interior and exterior aesthetics. This rigor helps avoid many problems that often appear several months after a rushed installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"sfm9o5\" data-start=\"12607\" data-end=\"12667\"\u003eA precise solution for efficient comfort, without excess\u003c\/h2\u003e\n\u003cp data-start=\"12669\" data-end=\"13096\"\u003eThe \u003cstrong data-start=\"12672\" data-end=\"12723\"\u003eKINGHOME Airy R32 | 9000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is a relevant choice for clients seeking a compact, quiet, efficient unit adapted to Quebec's cold temperatures. Its \u003cstrong data-start=\"12886\" data-end=\"12914\"\u003eCold Climate ENERGY STAR\u003c\/strong\u003e certification, operation down to \u003cstrong data-start=\"12943\" data-end=\"12953\"\u003e-30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"12959\" data-end=\"12974\"\u003eincluded WiFi\u003c\/strong\u003e, \u003cstrong data-start=\"12984\" data-end=\"12992\"\u003eR-32\u003c\/strong\u003e gas, seasonal performance, and wall-mounted format make it a serious option for targeted rooms.\u003c\/p\u003e\n\u003cp data-start=\"13098\" data-end=\"13400\"\u003eHowever, to achieve the best results, one must go beyond the technical data sheet. Proper sizing, quality of installation, unit placement, condensation management, and adherence to clearances are essential. This is precisely what we excel at at AirGreen.\u003c\/p\u003e\u003cp data-start=\"13402\" data-end=\"13762\"\u003eFor a quote, an analysis of your space, or a comparison with other models of wall-mounted heat pumps, contact AirGreen now. We will help you choose a clear, efficient, and suitable HVAC solution for your home or commercial building in \u003cstrong data-start=\"13678\" data-end=\"13690\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"13692\" data-end=\"13701\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"13703\" data-end=\"13716\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"13725\" data-end=\"13738\"\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong data-start=\"13749\" data-end=\"13761\"\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":53811223855396,"sku":"KW09XQ29S1DO","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOMEairyR32THERMOPOMPEMURALE.png?v=1780497435","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-kinghome-airy-r32-9000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}