{"product_id":"thermopompe-murale-kinghome-charmo-r32-9000-btu-115v","title":"KINGHOME Charmo R32 Wall-Mounted Heat Pump | 9000 BTU 115V","description":"\u003ch2 data-section-id=\"1w7ayyk\" data-start=\"75\" data-end=\"162\"\u003eA compact, efficient, wall-mounted heat pump designed for small areas in Quebec\u003c\/h2\u003e\n\u003cp data-start=\"164\" data-end=\"800\"\u003eThe \u003cstrong data-start=\"167\" data-end=\"223\"\u003eKINGHOME Charmo R32 9000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e is for homeowners looking for a precise, quiet, and well-suited \u003cstrong data-start=\"282\" data-end=\"312\"\u003eheating and air conditioning\u003c\/strong\u003e solution for small to medium-sized residential spaces. For a condo, master bedroom, home office, rental unit, home extension, or a room difficult to stabilize with the existing central system, this model offers an interesting combination: \u003cstrong data-start=\"643\" data-end=\"651\"\u003e115V\u003c\/strong\u003e power, \u003cstrong data-start=\"671\" data-end=\"679\"\u003eR-32\u003c\/strong\u003e operation, \u003cstrong data-start=\"703\" data-end=\"732\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e certified performance, heating down to \u003cstrong data-start=\"752\" data-end=\"762\"\u003e-25 °C\u003c\/strong\u003e, included WiFi, and a discreet wall-mounted design.\u003c\/p\u003e\n\u003cp data-start=\"802\" data-end=\"1420\"\u003eAt AirGreen, we often see this type of need during our HVAC installations in \u003cstrong data-start=\"888\" data-end=\"900\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"902\" data-end=\"911\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"913\" data-end=\"926\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"935\" data-end=\"948\"\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"955\" data-end=\"967\"\u003eSouth Shore\u003c\/strong\u003e. The client isn't always looking to air condition an entire house. Sometimes they want to solve a very specific problem: a room that's too hot in the summer, an office space that becomes uncomfortable, a dwelling poorly served by the main heating, or a bedroom located above a garage that quickly loses heat in winter. In these situations, a \u003cstrong data-start=\"1326\" data-end=\"1357\"\u003e9000 BTU wall-mounted heat pump\u003c\/strong\u003e can be much more logical than an oversized appliance.\u003c\/p\u003e\n\u003cp data-start=\"1422\" data-end=\"2100\"\u003eThe KINGHOME Charmo R32 9000 BTU 115V model particularly stands out for its balanced technical profile. Its indoor unit is the \u003cstrong data-start=\"1560\" data-end=\"1575\"\u003eKW09HQ19CAI\u003c\/strong\u003e and its outdoor unit is the \u003cstrong data-start=\"1607\" data-end=\"1622\"\u003eKW09HQ19CAO\u003c\/strong\u003e. According to the manufacturer's technical data, the unit offers a nominal cooling capacity of \u003cstrong data-start=\"1732\" data-end=\"1747\"\u003e9,100 BTU\/h\u003c\/strong\u003e, a nominal heating capacity of \u003cstrong data-start=\"1787\" data-end=\"1803\"\u003e10,000 BTU\/h\u003c\/strong\u003e, an AHRI certification \u003cstrong data-start=\"1828\" data-end=\"1841\"\u003e217903550\u003c\/strong\u003e, an ENERGY STAR certification and a \u003cstrong data-start=\"1895\" data-end=\"1933\"\u003eCold Climate Energy Star Heat Pump\u003c\/strong\u003e rating. The technical document also indicates a \u003cstrong data-start=\"1974\" data=\"1991\"\u003eSEER2 of 20.5\u003c\/strong\u003e, an \u003cstrong data-start=\"1996\" data-end=\"2012\"\u003eHSPF2 of 8.8\u003c\/strong\u003e, an \u003cstrong data-start=\"2017\" data-end=\"2035\"\u003eEER of 3.5 W\/W\u003c\/strong\u003e and a \u003cstrong data-start=\"2042\" data-end=\"2061\"\u003eCOP of 3.65 W\/W\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"vnl86g\" data-start=\"2102\" data-end=\"2156\"\u003eWhy a 9000 BTU model can be the right choice\u003c\/h3\u003e\n\u003cp data-start=\"2158\" data-end=\"2569\"\u003eA common mistake when choosing a \u003cstrong data-start=\"2199\" data-end=\"2221\"\u003ewall-mounted heat pump\u003c\/strong\u003e is to believe that a larger unit will automatically provide better comfort. In reality, a system that is too large for the room risks cycling on and off frequently. The result can be less comfortable: varying temperature, less controlled humidity, premature wear of certain components, and a more noticeable noise level.\u003c\/p\u003e\n\u003cp data-start=\"2571\" data-end=\"2625\"\u003eA \u003cstrong data-start=\"2584\" data-end=\"2596\"\u003e9000 BTU\u003c\/strong\u003e model is often relevant for:\u003c\/p\u003e\n\u003cul data-start=\"2627\" data-end=\"2883\"\u003e\n\u003cli data-section-id=\"1hqoy6n\" data-start=\"2627\" data-end=\"2648\"\u003ea closed bedroom;\u003c\/li\u003e\n\u003cli data-section-id=\"18e43sg\" data-start=\"2649\" data-end=\"2672\"\u003ea home office;\u003c\/li\u003e\n\u003cli data-section-id=\"mf7tgd\" data-start=\"2673\" data-end=\"2690\"\u003ea small condo;\u003c\/li\u003e\n\u003cli data-section-id=\"7mgal1\" data-start=\"2691\" data-end=\"2725\"\u003ea room above a garage;\u003c\/li\u003e\n\u003cli data-section-id=\"vbe6zi\" data-start=\"2726\" data-end=\"2757\"\u003ea bachelor apartment;\u003c\/li\u003e\n\u003cli data-section-id=\"1uzi3fk\" data-start=\"2758\" data-end=\"2787\"\u003ean annex or extension;\u003c\/li\u003e\n\u003cli data-section-id=\"1055y1g\" data-start=\"2788\" data-end=\"2826\"\u003ea small, well-insulated open area;\u003c\/li\u003e\n\u003cli data-section-id=\"wit8bm\" data-start=\"2827\" data-end=\"2883\"\u003ean area complementing an existing central system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2885\" data-end=\"3497\"\u003eIn several projects carried out by AirGreen in Greater Montreal, clients contact us after receiving overly general recommendations. For example, a homeowner in Laval initially wanted to install an 18,000 BTU unit in a closed space of about 350 to 450 sq. ft. After analyzing the insulation, solar orientation, windows, and actual use of the room, a more moderate capacity was much more appropriate. The goal is not to install the largest possible appliance; the goal is to install the right appliance, in the right place, with a clean and durable configuration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11lclnu\" data-start=\"3499\" data-end=\"3545\"\u003eA practical advantage: 115V power supply\u003c\/h3\u003e\n\u003cp data-start=\"3547\" data-end=\"3951\"\u003eThe \u003cstrong data-start=\"3550\" data-end=\"3587\"\u003eKINGHOME Charmo R32 9000 BTU 115V\u003c\/strong\u003e can offer a significant advantage in certain buildings, especially when electrical access is limited or when a client wishes to avoid heavier electrical work. Its power supply is \u003cstrong data-start=\"3795\" data-end=\"3812\"\u003e115V\/60Hz\/1Ph\u003c\/strong\u003e, with a minimum circuit ampacity of \u003cstrong data-start=\"3855\" data-end=\"3862\"\u003e19A\u003c\/strong\u003e and a maximum overcurrent protection of \u003cstrong data-start=\"3909\" data-end=\"3916\"\u003e20A\u003c\/strong\u003e, according to technical documentation.\u003c\/p\u003e\n\u003cp data-start=\"3953\" data-end=\"4440\"\u003eThis does not mean that no electrical verification is necessary. At AirGreen, we always validate the condition of the panel, circuit availability, wiring compliance, and building constraints. In some older dwellings in \u003cstrong data-start=\"4210\" data-end=\"4222\"\u003eMontreal\u003c\/strong\u003e, particularly in plexes, converted condos, or buildings where the electrical panel is already overloaded, this step is essential. A reliable HVAC installation always begins even before fixing the unit to the wall.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1krnja1\" data-start=\"4442\" data-end=\"4518\"\u003eHeating down to -25 °C: an important criterion for the Quebec climate\u003c\/h3\u003e\n\u003cp data-start=\"4520\" data-end=\"4889\"\u003eThe Charmo R32 9000 BTU 115V model is designed to operate in heating mode down to \u003cstrong data-start=\"4603\" data-end=\"4613\"\u003e-25 °C\u003c\/strong\u003e. For a client located in \u003cstrong data-start=\"4638\" data-end=\"4651\"\u003eLongueuil\u003c\/strong\u003e, \u003cstrong data-start=\"4653\" data-end=\"4669\"\u003eBoucherville\u003c\/strong\u003e, \u003cstrong data-start=\"4671\" data-end=\"4685\"\u003eTerrebonne\u003c\/strong\u003e, \u003cstrong data-start=\"4687\" data-end=\"4701\"\u003eBlainville\u003c\/strong\u003e, \u003cstrong data-start=\"4703\" data-end=\"4717\"\u003eRepentigny\u003c\/strong\u003e, \u003cstrong data-start=\"4719\" data-end=\"4734\"\u003eSaint-Bruno\u003c\/strong\u003e, \u003cstrong data-start=\"4736\" data-end=\"4748\"\u003eBrossard\u003c\/strong\u003e, or \u003cstrong data-start=\"4752\" data-end=\"4764\"\u003eMontreal\u003c\/strong\u003e, this data truly matters. The Quebec climate imposes conditions that are not like those of more temperate markets.\u003c\/p\u003e\n\u003cp data-start=\"4891\" data-end=\"5404\"\u003eLow-temperature performance is also more nuanced than the simple mention \"heats down to -25 °C\". According to available information, the unit provides approximately \u003cstrong data-start=\"5060\" data-end=\"5086\"\u003e10,600 BTU\/h at -8.3 °C\u003c\/strong\u003e and \u003cstrong data-start=\"5090\" data-end=\"5114\"\u003e7,600 BTU\/h at -15 °C\u003c\/strong\u003e. These figures help to better understand its behavior in winter. In a well-insulated room, these capacities can be very interesting. In a room with high thermal losses, poor sealing, or large windows exposed to the wind, more caution is needed.\u003c\/p\u003e\n\u003cp data-start=\"5406\" data-end=\"5794\"\u003eThat’s why AirGreen never recommends an appliance based solely on BTU numbers. We look at the room, the building, orientation, insulation, lifestyle habits, and the client’s objective. An office used all day doesn’t have the same needs as a bedroom used only at night. A recent condo doesn’t have the same thermal losses as a century-old triplex.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19rikpg\" data-start=\"5796\" data-end=\"5882\"\u003eR-32: a modern refrigerant better suited for new generations of appliances\u003c\/h3\u003e\n\u003cp data-start=\"5884\" data-end=\"6248\"\u003eThis heat pump uses \u003cstrong data-start=\"5913\" data-end=\"5925\"\u003eR-32 gas\u003c\/strong\u003e, a refrigerant increasingly present in modern \u003cstrong data-start=\"5997\" data-end=\"6027\"\u003eheating and air conditioning\u003c\/strong\u003e units. For clients, the benefit is simple: manufacturers are now developing several new platforms around R-32 to improve the performance, efficiency, and environmental impact of systems.\u003c\/p\u003e\n\u003cp data-start=\"6250\" data-end=\"6781\"\u003eDuring an installation, the choice of refrigerant also influences work practices. Our technicians follow procedures adapted to the type of gas, piping diameter, line length, and system charge. The KINGHOME Charmo R32 model uses \u003cstrong data-start=\"6541\" data-end=\"6573\"\u003e1\/4 inch piping for the liquid line\u003c\/strong\u003e and \u003cstrong data-start=\"6577\" data-end=\"6605\"\u003e3\/8 inch for the gas line\u003c\/strong\u003e, with a recommended minimum length of \u003cstrong data-start=\"6649\" data-end=\"6661\"\u003e10 feet\u003c\/strong\u003e, a maximum length of \u003cstrong data-start=\"6688\" data-end=\"6701\"\u003e100 feet\u003c\/strong\u003e, and a maximum vertical difference of \u003cstrong data-start=\"6742\" data-end=\"6754\"\u003e60 feet\u003c\/strong\u003e, according to the technical sheet.\u003c\/p\u003e\n\u003cp data-start=\"6783\" data-end=\"7213\"\u003eThese details may seem secondary, but they have a direct impact on installation quality. A line that is too short, too long, poorly insulated, poorly protected, or poorly drained can lead to performance, noise, drainage, or reliability issues. At AirGreen, we pay particular attention to vacuum pulling, mechanical protection of lines, condensate drainage, and exterior finishing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yg37k2\" data-start=\"7215\" data-end=\"7281\"\u003eIndoor quietness: a strong point for bedrooms and offices\u003c\/h3\u003e\n\u003cp data-start=\"7283\" data-end=\"7660\"\u003eThe indoor unit of the KINGHOME Charmo 9000 BTU offers a sound level as low as \u003cstrong data-start=\"7370\" data-end=\"7382\"\u003e24 dB(A)\u003c\/strong\u003e in Sleep mode, according to documentation. Levels gradually increase with fan speed: approximately \u003cstrong data-start=\"7498\" data-end=\"7510\"\u003e31 dB(A)\u003c\/strong\u003e at low speed, \u003cstrong data-start=\"7529\" data-end=\"7541\"\u003e34 dB(A)\u003c\/strong\u003e at medium speed, \u003cstrong data-start=\"7562\" data-end=\"7574\"\u003e38 dB(A)\u003c\/strong\u003e at high speed, and \u003cstrong data-start=\"7595\" data-end=\"7607\"\u003e43 dB(A)\u003c\/strong\u003e in Turbo mode.\u003c\/p\u003e\n\u003cp data-start=\"7662\" data-end=\"8167\"\u003eIn a real-world context, this can make a big difference. For a bedroom, office, or a room where one works on the phone, operating noise becomes a comfort criterion as important as temperature. We have previously replaced older units in condos in \u003cstrong data-start=\"7960\" data-end=\"7972\"\u003eMontreal\u003c\/strong\u003e simply because the client could no longer tolerate the noise of the indoor unit at night. A recent, well-sized, and well-installed unit can transform the daily experience.\u003c\/p\u003e\n\u003cp data-start=\"8169\" data-end=\"8447\"\u003eAirflow also varies according to modes, ranging from approximately \u003cstrong data-start=\"8230\" data-end=\"8241\"\u003e159 CFM\u003c\/strong\u003e in Sleep mode to \u003cstrong data-start=\"8258\" data-end=\"8269\"\u003e353 CFM\u003c\/strong\u003e in Turbo mode. This allows choosing between very discreet operation and faster air circulation when the room needs to be cooled or heated more quickly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1uo0m6r\" data-start=\"8449\" data-end=\"8506\"\u003eWiFi included, I-Feel function, and automatic cleaning\u003c\/h3\u003e\n\u003cp data-start=\"8508\" data-end=\"8807\"\u003eIncluded WiFi has become an important criterion for many clients. It allows controlling the \u003cstrong data-start=\"8607\" data-end=\"8629\"\u003ewall-mounted heat pump\u003c\/strong\u003e remotely, adjusting the temperature before arriving home, reducing consumption when the room is not in use, and better managing comfort according to schedules.\u003c\/p\u003e\n\u003cp data-start=\"8809\" data-end=\"8875\"\u003eThe technical sheet also mentions several integrated functions:\u003c\/p\u003e\n\u003cul data-start=\"8877\" data-end=\"9015\"\u003e\n\u003cli data-section-id=\"wtgtwl\" data-start=\"8877\" data-end=\"8896\"\u003e\n\u003cstrong data-start=\"8879\" data-end=\"8895\"\u003eWiFi control\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"27r7a5\" data-start=\"8897\" data-end=\"8910\"\u003e\n\u003cstrong data-start=\"8899\" data-end=\"8909\"\u003eI-Feel\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"m6o37u\" data-start=\"8911\" data-end=\"8928\"\u003e\n\u003cstrong data-start=\"8913\" data-end=\"8927\"\u003eSelf clean\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"177tmfr\" data-start=\"8929\" data-end=\"8950\"\u003e\n\u003cstrong data-start=\"8931\" data-end=\"8949\"\u003eForced defrost\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"1lfkgbh\" data-start=\"8951\" data-end=\"8968\"\u003e\n\u003cstrong data-start=\"8953\" data-end=\"8967\"\u003eSoft start\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"11poxr4\" data-start=\"8969\" data-end=\"8995\"\u003e\n\u003cstrong data-start=\"8971\" data-end=\"8994\"\u003eLow voltage startup\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"ekanp\" data-start=\"8996\" data-end=\"9015\"\u003e\n\u003cstrong data-start=\"8998\" data-end=\"9014\"\u003e8 °C heating\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"9017\" data-end=\"9529\"\u003eThe \u003cstrong data-start=\"9029\" data-end=\"9039\"\u003eI-Feel\u003c\/strong\u003e function can be particularly useful, as it allows for a temperature reading closer to the occupied area, depending on the configuration. The \u003cstrong data-start=\"9195\" data-end=\"9203\"\u003e8 °C\u003c\/strong\u003e maintenance mode can also appeal to some clients for rarely used spaces, such as a workshop, a secondary room, or a sporadically used property. It's not a universal solution, but in some scenarios, it can help prevent an excessive temperature drop while limiting consumption.\u003c\/p\u003e\n\u003ch3 data-section-id=\"weo3j\" data-start=\"9531\" data-end=\"9604\"\u003eOutdoor installation: clearances, snow, and defrost drainage\u003c\/h3\u003e\n\u003cp data-start=\"9606\" data-end=\"10073\"\u003eProper outdoor installation is essential for winter performance. The manufacturer's documentation specifies that the outdoor unit must be installed at least \u003cstrong data-start=\"9783\" data-end=\"9819\"\u003e18 inches above surfaces\u003c\/strong\u003e to allow for snow clearance and drainage during defrost cycles. It also indicates minimum clearances around the outdoor unit, notably to ensure adequate airflow.\u003c\/p\u003e\n\u003cp data-start=\"10075\" data-end=\"10579\"\u003eIn the \u003cstrong data-start=\"10093\" data-end=\"10105\"\u003eMontreal\u003c\/strong\u003e area, this point is very important. An outdoor unit installed too low can quickly be affected by snow accumulation, ice, runoff, or freeze-thaw cycles. At AirGreen, we often recommend a wall mount or a ground mount well adapted to the site. The choice depends on several factors: foundation type, terrain slope, access for maintenance, noise transmitted to the structure, wind exposure, aesthetics, and co-ownership constraints.\u003c\/p\u003e\n\u003cp data-start=\"10581\" data-end=\"11101\"\u003eIn a typical project on the \u003cstrong data-start=\"10611\" data-end=\"10623\"\u003eSouth Shore\u003c\/strong\u003e, for example, a client wanted to place the outdoor unit in a narrow corner between a fence and a wall. On paper, the location seemed practical. On site, we found that air would have been poorly evacuated and that snow accumulation would have hindered operation. We moved the unit a few feet, added a more appropriate support, and maintained a clean finish. The client obtained a more reliable installation without compromising the exterior appearance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"w8ynfw\" data-start=\"11103\" data-end=\"11171\"\u003eWhere to install the indoor unit for optimal comfort\u003c\/h3\u003e\n\u003cp data-start=\"11173\" data-end=\"11627\"\u003eThe choice of indoor location is as important as the model selection. For a \u003cstrong data-start=\"11262\" data-end=\"11293\"\u003e9000 BTU wall-mounted heat pump\u003c\/strong\u003e, the goal is to achieve efficient air distribution without creating direct discomfort. A unit placed too close to a bed, workstation, or sofa can blow directly on occupants. Conversely, a unit placed too far from the main area may operate longer without achieving the desired comfort.\u003c\/p\u003e\n\u003cp data-start=\"11629\" data-end=\"11657\"\u003eWe generally evaluate:\u003c\/p\u003e\n\u003col data-start=\"11659\" data-end=\"11968\"\u003e\n\u003cli data-section-id=\"mqayfw\" data-start=\"11659\" data-end=\"11695\"\u003eavailable wall height;\u003c\/li\u003e\n\u003cli data-section-id=\"b1cvgj\" data-start=\"11696\" data-end=\"11733\"\u003eclearances around the unit;\u003c\/li\u003e\n\u003cli data-section-id=\"1tqst15\" data-start=\"11734\" data-end=\"11769\"\u003enatural airflow direction;\u003c\/li\u003e\n\u003cli data-section-id=\"wg8s2i\" data-start=\"11770\" data-end=\"11799\"\u003efurniture placement;\u003c\/li\u003e\n\u003cli data-section-id=\"zyfs7z\" data-start=\"11800\" data-end=\"11839\"\u003edistance to the outdoor unit;\u003c\/li\u003e\n\u003cli data-section-id=\"gs86br\" data-start=\"11840\" data-end=\"11894\"\u003eability to drain condensate properly;\u003c\/li\u003e\n\u003cli data-section-id=\"n9fcb\" data-start=\"11895\" data-end=\"11922\"\u003einterior aesthetics;\u003c\/li\u003e\n\u003cli data-section-id=\"n8c685\" data-start=\"11923\" data-end=\"11968\"\u003erouting of piping and cabling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"11970\" data-end=\"12313\"\u003eThe documentation shows that the indoor unit measures approximately \u003cstrong data-start=\"12032\" data-end=\"12045\"\u003e32 7\/8 inches\u003c\/strong\u003e wide, with minimum clearances to be respected. These details help validate if the chosen wall is truly suitable. In some condos or apartments, a few inches can make all the difference between a clean installation and a forced one.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hzlac9\" data-start=\"12315\" data-end=\"12379\"\u003eWarranty: 12 years parts and compressor after registration\u003c\/h3\u003e\n\u003cp data-start=\"12381\" data-end=\"12755\"\u003eOn the product page, the displayed warranty is \u003cstrong data-start=\"12430\" data-end=\"12452\"\u003e12 years compressor\u003c\/strong\u003e, \u003cstrong data-start=\"12454\" data-end=\"12471\"\u003e12 years parts\u003c\/strong\u003e, and \u003cstrong data-start=\"12475\" data-end=\"12496\"\u003e0 year labor\u003c\/strong\u003e by default, with the possibility of an extended warranty. The technical sheet also specifies a standard warranty of \u003cstrong data-start=\"12612\" data-end=\"12643\"\u003e7 years parts and compressor\u003c\/strong\u003e, which can extend up to \u003cstrong data-start=\"12667\" data-end=\"12699\"\u003e12 years parts and compressor\u003c\/strong\u003e after registration, according to applicable conditions.\u003c\/p\u003e\n\u003cp data-start=\"12757\" data-end=\"13203\"\u003eFor the client, it is important to distinguish between the warranty on parts, the warranty on the compressor, and labor. Many owners think that a manufacturer's warranty automatically covers all costs in the event of a breakdown, but this is not always the case. Parts may be covered, while diagnosis, travel, or labor may depend on the contract, installer, and chosen options.\u003c\/p\u003e\u003cp data-start=\"13205\" data-end=\"13409\"\u003eAirGreen offers additional warranty options according to customer needs. This transparency prevents misunderstandings and allows for the choice of protection tailored to the desired level of peace of mind.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wrbf0f\" data-start=\"13411\" data-end=\"13476\"\u003eLogisVert Subsidy: why the displayed amount is $0\u003c\/h3\u003e\n\u003cp data-start=\"13478\" data-end=\"13848\"\u003eOn this product sheet, the \u003cstrong data-start=\"13506\" data-end=\"13542\"\u003eLogisVert Provincial Subsidy\u003c\/strong\u003e is indicated as \u003cstrong data-start=\"13558\" data-end=\"13565\"\u003e$0\u003c\/strong\u003e, with an update on \u003cstrong data-start=\"13591\" data-end=\"13611\"\u003eNovember 26, 2025\u003c\/strong\u003e. This means that one should not assume a subsidy amount simply because a device is ENERGY STAR or Cold Climate. Programs change, criteria can vary, and eligibility depends on several factors.\u003c\/p\u003e\n\u003cp data-start=\"13850\" data-end=\"14230\"\u003eAt AirGreen, we always recommend verifying the information at the time of quotation. For some customers, the final choice of a \u003cstrong data-start=\"13990\" data-end=\"14012\"\u003ewall-mounted heat pump\u003c\/strong\u003e may be influenced by subsidy eligibility. For others, the main criteria might be 115V power supply, availability, format, ease of installation, or compatibility with the space.\u003c\/p\u003e\n\u003cp data-start=\"14232\" data-end=\"14476\"\u003eIn this specific case, the product remains interesting even without a displayed subsidy, particularly for projects where a compact, quiet, R-32, and 115V compatible device better suits the building than a more expensive or complex solution.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1c1cjx4\" data-start=\"14478\" data-end=\"14550\"\u003eMistakes to avoid before buying a 9000 BTU wall-mounted heat pump\u003c\/h3\u003e\n\u003cp data-start=\"14552\" data-end=\"14667\"\u003eBefore choosing the \u003cstrong data-start=\"14572\" data-end=\"14609\"\u003eKINGHOME Charmo R32 9000 BTU 115V\u003c\/strong\u003e, here are the most common mistakes we encounter:\u003c\/p\u003e\n\u003cul data-start=\"14669\" data-end=\"15173\"\u003e\n\u003cli data-section-id=\"144r7pn\" data-start=\"14669\" data-end=\"14751\"\u003echoosing capacity based solely on area, without considering insulation;\u003c\/li\u003e\n\u003cli data-section-id=\"1avphga\" data-start=\"14752\" data-end=\"14843\"\u003eplacing the indoor unit based solely on aesthetics, without considering air diffusion;\u003c\/li\u003e\n\u003cli data-section-id=\"g5y6wc\" data-start=\"14844\" data-end=\"14897\"\u003eunderestimating the importance of condensate drainage;\u003c\/li\u003e\n\u003cli data-section-id=\"lri0ri\" data-start=\"14898\" data-end=\"14961\"\u003einstalling the outdoor unit too low relative to snow;\u003c\/li\u003e\n\u003cli data-section-id=\"1pg6jqc\" data-start=\"14962\" data-end=\"15004\"\u003eneglecting ventilation clearances;\u003c\/li\u003e\n\u003cli data-section-id=\"14j8125\" data-start=\"15005\" data-end=\"15048\"\u003eforgetting to validate the electrical panel;\u003c\/li\u003e\n\u003cli data-section-id=\"1227pdi\" data-start=\"15049\" data-end=\"15119\"\u003ecomparing only the price without comparing installation quality;\u003c\/li\u003e\n\u003cli data-section-id=\"1168mp9\" data-start=\"15120\" data-end=\"15173\"\u003enot planning for future access for HVAC maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"15175\" data-end=\"15428\"\u003eA durable \u003cstrong data-start=\"15179\" data-end=\"15200\"\u003eHVAC installation\u003c\/strong\u003e relies on several details. A quality appliance can yield poor results if improperly installed. Conversely, a well-chosen and properly installed model can provide excellent comfort for many years.\u003c\/p\u003e\n\u003ch3 data-section-id=\"h5qvqe\" data-start=\"15430\" data-end=\"15508\"\u003eWhy choose AirGreen for the installation of this KINGHOME Charmo R32\u003c\/h3\u003e\n\u003cp data-start=\"15510\" data-end=\"15949\"\u003eAirGreen supports clients at every step: model recommendation, technical validation, clear quotation, careful installation, after-sales service, and maintenance options. We work in a wide variety of contexts: single-family homes, condos, plexes, small businesses, rental properties, and multi-residential buildings in \u003cstrong data-start=\"15850\" data-end=\"15862\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"15864\" data-end=\"15873\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"15875\" data-end=\"15888\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"15897\" data-end=\"15910\"\u003eNorth Shore\u003c\/strong\u003e, the \u003cstrong data-start=\"15915\" data-end=\"15927\"\u003eSouth Shore\u003c\/strong\u003e, and in \u003cstrong data-start=\"15934\" data-end=\"15948\"\u003eMontérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"15951\" data-end=\"16053\"\u003eOur installations are planned with particular attention to the elements that truly matter:\u003c\/p\u003e\n\u003cul data-start=\"16055\" data-end=\"16333\"\u003e\n\u003cli data-section-id=\"123elsn\" data-start=\"16055\" data-end=\"16074\"\u003echoice of the correct BTU;\u003c\/li\u003e\n\u003cli data-section-id=\"1m0gevs\" data-start=\"16075\" data-end=\"16111\"\u003eefficient indoor positioning;\u003c\/li\u003e\n\u003cli data-section-id=\"1uvftjq\" data-start=\"16112\" data-end=\"16159\"\u003eoutdoor support adapted to the Quebec climate;\u003c\/li\u003e\n\u003cli data-section-id=\"elbj3m\" data-start=\"16160\" data-end=\"16198\"\u003ewell-protected refrigerant lines;\u003c\/li\u003e\n\u003cli data-section-id=\"qdjcrt\" data-start=\"16199\" data-end=\"16226\"\u003erigorous vacuum pulling;\u003c\/li\u003e\n\u003cli data-section-id=\"bwj5f2\" data-start=\"16227\" data-end=\"16257\"\u003eclean condensate management;\u003c\/li\u003e\n\u003cli data-section-id=\"mvpcxk\" data-start=\"16258\" data-end=\"16280\"\u003eaesthetic finish;\u003c\/li\u003e\n\u003cli data-section-id=\"13fu7vg\" data-start=\"16281\" data-end=\"16333\"\u003eclear explanation to the client after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"16335\" data-end=\"16673\"\u003eThe \u003cstrong data-start=\"16338\" data-end=\"16394\"\u003eKINGHOME Charmo R32 9000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e can be an excellent choice when a project requires a compact, modern, and efficient solution for a specific area. It is not intended to replace a professional building analysis, but it offers a solid technical basis for many residential projects.\u003c\/p\u003e\n\u003cp data-start=\"16675\" data-end=\"16981\"\u003eFor a precise recommendation, a clear quotation, or a complete installation, contact AirGreen. Our team can help you validate if this model suits your space, compare available options, and plan a clean, reliable \u003cstrong data-start=\"16915\" data-end=\"16936\"\u003eHVAC installation\u003c\/strong\u003e tailored to your property.\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":53811202588964,"sku":"KW09HQ19CAO","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOMECHARMOR32THERMOPOMPEMURALE.png?v=1780497543","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-kinghome-charmo-r32-9000-btu-115v","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}