{"product_id":"thermopompe-murale-kinghome-clivia-r32-12000-btu-115v","title":"KINGHOME Clivia R32 Wall-Mounted Heat Pump | 12000 BTU 115V","description":"\u003ch2 data-section-id=\"19fkwjq\" data-start=\"76\" data-end=\"204\"\u003eA 115V wall-mounted heat pump designed for Quebec homes where simplicity, comfort, and efficiency must go hand in hand\u003c\/h2\u003e\n\u003cp data-start=\"206\" data-end=\"938\"\u003eThe \u003cstrong data-start=\"209\" data-end=\"268\"\u003eKINGHOME Clivia R32 Wall-Mounted Heat Pump | 12000 BTU 115V\u003c\/strong\u003e addresses a very common reality in our residential installations in \u003cstrong data-start=\"345\" data-end=\"357\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"359\" data-end=\"368\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"370\" data-end=\"383\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"392\" data-end=\"405\"\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"412\" data-end=\"424\"\u003eSouth Shore\u003c\/strong\u003e: many homeowners want to improve their comfort without turning their project into a complex construction site. With a \u003cstrong data-start=\"555\" data-end=\"563\"\u003e115V\u003c\/strong\u003e power supply, a capacity of \u003cstrong data-start=\"581\" data-end=\"595\"\u003e12,000 BTU\u003c\/strong\u003e, heating operation down to \u003cstrong data-start=\"636\" data-end=\"646\"\u003e-30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"663\" data-end=\"671\"\u003eR-32\u003c\/strong\u003e refrigerant, \u003cstrong data-start=\"676\" data-end=\"691\"\u003eincluded WiFi\u003c\/strong\u003e, and eligibility for the \u003cstrong data-start=\"718\" data-end=\"764\"\u003e$1200 LogisVert provincial subsidy\u003c\/strong\u003e, this model is positioned as a particularly attractive solution for condos, plexes, small houses, home offices, and well-insulated open-plan spaces.\u003c\/p\u003e\n\u003cp data-start=\"940\" data-end=\"1514\"\u003eAt AirGreen, we evaluate each \u003cstrong data-start=\"976\" data-end=\"997\"\u003eHVAC installation\u003c\/strong\u003e based on three very concrete criteria: the machine's real capacity in the Quebec climate, technical feasibility on site, and the client's daily comfort after installation. The KINGHOME Clivia R32 12,000 BTU 115V is precisely a device that deserves serious analysis, as it combines frequently sought-after practical features: low-temperature operation, \u003cstrong data-start=\"1401\" data-end=\"1430\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e certification, low indoor sound level, compact wall-mounted format, and integrated smart control.\u003c\/p\u003e\n\u003cp data-start=\"1516\" data-end=\"1867\"\u003eAccording to the manufacturer's technical sheet, the indoor model is \u003cstrong data-start=\"1579\" data-end=\"1595\"\u003eKW12XQ25S1AI\u003c\/strong\u003e, the outdoor model \u003cstrong data-start=\"1617\" data-end=\"1633\"\u003eKW12XQ25S1AO\u003c\/strong\u003e, with a nominal cooling and heating capacity of \u003cstrong data-start=\"1700\" data-end=\"1716\"\u003e12,000 BTU\/H\u003c\/strong\u003e, a \u003cstrong data-start=\"1721\" data-end=\"1738\"\u003eSEER2 of 24.5\u003c\/strong\u003e, an \u003cstrong data-start=\"1743\" data-end=\"1759\"\u003eHSPF2 of 9.5\u003c\/strong\u003e, operating on \u003cstrong data-start=\"1782\" data-end=\"1790\"\u003eR-32\u003c\/strong\u003e, and a \u003cstrong data-start=\"1811\" data-end=\"1828\"\u003e115V\/60Hz\/1Ph\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1g31zw9\" data-start=\"1869\" data-end=\"1922\"\u003eA 12,000 BTU unit well-suited for strategic rooms\u003c\/h3\u003e\n\u003cp data-start=\"1924\" data-end=\"2271\"\u003eA \u003cstrong data-start=\"1928\" data-end=\"1961\"\u003e12,000 BTU wall-mounted heat pump\u003c\/strong\u003e should not be chosen simply because the number seems suitable. The right question is always related to the actual space: air volume, solar orientation, insulation, circulation between rooms, ceiling height, presence of large windows, occupant habits, and building configuration.\u003c\/p\u003e\n\u003cp data-start=\"2273\" data-end=\"2357\"\u003eIn several AirGreen projects, a 12,000 BTU unit is particularly relevant for:\u003c\/p\u003e\n\u003cul data-start=\"2359\" data-end=\"2716\"\u003e\n\u003cli data-section-id=\"zvi3m0\" data-start=\"2359\" data-end=\"2391\"\u003ea closed or semi-open living room;\u003c\/li\u003e\n\u003cli data-section-id=\"dd9imm\" data-start=\"2392\" data-end=\"2423\"\u003ea well-insulated condo floor;\u003c\/li\u003e\n\u003cli data-section-id=\"vj9uew\" data-start=\"2424\" data-end=\"2472\"\u003ea master bedroom with high solar gain;\u003c\/li\u003e\n\u003cli data-section-id=\"1a9o4k5\" data-start=\"2473\" data-end=\"2521\"\u003ea home office used all day;\u003c\/li\u003e\n\u003cli data-section-id=\"jtw1ld\" data-start=\"2522\" data-end=\"2593\"\u003ea dwelling in a plex where the electrical panel limits options;\u003c\/li\u003e\n\u003cli data-section-id=\"1sux3fg\" data-start=\"2594\" data-end=\"2675\"\u003ea family room in the basement requiring better humidity control;\u003c\/li\u003e\n\u003cli data-section-id=\"196ar3p\" data-start=\"2676\" data-end=\"2716\"\u003ea moderately sized common area.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2718\" data-end=\"3262\"\u003eIn \u003cstrong data-start=\"2720\" data-end=\"2732\"\u003eMontreal\u003c\/strong\u003e, we often see this type of appliance installed in old plexes where owners want to add comfort without unnecessarily overloading the building. In \u003cstrong data-start=\"2895\" data-end=\"2908\"\u003eLongueuil\u003c\/strong\u003e and on the \u003cstrong data-start=\"2919\" data-end=\"2931\"\u003eSouth Shore\u003c\/strong\u003e, many bungalows or semi-detached houses use a 12,000 BTU wall-mounted unit to stabilize the temperature in the main area. In \u003cstrong data-start=\"3064\" data-end=\"3073\"\u003eLaval\u003c\/strong\u003e and on the \u003cstrong data-start=\"3084\" data-end=\"3097\"\u003eNorth Shore\u003c\/strong\u003e, this model can also be interesting for additions, extensions, or rooms above a garage where the central system does not distribute air uniformly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ysy2d3\" data-start=\"3264\" data-end=\"3328\"\u003eThe true advantage of 115V in a residential installation\u003c\/h3\u003e\n\u003cp data-start=\"3330\" data-end=\"3800\"\u003eThe fact that this \u003cstrong data-start=\"3348\" data-end=\"3379\"\u003eKINGHOME Clivia heat pump\u003c\/strong\u003e operates on \u003cstrong data-start=\"3394\" data-end=\"3402\"\u003e115V\u003c\/strong\u003e is an important element. In certain buildings, especially condos, small plexes, and older homes, the electrical panel or existing configuration can make a 220V installation less straightforward. A 115V unit does not remove the obligation of a compliant electrical installation, but it can facilitate certain scenarios when the project is well-evaluated by a professional.\u003c\/p\u003e\n\u003cp data-start=\"3802\" data-end=\"4239\"\u003eThe technical sheet indicates a \u003cstrong data-start=\"3846\" data-end=\"3863\"\u003e115V\/60Hz\/1Ph\u003c\/strong\u003e power supply, a voltage range of \u003cstrong data-start=\"3889\" data-end=\"3905\"\u003e103 to 127Vac\u003c\/strong\u003e, a minimum circuit ampacity of \u003cstrong data-start=\"3943\" data-end=\"3950\"\u003e19A\u003c\/strong\u003e, and a maximum overcurrent protection of \u003cstrong data-start=\"3997\" data-end=\"4004\"\u003e20A\u003c\/strong\u003e. In practice, this means that this model should never be treated as a simple appliance that can be plugged in anywhere. The installation must comply with the manufacturer's requirements, the Electrical Code, and applicable local regulations.\u003c\/p\u003e\n\u003cp data-start=\"4241\" data-end=\"4281\"\u003eAt AirGreen, we always check:\u003c\/p\u003e\n\u003col data-start=\"4283\" data-end=\"4578\"\u003e\n\u003cli data-section-id=\"cj3vyp\" data-start=\"4283\" data-end=\"4320\"\u003eavailable panel capacity;\u003c\/li\u003e\n\u003cli data-section-id=\"1xn4pnu\" data-start=\"4321\" data-end=\"4345\"\u003ewiring route;\u003c\/li\u003e\n\u003cli data-section-id=\"khr6lo\" data-start=\"4346\" data-end=\"4382\"\u003erequired electrical protection;\u003c\/li\u003e\n\u003cli data-section-id=\"1o19uyf\" data-start=\"4383\" data-end=\"4422\"\u003eoutdoor unit location;\u003c\/li\u003e\n\u003cli data-section-id=\"6litd8\" data-start=\"4423\" data-end=\"4459\"\u003eactual piping length;\u003c\/li\u003e\n\u003cli data-section-id=\"y0h87l\" data-start=\"4460\" data-end=\"4498\"\u003eclearance around the condenser;\u003c\/li\u003e\n\u003cli data-section-id=\"orwb8d\" data-start=\"4499\" data-end=\"4526\"\u003econdensate management;\u003c\/li\u003e\n\u003cli data-section-id=\"1ica8x7\" data-start=\"4527\" data-end=\"4578\"\u003eaesthetic feasibility of line passage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"4580\" data-end=\"4865\"\u003eThis upfront work avoids unpleasant surprises. A successful \u003cstrong data-start=\"4635\" data-end=\"4656\"\u003eHVAC installation\u003c\/strong\u003e is not limited to mounting a wall unit. It requires precise coordination between electricity, refrigeration, drainage, clearances, sealing, and the client's daily experience.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11bsnsz\" data-start=\"4867\" data-end=\"4928\"\u003eHeating down to -30 °C: an essential criterion in Quebec\u003c\/h3\u003e\n\u003cp data-start=\"4930\" data-end=\"5364\"\u003eA heat pump sold in Quebec must be judged in winter, not just in July. The KINGHOME Clivia R32 12,000 BTU 115V is indicated as being capable of heating operation down to \u003cstrong data-start=\"5117\" data-end=\"5127\"\u003e-30 °C\u003c\/strong\u003e. The technical sheet also specifies a heating performance of \u003cstrong data-start=\"5198\" data-end=\"5224\"\u003e10,000 BTU\/H at -8.3 °C\u003c\/strong\u003e and \u003cstrong data-start=\"5228\" data-end=\"5252\"\u003e9,500 BTU\/H at -15 °C\u003c\/strong\u003e, which provides a better understanding of the machine's actual behavior when the outdoor temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"5366\" data-end=\"5761\"\u003eThis data is important, as many clients only compare the nominal capacity of 12,000 BTU. However, a heat pump does not always deliver the same capacity at all temperatures. In winter, the available capacity decreases depending on the technology, compressor, outdoor coil, and defrosting conditions. This is where the analysis of an experienced contractor becomes useful.\u003c\/p\u003e\n\u003cp data-start=\"5763\" data-end=\"6198\"\u003eIn a well-insulated house in \u003cstrong data-start=\"5794\" data-end=\"5803\"\u003eLaval\u003c\/strong\u003e, for example, a 12,000 BTU unit can very well support a specific area for a large part of the winter. In an older apartment in \u003cstrong data-start=\"5955\" data-end=\"5967\"\u003eMontreal\u003c\/strong\u003e with air infiltration and weaker windows, the same appliance may require more frequent supplementary heating. The choice is therefore never made solely from a technical sheet: it must take the building into account.\u003c\/p\u003e\n\u003ch3 data-section-id=\"170gs83\" data-start=\"6200\" data-end=\"6272\"\u003eR-32: a modern refrigerant better suited to new expectations\u003c\/h3\u003e\n\u003cp data-start=\"6274\" data-end=\"6718\"\u003eThe model uses \u003cstrong data-start=\"6311\" data-end=\"6319\"\u003eR-32\u003c\/strong\u003e refrigerant gas, now very present in new generations of \u003cstrong data-start=\"6379\" data-end=\"6403\"\u003ewall-mounted heat pumps\u003c\/strong\u003e. For homeowners, the main interest lies in energy efficiency and evolving industry standards. R-32 generally allows for efficient design with controlled refrigerant charge, while aligning with the current transition towards more responsible HVAC solutions.\u003c\/p\u003e\n\u003cp data-start=\"6720\" data-end=\"7277\"\u003eThe technical sheet indicates a factory charge of \u003cstrong data-start=\"6769\" data-end=\"6778\"\u003e28 oz\u003c\/strong\u003e, a pre-charged length of \u003cstrong data-start=\"6807\" data-end=\"6818\"\u003e24.6 ft\u003c\/strong\u003e, a minimum piping length of \u003cstrong data-start=\"6859\" data-end=\"6868\"\u003e10 ft\u003c\/strong\u003e, a maximum length of \u003cstrong data-start=\"6895\" data-end=\"6905\"\u003e100 ft\u003c\/strong\u003e, and a maximum height difference of \u003cstrong data-start=\"6947\" data-end=\"6956\"\u003e60 ft\u003c\/strong\u003e. These details are very useful in the field. A short installation in a condo in \u003cstrong data-start=\"7044\" data-end=\"7057\"\u003eLongueuil\u003c\/strong\u003e is not planned like an installation in a two-story house in \u003cstrong data-start=\"7131\" data-end=\"7145\"\u003eBlainville\u003c\/strong\u003e or \u003cstrong data-start=\"7149\" data-end=\"7165\"\u003eBoucherville\u003c\/strong\u003e. The line route can influence performance, the required amount of refrigerant, and the final appearance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5p56e5\" data-start=\"7279\" data-end=\"7354\"\u003eA discreet indoor unit, yet efficient in air distribution\u003c\/h3\u003e\n\u003cp data-start=\"7356\" data-end=\"7799\"\u003eThe KINGHOME Clivia indoor unit is compact, with dimensions of approximately \u003cstrong data-start=\"7441\" data-end=\"7467\"\u003e32 61\/64 inches wide\u003c\/strong\u003e, \u003cstrong data-start=\"7469\" data-end=\"7495\"\u003e7 7\/8 inches deep\u003c\/strong\u003e, and \u003cstrong data-start=\"7499\" data-end=\"7525\"\u003e11 17\/32 inches high\u003c\/strong\u003e according to the technical sheet. The indoor sound level varies from \u003cstrong data-start=\"7588\" data-end=\"7600\"\u003e25 dB(A)\u003c\/strong\u003e in Sleep mode to \u003cstrong data-start=\"7617\" data-end=\"7629\"\u003e43 dB(A)\u003c\/strong\u003e in Turbo mode. The airflow reaches up to \u003cstrong data-start=\"7676\" data-end=\"7687\"\u003e400 CFM\u003c\/strong\u003e in Turbo mode, with several intermediate levels allowing adjustment of comfort according to room usage.\u003c\/p\u003e\n\u003cp data-start=\"7801\" data-end=\"8217\"\u003eThis modulation is important. In a bedroom, the client often seeks very discreet operation. In a living room with an open kitchen, the airflow must be sufficient to mix the air without causing discomfort. In a home office, stability becomes a priority: no one wants a unit that blows too hard during a video call or lets the room get too hot in the afternoon.\u003c\/p\u003e\n\u003cp data-start=\"8219\" data-end=\"8290\"\u003eIncluded functions according to the technical sheet include:\u003c\/p\u003e\n\u003cul data-start=\"8292\" data-end=\"8477\"\u003e\n\u003cli data-section-id=\"1fa6xi3\" data-start=\"8292\" data-end=\"8312\"\u003e\n\u003cstrong data-start=\"8294\" data-end=\"8311\"\u003eWiFi control\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"xkisxw\" data-start=\"8313\" data-end=\"8330\"\u003e8 °C heating;\u003c\/li\u003e\n\u003cli data-section-id=\"gl191h\" data-start=\"8331\" data-end=\"8353\"\u003e\n\u003cstrong data-start=\"8342\" data-end=\"8352\"\u003eI-Feel\u003c\/strong\u003e function;\u003c\/li\u003e\n\u003cli data-section-id=\"dkhfxe\" data-start=\"8354\" data-end=\"8370\"\u003eself-cleaning;\u003c\/li\u003e\n\u003cli data-section-id=\"1tumt0m\" data-start=\"8371\" data-end=\"8389\"\u003eforced defrost;\u003c\/li\u003e\n\u003cli data-section-id=\"1m64iwz\" data-start=\"8390\" data-end=\"8413\"\u003esoft start;\u003c\/li\u003e\n\u003cli data-section-id=\"6kby7n\" data-start=\"8414\" data-end=\"8442\"\u003elow voltage start-up;\u003c\/li\u003e\n\u003cli data-section-id=\"eop2z3\" data-start=\"8443\" data-end=\"8477\"\u003einfrared remote control included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"8479\" data-end=\"8821\"\u003eFor many AirGreen clients, \u003cstrong data-start=\"8515\" data-end=\"8530\"\u003eincluded WiFi\u003c\/strong\u003e has become a practical criterion. It allows for adjusting the temperature remotely, preparing comfort before returning home, or better managing a rental property. This can be particularly useful for a condo, an intergenerational dwelling, or a small income property.\u003c\/p\u003e\n\u003ch3 data-section-id=\"weo3j\" data-start=\"8823\" data-end=\"8896\"\u003eOutdoor installation: clearances, snow, and defrost drainage\u003c\/h3\u003e\n\u003cp data-start=\"8898\" data-end=\"9445\"\u003eThe technical page for the outdoor unit specifies a point that we consider essential in Quebec: the unit must be placed at least \u003cstrong data-start=\"9034\" data-end=\"9074\"\u003e18 inches above any surface\u003c\/strong\u003e to allow for snow clearance and defrost water drainage. This recommendation is far from a minor detail. In the \u003cstrong data-start=\"9224\" data-end=\"9236\"\u003eMontreal\u003c\/strong\u003e area, on the \u003cstrong data-start=\"9245\" data-end=\"9258\"\u003eNorth Shore\u003c\/strong\u003e, and in \u003cstrong data-start=\"9265\" data-end=\"9279\"\u003eMontérégie\u003c\/strong\u003e, improper installation height can lead to ice accumulation around the condenser, reduced airflow, and avoidable service calls.\u003c\/p\u003e\n\u003cp data-start=\"9447\" data-end=\"9505\"\u003eAt AirGreen, we pay particular attention to:\u003c\/p\u003e\n\u003cul data-start=\"9507\" data-end=\"9822\"\u003e\n\u003cli data-section-id=\"rg16j1\" data-start=\"9507\" data-end=\"9558\"\u003ethe height of the wall mount or ground stand;\u003c\/li\u003e\n\u003cli data-section-id=\"vwnb7f\" data-start=\"9559\" data-end=\"9609\"\u003ethe blowing direction of the outdoor unit;\u003c\/li\u003e\n\u003cli data-section-id=\"c82qd9\" data-start=\"9610\" data-end=\"9645\"\u003eexposure to prevailing winds;\u003c\/li\u003e\n\u003cli data-section-id=\"1vfeu6u\" data-start=\"9646\" data-end=\"9696\"\u003epossible snow accumulation from the roof;\u003c\/li\u003e\n\u003cli data-section-id=\"mjotw8\" data-start=\"9697\" data-end=\"9733\"\u003eaccess for \u003cstrong data-start=\"9714\" data-end=\"9732\"\u003eHVAC maintenance\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"iilfza\" data-start=\"9734\" data-end=\"9775\"\u003eprotection of refrigerant lines;\u003c\/li\u003e\n\u003cli data-section-id=\"146ahd9\" data-start=\"9776\" data-end=\"9822\"\u003ewinter defrost water drainage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"9824\" data-end=\"10150\"\u003eAn outdoor unit installed too low can work perfectly in September, then become problematic in January. This is a mistake we sometimes see during replacements of installations done too quickly. A low-temperature heat pump needs real clearance to breathe and defrost properly.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12bcagd\" data-start=\"10152\" data-end=\"10237\"\u003eA LogisVert subsidy of $1200 that greatly improves the value for money\u003c\/h3\u003e\n\u003cp data-start=\"10239\" data-end=\"10542\"\u003eThe information displayed on the AirGreen website indicates a \u003cstrong data-start=\"10295\" data-end=\"10341\"\u003eLogisVert provincial subsidy of $1200\u003c\/strong\u003e, updated on \u003cstrong data-start=\"10358\" data-end=\"10378\"\u003eNovember 26, 2025\u003c\/strong\u003e, for this \u003cstrong data-start=\"10391\" data-end=\"10449\"\u003eKINGHOME Clivia R32 12,000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e. For a homeowner, this amount can significantly alter the net cost of the project.\u003c\/p\u003e\n\u003cp data-start=\"10544\" data-end=\"10645\"\u003eHowever, a subsidy should never be the sole selection criterion. One must also consider:\u003c\/p\u003e\n\u003cul data-start=\"10647\" data-end=\"10896\"\u003e\n\u003cli data-section-id=\"13479rw\" data-start=\"10647\" data-end=\"10681\"\u003eactual heating capacity;\u003c\/li\u003e\n\u003cli data-section-id=\"k0f2ta\" data-start=\"10682\" data-end=\"10718\"\u003e\n\u003cstrong data-start=\"10701\" data-end=\"10717\"\u003eENERGY STAR®\u003c\/strong\u003e certification;\u003c\/li\u003e\n\u003cli data-section-id=\"xi886v\" data-start=\"10719\" data-end=\"10755\"\u003ebuilding compatibility;\u003c\/li\u003e\n\u003cli data-section-id=\"wkk8ob\" data-start=\"10756\" data-end=\"10787\"\u003einstallation quality;\u003c\/li\u003e\n\u003cli data-section-id=\"1f11v8d\" data-start=\"10788\" data-end=\"10802\"\u003ewarranty;\u003c\/li\u003e\n\u003cli data-section-id=\"2rkj9a\" data-start=\"10803\" data-end=\"10828\"\u003eafter-sales service;\u003c\/li\u003e\n\u003cli data-section-id=\"fqbvj1\" data-start=\"10829\" data-end=\"10859\"\u003eparts availability;\u003c\/li\u003e\n\u003cli data-section-id=\"tli4ri\" data-start=\"10860\" data-end=\"10896\"\u003eproper electrical configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"10898\" data-end=\"11300\"\u003eThe KINGHOME Clivia offers a coherent package: \u003cstrong data-start=\"10949\" data-end=\"10965\"\u003eENERGY STAR®\u003c\/strong\u003e, \u003cstrong data-start=\"10967\" data-end=\"10983\"\u003eCold Climate\u003c\/strong\u003e, \u003cstrong data-start=\"10985\" data-end=\"11003\"\u003eAHRI 216372815\u003c\/strong\u003e, \u003cstrong data-start=\"11005\" data-end=\"11031\"\u003eENERGY STAR ID 3815295\u003c\/strong\u003e, low-temperature heating, included WiFi, and a registered warranty of \u003cstrong data-start=\"11101\" data-end=\"11133\"\u003e12 years parts and compressor\u003c\/strong\u003e under applicable conditions. The AirGreen site also mentions a \u003cstrong data-start=\"11218\" data-end=\"11233\"\u003e12-12-0 year\u003c\/strong\u003e warranty, with the possibility of additional labor warranty.\u003c\/p\u003e\n\u003ch3 data-section-id=\"jq46s\" data-start=\"11302\" data-end=\"11358\"\u003eWhat we check before recommending this model\u003c\/h3\u003e\n\u003cp data-start=\"11360\" data-end=\"11591\"\u003eBefore recommending a \u003cstrong data-start=\"11385\" data-end=\"11407\"\u003ewall-mounted heat pump\u003c\/strong\u003e like the KINGHOME Clivia, we never limit ourselves to approximate surface area. A technical visit or detailed analysis allows us to validate the actual project conditions.\u003c\/p\u003e\n\u003cp data-start=\"11593\" data-end=\"11619\"\u003eWe notably check:\u003c\/p\u003e\n\u003ch4 data-start=\"11621\" data-end=\"11643\"\u003eThe correct capacity\u003c\/h4\u003e\n\u003cp data-start=\"11645\" data-end=\"11892\"\u003eA 12,000 BTU unit can be excellent in a specific area, but insufficient for an entire very open or poorly insulated house. Conversely, installing too large a unit can lead to short cycles, poor dehumidification, and less stable comfort.\u003c\/p\u003e\n\u003ch4 data-start=\"11894\" data-end=\"11926\"\u003eAvailable interior wall space\u003c\/h4\u003e\u003cp data-start=\"11928\" data-end=\"12112\"\u003eThe indoor unit must be positioned to distribute air correctly. A wall too close to a hallway, beam, or large opening can limit perceived effectiveness.\u003c\/p\u003e\n\u003ch4 data-start=\"12114\" data-end=\"12139\"\u003eThe path of the lines\u003c\/h4\u003e\n\u003cp data-start=\"12141\" data-end=\"12328\"\u003eThe piping for this model is specified as \u003cstrong data-start=\"12184\" data-end=\"12216\"\u003e1\/4 inch for the liquid line\u003c\/strong\u003e and \u003cstrong data-start=\"12220\" data-end=\"12248\"\u003e1\/2 inch for the gas line\u003c\/strong\u003e. The path must be clean, protected, and compatible with permitted lengths.\u003c\/p\u003e\n\u003ch4 data-start=\"12330\" data-end=\"12346\"\u003eDrainage\u003c\/h4\u003e\n\u003cp data-start=\"12348\" data-end=\"12518\"\u003eA poorly planned drain can create water, noise, or maintenance problems. We always favor a natural slope when possible, with a careful finish.\u003c\/p\u003e\n\u003ch4 data-start=\"12520\" data-end=\"12548\"\u003eOutdoor clearance\u003c\/h4\u003e\n\u003cp data-start=\"12550\" data-end=\"12721\"\u003eThe condenser must be accessible, well-ventilated, and protected against accumulation. An aesthetic outdoor installation should never compromise functionality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"p66aaw\" data-start=\"12723\" data-end=\"12794\"\u003eConcrete example: a typical installation in a Montreal plex\u003c\/h3\u003e\n\u003cp data-start=\"12796\" data-end=\"13172\"\u003eIn a plex in eastern \u003cstrong data-start=\"12821\" data-end=\"12833\"\u003eMontreal\u003c\/strong\u003e, a client wanted to air condition and heat primarily a double living room connected to a dining room. The building had limited electrical supply, and the owner wanted to avoid extensive electrical work. After analysis, a \u003cstrong data-start=\"13082\" data-end=\"13120\"\u003e12,000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e was the most logical size for the targeted area.\u003c\/p\u003e\n\u003cp data-start=\"13174\" data-end=\"13611\"\u003eThe main challenge was not capacity, but positioning. The ideal wall for air diffusion was near a thicker masonry section, and the exterior path had to remain discreet to preserve the appearance of the side facade. Our technicians planned a clean exit, a reduced line path, an outdoor support high enough for snow, and a finish with mechanical protection.\u003c\/p\u003e\n\u003cp data-start=\"13613\" data-end=\"13932\"\u003eThe result was simple: better temperature stability, reduced use of electric baseboard heaters in the main area, increased comfort in summer, and a discreet installation. This is exactly the type of project where a machine like the KINGHOME Clivia can offer excellent value when properly chosen.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rbovwy\" data-start=\"13934\" data-end=\"14003\"\u003eCommon mistakes to avoid with a 12,000 BTU wall-mounted heat pump\u003c\/h3\u003e\n\u003cp data-start=\"14005\" data-end=\"14181\"\u003eEven a good appliance can yield poor results if the installation or selection is done incorrectly. The most common mistakes we encounter are:\u003c\/p\u003e\n\u003cul data-start=\"14183\" data-end=\"14710\"\u003e\n\u003cli data-section-id=\"axmtfg\" data-start=\"14183\" data-end=\"14226\"\u003echoosing solely based on the displayed price;\u003c\/li\u003e\n\u003cli data-section-id=\"jev6no\" data-start=\"14227\" data-end=\"14283\"\u003eneglecting heating capacity at low temperatures;\u003c\/li\u003e\n\u003cli data-section-id=\"1t831lc\" data-start=\"14284\" data-end=\"14346\"\u003eplacing the indoor unit in a corner where air circulates poorly;\u003c\/li\u003e\n\u003cli data-section-id=\"15ge1ox\" data-start=\"14347\" data-end=\"14390\"\u003einstalling the condenser too close to the ground;\u003c\/li\u003e\n\u003cli data-section-id=\"36h64m\" data-start=\"14391\" data-end=\"14438\"\u003eforgetting the impact of snow and defrosting;\u003c\/li\u003e\n\u003cli data-section-id=\"1la4vuk\" data-start=\"14439\" data-end=\"14480\"\u003eunderestimating electrical requirements;\u003c\/li\u003e\n\u003cli data-section-id=\"1ke94k1\" data-start=\"14481\" data-end=\"14544\"\u003echoosing a model ineligible for a desired subsidy;\u003c\/li\u003e\n\u003cli data-section-id=\"1rilj18\" data-start=\"14545\" data-end=\"14589\"\u003eignoring the quality of after-sales service;\u003c\/li\u003e\n\u003cli data-section-id=\"1bbfo58\" data-start=\"14590\" data-end=\"14652\"\u003eaccepting an exterior finish without adequate protection;\u003c\/li\u003e\n\u003cli data-section-id=\"1igy4x9\" data-start=\"14653\" data-end=\"14710\"\u003efailing to plan for future access for \u003cstrong data-start=\"14691\" data-end=\"14709\"\u003eHVAC maintenance\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"14712\" data-end=\"14916\"\u003eAt AirGreen, we prefer to explain these details before the sale rather than correcting problems afterward. This approach protects the client and ensures a longer lifespan for the installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"7s9dnx\" data-start=\"14918\" data-end=\"15011\"\u003eWhy choose AirGreen for the installation of your KINGHOME Clivia R32 12,000 BTU 115V\u003c\/h2\u003e\n\u003cp data-start=\"15013\" data-end=\"15398\"\u003eA high-performance \u003cstrong data-start=\"15017\" data-end=\"15039\"\u003ewall-mounted heat pump\u003c\/strong\u003e depends as much on the product as on the contractor who installs it. At AirGreen, we install HVAC systems in a wide variety of contexts: condos in \u003cstrong data-start=\"15206\" data-end=\"15218\"\u003eMontreal\u003c\/strong\u003e, single-family homes in \u003cstrong data-start=\"15244\" data-end=\"15253\"\u003eLaval\u003c\/strong\u003e, plexes in \u003cstrong data-start=\"15262\" data-end=\"15275\"\u003eLongueuil\u003c\/strong\u003e, properties on the \u003cstrong data-start=\"15294\" data-end=\"15307\"\u003eNorth Shore\u003c\/strong\u003e, family residences on the \u003cstrong data-start=\"15338\" data-end=\"15350\"\u003eSouth Shore\u003c\/strong\u003e, and multi-housing buildings in \u003cstrong data-start=\"15383\" data-end=\"15397\"\u003eMontérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"15400\" data-end=\"15813\"\u003eOur advantage is concrete: we know the local constraints. We know that a hundred-year-old brick wall is not treated like modern cladding. We know that the condenser's location can become critical after a single snowstorm. We know that a client wants a clean finish, a quiet unit, stable temperature, and a team capable of responding after installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rw6l62\" data-start=\"15815\" data-end=\"15873\"\u003eA clean, compliant installation designed to last\u003c\/h3\u003e\n\u003cp data-start=\"15875\" data-end=\"16054\"\u003eDuring our installations, we pay particular attention to steps that are not always visible in a final photo but directly influence reliability:\u003c\/p\u003e\n\u003cul data-start=\"16056\" data-end=\"16337\"\u003e\n\u003cli data-section-id=\"19uxql8\" data-start=\"16056\" data-end=\"16081\"\u003ethorough vacuum pull;\u003c\/li\u003e\n\u003cli data-section-id=\"ef98tp\" data-start=\"16082\" data-end=\"16110\"\u003echecking connections;\u003c\/li\u003e\n\u003cli data-section-id=\"1qxbojk\" data-start=\"16111\" data-end=\"16144\"\u003eadequate line protection;\u003c\/li\u003e\n\u003cli data-section-id=\"3dd29g\" data-start=\"16145\" data-end=\"16176\"\u003ecareful condensate management;\u003c\/li\u003e\n\u003cli data-section-id=\"1srdopb\" data-start=\"16177\" data-end=\"16203\"\u003erespect for clearances;\u003c\/li\u003e\n\u003cli data-section-id=\"1vn8wvw\" data-start=\"16204\" data-end=\"16244\"\u003esolid fastening of the indoor unit;\u003c\/li\u003e\n\u003cli data-section-id=\"1prxdxp\" data-start=\"16245\" data-end=\"16280\"\u003eaccessible outdoor location;\u003c\/li\u003e\n\u003cli data-section-id=\"1j8dtls\" data-start=\"16281\" data-end=\"16337\"\u003eclear usage tips after startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"16339\" data-end=\"16513\"\u003eThis rigor makes a difference. A quick installation can work the same day. A well-done installation continues to work well years later.\u003c\/p\u003e\n\u003ch3 data-section-id=\"89o8dv\" data-start=\"16515\" data-end=\"16585\"\u003eA good choice for clients who want an intelligent balance\u003c\/h3\u003e\n\u003cp data-start=\"16587\" data-end=\"16909\"\u003eThe KINGHOME Clivia R32 12,000 BTU 115V is particularly suitable for clients looking for an \u003cstrong data-start=\"16684\" data-end=\"16715\"\u003eefficient wall-mounted heat pump\u003c\/strong\u003e, an appliance compatible with Quebec's climate, a \u003cstrong data-start=\"16783\" data-end=\"16791\"\u003e115V\u003c\/strong\u003e power supply, an attractive \u003cstrong data-start=\"16797\" data-end=\"16821\"\u003eLogisVert subsidy\u003c\/strong\u003e, and a superior level of comfort without unnecessarily complicating the project.\u003c\/p\u003e\n\u003cp data-start=\"16911\" data-end=\"17269\"\u003eThis model is not automatically the best choice for every home. Some properties will need an 18,000 BTU, a multi-zone system, a central system, or another configuration. But when it matches the building, it can offer an excellent balance between net cost, efficiency, comfort, ease of installation, and winter performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"p35gn9\" data-start=\"17271\" data-end=\"17337\"\u003eContact AirGreen for a clear and personalized evaluation\u003c\/h3\u003e\n\u003cp data-start=\"17339\" data-end=\"17763\"\u003eTo find out if the \u003cstrong data-start=\"17357\" data-end=\"17416\"\u003eKINGHOME Clivia R32 Wall-Mounted Heat Pump | 12000 BTU 115V\u003c\/strong\u003e is suitable for your home, condo, plex, or light commercial space, contact AirGreen. We will help you validate the capacity, location, electrical configuration, eligibility for subsidies, and the best installation options for your building in \u003cstrong data-start=\"17683\" data-end=\"17695\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"17697\" data-end=\"17706\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"17708\" data-end=\"17721\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"17730\" data-end=\"17743\"\u003eNorth Shore\u003c\/strong\u003e, or the \u003cstrong data-start=\"17750\" data-end=\"17762\"\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17765\" data-end=\"17898\"\u003eRequest your AirGreen quote today for a professional, clean, and tailored \u003cstrong data-start=\"17825\" data-end=\"17846\"\u003eHVAC installation\u003c\/strong\u003e that fits your reality.\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":53811216974116,"sku":"KW12XQ25SAO","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/KINGHOMECLIVIAR32THERMOPOMPEMURALE_83da3d8d-ba6b-48d8-a9c1-96c83ed4813b.png?v=1780497466","url":"https:\/\/airgreen.ca\/en\/products\/thermopompe-murale-kinghome-clivia-r32-12000-btu-115v","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}